Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Talanta ; 273: 125866, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38490025

RESUMEN

The global increase in population aging has led to a rise in neurodegenerative diseases (NDs), posing significant challenges to public health. Developing selective and specific biomarkers for early diagnosis and drug development is crucial addressing the growing burden of NDs. In this context, the RNA-binding protein TDP-43 has emerged as a promising biomarker for amyotrophic lateral sclerosis (ALS), frontotemporal lobar degeneration (FTLD), and TDP-43-associated proteinopathies. However, existing detection methods suffer from limitations such as cost, complexity, and operator dependence. Here, we present a novel electrochemical biosensor integrated into a lab-on-chip (LoC) platform to detect TDP-43. The sensor utilizes electrosynthesized polypyrrole derivatives with carboxylic groups for transducer functionalization, enabling targeted immobilization of TDP-43 antibodies. Differential pulsed voltammetry (DPV) is used for the indirect detection and quantification of TDP-43. The chip exhibits rapid response, good reproducibility, a linear detection range, and sensitivity from 0.01 ng/mL to 25 ng/mL of TDP-43 protein concentration with a LOD = 10 pg/mL. Furthermore, successful TDP-43 detection in complex matrices like serum of ALS patients and healthy individuals demonstrates its potential as a point-of-care diagnostic device. This electrochemical biosensor integrated into a chip offers good sensitivity, rapid response, and robust performance, providing a promising avenue for advancing neurodegenerative disease diagnostics and therapeutic development.


Asunto(s)
Esclerosis Amiotrófica Lateral , Técnicas Biosensibles , Enfermedades Neurodegenerativas , Humanos , Esclerosis Amiotrófica Lateral/diagnóstico , Esclerosis Amiotrófica Lateral/metabolismo , Polímeros , Reproducibilidad de los Resultados , Inmunoensayo , Pirroles , Proteínas de Unión al ADN/metabolismo , Biomarcadores/metabolismo
3.
Analyst ; 148(18): 4447-4455, 2023 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-37599598

RESUMEN

Oral cancer is one of the most common types of cancer in Europe and its large diffusion requires, together with prevention, the development of low-cost and reliable portable platforms for its diagnosis, with features of high selectivity and sensitivity. In this study, the development and characterization of a molecularly imprinted polymer (MIP)-based electrochemical sensor for TGF-ß1 detection are reported. The optimized biosensor is a potential tool for the early screening of oral cancer. A biomimetic surface has been obtained by electropolymerization of o-phenylenediamine (o-PD) on platinum electrodes, in the presence of TGF-ß1 as a template molecule. MIP synthesis, template removal and TGF-ß1 rebinding have been monitored by Differential Pulse Voltammetry (DPV). Atomic Force Microscopy (AFM) has been performed to investigate and characterize the surface morphology and the influence of the washing step on MIP and NIP (non-imprinted polymer as the control) while the thickness of the polymer layer has been measured by Scanning Transmission Electron Microscopy (STEM) analysis. The MIP sensor performance has been tested in both buffer solution and saliva samples with TGF-ß1, showing a linear response in the considered range (from 20 ng ml-1 down to 0.5 ng ml-1), an outstanding LOD of 0.09 ng mL-1 and affinity and selectivity to TGF-ß1 also in the presence of interfering molecules. The sensor was used also for the detection of target molecules in spiked saliva samples with good recovery results suggesting the possibility of the use of the proposed system for large scale fast screening in oral cancer diagnosis.


Asunto(s)
Polímeros Impresos Molecularmente , Neoplasias de la Boca , Humanos , Factor de Crecimiento Transformador beta1 , Neoplasias de la Boca/diagnóstico , Polímeros , Biopsia Líquida
4.
Materials (Basel) ; 16(4)2023 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-36837327

RESUMEN

The removal of pollutants, such as heavy metals, aromatic compounds, dyes, pesticides and pharmaceuticals, from water is still an open challenge. Many methods have been developed and exploited for the purification of water from contaminants, including photocatalytic degradation, biological treatment, adsorption and chemical precipitation. Absorption-based techniques are still considered among the most efficient and commonly used approaches thanks to their operational simplicity. In recent years, polydopamine-coated magnetic nanoparticles have emerged for the uptake of heavy metals in water treatment, since they combine specific affinity towards pollutants and magnetic separation capacity. In this context, this work focuses on the synthesis of polydopamine (PDA)-coated Super Paramagnetic Iron Oxide Nanoparticles (PDA@SPIONs) as adsorbents for Cu2+ ions, designed to serve as functional nanostructures for the removal of Cu2+ from water by applying a magnetic field. The synthetic parameters, including the amount of SPIONs and PDA, were thoroughly investigated to define their effects on the nanostructure features and properties. Subsequently, the ability of the magnetic nanostructures to bind metal ions was assessed on Cu2+-containing solutions. A systematic investigation of the prepared functional nanostructures was carried out by means of complementary spectroscopic, morphological and magnetic techniques. Inductively coupled plasma atomic emission spectroscopy (ICP-AES) measurements were performed in order to estimate the Cu2+ binding ability. The overall results indicate that these nanostructures hold great promise for future bioremediation applications.

5.
Nanomaterials (Basel) ; 12(21)2022 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-36364523

RESUMEN

The growing interest in piezoresistive sensors has favored the development of numerous approaches and materials for their fabrication. Within this framework, carbon nanotubes (CNTs) are often employed. However, CNTs are a heterogeneous material with different morphological characteristics in terms of length and diameter, and, so far, experimental studies have not usually considered the effect of these parameters on the final sensor performances. Here, we observe how, by simply changing the CNTs length in a solvent-free mechanochemistry fabrication method, different porous 3D elastomeric nanocomposites with different electrical and mechanical properties can be obtained. In particular, the use of longer carbon nanotubes allows the synthesis of porous nanocomposites with better mechanical stability and conductivity, and with a nine-times-lower limit of detection (namely 0.2 Pa) when used as a piezoresistive sensor. Moreover, the material prepared with longer carbon nanotubes evidenced a faster recovery of its shape and electrical properties during press/release cycles, thus allowing faster response at different pressures. These results provide evidence as to how CNTs length can be a key aspect in obtaining piezoresistive sensors with better properties.

6.
Micromachines (Basel) ; 13(9)2022 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-36143994

RESUMEN

The possibility of fabricating micrometric pore size membranes is gaining great interest in many applications, from studying cell signaling, to filtration. Currently, many technologies are reported to fabricate such microsystems, the choice of which depends strictly on the substrate material and on the final application. Here, we demonstrate the capability with a single femtosecond laser source and experimental setup to fabricate micromembranes both on polymeric and multilayer metallic substrate, without the need for moulds, mask, and complex facilities. In particular, the flexibility of laser drilling was exploited to obtain microfilters with pore size of 8 and 18 µm in diameter, on metallic and polymeric substrate, respectively, and controlled distribution. For evaluating the possibility to use such laser-fabricated membranes into biological assay, their biocompatibility has been investigated. To this aim, as a proof of concept, we tested the two materials into viability tests. The culture of mammalian cells on these microfabricated membranes were studied showing their compatibility with cells.

7.
MethodsX ; 9: 101759, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35774416

RESUMEN

The Liquid Biopsy (LB) is an opportunity for non-invasive diagnosis and prognosis of various diseases. To date, it isn't possible to consider that tissue biopsy can represent a pathology entirety. Then, body fluids are rich in a large number and variety of biomarkers and they can provide information about several diseases.•Recently, other biological fluids, easy to be collected are rising for their significant content of biomarkers and for the possibility to collect and manipulate them without the intervention of medical staff.•The management of biological fluids requires suitable storage methods. Temperature, storage time and physical stresses due to sample handling can lead to chemical and physical changes that may induce sample degradation and incorrect analysis.•The reliability of a diagnostic or screening test depends on its sensitivity and specificity. As the liquid biopsy is a 'snapshot' of a pathophysiological condition, it is crucial that its components do not degrade due to the improper handling of the body fluid.In this review, some handling methods of Saliva, Urine, Stool, Seminal Fluid, Tears and Sweat samples will be described, as well as protocols to facilitate the analysis of metabolites, nucleic acids, proteins and Extracellular Vesicles (EVs) from those unusual body fluids.

8.
Nanomaterials (Basel) ; 12(7)2022 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-35407264

RESUMEN

Magnetic iron oxide nanoparticles have been extensively investigated due to their applications in various fields such as biomedicine, sensing, and environmental remediation. However, they need to be coated with a suitable material in order to make them biocompatible and to add new functionalities on their surface. This review is intended to give a comprehensive overview of recent advantages and applications of iron oxide nanoparticles coated by polydopamine film. The synthesis method of magnetic nanoparticles, their functionalization with bioinspired materials and (in particular) with polydopamine are discussed. Finally, some interesting applications of polydopamine-coated magnetic iron oxide nanoparticles will be pointed out.

9.
Micromachines (Basel) ; 13(2)2022 Jan 26.
Artículo en Inglés | MEDLINE | ID: mdl-35208305

RESUMEN

Recently, the attention paid to self-care tests and the need for easy and large-scale screenings of a high number of people has dramatically increased [...].

