Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Mikrochim Acta ; 190(8): 299, 2023 07 18.
Artículo en Inglés | MEDLINE | ID: mdl-37462815

RESUMEN

A chromatographic system based on in-tube SPME coupled to capillary LC-DAD has been used to study the synthesis of silver nanoparticles using polyphenols in different scenarios: excess of the reducing agent or of the silver salt, addition of the cationic surfactants, and thermal synthesis. The optimized synthesis conditions allowed to quantify the polyphenols used as reducing agents, such as Trolox and chlorogenic acid. Two chromatographic peaks with different absorption spectrum were monitored during the syntheses. Depending on the molar relationship, a linear relation between the area of the chromatographic peaks and the concentration of the silver or polyphenol was established. For stabilization of silver nanoparticles, different cationic surfactants were used allowing to evaluate the role of anion (chloride and bromide) and of the alkyl chain. The proposed methodology can be used to determine chlorogenic acid up to 3 mM with a detection limit of 34 µM at λ= 400 nm. Chlorogenic acid was determined in dietary products with successful results. Precision (RSD=10%) and recovery (97-100%) were also satisfactory.


Asunto(s)
Antioxidantes , Nanopartículas del Metal , Ácido Clorogénico , Microextracción en Fase Sólida/métodos , Plata/química , Nanopartículas del Metal/química , Límite de Detección , Cromatografía Liquida/métodos , Tensoactivos , Polifenoles
2.
Talanta ; 255: 124228, 2023 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-36587429

RESUMEN

In this work, a retention behavior based on mixed-mode reversed-phase (RP)/hydrophilic interaction liquid chromatography (HILIC) was observed for benzalkonium chloride (BAK) using a core-shell column functionalized with biphenyl groups. Although in the literature, the U-shaped retention was reported for polar compounds in mixed functionalized phases, in the present work, the behavior was dependent upon the chemical structure of the analyte with mixed functionality (ammonium group, a benzyl group and an alkyl chain) and on the high selectivity of the chromatographic column. The bimodal retention was observed for the four BAK homologues using a content of acetonitrile from 65 to 95% in the mobile phase. The data were adjusted to polynomial equations which allow for modeling and predicting the U-shaped retention. The salt concentration (50 and 100 mM), anion (formate and acetate) and cation (ammonium and triethylammonium) of the salt, pH (4 and 5) in the mobile phase were studied in order to understand their influence on the two retention modes. Significant electrostatic interactions were involved in the two retention modes, especially with a content of acetonitrile higher that 90%. Linear relationships between the retention factors of the four homologues were found in a wide range of %acetonitrile when the salt and triethylamine concentration, pH and nature of salt were changed. The differences found on the retention of the homologues, when increasing the alkyl chain length, were more significant in the RP mode due to predominant hydrophobic interactions. A pH decrease and a salt concentration increase caused a retention decrease for both modes. A decrease on of the retention was observed when acetate anion was replaced by formate anion. The different order of the polynomial equations according to the used mobile phase confirmed its relevant role in the interactions with the analytes and stationary phase. A mobile phase was selected (85% acetonitrile, pH 4 and 100 mM ammonium formate) for the BAK determination in cutaneous, otic and ophthalmic formulations with different active pharmaceutical ingredients and excipients. Low sample volume (500 µL) and short analysis time (<5 min) were some of the advantages of the proposed method. In addition, good analytical performance (R2 > 0.999, % RSD <4.5% for intra-day precision and <5.8% for inter-day precision, and recoveries in the 92-105% range) was obtained.


Asunto(s)
Compuestos de Benzalconio , Cromatografía de Fase Inversa , Composición de Medicamentos , Cromatografía de Fase Inversa/métodos , Acetonitrilos/química , Interacciones Hidrofóbicas e Hidrofílicas , Aniones
3.
Environ Pollut ; 265(Pt A): 114911, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32534238

RESUMEN

The presence of ammonium ion in rainwater is due to atmospheric processes which involve its scavenging from gas phase and particulate matter. The fractionated samplings of rainwater can provide information about these processes and their potential sources. However, only a low sample volume may be available, which constrained the analysis in general and more particularly in situ mode. For minimizing this limitation, this work proposes a polydimethylsiloxane (PDMS)-salicylate sensor that produces a color change. The embedding of solid reagents into PDMS was optimized. Good analytical characteristics (analysis time of 10 min, sample volume of 500 µL, limit of detection 0.03 µgmL-1) were obtained. Furthermore, other features of the method such as carbon footprint, equipment cost, residues, toxicity and safety have to be taken into account to be assessed according to the Green Analytical Chemistry approach. In this sense, the hexagon tool was employed for comparing the proposed sensor with methods based on the same reaction as well as with general methods for the ammonium analysis in water (using luminol, ion selective electrode, Nessler and modified Roth method). The proposed method based on PDMS-salicylate sensor stands out from all the others by its sustainability, particularly, in terms of low carbon footprint, residues and cost. The method was applied to fractionated samplings in a suburban site (Galicia, Northwestern Spain) and a higher contribution of the rainout process was observed. When long-duration rain events were analyzed, a relationship between the sampling time and ammonium concentration could indicate a loss of ammonium ion over time. The research focuses on developing an innovative PDMS-sensor, for monitoring ammonium determination in rainwater under wide conditions (scavenging process).


Asunto(s)
Compuestos de Amonio , Análisis Costo-Beneficio , Dimetilpolisiloxanos , Lluvia , España
4.
Talanta ; 198: 371-376, 2019 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-30876574

RESUMEN

Two of the reagents involved in the Berthelot's reaction, thymol and nitroprusside, were embedded in a PDMS composite in order to apply this assay to determine ammonium and proline, in wine and beers. Safety, portability, rapidity, cost-effectiveness and simplicity of the assay were improved. For the proline determination, a modified Berthelot's reaction, which included a ring cleavage of proline, was optimized. The accuracy of the assay was tested. The limits of detection for ammonium was 0.12 µg mL-1 and for proline was in the range from 0.7 to 4.1 µg mL-1, depending on the kind of wine (white, red, or sweet), for beer the LOD was 6 µg mL-1. The precision achieved was slower than 10%. The accuracy of the assay was tested by means of a confirmatory validation study. Good results were obtained for real samples.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...