Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 111
Filtrar
1.
Diagnostics (Basel) ; 14(10)2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38786276

RESUMEN

Quantitative MRI techniques such as T2 and T1ρ mapping are beneficial in evaluating knee joint pathologies; however, long acquisition times limit their clinical adoption. MIXTURE (Multi-Interleaved X-prepared Turbo Spin-Echo with IntUitive RElaxometry) provides a versatile turbo spin-echo (TSE) platform for simultaneous morphologic and quantitative joint imaging. Two MIXTURE sequences were designed along clinical requirements: "MIX1", combining proton density (PD)-weighted fat-saturated (FS) images and T2 mapping (acquisition time: 4:59 min), and "MIX2", combining T1-weighted images and T1ρ mapping (6:38 min). MIXTURE sequences and their reference 2D and 3D TSE counterparts were acquired from ten human cadaveric knee joints at 3.0 T. Contrast, contrast-to-noise ratios, and coefficients of variation were comparatively evaluated using parametric tests. Clinical radiologists (n = 3) assessed diagnostic quality as a function of sequence and anatomic structure using five-point Likert scales and ordinal regression, with a significance level of α = 0.01. MIX1 and MIX2 had at least equal diagnostic quality compared to reference sequences of the same image weighting. Contrast, contrast-to-noise ratios, and coefficients of variation were largely similar for the PD-weighted FS and T1-weighted images. In clinically feasible scan times, MIXTURE sequences yield morphologic, TSE-based images of diagnostic quality and quantitative parameter maps with additional insights on soft tissue composition and ultrastructure.

2.
Clin Biomech (Bristol, Avon) ; 114: 106239, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38599132

RESUMEN

BACKGROUND: The application of expandable titanium-cages has gained widespread use in vertebral body replacement for indications such as burst fractures, tumors and infectious destruction. However, torque forces necessary for a satisfactory expansion of these implants and for subsidence of them into the adjacent vertebrae are unknown within the osteoporotic spine. METHODS: Six fresh-frozen human, osteoporotic, lumbar spines were dorsally instrumented with titanium implants (L2-L4) and a partial corpectomy of L3 was performed. An expandable titanium-cage was inserted ventrally and expanded by both residents and senior surgeons until fixation was deemed sufficient, based on haptic feedback. Torque forces for expansion were measured in Nm. Expansion was then continued until cage subsidence occurred. Torque forces necessary for subsidence were recorded. Strain of the dorsal rods during expansion was measured with strain gauges. FINDINGS: The mean torque force for fixation of cages was 1.17 Nm (0.9 Nm for residents, 1.4 Nm for senior surgeons, p = .06). The mean torque force for subsidence of cages was 3.1 Nm (p = .005). Mean peak strain of the dorsal rods was 970 µm/m during expansion and 1792 µm/m at subsidence of cages (p = .004). INTERPRETATION: The use of expandable titanium-cages for vertebral body replacement seems to be a primarily safe procedure even within the osteoporotic spine as torque forces required for subsidence of cages are nearly three times higher than those needed for fixation. Most of the expansion load is absorbed by straining of the dorsal instrumentation. Rod materials other than titanium may alter the torque forces found in this study.


Asunto(s)
Fusión Vertebral , Titanio , Humanos , Cuerpo Vertebral , Torque , Vértebras Lumbares/cirugía , Prótesis e Implantes
3.
J Pers Med ; 14(2)2024 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-38392583

RESUMEN

BACKGROUND: The recurrence or persistence of symptoms after thoracic outlet decompression (TOD) in patients with neurogenic thoracic outlet syndrome (NTOS) is not uncommon. Some authors have shown significantly better clinical outcomes in patients who underwent TOD with exarticulation of the first rib compared to a group who underwent TOD with preservation of the dorsal portion of the first rib. Several other case series have shown significant improvement after redo surgery with removal of the dorsal first rib remnant. This indicates the importance of the dorsal part of the first rib in NTOS. However, radical exarticulation may not always be necessary. In this study, we tried to answer the question of whether there is a morphological difference in the dorsal part of the first rib in NTOS patients that might help in the diagnosis and treatment of NTOS. METHODS: We used the CT data of 21 NTOS patients who underwent TOD surgery and measured the dorsal part of the first rib, then compared them with a quota sample. RESULTS: We found no difference in the dorsal part of the first rib between NTOS patients and the quota sample in our data. CONCLUSIONS: As there was no detectable difference, we were not able to use these data to help decide whether exarticulation is necessary in achieving adequate symptom relief. Therefore, we advocate exarticulation of the first rib when TOD is indicated.