10.
Biosens Bioelectron ; 196: 113698, 2022 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-34688113

RESUMEN

Liquid biopsy technologies have seen a significant improvement in the last decade, offering the possibility of reliable analysis and diagnosis from several biological fluids. The use of these technologies can overcome the limits of standard clinical methods, related to invasiveness and poor patient compliance. Along with this there are now mature examples of lab-on-chips (LOC) which are available and could be an emerging and breakthrough technology for the present and near-future clinical demands that provide sample treatment, reagent addition and analysis in a sample-in/answer-out approach. The possibility of combining non-invasive liquid biopsy and LOC technologies could greatly assist in the current need for minimizing exposure and transmission risks. The recent and ongoing pandemic outbreak of SARS-CoV-2, indeed, has heavily influenced all aspects of life worldwide. Ordinary tasks have been forced to switch from "in presence" to "distanced", limiting the possibilities for a large number of activities in all fields of life outside of the home. Unfortunately, one of the settings in which physical distancing has assumed noteworthy consequences is the screening, diagnosis and follow-up of diseases. In this review, we analyse biological fluids that are easily collected without the intervention of specialized personnel and the possibility that they may be used -or not-for innovative diagnostic assays. We consider their advantages and limitations, mainly due to stability and storage and their integration into Point-of-Care diagnostics, demonstrating that technologies in some cases are mature enough to meet current clinical needs.


Asunto(s)
Técnicas Biosensibles , COVID-19 , Neoplasias , Humanos , Biopsia Líquida , Neoplasias/diagnóstico , Neoplasias/epidemiología , Pandemias , SARS-CoV-2
11.
J Colloid Interface Sci ; 607(Pt 2): 1436-1445, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34583046

RESUMEN

HYPOTHESIS: Nanocarbon/polymeric 3D porous composites have been widely developed as piezoresistive sensors due to their improved performances. Functionalized nanocarbon is usually used to allow its adsorption on the surface of porous polymeric material. However, both the functionalization and the surface localized distribution of the nanomaterial can limit the nanocarbon effect on conductivity and mechanical stability of the material thus affecting piezoresistive performances. EXPERIMENTS: A novel nanoarchitectonics strategy to prepare an elastomeric/carbon nanotubes (CNTs) 3D porous piezoresistive nanocomposite is developed. The fabrication route does not require complex apparatus and CNTs chemical functionalization. Moreover, foams of any shape and dimensions can be produced with neither complex machinery and procedures nor wastes production. FINDINGS: The obtained material is characterized by the presence of well dispersed pristine CNTs on both surface and bulk of the polymeric matrix. The foam exhibited improved piezoresistive properties with excellent compressive stress (>150 kPa), sensitivity at low displacement (29 kPa-1) and limit of detection for both pressure (2 Pa) and extension (130 nm). These excellent features could allow the use of the as prepared nanocomposite in different applications ranging from wearable devices to robotic or infrastructure monitoring with outstanding flexibility.


Asunto(s)
Nanocompuestos , Nanotubos de Carbono , Dispositivos Electrónicos Vestibles , Elastómeros , Conductividad Eléctrica
12.
Micromachines (Basel) ; 12(8)2021 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-34442507

RESUMEN

Oral cancer belongs to the group of head and neck cancers, and, despite its large diffusion, it suffers from low consideration in terms of prevention and early diagnosis. The main objective of the SMILE platform is the development of a low-cost device for oral cancer early screening with features of high sensitivity, specificity, and ease of use, with the aim of reaching a large audience of possible users and realizing real prevention of the disease. To achieve this goal, we realized two microfluidic devices exploiting low-cost materials and processes. They can be used in combination or alone to obtain on-chip sample preparation and/or detection of circulating tumor cells, selected as biomarkers of oral cancer. The realized devices are completely transparent with plug-and-play features, obtained thanks to a highly customized architecture which enables users to easily use them, with potential for a common use among physicians or dentists with minimal training.

13.
Nano Lett ; 21(14): 6179-6187, 2021 07 28.
Artículo en Inglés | MEDLINE | ID: mdl-34251835

RESUMEN

Advanced sensing tools, detecting extremely low concentrations of circulating biomarkers, can open unexplored routes toward early diagnostics and diseases progression monitoring. Here, we demonstrate the sensing capabilities of a chip-based metamaterial, combining 3D chiral geometry with a functional core-shell nanoarchitecture. The chiral metamaterial provides a circular polarization-dependent optical response, allowing analysis in a complex environment without significant background interferences. The functional nanoarchitecture, based on the conformal coating with a polymer shell, modifies the chiral metamaterial near- and far-field optical response because of the energy transfer between dielectric shell polarization charges and plasmonic core free electrons, leading to efficient interaction with biomolecules. The system sensitivity slope is 27 nm/pM, in the detection of TAR DNA-binding protein 43, clinically relevant for neurodegenerative diseases. Measurements were performed in spiked solution and in human serum with concentrations from 1 pM down to 10 fM, which is a range not accessible with common immunological assays, opening new perspectives for next-generation biomedical systems.


Asunto(s)
Dicroismo Circular , Humanos
14.
Biosensors (Basel) ; 10(6)2020 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-32549369

RESUMEN

Pectobacterium atrosepticum (Pba) is a quarantine and threatening phytopathogen known as the causal agent of blackleg and soft rot disease of potatoes in many areas. Its early detection is then important to have healthy potato tubers and reduce economic losses. Today, conventional methods such as enzyme-linked immunosorbent-assay (ELISA) and polymerase chain reaction (PCR) are typically used for Pba detection, but they are expensive and time-consuming. Here we report on the optimization of an alternative approach based on an electrochemical impedance immunosensor combining a microfluidic module and a microelectrodes array, and having advantages in terms of low cost, ease of use and portability. For validation and for assessing its performance, the lab-on-chip platform has been compared with two standard methods (ELISA and PCR).


Asunto(s)
Técnicas Biosensibles , Pectobacterium/aislamiento & purificación , Enfermedades de las Plantas/microbiología , Solanum tuberosum/microbiología , Ensayo de Inmunoadsorción Enzimática , Dispositivos Laboratorio en un Chip , Reacción en Cadena de la Polimerasa
15.
Micromachines (Basel) ; 11(5)2020 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-32403362

RESUMEN

Sustainable growth, environmental preservation, and improvement of life quality are strategic fields of worldwide interest and cornerstones of international policies. Humanity health and prosperity are closely related to our present choices on sustainable development. The main sources of pollution concern industry, including mining, chemical companies, and refineries, wastewater treatment; and consumers themselves. In order to guide and evaluate the effects of environmental policies, diffuse monitoring campaigns and detailed (big) data analyses are needed. In this respect, the development and availability of innovative sensor platforms for field analysis and remote sensing are of crucial relevance. In this review, we provide an overview of the area, analyzing the major needs, available technologies, novel approaches, and perspectives. Among environmental pollutants that threaten the biosphere, we focus on inorganic and organic contaminants, which affect air and water quality. We describe the technologies for their assessment in the environment and then draw some conclusions and mention future perspectives opened by the integration of sensing technologies with robotics and the Internet of Things. Without the ambition to be exhaustive in such a rapidly growing field, this review is intended as a support for researchers and stakeholders looking for current, state-of-the-art, and key enabling technologies for environmental monitoring.

16.
Biology (Basel) ; 9(2)2020 Jan 27.
Artículo en Inglés | MEDLINE | ID: mdl-32012799

RESUMEN

Conventional sperm selection techniques used in ARTs rely on centrifugation steps. To date, the different studies reported on the effects of centrifugation on stallion sperm motility provided contrasting results and do not include effects on mitochondrial functionality and different oxidative parameters. The effects of different centrifugation protocols (300 ×g for 5', 300 ×g for 10', 1500 ×g for 5' and 1500 ×g for 10' vs no centrifugation) on motility and oxidative status in cryopreserved stallion sperm, were analyzed. After centrifugation, almost all motility parameters were significantly altered, as observed by computer-assisted sperm analysis. A polarographic assay of oxygen consumption showed a progressive decrease in mitochondria respiration from the gentlest to the strongest protocol. By laser scanning confocal microscopy, significant reduction of mitochondrial membrane potential, at any tested protocol, and time-dependent effects, at the same centrifugal force, were found. Increased DNA fragmentation index at any tested protocol and time-dependent effects at the same centrifugal force were found, whereas increased protein carbonylation was observed only at the strongest centrifugal force. These results provide more comprehensive understandings on centrifugation-induced effects on cryopreserved stallion sperm and suggest that, even at a weak force for a short time, centrifugation impairs different aspects of equine sperm metabolism and functionality.

