Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
2.
J Cardiovasc Med (Hagerstown) ; 25(7): 473-487, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38829936

RESUMEN

Cardiovascular magnetic resonance (CMR) and computed tomography (CCT) are advanced imaging modalities that recently revolutionized the conventional diagnostic approach to congenital heart diseases (CHD), supporting echocardiography and often replacing cardiac catheterization. This is the second of two complementary documents, endorsed by experts from the Working Group of the Italian Society of Pediatric Cardiology and the Italian College of Cardiac Radiology of the Italian Society of Medical and Interventional Radiology, aimed at giving updated indications on the appropriate use of CMR and CCT in different clinical CHD settings, in both pediatrics and adults. In this article, support is also given to radiologists, pediatricians, cardiologists, and cardiac surgeons for indications and appropriateness criteria for CMR and CCT in the most referred CHD, following the proposed new criteria presented and discussed in the first document. This second document also examines the impact of devices and prostheses for CMR and CCT in CHD and additionally presents some indications for CMR and CCT exams when sedation or narcosis is needed.


Asunto(s)
Consenso , Cardiopatías Congénitas , Humanos , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/terapia , Italia , Tomografía Computarizada por Rayos X/normas , Cardiología/normas , Imagen por Resonancia Magnética/normas , Niño , Valor Predictivo de las Pruebas , Adulto , Sociedades Médicas/normas
3.
J Cardiovasc Surg (Torino) ; 65(1): 49-63, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38037721

RESUMEN

The objective of these Guidelines is to provide recommendations for the classification, indication, treatment and management of patients suffering from aneurysmal pathology of the visceral and renal arteries. The methodology applied was the GRADE-SIGN version, and followed the instructions of the AGREE quality of reporting checklist. Clinical questions, structured according to the PICO (Population, Intervention, Comparator, Outcome) model, were formulated, and systematic literature reviews were carried out according to them. Selected articles were evaluated through specific methodological checklists. Considered Judgments were compiled for each clinical question in which the characteristics of the body of available evidence were evaluated in order to establish recommendations. Overall, 79 clinical practice recommendations were proposed. Indications for treatment and therapeutic options were discussed for each arterial district, as well as follow-up and medical management, in both candidate patients for conservative therapy and patients who underwent treatment. The recommendations provided by these guidelines simplify and improve decision-making processes and diagnostic-therapeutic pathways of patients with visceral and renal arteries aneurysms. Their widespread use is recommended.


Asunto(s)
Aneurisma , Embolización Terapéutica , Humanos , Arteria Renal/diagnóstico por imagen , Radiología Intervencionista , Aneurisma/diagnóstico por imagen , Aneurisma/cirugía , Embolización Terapéutica/efectos adversos , Italia
4.
Diagnostics (Basel) ; 13(20)2023 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-37892076

RESUMEN

Background: Managing repaired tetralogy of Fallot (TOF) patients is still challenging despite the fact that published studies identified prognostic clinical or imaging data with rather good negative predictive accuracy but weak positive predictive accuracy. Heterogeneity of the initial anatomy, the surgical approach, and the complexity of the mechanism leading to dilation and ventricular dysfunction explain the challenge of predicting the adverse event in this population. Therefore, risk stratification and management of this population remain poorly standardized. Design: The CMR/CT WG of the Italian Pediatric Cardiology Society set up a multicenter observational clinical database of repaired TOF evaluations. This registry will enroll patients retrospectively and prospectively assessed by CMR for clinical indication in many congenital heart diseases (CHD) Italian centers. Data collection in a dedicated platform will include surgical history, clinical data, imaging data, and adverse cardiac events at 6 years of follow-up. Summary: The multicenter repaired TOF clinical database will collect data on patients evaluated by CMR in many CHD centers in Italy. The registry has been set up to allow future research studies in this population to improve clinical/surgical management and risk stratification of this population.

