Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Transfusion ; 46(1): 50-4, 2006 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-16398730

RESUMEN

BACKGROUND: Red blood cell (RBC) storage solutions work in a narrow pH range between 7.2 and 6.4. While keeping RBC within that pH range, ATP production can be increased by buffering or dilution. STUDY DESIGN AND METHODS: In the first study, 12 units of packed CP2D RBCs were pooled in groups of four, re-aliquoted, and added to one of four additive solutions (ASs): AS-3, 110 mL; EAS-61, 170 mL; EAS-78, 170 mL; or EAS-81, 110 mL. EAS-78 and -81 contain bicarbonate. Units were sampled approximately weekly for 10 weeks for biochemical measures. In the second study, 12 volunteers donated RBCs for measures of (51)Cr in vivo recovery after 6 or 8 weeks of storage in EAS-81. RESULTS: RBCs stored in the higher-volume or buffered ASs had higher RBC ATP concentrations. The combination had an additive effect. Hemolysis was reduced in dilute ASs and less so with buffering. RBCs stored for 8 weeks (n=6) in EAS-81 exhibited 87+/- 2 percent 24-hour (51)Cr in vivo recovery and 0.4+/- 0.2 percent hemolysis. CONCLUSIONS: It is possible to store RBCs for 8 weeks in buffered conventional volume ASs. Combining buffering and increased AS volume improves stored RBC characteristics further.


Asunto(s)
Conservación de la Sangre , Eritrocitos , Conservación de la Sangre/métodos , Tampones (Química) , Eritrocitos/metabolismo , Hemólisis , Humanos , Concentración de Iones de Hidrógeno
2.
Br J Radiol ; 67(802): 964-8, 1994 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-8000840

RESUMEN

The technetium hexamethylpropyleneamineoxime labelled white cell scan (WCS) is not widely used as a screening test for Crohn's disease primarily because, though sensitive, it is perceived as being insufficiently specific. A series of 42 patients screened for Crohn's disease by this method was analysed retrospectively. The sensitivity was 100% and specificity 91%. This performance was maintained in a subgroup of these patients with very low prevalence of disease. If appropriate criteria for interpretation are used the WCS is a specific as well as a sensitive screening test for Crohn's disease.


Asunto(s)
Enfermedad de Crohn/diagnóstico por imagen , Leucocitos/diagnóstico por imagen , Compuestos de Organotecnecio , Oximas , Adolescente , Adulto , Anciano , Niño , Diagnóstico Diferencial , Reacciones Falso Positivas , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Cintigrafía , Estudios Retrospectivos , Sensibilidad y Especificidad , Exametazima de Tecnecio Tc 99m
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA