Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Biosensors (Basel) ; 14(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38667160

RESUMEN

Galactose monitoring in individuals allows the prevention of harsh health conditions related to hereditary metabolic diseases like galactosemia. Current methods of galactose detection need development to obtain cheaper, more reliable, and more specific sensors. Enzyme-containing amperometric sensors based on galactose oxidase activity are a promising approach, which can be enhanced by means of their inclusion in a redox polymer coating. This strategy simultaneously allows the immobilization of the biocatalyst to the electroactive surface and hosts the electron shuttling units. An additional deposition of capping polymers prevents external interferences like ascorbic or uric acid as well as biofouling when measuring in physiological fuels. This work studies the protection effect of poly(2-methacryloyloxyethyl phosphorylcholine-co-glycidyl methacrylate (MPC) and polyvinylimidazole-polysulfostyrene (P(VI-SS)) when incorporated in the biosensor design for the detection of galactose in human plasma.


Asunto(s)
Técnicas Biosensibles , Galactosa , Polímeros , Humanos , Polímeros/química , Galactosa Oxidasa , Metacrilatos/química
2.
Biosensors (Basel) ; 13(10)2023 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-37887109

RESUMEN

The prevailing form of bacterial infection is within the urinary tract, encompassing a wide array of bacteria that harness the urinary metabolome for their growth. Through their metabolic actions, the chemical composition of the growth medium undergoes modifications as the bacteria metabolize urine compounds, leading to the subsequent release of metabolites. These changes can indirectly indicate the existence and proliferation of bacterial organisms. Here, we investigate the use of an electronic tongue, a powerful analytical instrument based on a combination of non-selective chemical sensors with a partial specificity for data gathering combined with principal component analysis, to distinguish between infected and non-infected artificial urine samples. Three prevalent bacteria found in urinary tract infections were investigated, Escherichia coli, Klebsiella pneumoniae, and Enterococcus faecalis. Furthermore, the electronic tongue analysis was supplemented with 1H NMR spectroscopy and flow cytometry. Bacteria-specific changes in compound consumption allowed for a qualitative differentiation between artificial urine medium and bacterial growth.


Asunto(s)
Bacterias , Nariz Electrónica , Espectroscopía de Protones por Resonancia Magnética , Citometría de Flujo/métodos , Espectroscopía de Resonancia Magnética/métodos , Escherichia coli , Medios de Cultivo
3.
Biosensors (Basel) ; 13(7)2023 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-37504115

RESUMEN

An electronic tongue is a powerful analytical instrument based on an array of non-selective chemical sensors with a partial specificity for data gathering and advanced pattern recognition methods for data analysis. Connecting electronic tongues with electrochemical techniques for data collection has led to various applications, mostly within sensing for food quality and environmental monitoring, but also in biomedical research for the analyses of different bioanalytes in human physiological fluids. In this paper, an electronic tongue consisting of six electrodes (viz., gold, platinum, palladium, titanium, iridium, and glassy carbon) was designed and tested in authentic (undiluted, unpretreated) human saliva samples from eight volunteers, collected before and during the COVID-19 pandemic. Investigations of 11 samples using differential pulse voltammetry and a principal component analysis allowed us to distinguish between SARS-CoV-2-free and infected authentic human saliva. This work, as a proof-of-principle demonstration, provides a new perspective for the use of electronic tongues in the field of enzyme-free electrochemical biosensing, highlighting their potential for future applications in non-invasive biomedical analyses.


Asunto(s)
Técnicas Biosensibles , COVID-19 , Humanos , SARS-CoV-2 , COVID-19/diagnóstico , Nariz Electrónica , Saliva , Estudios de Factibilidad , Pandemias , Técnicas Biosensibles/métodos
4.
Bioelectrochemistry ; 152: 108441, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37087795

RESUMEN

Managing blood glucose can affect important clinical outcomes during the intraoperative phase of surgery. However, currently available instruments for glucose monitoring during surgery are few and not optimized for the specific application. Here we report an attempt to exploit an enzymatic sensor in a vein replica that could continuously monitor glucose level in an authentic human bloodstream. First, detailed investigations of the superficial venous systems of volunteers were carried out using ocular and palpating examinations, as well as advanced ultrasound measurements. Second, a tubular glucose-sensitive biosensor mimicking a venous system was designed and tested. Almost ideal linear dependence of current output on glucose concentration in phosphate buffer saline was obtained in the range 2.2-22.0 mM, whereas the dependence in human plasma was less linear. Finally, the developed biosensor was investigated in whole blood under homeostatic conditions. A specific correlation was found between the current output and glucose concentration at the initial stage of the biodevice operation. However, with time, blood coagulation during measurements negatively affected the performance of the biodevice. When the experimental results were remodeled to predict the response without the influence of blood coagulation, the sensor output closely followed the blood glucose level.


Asunto(s)
Técnicas Biosensibles , Glucemia , Humanos , Automonitorización de la Glucosa Sanguínea , Glucosa , Técnicas Biosensibles/métodos
5.
Sensors (Basel) ; 23(1)2022 Dec 30.
Artículo en Inglés | MEDLINE | ID: mdl-36616986

RESUMEN

Bacterial infections can affect the skin, lungs, blood, and brain, and are among the leading causes of mortality globally. Early infection detection is critical in diagnosis and treatment but is a time- and work-consuming process taking several days, creating a hitherto unmet need to develop simple, rapid, and accurate methods for bacterial detection at the point of care. The most frequent type of bacterial infection is infection of the urinary tract. Here, we present a wireless-enabled, portable, potentiometric sensor for E. coli. E. coli was chosen as a model bacterium since it is the most common cause of urinary tract infections. The sensing principle is based on reduction of Prussian blue by the metabolic activity of the bacteria, detected by monitoring the potential of the sensor, transferring the sensor signal via Bluetooth, and recording the output on a laptop or a mobile phone. In sensing of bacteria in an artificial urine medium, E. coli was detected in ~4 h (237 ± 19 min; n = 4) and in less than 0.5 h (21 ± 7 min, n = 3) using initial E. coli concentrations of ~103 and 105 cells mL-1, respectively, which is under or on the limit for classification of a urinary tract infection. Detection of E. coli was also demonstrated in authentic urine samples with bacteria concentration as low as 104 cells mL-1, with a similar response recorded between urine samples collected from different volunteers as well as from morning and afternoon urine samples.


Asunto(s)
Escherichia coli , Infecciones Urinarias , Humanos , Infecciones Urinarias/diagnóstico , Infecciones Urinarias/microbiología , Infecciones Urinarias/orina , Bacterias
6.
Sensors (Basel) ; 20(21)2020 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-33171750

RESUMEN

Non-invasive healthcare technologies are an important part of research and development nowadays due to the low cost and convenience offered to both healthcare receivers and providers. This work overviews the recent advances in the field of non-invasive electrochemical biosensors operating in secreted human physiological fluids, viz. tears, sweat, saliva, and urine. Described electrochemical devices are based on different electrochemical techniques, viz. amperometry, coulometry, cyclic voltammetry, and impedance spectroscopy. Challenges that confront researchers in this exciting area and key requirements for biodevices are discussed. It is concluded that the field of non-invasive sensing of biomarkers in bodily fluid is highly convoluted. Nonetheless, if the drawbacks are appropriately addressed, and the pitfalls are adroitly circumvented, the approach will most certainly disrupt current clinical and self-monitoring practices.


Asunto(s)
Técnicas Biosensibles , Líquidos Corporales , Técnicas Electroquímicas , Humanos , Saliva , Sudor , Lágrimas , Orina
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...