Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Am Coll Cardiol ; 82(7): 590-599, 2023 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-37558371

RESUMEN

BACKGROUND: Very few data have been published on the use of subcutaneous implantable cardioverter-defibrillators (S-ICDs) in patients with congenital heart disease (CHD). OBJECTIVES: The aim of this study was to analyze outcomes associated with S-ICDs in patients with CHD. METHODS: This nationwide French cohort including all patients with an S-ICD was initiated in 2020 by the French Institute of Health and Medical Research. Characteristics at implantation and outcomes were analyzed in patients with CHD. RESULTS: From October 12, 2012, to December 31, 2019, among 4,924 patients receiving an S-ICD implant in 150 centers, 101 (2.1%) had CHD. Tetralogy of Fallot, univentricular heart, and dextro-transposition of the great arteries represented almost one-half of the population. Patients with CHD were significantly younger (age 37.1 ± 15.4 years vs 50.1 ± 14.9 years; P < 0.001), more frequently female (37.6% vs 23.0%; P < 0.001), more likely to receive an S-ICD for secondary prevention (72.3% vs 35.9%; P < 0.001), and less likely to have severe systolic dysfunction of the systemic ventricle (28.1% vs 53.1%; P < 0.001). Over a mean follow-up period of 1.9 years, 16 (15.8%) patients with CHD received at least 1 appropriate shock, with all shocks successfully terminating the ventricular arrhythmia. The crude risk of appropriate S-ICD shock was twice as high in patients with CHD compared with non-CHD patients (annual incidences of 9.0% vs 4.4%; HR: 2.1; 95% CI: 1.3-3.4); however, this association was no longer significant after propensity matching (especially considering S-ICD indication, P = 0.12). The burden of all complications (HR: 1.2; 95% CI: 0.7-2.1; P = 0.4) and inappropriate shocks (HR: 0.9; 95% CI: 0.4-2.0; P = 0.9) was comparable in both groups. CONCLUSIONS: In this nationwide study, patients with CHD represented 2% of all S-ICD implantations. Our findings emphasize the effectiveness and safety of S-ICD in this particularly high-risk population. (S-ICD French Cohort Study [HONEST]; NCT05302115).


Asunto(s)
Desfibriladores Implantables , Cardiopatías Congénitas , Transposición de los Grandes Vasos , Humanos , Femenino , Adulto Joven , Adulto , Persona de Mediana Edad , Desfibriladores Implantables/efectos adversos , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/etiología , Estudios de Cohortes , Resultado del Tratamiento , Estudios Retrospectivos , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/terapia
2.
Heart Rhythm ; 20(2): 252-260, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36309156

RESUMEN

BACKGROUND: In repaired tetralogy of Fallot (TOF), little is known about characteristics of patients with rapid ventricular tachycardia (VT). Also, whether patients with a first episode of nonrapid VT may subsequently develop rapid VT or ventricular fibrillation (VF) has not been addressed. OBJECTIVES: The objectives of this study were to compare patients with rapid VT/VF with those with nonrapid VT and to assess the evolution of VT cycle lengths (VTCLs) overtime. METHODS: Data were analyzed from a nationwide registry including all patients with TOF and implantable cardioverter-defibrillator (ICD) since 2000. Patients with ≥1 VT episode with VTCL ≤250 ms (240 beats/min) formed the rapid VT/VF group. RESULTS: Of 144 patients (mean age 42.0 ± 12.7 years; 104 [72%] men), 61 (42%) had at least 1 VT/VF episode, including 28 patients with rapid VT/VF (46%), during a median follow-up of 6.3 years (interquartile range 2.2-10.3 years). Compared with patients in the nonrapid VT group, those in the rapid VT/VF group were significantly younger at ICD implantation (35.2 ± 12.6 years vs 41.5 ± 11.2 years; P = .04), had more frequently a history of cardiac arrest (8 [29%] vs 2 [6%]; P = .02), less frequently a history of atrial arrhythmia (11 [42%] vs 22 [69%]; P = .004), and higher right ventricular ejection fraction (43.3% ± 10.3% vs 36.6% ± 11.2%; P = .04). The median VTCL of VT/VF episodes was 325 ms (interquartile range 235-429 ms). None of the patients with a first documented nonrapid VT episode had rapid VT/VF during follow-up. CONCLUSION: Patients with TOF and rapid VT/VF had distinct clinical characteristics. The relatively low variation of VTCL over time suggests a room for catheter ablation without a backup ICD in selected patients with well-tolerated VT.