4.
Clin Oral Investig ; 28(3): 182, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38424318

RESUMEN

OBJECTIVES: The present study aims to assess the impact of bilateral and high oblique sagittal split osteotomy (BSSO/HSSO), as well as displacement distances and directions on the expected and achievable bone contact area (BCA) and changes in the intercondylar distance (ICD). The primary question addressed is whether mandibular splitting through BSSO results in a greater BCA and/or ICD when compared to splitting through HSSO. MATERIALS AND METHODS: Totally 80 mandibular displacements were performed on 20 fresh cadavers, for each subject, four splints were produces to facilitate mandibular advancement as well as setbacks of 4 and 8 mm. Pre- and postoperative CBCT scans were performed to plan the surgical procedures and to analyze the expected and achieved BCA and ICD. RESULTS: Regarding the maximum mandibular displacement, the expected BCA for HSSO/BSSO were 352.58 ± 96.55mm2 and 1164.00 ± 295.50mm2, respectively, after advancement and 349.11 ± 98.42mm2 and 1344.70 ± 287.23mm2, respectively, after setback. The achieved BCA for HSSO/BSSO were 229.37 ± 75.90mm2 and 391.38 ± 189.01mm2, respectively, after advancement and 278.03 ± 97.65mm2 and 413.52 ± 169.52 mm2, respectively after setback. The expected ICD for HSSO/BSSO were 4.51 ± 0.73 mm and 3.25 ± 1.17 mm after advancement and - 5.76 ± 1.07 mm and - 4.28 ± 1.58 mm after setback. The achieved ICD for HSSO/BSSO were 2.07 ± 2.9 mm and 1.7 ± 0.60 mm after advancement and - 2.57 ± 2.78 mm and - 1.28 ± 0.84 mm after setback. Significant differences between the BCA after HSSO and BSSO were at each displacement (p < 0.001), except for the achieved BCA after 8-mm setback and advancement (p ≥ 0.266). No significant differences were observed regarding ICD, except for the expected ICD after 8-mm setback and advancement (p ≤ 0.037). CONCLUSIONS: Compared to the virtual planning, the predictability regarding BCA and ICD was limited. ICD showed smaller clinical changes, BCA decreased significantly in the BSSO group. CLINICAL RELEVANCE: BCA and ICD might have been less important in choosing the suitable split technique. in orthognathic surgery.


Asunto(s)
Maloclusión , Avance Mandibular , Cirugía Ortognática , Sitoesteroles , Humanos , Osteotomía Sagital de Rama Mandibular/métodos , Mandíbula/cirugía
5.
J Biomed Mater Res B Appl Biomater ; 112(1): e35339, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37955803

RESUMEN

Pedicle screw instrumentation has become "state of the art" in surgical treatment of many spinal disorders. Loosening of pedicle screws due to poor bone mineral density is a frequent complication in osteoporotic patients. As prevalence of osteoporosis and spinal disorders are increasing with an aging demographic, optimizing the biomechanical properties of pedicle screw constructions and therefore outcome after spinal surgery in osteoporotic patients is a key factor in future surgical therapy. Therefore, this biomechanical study investigated the stability of polymethylmethacrylate (PMMA)-augmented pedicle screw-rod constructions under a deviating distribution of PMMA applied to the instrumentation in osteoporotic human cadaveric vertebrae. We showed that PMMA-augmented pedicle screw-rod constructions tend to be more stable than those with non-augmented pedicle screws. Further, there appears to be a larger risk of screw loosening in unilateral augmented pedicle screws than in non-augmented, therefore a highly asymmetrically distributed PMMA should be avoided.