5.
Biomech Model Mechanobiol ; 22(6): 1829-1846, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37400622

RESUMEN

In this work, we performed a computational image-based study of blood dynamics in the whole left heart, both in a healthy subject and in a patient with mitral valve regurgitation. We elaborated multi-series cine-MRI with the aim of reconstructing the geometry and the corresponding motion of left ventricle, left atrium, mitral and aortic valves, and aortic root of the subjects. This allowed us to prescribe such motion to computational blood dynamics simulations where, for the first time, the whole left heart motion of the subject is considered, allowing us to obtain reliable subject-specific information. The final aim is to investigate and compare between the subjects the occurrence of turbulence and the risk of hemolysis and of thrombi formation. In particular, we modeled blood with the Navier-Stokes equations in the arbitrary Lagrangian-Eulerian framework, with a large eddy simulation model to describe the transition to turbulence and a resistive method to manage the valve dynamics, and we used a finite element discretization implemented in an in-house code for the numerical solution.


Asunto(s)
Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Ventrículos Cardíacos , Válvula Aórtica/diagnóstico por imagen , Simulación por Computador , Imagen por Resonancia Magnética , Modelos Cardiovasculares
6.
Cardiovasc Eng Technol ; 14(3): 457-475, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37069336

RESUMEN

PURPOSE: In this work we performed an imaged-based computational study of the systolic fluid dynamics in presence of mitral valve regurgitation (MVR). In particular, we compared healthy and different regurgitant scenarios with the aim of quantifying different hemodynamic quantities. METHODS: We performed computational fluid dynamic (CFD) simulations in the left ventricle, left atrium and aortic root, with a resistive immersed method, a turbulence model, and with imposed systolic wall motion reconstructed from Cine-MRI images, which allowed us to segment also the mitral valve. For the regurgitant scenarios we considered an increase of the heart rate and a dilation of the left ventricle. RESULTS: Our results highlighted that MVR gave rise to regurgitant jets through the mitral orifice impinging against the atrial walls and scratching against the mitral valve leading to high values of wall shear stresses (WSSs) with respect to the healthy case. CONCLUSION: CFD with prescribed wall motion and immersed mitral valve revealed to be an effective tool to quantitatively describe hemodynamics in case of MVR and to compare different regurgitant scenarios. Our findings highlighted in particular the presence of transition to turbulence in the atrium and allowed us to quantify some important cardiac indices such as cardiac output and WSS.


Asunto(s)
Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Hidrodinámica , Válvula Mitral/diagnóstico por imagen , Hemodinámica , Prolapso
7.
Radiol Med ; 127(7): 788-802, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35608758

RESUMEN

Cardiovascular magnetic resonance (CMR) and computed tomography (CCT) are advanced imaging modalities that recently revolutionized the conventional diagnostic approach to congenital heart diseases (CHD), supporting echocardiography and often replacing cardiac catheterization. Nevertheless, correct execution and interpretation require in-depth knowledge of all technical and clinical aspects of CHD, a careful assessment of risks and benefits before each exam, proper imaging protocols to maximize diagnostic information, minimizing harm. This position paper, written by experts from the Working Group of the Italian Society of Pediatric Cardiology and from the Italian College of Cardiac Radiology of the Italian Society of Medical and Interventional Radiology, is intended as a practical guide for applying CCT and CMR in children and adults with CHD, wishing to support Radiologists, Pediatricians, Cardiologists and Cardiac Surgeons in the multimodality diagnostic approach to these patients. The first part provides a review of the most relevant literature in the field, describes each modality's advantage and drawback, making considerations on the main applications, image quality, and safety issues. The second part focuses on clinical indications and appropriateness criteria for CMR and CCT, considering the level of CHD complexity, the clinical and logistic setting and the operator expertise.


