1.
Biochem Med (Zagreb) ; 34(2): 020801, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38665868

RESUMEN

Less than 2% of all symptomatic multiple myeloma (MM) has immunoglobulin D (IgD) as monoclonal protein. Biclonal gammopathy is much rarer. At the time of diagnosis, disease is often in advanced stage, including renal failure, anemia, hypercalcemia and lytic bone lesions. Due to the rarity of myeloma itself, but also due to the fact that anti-IgD antisera is not used in routine practice, there are only a few reports of IgD MM described in the literature. This case report describes a patient with IgD lambda MM with anemia and renal failure. Anemia, renal failure, and > 80 percent plasma cells in bone biopsy in our patient with IgD lambda MM meets International Myeloma Working Group criteria for diagnosis of MM. The patient clinical course was similar to other patients with IgD MM. The final result of serum protein immunofixation (s-IFE) showed IgD lambda and free lambda monoclonal bands. To prevent misdiagnosis, it is necessary to use anti-IgD and anti-IgE antisera whenever the serum protein immunofixation with IgA, IgM, IgG, kappa and lambda antiserums shows a kappa or lambda monoclonal band without monoclonal band in heavy chain.


Asunto(s)
Inmunoglobulina D , Cadenas lambda de Inmunoglobulina , Mieloma Múltiple , Humanos , Mieloma Múltiple/complicaciones , Mieloma Múltiple/diagnóstico , Cadenas lambda de Inmunoglobulina/sangre , Inmunoglobulina D/sangre , Masculino , Persona de Mediana Edad
2.
Biochem Med (Zagreb) ; 30(3): 030705, 2020 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-33071556

RESUMEN

INTRODUCTION: The aim of the study was the analytical verification of automated latex-enhanced particle immunoturbidimetric (LPIA) D-Dimer assay INNOVANCE D-dimer on Sysmex CS-5100 and Atellica COAG 360 analysers, and HemosIL D-dimer HS500 on ACL TOP 550, as well as the comparison with the enzyme-linked immunofluorescent assay (ELFA) on the miniVidas analyser. MATERIALS AND METHODS: Verification included assessment of within-run and between-run precision, bias, measurement uncertainty (MU), verification of the cut-off, method comparison between all assessed assays, and the reference commercial ELFA VIDAS D-Dimer Exclusion II. RESULTS: Within-run coefficients of variations (CVs) ranged from 1.6% (Atellica COAG 360) to 7.9% (ACL TOP 550), while between-run CVs ranged from 1.7% (Sysmex CS-5100) to 6.9% (Atellica COAG 360). Spearman's rank correlation coefficients were > 0.99 between LPIAs and ≥ 0.93 when comparing ELFA with LPIA. Passing-Bablok regression analysis yielded constant and proportional difference for comparison of ACL TOP 550 with both Sysmex CS-5100 and Atellica COAG360, and for miniVidas with Atellica COAG360. Small proportional difference was found between miniVidas and both Sysmex CS-5100 and ACL TOP 550. Calculated MUs using D-dimer HS 500 calibrator were 12.6% (Sysmex CS-5100) and 15.6% (Atellica COAG 360), while with INNOVANCE D-dimer calibrator 12.0% (Sysmex CS-5100), 10.0% (Atellica COAG 360) and 28.1% (ACL TOP 550). Excellent agreement of results was obtained, with occasional discrepancies near the cut-off. The cut-off (0.5 mg/L FEU) was confirmed. CONCLUSIONS: The obtained results prove satisfactory analytical performance of LPIAs, their high comparability and almost equal discriminatory characteristics, suggesting them as a valid alternative to ELFA.


Asunto(s)
Productos de Degradación de Fibrina-Fibrinógeno/análisis , Inmunoturbidimetría/métodos , Látex/química , Automatización , Humanos , Juego de Reactivos para Diagnóstico , Tromboembolia Venosa/diagnóstico