Asunto(s)
Tornillos Pediculares , Humanos , Polimetil Metacrilato , Vértebras Lumbares/cirugía , Fenómenos Biomecánicos , Cementos para Huesos
6.
Arch Orthop Trauma Surg ; 144(3): 1047-1053, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38114739

RESUMEN

INTRODUCTION: Avoiding overlengthening in radial head arthroplasty (RHA) is essential for the prognosis of the elbow joint. An overlengthening from 2 mm is visible due to widening of the anterolateral ulnohumeral joint space but intraoperatively, this particular joint space is difficult to visualize. The commonly used Kocher approach allows visualization of the posterolateral joint space without additional instruments or further surgical release of the already unstable elbow. The aim of our study was to investigate whether the visualization of the posterolateral joint space is also a reliable method to indicate overlengthening in RHA. MATERIAL AND METHODS: RHA was performed in five human cadaveric specimens with the forearm, wrist, and hand intact. The lateral ligament complex was detached and an anatomic transosseous refixation was performed. Six stages of implantation heights were documented: native joint (1), RHA at the anatomic height (2), + 2 mm (3), + 4 mm (4), + 6 mm (5) and - 2 mm (6). Macroscopic measurement and digital image analysis of the posterolateral and anterolateral ulnohumeral joint spaces were performed. RESULTS: All stages of overlengthening showed a significant increase in posterolateral and anterolateral joint space widening (p < 0.05). The posterior and anterior joint space showed excellent intraclass correlation. CONCLUSION: Visualization of the posterolateral aspect of the ulnohumeral joint space is a reliable indicator for overlengthening in RHA without further compromising an already unstable elbow. Correlation to the findings of the anterolateral ulnohumeral joint space in different implants leads to the assumption that visualization of either the anterior or posterior ulnohumeral joint space is universally applicable to determine overlengthening in RHA, regardless of the type of the radial head implant.


Asunto(s)
Articulación del Codo , Fracturas del Radio , Humanos , Radio (Anatomía)/cirugía , Articulación del Codo/cirugía , Artroplastia , Fracturas del Radio/diagnóstico por imagen , Fracturas del Radio/cirugía , Codo/cirugía
7.
Clin Biomech (Bristol, Avon) ; 109: 106075, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37651900

RESUMEN

BACKGROUND: Vertebral body replacement is a common surgical procedure for treatment of disorders associated with spinal instability. Therefore, pedicle screws are usually inserted in adjacent vertebrae for stabilization of the posterior column, however, there is lack of evidence whether implantation of index-level pedicle screws is beneficial or not. This biomechanical study aims to investigate the effect of pedicle screw instrumentation on axial stability following vertebral body replacement. METHODS: Unstable fracture at L3 level was simulated in lumbar spines from six human cadaveric specimens. Then instrumentation was performed one level above / one level below index level in three specimens and further, three specimens were instrumented at index-level (L3) additionaly. Then we used a testing protocol for biomechanical evaluation of axial loading on human cadaveric lumbar spines until cage subsidence occurred. FINDINGS: Our results show that index-level instrumented spines endured significantly higher load until cage subsidence occurred compared to non-index-level instrumented specimens (p = 0.05). INTERPRETATION: Our results demonstrate pedicle screw instrumentation at index-level vertebra should be considered when possbile as it may have a protective effect against cage subsidence in patients undergoing vertebral body replacement surgery.

8.
Anat Sci Educ ; 16(5): 814-829, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37183973

RESUMEN

Hands-on courses utilizing preserved human tissues for educational training offer an important pathway to acquire basic anatomical knowledge. Owing to the reevaluation of formaldehyde limits by the European Commission, a joint approach was chosen by the German-speaking anatomies in Europe (Germany, Austria, Switzerland) to find commonalities among embalming protocols and infrastructure. A survey comprising 537 items was circulated to all anatomies in German-speaking Europe. Clusters were established for "ethanol"-, formaldehyde-based ("FA"), and "other" embalming procedures, depending on the chemicals considered the most relevant for each protocol. The logistical framework, volumes of chemicals, and infrastructure were found to be highly diverse between the groups and protocols. Formaldehyde quantities deployed per annum were three-fold higher in the "FA" (223 L/a) compared to the "ethanol" (71.0 L/a) group, but not for "other" (97.8 L/a), though the volumes injected per body were similar. "FA" was strongly related to table-borne air ventilation and total fixative volumes ≤1000 L. "Ethanol" was strongly related to total fixative volumes >1000 L, ceiling- and floor-borne air ventilation, and explosion-proof facilities. Air ventilation was found to be installed symmetrically in the mortuary and dissection facilities. Certain predictors exist for the interplay between the embalming used in a given infrastructure and technical measures. The here-established cluster analysis may serve as decision supportive tool when considering altering embalming protocols or establishing joint protocols between institutions, following a best practice approach to cater toward best-suited tissue characteristics for educational purposes, while simultaneously addressing future demands on exposure limits.


