Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Eur Spine J ; 33(1): 216-223, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37715791

RESUMEN

OBJECTIVES: To determine the predictive effect of Hounsfield unit (HU) values in the cervical vertebral body measured by computed tomography (CT) and T-scores measured by dual-energy X-ray absorptiometry (DXA) on Zero-P subsidence after anterior cervical discectomy and fusion (ACDF)with Zero-P. In addition, we evaluated the most reliable measurement of cervical HU values. METHODS: We reviewed 76 patients who underwent single-level Zero-P fusion for cervical spondylosis. HU values were measured on CT images according to previous studies. Univariate analysis was used to screen the influencing factors of Zero-P subsidence, and then, logistic regression was used to determine the independent risk factors. The area under the receiver operating characteristic curve (AUC) was used to evaluate the ability to predict Zero-P subsidence. RESULTS: Twelve patients (15.8%) developed Zero-P subsidence. There were significant differences between subsidence group and non-subsidence group in terms of age, axial HU value, and HU value of midsagittal, midcoronal, and midaxial (MSCD), but there were no significant differences in lowest T-score and lowest BMD. The axial HU value (OR = 0.925) and HU value of MSCD (OR = 0.892) were independent risk factors for Zero-P subsidence, and the lowest T-score was not (OR = 1.186). The AUC of predicting Zero-P subsidence was 0.798 for axial HU value, 0.861 for HU value of MSCD, and 0.656 for T-score. CONCLUSIONS: Lower cervical HU value indicates a higher risk of subsidence in patients following Zero-P fusion for single-level cervical spondylosis. HU values were better predictors of Zero-P subsidence than DXA T-scores. In addition, the measurement of HU value in the midsagittal, midcoronal, and midaxial planes of the cervical vertebral body provides an effective method for predicting Zero-P subsidence.


Asunto(s)
Fusión Vertebral , Espondilosis , Humanos , Absorciometría de Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Discectomía , Curva ROC , Espondilosis/diagnóstico por imagen , Espondilosis/cirugía , Estudios Retrospectivos , Fusión Vertebral/métodos , Vértebras Lumbares
2.
Chin J Integr Med ; 29(7): 665-672, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37074617

RESUMEN

With the proliferation of synthetic drugs, research on the mechanism of action of addictive drugs and treatment methods is of great significance. Among them, methamphetamine (METH) is the most representative amphetamine synthetic drug, and the treatment of METH addiction has become an urgent medical and social problem. In recent years, the therapeutic effects of Chinese herbal medicines on METH addiction have gained widespread attention because of their non-addictiveness, multiple targets, low side effects, low cost, and other characteristics. Previous studies have identified a variety of Chinese herbal medicines with effects on METH addiction. Based on the research on METH in recent years, this article summarizes the mechanism of action of METH as the starting point and briefly reviews the Chinese herbal medicine-based treatment of METH.


Asunto(s)
Trastornos Relacionados con Anfetaminas , Conducta Adictiva , Medicamentos Herbarios Chinos , Metanfetamina , Humanos , Metanfetamina/efectos adversos , Medicamentos Herbarios Chinos/farmacología , Medicamentos Herbarios Chinos/uso terapéutico , Anfetamina/uso terapéutico , Conducta Adictiva/tratamiento farmacológico , Trastornos Relacionados con Anfetaminas/tratamiento farmacológico
4.
Z Orthop Unfall ; 2023 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-36720241

RESUMEN

BACKGROUND: Our aim was to determine if the dual-energy X-ray absorptiometry (DXA)-measured forearm bone mineral density (BMD) correlates with the Hounsfield unit (HU) values obtained from computed tomography (CT). METHODS: A retrospective analysis of 164 patients with degenerative diseases of the lumbar spine was performed. DXA was used to measure the BMD and T-scores of each patient's forearm. Lumbar CT was used to measure the CT HU values in three axial images of the L1-L4 vertebral bodies, and the average was calculated. According to the preoperative DXA T-score, they were divided into a normal group, an osteopenia group, and an osteoporosis group. Pearson's correlation coefficient was used to analyze the correlations of CT HU values in L1-L4 with BMD and T-scores in the corresponding vertebral body. The receiver operating characteristic curve (ROC) was used to determine the CT HU thresholds between osteoporosis and non-osteoporosis groups. RESULTS: Forearm BMD was moderately correlated with L1-L4 CT HU values (0.4 < R2 < 0.6), and the correlation coefficients (R2) were 0.552, 0.578, 0.582, and 0.577, respectively (all p < 0.001). Forearm T-scores were moderately correlated with L1-L4 CT HU values (0.4 < R2 < 0.6), and the correlation coefficients (R2) were 0.595, 0.609, 0.605, and 0.605, respectively (all p < 0.001). The thresholds of L1-L4 between the osteoporosis group (t ≤ -2.5) and the non-osteoporosis group (t > -2.5) were 110.0 HU (sensitivity 74% and specificity 76%), 112.5 HU (sensitivity 67% and 83% specificity), 92.4 HU (81% sensitivity and 70% specificity), and 98.7 HU (74% sensitivity and 78% specificity), respectively. CONCLUSIONS: Based on the moderate positive correlation between forearm DXA-measured BMD and HU values, forearm DXA provides a theoretical basis for evaluating lumbar vertebral bone mass. Preoperative forearm DXA may be useful in the formulation of surgical plans and the prevention of postoperative complications in patients with lumbar degenerative diseases.

5.
BMC Musculoskelet Disord ; 23(1): 1058, 2022 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-36471300

RESUMEN

BACKGROUND: Posterior lumbar interbody fusion (PLIF) has become a classic treatment modality for lumbar degenerative diseases, with cage subsidence as a potentially fatal complication due to low bone mineral density (BMD), which can be measured by forearm T-score. Hounsfield units (HU) derived from computed tomography have been a reliable method for assessing BMD. OBJECTIVE: To determine the accuracy of forearm T-score in predicting cage subsidence after PLIF compared with lumbar spine HU values. METHODS: We retrospectively analyzed the clinical data of 71 patients who underwent PLIF and divided them into cage subsidence group and nonsubsidence group. The differences in preoperative HU value and forearm T-score were compared between groups, and the correlation between cage subsidence and clinical efficacy was analyzed. RESULTS: The subsidence rate for all 71 patients (31 men and 40 women) was 23.9%. There was no significant difference in age, sex ratio, body mass index, smoking status, follow-up time, spine BMD, and spine T-score between groups, except in the forearm T-score and lumbar spine HU values (P < 0.05). The forearm T-score (AUC, 0.840; 95% CI, 0.672-1.000) predicted cage subsidence more accurately than the mean global HU value (AUC, 0.744; 95% CI, 0.544-0.943). In logistic regression analysis, both forearm T-score and mean global HU value were found to be independent risk factors for cage subsidence (P < 0.05). CONCLUSIONS: Lower forearm T-scores and lower lumbar spine HU values were significantly associated with the occurrence of cage subsidence. Lower forearm T-scores indicated a higher risk of cage subsidence than lumbar spine HU values. Forearm T-score is more effective in predicting cage subsidence than spine T-score. Therefore, forearm dual-energy X-ray absorptiometry may be a fast, simple, and reliable method for predicting cage subsidence following PLIF. However, our results suggest that the degree of cage subsidence is not associated with clinical efficacy.


Asunto(s)
Fusión Vertebral , Masculino , Humanos , Femenino , Fusión Vertebral/efectos adversos , Fusión Vertebral/métodos , Estudios Retrospectivos , Antebrazo , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Región Lumbosacra
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...