Asunto(s)
Cardiología , Cardiopatías Congénitas , Adulto , Niño , Consenso , Cardiopatías Congénitas/diagnóstico por imagen , Humanos , Espectroscopía de Resonancia Magnética , Radiología Intervencionista , Tomografía Computarizada por Rayos X
8.
Transl Cancer Res ; 11(12): 4338-4348, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36644169

RESUMEN

Background: Pneumothorax (PNX), pulmonary hemorrhage, hemothorax and chest wall hematoma are the most commonly reported complications of percutaneous lung biopsy (PLB). Sealing the biopsy tract with different types of materials is an emerging way to prevent PLB complications. Methods: To investigate the safety and efficacy of a new device, Minimally Invasive Percutaneous Procedure Kit for Pneumothorax (MIPP-Kit PNX), when used in association with a resorbable bio-compatible glue in the prevention of PLB complications. A prospective, multicenter, open-label, single-arm study was performed to evaluate the complication rate after glue administration by the new investigational device during PLBs. Results: Fourty-three patients were enrolled after informed consent signature (40 underwent PLB, while three were screening failures). Only 3 patients (7.5%, 95% CI: 0.0-15.7%) developed complications within 48 h after glue injection during PLB: two developed minor pneumothoraces and one a pulmonary hemorrhage. No patients who showed procedural complications before glue administration were reported with any recurrent or new complications after glue administration. Conclusions: In comparison with the data reported in the literature, this trial results support the safe and effective use of the MIPP kit PNX in the prevention of PLB complications. These promising preliminary results warrant further confirmation in larger clinical trials. Trial Registration: ClinicalTrials.gov identifier: NCT04071509.

9.
Hepatol Int ; 14(5): 850-857, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32557193

RESUMEN

BACKGROUND: Non-selective ß-blocker (NSBB) therapy is the treatment of choice for primary prophylaxis of cirrhotic patients with high-bleeding risk esophageal varices (HRV). The hemodynamic response to NSBB is assessed by the measurement of the hepatic venous pressure gradient (HVPG). Recently, liver and spleen stiffness measurements (LSM and SSM) were proposed as non-invasive surrogates of HVPG. We aimed to evaluate LSM and SSM changes for assessing hemodynamic response in these patients. METHODS: Cirrhotic patients with HRV were prospectively enrolled and evaluated at our Department before starting NSBB and after 3 months. Correlation between changes (delta) of HVPG after NSBB treatment and those of LSM or SSM by transient elastography was performed. RESULTS: From the initial 59 patients considered for the study, 20 were finally included in the analysis. Fifteen (15) patients reached hemodynamic response to NSBB according to HVPG. Changes in LSM did not correlate with changes in HVPG (r = 0.107, p value = 0.655), unlike changes in SSM (r = 0.784, p value < 0.0001). Delta SSM presented excellent accuracy in identifying HVPG responders (AUROC 0.973; 95% CI 0.912-1). The best cut-off for delta SSM to identify responders was -10% (sensitivity 100%, specificity 60%, NPV 100% and PPV 90%). CONCLUSIONS: SSM could be a reliable non-invasive test for the assessment of hemodynamic response to NSBB therapy as primary prophylaxis for HRV. Similar to HVPG, SSM reduction ≥ 10% is able to assess hemodynamic response.


Asunto(s)
Antagonistas Adrenérgicos beta , Diagnóstico por Imagen de Elasticidad/métodos , Várices Esofágicas y Gástricas , Hemorragia , Hígado , Bazo , Antagonistas Adrenérgicos beta/administración & dosificación , Antagonistas Adrenérgicos beta/efectos adversos , Diagnóstico por Imagen de Elasticidad/estadística & datos numéricos , Várices Esofágicas y Gástricas/complicaciones , Várices Esofágicas y Gástricas/diagnóstico , Várices Esofágicas y Gástricas/tratamiento farmacológico , Femenino , Hemorragia/diagnóstico , Hemorragia/etiología , Hemorragia/prevención & control , Humanos , Hígado/irrigación sanguínea , Hígado/diagnóstico por imagen , Hígado/patología , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Ajuste de Riesgo/métodos , Bazo/irrigación sanguínea , Bazo/diagnóstico por imagen , Bazo/patología
10.
Cureus ; 12(4): e7629, 2020 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-32399361

RESUMEN

A patient with end-stage liver disease and subsequent refractory ascites was treated with a transjugular intrahepatic portosystemic shunt (TIPS) procedure. The procedure was complicated by massive gastrointestinal hemorrhage with associated rettorragia. Computed tomography angiography (CT-A) was performed and revealed haemobilia due to an artero-biliary fistula between the right hepatic artery and an intrahepatic biliary branch. The patient underwent an attempt at percutaneous embolization. Bleeding was successfully stopped by the embolization of the fistula with coils. Hemobilia is a rare cause of upper gastrointestinal bleeding with an increasing incidence due to the widespread use of invasive hepatobiliary procedures. Hemobilia is an uncommon complication of TIPS procedures. Nowadays, transcatheter embolization is the gold standard in the management of hemobilia.