Asunto(s)
Anatomía , Humanos , Fijadores , Anatomía/educación , Embalsamiento/métodos , Cadáver , Formaldehído/química , Etanol
9.
Heliyon ; 9(4): e14117, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37057051

RESUMEN

Introduction: During the SARS-CoV-2-pandemic, face masks have become one of the most important ubiquitous factors affecting human breathing. It increases the resistance and dead space volume leading to a re-breathing of CO2. So far, this phenomenon and possible implications on early life has not been evaluated in depth. Method: As part of a scoping review, literature was systematically reviewed regarding CO2 exposure and facemask use. Results: Fresh air has around 0.04% CO2, while wearing masks more than 5 min bears a possible chronic exposure to carbon dioxide of 1.41% to 3.2% of the inhaled air. Although the buildup is usually within the short-term exposure limits, long-term exceedances and consequences must be considered due to experimental data. US Navy toxicity experts set the exposure limits for submarines carrying a female crew to 0.8% CO2 based on animal studies which indicated an increased risk for stillbirths. Additionally, mammals who were chronically exposed to 0.3% CO2 the experimental data demonstrate a teratogenicity with irreversible neuron damage in the offspring, reduced spatial learning caused by brainstem neuron apoptosis and reduced circulating levels of the insulin-like growth factor-1. With significant impact on three readout parameters (morphological, functional, marker) this chronic 0.3% CO2 exposure has to be defined as being toxic. Additional data exists on the exposure of chronic 0.3% CO2 in adolescent mammals causing neuron destruction, which includes less activity, increased anxiety and impaired learning and memory. There is also data indicating testicular toxicity in adolescents at CO2 inhalation concentrations above 0.5%. Discussion: There is a possible negative impact risk by imposing extended mask mandates especially for vulnerable subgroups. Circumstantial evidence exists that extended mask use may be related to current observations of stillbirths and to reduced verbal motor and overall cognitive performance in children born during the pandemic. A need exists to reconsider mask mandates.

10.
Front Public Health ; 11: 1125150, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37089476

RESUMEN

Background: As face masks became mandatory in most countries during the COVID-19 pandemic, adverse effects require substantiated investigation. Methods: A systematic review of 2,168 studies on adverse medical mask effects yielded 54 publications for synthesis and 37 studies for meta-analysis (on n = 8,641, m = 2,482, f = 6,159, age = 34.8 ± 12.5). The median trial duration was only 18 min (IQR = 50) for our comprehensive evaluation of mask induced physio-metabolic and clinical outcomes. Results: We found significant effects in both medical surgical and N95 masks, with a greater impact of the second. These effects included decreased SpO2 (overall Standard Mean Difference, SMD = -0.24, 95% CI = -0.38 to -0.11, p < 0.001) and minute ventilation (SMD = -0.72, 95% CI = -0.99 to -0.46, p < 0.001), simultaneous increased in blood-CO2 (SMD = +0.64, 95% CI = 0.31-0.96, p < 0.001), heart rate (N95: SMD = +0.22, 95% CI = 0.03-0.41, p = 0.02), systolic blood pressure (surgical: SMD = +0.21, 95% CI = 0.03-0.39, p = 0.02), skin temperature (overall SMD = +0.80 95% CI = 0.23-1.38, p = 0.006) and humidity (SMD +2.24, 95% CI = 1.32-3.17, p < 0.001). Effects on exertion (overall SMD = +0.9, surgical = +0.63, N95 = +1.19), discomfort (SMD = +1.16), dyspnoea (SMD = +1.46), heat (SMD = +0.70), and humidity (SMD = +0.9) were significant in n = 373 with a robust relationship to mask wearing (p < 0.006 to p < 0.001). Pooled symptom prevalence (n = 8,128) was significant for: headache (62%, p < 0.001), acne (38%, p < 0.001), skin irritation (36%, p < 0.001), dyspnoea (33%, p < 0.001), heat (26%, p < 0.001), itching (26%, p < 0.001), voice disorder (23%, p < 0.03), and dizziness (5%, p = 0.01). Discussion: Masks interfered with O2-uptake and CO2-release and compromised respiratory compensation. Though evaluated wearing durations are shorter than daily/prolonged use, outcomes independently validate mask-induced exhaustion-syndrome (MIES) and down-stream physio-metabolic disfunctions. MIES can have long-term clinical consequences, especially for vulnerable groups. So far, several mask related symptoms may have been misinterpreted as long COVID-19 symptoms. In any case, the possible MIES contrasts with the WHO definition of health. Conclusion: Face mask side-effects must be assessed (risk-benefit) against the available evidence of their effectiveness against viral transmissions. In the absence of strong empirical evidence of effectiveness, mask wearing should not be mandated let alone enforced by law. Systematic review registration: https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42021256694, identifier: PROSPERO 2021 CRD42021256694.