Asunto(s)
Desfibriladores Implantables , Taquicardia Ventricular , Tetralogía de Fallot , Masculino , Humanos , Adulto , Persona de Mediana Edad , Femenino , Volumen Sistólico , Tetralogía de Fallot/complicaciones , Tetralogía de Fallot/cirugía , Estudios de Seguimiento , Función Ventricular Derecha , Taquicardia Ventricular/epidemiología , Taquicardia Ventricular/etiología , Taquicardia Ventricular/terapia , Fibrilación Ventricular
3.
JACC Clin Electrophysiol ; 8(10): 1304-1314, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36266008

RESUMEN

BACKGROUND: Women with congenital heart disease at high risk for sudden cardiac death have been poorly studied thus far. OBJECTIVES: The aim of this study was to assess sex-related differences in patients with tetralogy of Fallot (TOF) and implantable cardioverter-defibrillators (ICDs). METHODS: Data were analyzed from the DAI-T4F (French National Registry of Patients With Tetralogy of Fallot and Implantable Cardioverter Defibrillator) cohort study, which has prospectively enrolled all patients with TOF with ICDs in France since 2010. Clinical events were centrally adjudicated by a blinded committee. RESULTS: A total of 165 patients (mean age 42.2 ± 13.3 years) were enrolled from 40 centers, including 49 women (29.7%). Among the 9,692 patients with TOF recorded in the national database, the proportion of women with ICDs was estimated to be 1.1% (95% CI: 0.8%-1.5%) vs 2.2% (95% CI: 1.8%-2.6%) in men (P < 0.001). The clinical profiles of patients at implantation, including the number of risk factors for ventricular arrhythmias, were similar between women and men. During a median follow-up period of 6.8 years (IQR: 2.5-11.4 years), 78 patients (47.3%) received at least 1 appropriate ICD therapy, without significant difference in annual incidences between women (12.1%) and men (9.9%) (HR: 1.22; 95% CI: 0.76-1.97; P = 0.40). The risk for overall ICD-related complications was similar in women and men (HR: 1.33; 95% CI: 0.81-2.19; P = 0.30), with 24 women (49.0%) experiencing at least 1 complication. CONCLUSIONS: Our findings suggest that women with TOF at high risk for sudden cardiac death have similar benefit/risk balance from ICD therapy compared with men. Whether ICD therapy is equally offered to at-risk women vs men warrants further evaluation in TOF as well as in other congenital heart disease populations. (French National Registry of Patients With Tetralogy of Fallot and Implantable Cardioverter Defibrillator [DAI-T4F]; NCT03837574).


Asunto(s)
Desfibriladores Implantables , Cardiopatías Congénitas , Tetralogía de Fallot , Humanos , Femenino , Masculino , Adulto , Persona de Mediana Edad , Desfibriladores Implantables/efectos adversos , Tetralogía de Fallot/complicaciones , Estudios de Cohortes , Caracteres Sexuales , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/etiología , Cardiopatías Congénitas/complicaciones
4.
Circulation ; 142(17): 1612-1622, 2020 10 27.
Artículo en Inglés | MEDLINE | ID: mdl-32998542

RESUMEN

BACKGROUND: Tetralogy of Fallot (TOF) is the most common cyanotic congenital heart disease, and sudden cardiac death represents an important mode of death in these patients. Data evaluating the implantable cardioverter defibrillator (ICD) in this patient population remain scarce. METHODS: A Nationwide French Registry including all patients with tetralogy of Fallot with an ICD was initiated in 2010 by the French Institute of Health and Medical Research. The primary time to event end point was the time from ICD implantation to first appropriate ICD therapy. Secondary outcomes included ICD-related complications, heart transplantation, and death. Clinical events were centrally adjudicated by a blinded committee. RESULTS: A total of 165 patients (mean age, 42.2±13.3 years, 70.1% males) were included from 40 centers, including 104 (63.0%) in secondary prevention. During a median (interquartile range) follow-up of 6.8 (2.5-11.4) years, 78 (47.3%) patients received at least 1 appropriate ICD therapy. The annual incidence of the primary outcome was 10.5% (7.1% and 12.5% in primary and secondary prevention, respectively; P=0.03). Overall, 71 (43.0%) patients presented with at least 1 ICD complication, including inappropriate shocks in 42 (25.5%) patients and lead dysfunction in 36 (21.8%) patients. Among 61 (37.0%) patients in primary prevention, the annual rate of appropriate ICD therapies was 4.1%, 5.3%, 9.5%, and 13.3% in patients with, respectively, 0, 1, 2, or ≥3 guidelines-recommended risk factors. QRS fragmentation was the only independent predictor of appropriate ICD therapies (hazard ratio, 3.47 [95% CI, 1.19-10.11]), and its integration in a model with current criteria increased the 5-year time-dependent area under the curve from 0.68 to 0.81 (P=0.006). Patients with congestive heart failure or reduced left ventricular ejection fraction had a higher risk of nonarrhythmic death or heart transplantation (hazard ratio, 11.01 [95% CI, 2.96-40.95]). CONCLUSIONS: Patients with tetralogy of Fallot and an ICD experience high rates of appropriate therapies, including those implanted in primary prevention. The considerable long-term burden of ICD-related complications, however, underlines the need for careful candidate selection. A combination of easy-to-use criteria including QRS fragmentation might improve risk stratification. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03837574.


Asunto(s)
Desfibriladores Implantables/tendencias , Tetralogía de Fallot/epidemiología , Tetralogía de Fallot/terapia , Adulto , Femenino , Estudios de Seguimiento , Humanos , Masculino , Sistema de Registros
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...