11.
Aorta (Stamford) ; 7(4): 121-124, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31770774

RESUMEN

In selected cases, the utilization of branched endografts for the treatment of aortic arch aneurysms could be a safe and advantageous alternative to high-risk procedures such as open total aortic arch replacement or hybrid arch repair. We present the case of a 70-year-old man with saccular aneurysm of a bovine aortic arch which was endovascularly treated using a double-branched custom-made aortic endoprosthesis based on the Relay NBS (Non-Bare Stent) Plus platform intended for zone 0 deployment. The postoperative clinical course was uneventful. The postoperative computed tomography scan showed a good result of the implant. The patient was discharged 6 days after the procedure.

12.
Pol J Radiol ; 83: e519-e523, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30800190

RESUMEN

PURPOSE: The purpose of the present study is to systematically assess the prevalence and characteristics of the corona mortis (CM) variant of the obturator artery by means of computerised tomography angiography (CTA). MATERIAL AND METHODS: A total of 150 consecutive patients (112 males, average age 73 years) referred to CTA for lower limb arterial evaluation were included in this retrospective study. Patient demographics, anastomosis incidence, artery diameter, distance from the symphysis pubis, Kellgren-Lawrence score, and pelvic size were evaluated. RESULTS: In this study 40.6% of patients presented at least one competent CM arterial anastomosis. In the 300 evaluated arteries, 90 arterial anastomoses were found (30%), 40 on the right side (average diameter 1.63 mm) and 50 on the left side (1.78 mm). In 32 cases there was only one anastomosis, while in 29 cases the CM was bilateral. No anastomoses were detected in 89 patients. Mean distance from the symphysis was 50 mm. No relevant association with hip osteoarthrosis was found for CM. Mean pelvic size was 213 mm. CONCLUSIONS: The evidence from this study suggests that CM is a common variant that needs to be acknowledged before pelvic intervention.

13.
J Thorac Dis ; 9(Suppl 4): S225-S238, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28540065

RESUMEN

BACKGROUND: Accurate quantification of mitral valve (MV) morphology and dynamic behavior over the cardiac cycle is crucial to understand the mechanisms of degenerative MV dysfunction and to guide the surgical intervention. Cardiac magnetic resonance (CMR) imaging has progressively been adopted to evaluate MV pathophysiology, although a dedicated framework is required to perform a quantitative assessment of the functional MV anatomy. METHODS: We investigated MV dynamic behavior in subjects with normal MV anatomy (n=10) and patients referred to surgery due to degenerative MV prolapse, classified as fibro-elastic deficiency (FED, n=9) and Barlow's disease (BD, n=10). A CMR-dedicated framework was adopted to evaluate prolapse height and volume and quantitatively assess valvular morphology and papillary muscles (PAPs) function over the cardiac cycle. Multiple comparison was used to investigate the hallmarks associated to MV degenerative prolapse and evaluate the feasibility of anatomical and functional distinction between FED and BD phenotypes. RESULTS: On average, annular dimensions were significantly (P<0.05) larger in BD than in FED and normal subjects while no significant differences were noticed between FED and normal. MV eccentricity progressively decreased passing from normal to FED and BD, with the latter exhibiting a rounder annulus shape. Over the cardiac cycle, we noticed significant differences for BD during systole with an abnormal annular enlargement between mid and late systole (LS) (P<0.001 vs. normal); the PAPs dynamics remained comparable in the three groups. Prolapse height and volume highlighted significant differences among normal, FED and BD valves. CONCLUSIONS: Our CMR-dedicated framework allows for the quantitative and dynamic evaluation of MV apparatus, with quantifiable annular alterations representing the primary hallmark of severe MV degeneration. This may aid surgeons in the evaluation of the severity of MV dysfunction and the selection of the appropriate MV treatment.