Asunto(s)
COVID-19 , Dispositivos de Protección Respiratoria , Humanos , Adulto Joven , Adulto , Persona de Mediana Edad , COVID-19/epidemiología , Máscaras , SARS-CoV-2 , Pandemias , Dióxido de Carbono , Síndrome Post Agudo de COVID-19 , Disnea
11.
J Anat ; 243(1): 138-147, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36863846

RESUMEN

The craniocervical junction (CCJ) of humans and other vertebrates is a developmental restless region. Due to complex phylogenetic and ontogenetic processes, many anatomical variations can be found in that transitional area. Therefore, newly described variants must be registered, named, and classified into existing concepts explaining their genesis. This study aimed to describe and classify anatomical peculiarities that have not or rarely been reported on before in the literature. This study is based on the observation, analysis, classification, and documentation of three rare phenomena of three different human skull bases and upper cervical vertebrae, which come from the body donor program of the RWTH Aachen. As a result, three osseous phenomena (accessory ossicles, spurs, and bridges) at the CCJ of three different body donors could have been documented, measured, and interpreted. Due to extensive collecting efforts, careful maceration, and accurate observation, it is still possible to add new phenomena to the long list of Proatlas-manifestations. Further on, it could have been shown again that these manifestations can cause damage to the elements of the CCJ due to altered biomechanic conditions. Finally, we have succeeded in showing that phenomena can exist that can imitate the presence of a Proatlas-manifestation. Here, a precise differentiation between Proatlas-based supernumerary structures and the results of fibroostotic processes is necessary.


Asunto(s)
Vértebras Cervicales , Hueso Occipital , Humanos , Filogenia , Base del Cráneo
12.
Clin Biomech (Bristol, Avon) ; 103: 105925, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36863219

RESUMEN

INTRODUCTION: Despite good screw anchorage and safe screw trajectory, screw loosening occurs in several cases, especially in osteoporotic individuals. The aim of this biomechanical analysis was to evaluate the primary stability of revision screw placement in individuals with reduced bone quality. Therefore, revision via enlarged diameter screws was compared to the use of human bone matrix as augmentation to improve the bone stock and screw coverage. METHODS: 11 lumbar vertebral bodies from cadaveric specimens with a mean age of 85.7 years (± 12.0 years) at death were used. 6.5 mm diameter pedicle screws were inserted in both pedicles and hereafter loosened using a fatigue protocol. Screws were revised inserting a larger diameter screw (8.5 mm) in one pedicle and a same diameter screw with human bone matrix augmentation in the other pedicle. The previous loosening protocol was then reapplied, comparing maximum load and cycles to failure between both revision techniques. Insertional torque was continuously measured during insertion of both revision screws. FINDINGS: The number of cycles and the maximum load until failure were significantly greater in enlarged diameter screws than in augmented screws. The enlarged screws' insertional torque was also significantly higher than of the augmented screws. INTERPRETATION: Human bone matrix augmentation does not reach the same ad-hoc fixation strength as enlarging the screw's diameter by 2 mm and is therefore biomechanically inferior. Regarding the immediate stability, a thicker screw should therefore be prioritised.