17.
Biotechnol Adv ; 40: 107498, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31836499

RESUMEN

Male infertility often involves idiopathic or unknown causes, leading to an increasing demand for assisted reproduction technologies (ART). Conventional sperm sorting techniques rely on centrifugation steps that are known to cause oxidative stress and consequently damage cells. Alternative novel techniques have been introduced but offer disadvantages that need to be overcome. These techniques are also employed to increase the number and the quality of subjects in the animal breeding industry, to obtain purebred subjects or to preserve endangered animal species. Microfluidics deals with the manipulation of small amounts of volume within a microdevice known as lab-on-a-chip (LOC), which offers rapid analyses, ease of use, small reagent sample volumes, high-throughput processing and wide reproducibility owing to automation and standardization. As the LOC allows gamete handling within a microenvironment that strictly mimics physiological in vivo conditions and avoids centrifugation steps and long processing time, the use of microfluidics for sperm sorting and selection have been proposed during the last 15 years and is currently under investigation. Moreover, LOC technologies to sort, identify and analyse other kinds of cells could be transferred to sperm selection and analysis, thus opening the way to a novel approach to the sperm cell selection and manipulation. This review describes the techniques routinely performed in human and animal clinical practice for sorting good-quality sperm for in vitro fertilization procedures, and focuses on the positive and negative aspects of each method. Emerging microfluidic devices, recently proposed for sperm selection, are also described and, when possible, compared with standard methods.


Asunto(s)
Fertilización In Vitro , Espermatozoides , Animales , Humanos , Dispositivos Laboratorio en un Chip , Masculino , Microfluídica , Reproducibilidad de los Resultados
18.
J Colloid Interface Sci ; 552: 401-411, 2019 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-31146149

RESUMEN

Herein we present a straightforward approach for the use of polydopamine (PDA) in adsorption of heavy metals from aqueous solutions. This is achieved by fabricating a healthy and environmentally friendly polydimethylsiloxane (PDMS) foam with a mussel inspired PDA layer deposited on the surface. Critical adsorption parameters (pH, temperature and PDA thickness) are optimized by the application of experimental design methodology. Adsorption kinetics and isotherms are studied in detail evidencing a good fitting with Langmuir isotherm and pseudo-second-order kinetics thus suggesting the occurrence of a chemical sorption process with monolayer nature between metals and PDMS/PDA foam. Intraparticle diffusion model evidences good accessibility and high affinity of binding sites on PDA surface. Once adsorbed, metals are reduced to a lower toxic form and can be then removed by a mild acidic treatment thus being easily collected and stocked.

19.
Biosens Bioelectron ; 128: 122-128, 2019 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-30641454

RESUMEN

Type (II) diabetes is one of the major threats to mankind as it causes insulin resistance in human body and Retinol Binding Protein 4 (RBP4) is currently considered as a potential biomarker for early management of this disease. Hence a low-level detection of RBP4 is a very important task and for this purpose, a novel RBP4 biosensor has been developed using homemade plastic chip electrodes (PCEs) as a platform for self-assembled monolayer (SAM) of 4-ATP and further functionalization with glutaraldehyde. Anti RBP4 is used as biorecognition species and electrochemical impedance spectroscopy has been performed to detect different RBP4 concentrations plotted against charge transfer resistance. A wide concentration range from 100 fg/mL to 1 ng/mL has been tested and a low limit of detection (LOD) of 100 fg/mL has been achieved. This is the first report for fabrication of electrochemical biosensor of RBP4 using Ag-Ab interaction having such low LOD. The sensor is characterized by various physico-chemical techniques. Excellent reproducibility and quick measurement make this biosensor extremely useful for the biomedical industry.


Asunto(s)
Técnicas Biosensibles , Diabetes Mellitus Tipo 2/sangre , Proteínas Plasmáticas de Unión al Retinol/aislamiento & purificación , Glucemia , Diabetes Mellitus Tipo 2/genética , Diabetes Mellitus Tipo 2/patología , Electrodos , Glutaral/química , Humanos , Insulina/sangre , Resistencia a la Insulina/genética , Proteínas Plasmáticas de Unión al Retinol/genética
20.
Methods Mol Biol ; 1918: 87-101, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30580401

RESUMEN

In this chapter methods and protocols for surfaces adapted to electrochemical impedance detection, antibody binding, electrolyte couples used, and instrumentation for EIS Biosensing are presented. Various technical bottlenecks have been overcome in recent years. Other limitations still present in this technique are discussed. We present the most recent applications in food pathogen detection based on EIS methods, as well as using other antibody-based platforms.


Asunto(s)
Técnicas Biosensibles , Técnicas Electroquímicas , Contaminación de Alimentos , Microbiología de Alimentos/métodos , Enfermedades Transmitidas por los Alimentos/microbiología , Listeria monocytogenes , Técnicas Biosensibles/métodos , Humanos , Inmunoensayo , Listeria monocytogenes/fisiología , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...