Asunto(s)
Osteoporosis , Tornillos Pediculares , Humanos , Anciano de 80 o más Años , Matriz Ósea , Huesos , Vértebras Lumbares/cirugía , Osteoporosis/cirugía , Fenómenos Biomecánicos , Cementos para Huesos , Cadáver
13.
J Pers Med ; 13(1)2023 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-36675805

RESUMEN

Purpose: The failure rate for operative decompression in neurogenic thoracic outlet syndrome (NTOS) is high compared to more distal nerve compression syndromes, such as cubital or carpal tunnel syndrome. Herein, we aimed to determine if a more radical approach, namely costovertebral exarticulation of the first rib, may improve the postoperative results in patients with NTOS. Methods: From October 2002 to December 2020, 105 operative decompressions in 95 patients were evaluated; in 10 cases, decompressions were performed bilaterally. We presented the clinical outcomes of 59 exarticulations compared to those of 46 conventional resections. Evaluation was performed at a minimum of one year post-operation using the DASH questionnaire. Results: The exarticulation group presented with significantly better clinical outcomes (two-sample t-test assuming unequal variances, p < 0.001). Conclusions: This study showed that significantly better results were obtained when exarticulation of the first rib was performed in patients with NTOS. This finding supports the hypothesis that, in certain cases, the proximal portion of the first rib plays a pivotal role in the pathogenesis of NTOS.

14.
Clin Biomech (Bristol, Avon) ; 101: 105867, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36584578

RESUMEN

BACKGROUND: Knee Spacers are required in two-stage revision surgery of periprosthetic joint infection of the knee. Extended bone and ligamentous defects are often temporarily arthrodised via a static spacer. Regarding their weight-bearing potential and construction, there is no current consent. Our aim was to evaluate three individual static spacer variants with regard to their axial loading capacity. METHODS: The static spacer variants were tested in a cadaver model. One after the other, a spacer with metal-reinforced rods, a spacer without metal reinforcement and a rod-less spacer were implanted and tested up to an axial loading of 1000 Newton. Target parameters were plastic deformation, stiffness and spacer movement at both the femoral and tibial surface. Loading was applied up to 1000 Newton. Radiological controls of the bone substance were performed. FINDINGS: The spacer variants did not differ regarding deformation, stiffness or spacer movement. However, deformation increased significantly with the axial load in all spacer variants. Radiographs showed no fracture or spacer-dislocation resulting from testing. INTERPRETATION: While the spacer reinforcement or the sheer presence of a rod did not influence the axial loading capacity in this in vitro study, weightbearing should be discouraged to limit further bone erosion.


Asunto(s)
Artritis Infecciosa , Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Articulación de la Rodilla/cirugía , Tibia/cirugía , Fémur/cirugía , Artritis Infecciosa/cirugía , Reoperación/métodos
15.
Acta Chir Belg ; 123(6): 699-706, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36259265

RESUMEN

BACKGROUND: Meckel's diverticula result from incomplete obliteration and regression of the omphaloenteric duct and are the most common congenital intestinal malformations. Many Meckel's diverticula remain asymptomatic and are discovered as incidental findings. They present a diagnostic challenge. METHODS: We report the case of a 35-year-old man who presented with an acute abdomen and ileus. Computed tomography of the abdomen showed a mechanical small bowel ileus. There was a calibre jump in the terminal ileum with a round endoluminal definable hyperdense structure of almost 2 cm in diameter. RESULTS: An exploratory laparoscopy was performed revealing an inflamed Meckel's diverticulum with impacted enterolith as the cause of the intestinal obstruction. CONCLUSION: In symptomatic Meckel's diverticula, haemorrhage and obstruction are the most common complications. The development of ileus due to a Meckel's diverticulum with an enterolith is considered extremely rare but should be taken into account.


Asunto(s)
Cavidad Abdominal , Ileus , Obstrucción Intestinal , Divertículo Ileal , Masculino , Humanos , Adulto , Divertículo Ileal/diagnóstico , Divertículo Ileal/diagnóstico por imagen , Obstrucción Intestinal/diagnóstico por imagen , Obstrucción Intestinal/etiología , Obstrucción Intestinal/cirugía , Ileus/diagnóstico por imagen , Ileus/etiología , Ileus/cirugía , Tomografía Computarizada por Rayos X
16.
Arch Orthop Trauma Surg ; 143(5): 2485-2491, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-35635575

RESUMEN

BACKGROUND: Complex proximal humeral fracture ranks among the most common fracture types, especially in elderly patients. In locked plate fixation of proximal humerus fractures, the calcar is deciding for screws providing further medial column support. To date, the biomechanical effect of the length of these calcar screws is not well known. The purpose of this study was to analyze the effect of long calcar screws on fresh frozen prefractured cadaveric specimens. METHODS: In the present biomechanical study, 8 pairs of cadaveric proximal humeri were fractured identically using a custom-made fracture simulator. ORIF was performed using a locking plate (PHILOS; Fa. Synthes). The specimens were tested in a biomechanical setup under increased axial load without any calcar screws installed, with short calcar screws and long calcar screws installed. Strain gages (4-wire-120 Ohm, Fa. Vishay) mounted on the locking plate were used to evaluate the fixation strain and to give an estimate for primary stability.. RESULTS: The measured strain of the locking plate without calcar screws (804,64 µm/m) at maximum load (200 N) was significantly higher than with short (619,07 µm/m; p = 0.02) or long calcar screws (527,31 µm/m; p = 0.007). Additionally, strain with short calcar screws was noticeably higher in comparison to long calcar screws (619,07 µm/m vs. 527,31 µm/m; p = 0.03). CONCLUSION: Use of calcar screws improves the stability of realistically impacted 3-part varus humeral fractures. Long calcar screws that are positioned as close as possible to the joint provide further primary stability compared to short calcar screws. LEVEL OF EVIDENCE: Basic science study.


Asunto(s)
Fijación Interna de Fracturas , Fracturas del Hombro , Humanos , Anciano , Tornillos Óseos , Fracturas del Hombro/cirugía , Húmero/cirugía , Placas Óseas , Cadáver , Fenómenos Biomecánicos
17.
Eur J Med Res ; 27(1): 270, 2022 Dec 03.
Artículo en Inglés | MEDLINE | ID: mdl-36463220

RESUMEN

BACKGROUND: The surgical treatment of inferior patellar pole fractures can be a challenge, especially in geriatric patients, who are particularly frequently affected by osteoporosis. The objective of this biomechanical study was to compare the performance of suture anchor and transosseous suture fixation in fractures of the inferior patellar pole in context of bone mineral density. METHODS: Twelve fresh-frozen human cadaveric knees received a transverse osteotomy, simulating an AO/OTA 34C1.3 inferior pole fracture of the patella. These fractures were fixated with either suture anchors (SA; Corkscrew® FT 4.5 mm) or transosseous suture (TS; #2 FiberWire®). Cyclic loading tests were performed by pulling the quadriceps tendon against gravity from 90° flexion to almost full extension (5°) for 1000 cycles. Motion and fracture gap displacement were tracked until failure occurred. Subsequently, loading to failure tests followed. Differences between groups were compared using unpaired t-tests, and correlations were calculated with Pearson's correlation coefficient. RESULTS: The suture anchor group showed significantly fewer cycles to failure than the transosseous suture group (SA: 539.0 ± 465.6 cycles, TS: 1000 ± 0 cycles, P = 0.04). Bone mineral density correlated positively with cycles to failure in the suture anchor group (Pearson's r = 0.60, P = 0.02). No differences in fracture gap displacement could be proven after 100 cycles (SA: 4.1 ± 2.6 mm, TS: 6.5 ± 2.6 mm, P = 0.19); 500 cycles (SA: 6.4 ± 6.1 mm, TS: 9.6 ± 3.8 mm, P = 0.39); and 1000 cycles (SA: 4.0 ± 0.4 mm, TS: 11.0 ± 4.5 mm, P = 0.08). Furthermore, the mean destructive load to failure in the suture anchor group was also significantly lower than in the transosseous suture group (SA: 422.4 ± 212.2 N, TS: 825.7 ± 189.3 N, P = 0.04). CONCLUSIONS: Suture anchors may be a viable alternative to transosseous suture in younger patients for clinical advantages, but in osteoporotic bone, the more stable osteosynthesis with transosseous suture continues to prove superior. Therefore, trauma surgeons might consider the use of transosseous suture in elderly patients, especially in those presenting with low bone mineral density values.


Asunto(s)
Fracturas Óseas , Osteoporosis , Anciano , Humanos , Rótula/cirugía , Anclas para Sutura , Fracturas Óseas/cirugía , Suturas , Osteoporosis/cirugía
18.
Sci Rep ; 12(1): 11858, 2022 07 13.
Artículo en Inglés | MEDLINE | ID: mdl-35831396

RESUMEN

Magnetic resonance imaging (MRI) is commonly used to assess traumatic and non-traumatic conditions of the knee. Due to its complex and variable anatomy, the posterolateral corner (PLC)-often referred to as the joint's dark side-remains diagnostically challenging. We aimed to render the diagnostic evaluation of the PLC more functional by combining MRI, varus loading, and image post-processing in a model of graded PLC injury that used sequential transections of the lateral collateral ligament, popliteus tendon, popliteofibular ligament, and anterior cruciate ligament. Ten human cadaveric knee joint specimens underwent imaging in each condition as above, and both unloaded and loaded using an MR-compatible device that standardized loading (of 147 N) and position (at 30° flexion). Following manual segmentation, 3D joint models were used to computationally measure lateral joint space opening for each specimen, configuration, and condition, while manual measurements provided the reference standard. With more extensive ligament deficiency and loading, lateral joint spaces increased significantly. In conclusion, varus stress MRI allows comprehensive PLC evaluation concerning structural integrity and associated functional capacity. Beyond providing normative values of lateral compartment opening, this study has potential implications for diagnostic and surgical decision-making and treatment monitoring in PLC injuries.


Asunto(s)
Ligamento Cruzado Anterior , Articulación de la Rodilla , Cadáver , Humanos , Imagen por Resonancia Magnética , Rango del Movimiento Articular
19.
JMIR Serious Games ; 10(2): e34781, 2022 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-35468090

RESUMEN

BACKGROUND: Although nearly one-third of the world's disease burden requires surgical care, only a small proportion of digital health applications are directly used in the surgical field. In the coming decades, the application of augmented reality (AR) with a new generation of optical-see-through head-mounted displays (OST-HMDs) like the HoloLens (Microsoft Corp) has the potential to bring digital health into the surgical field. However, for the application to be performed on a living person, proof of performance must first be provided due to regulatory requirements. In this regard, cadaver studies could provide initial evidence. OBJECTIVE: The goal of the research was to develop an open-source system for AR-based surgery on human cadavers using freely available technologies. METHODS: We tested our system using an easy-to-understand scenario in which fractured zygomatic arches of the face had to be repositioned with visual and auditory feedback to the investigators using a HoloLens. Results were verified with postoperative imaging and assessed in a blinded fashion by 2 investigators. The developed system and scenario were qualitatively evaluated by consensus interview and individual questionnaires. RESULTS: The development and implementation of our system was feasible and could be realized in the course of a cadaver study. The AR system was found helpful by the investigators for spatial perception in addition to the combination of visual as well as auditory feedback. The surgical end point could be determined metrically as well as by assessment. CONCLUSIONS: The development and application of an AR-based surgical system using freely available technologies to perform OST-HMD-guided surgical procedures in cadavers is feasible. Cadaver studies are suitable for OST-HMD-guided interventions to measure a surgical end point and provide an initial data foundation for future clinical trials. The availability of free systems for researchers could be helpful for a possible translation process from digital health to AR-based surgery using OST-HMDs in the operating theater via cadaver studies.

20.
Diagnostics (Basel) ; 12(3)2022 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-35328240

RESUMEN

For T2 mapping, the underlying mono-exponential signal decay is traditionally quantified by non-linear Least-Squares Estimation (LSE) curve fitting, which is prone to outliers and computationally expensive. This study aimed to validate a fully connected neural network (NN) to estimate T2 relaxation times and to assess its performance versus LSE fitting methods. To this end, the NN was trained and tested in silico on a synthetic dataset of 75 million signal decays. Its quantification error was comparatively evaluated against three LSE methods, i.e., traditional methods without any modification, with an offset, and one with noise correction. Following in-situ acquisition of T2 maps in seven human cadaveric knee joint specimens at high and low signal-to-noise ratios, the NN and LSE methods were used to estimate the T2 relaxation times of the manually segmented patellofemoral cartilage. In-silico modeling at low signal-to-noise ratio indicated significantly lower quantification error for the NN (by medians of 6−33%) than for the LSE methods (p < 0.001). These results were confirmed by the in-situ measurements (medians of 10−35%). T2 quantification by the NN took only 4 s, which was faster than the LSE methods (28−43 s). In conclusion, NNs provide fast, accurate, and robust quantification of T2 relaxation times.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...