14.
Pol J Radiol ; 82: 244-247, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28533827

RESUMEN

BACKGROUND: Anastomotic pseudoaneurysm is an underestimated complication of aorto-iliac grafts. CASE REPORT: This case report describes an unusual presentation of a pseudoaneurysm with a particularly complex anatomy involving both the left iliac branches, which hindered the interpretation of diagnostic studies and therapeutic management in a patient with multiple comorbidities. CONCLUSIONS: The manuscript describes a successful management of such a complication by means of an elective endovascular approach.

15.
Pol J Radiol ; 81: 532-535, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27882189

RESUMEN

BACKGROUND: Renal artery stenosis is a common cause of secondary hypertension refractory to medical therapy. Percutaneous angioplasty along with metallic stent placement has been described as an effective treatment for revascularization of the renal artery. CASE REPORT: A 54-year-old woman affected by paranoid schizophrenia with a history of hypertension and chronic renal failure due to renal artery occlusion was treated by endovascular recanalization and stent placement that resulted in improvement of renal function and control of hypertension. Laboratory studies 4 months after the revascularization revealed blood creatinine decrease gradually from 8.57 mg/dL to 3 mg/dL. CONCLUSIONS: Revascularization with stenting has proven to be a safe and effective procedure in the treatment of total renal artery occlusion which also led to a significant relief at a psychological level.

16.
J Cardiovasc Med (Hagerstown) ; 17 Suppl 2: e225-e227, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24979119

RESUMEN

: We report the case of a 56-year-old male patient affected by a severe form of Ebstein's anomaly (type C of Carpentier classification) with secundum atrial septal defect, who presented to the emergency department with impaired consciousness, seizures, and trismus. The brain computed tomography scan showed evidence of a mass located in the frontal lobe, confirmed by brain MRI consistent with brain abscess. Both echocardiography and cardiac MRI showed no evidence of valvular vegetation. This case shows how the combination of increased atrial pressure and bidirectional shunt through atrial septal defect may lead to paradoxical embolization.


Asunto(s)
Anomalías Múltiples , Absceso Encefálico/microbiología , Anomalía de Ebstein/complicaciones , Embolia Paradójica/microbiología , Defectos del Tabique Interatrial/complicaciones , Embolia Intracraneal/microbiología , Antibacterianos/uso terapéutico , Presión Atrial , Absceso Encefálico/diagnóstico por imagen , Absceso Encefálico/tratamiento farmacológico , Circulación Coronaria , Anomalía de Ebstein/diagnóstico por imagen , Anomalía de Ebstein/fisiopatología , Ecocardiografía Doppler en Color , Embolia Paradójica/diagnóstico por imagen , Defectos del Tabique Interatrial/diagnóstico por imagen , Defectos del Tabique Interatrial/fisiopatología , Hemodinámica , Humanos , Embolia Intracraneal/diagnóstico por imagen , Imagen por Resonancia Cinemagnética , Masculino , Persona de Mediana Edad , Factores de Riesgo , Convulsiones/microbiología , Índice de Severidad de la Enfermedad , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/complicaciones , Insuficiencia de la Válvula Tricúspide/fisiopatología , Trismo/microbiología
17.
Cardiovasc Eng Technol ; 6(2): 117-40, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26577231

RESUMEN

Mitral regurgitation is the most prevalent heart valve disease in the western population. When severe, it requires surgical treatment, repair being the preferred option. The edge-to-edge repair technique treats mitral regurgitation by suturing the leaflets together and creating a double-orifice valve. Due to its relative simplicity and versatility, it has become progressively more widespread. Recently, its percutaneous version has become feasible, and has raised interest thanks to the positive results of the Mitraclip(®) device. Edge-to-edge features and evolution have stimulated debate and multidisciplinary research by both clinicians and engineers. After providing an overview of representative studies in the field, here we propose a novel computational approach to the most recent percutaneous evolution of the edge-to-edge technique. Image-based structural finite element models of three mitral valves affected by posterior prolapse were derived from cine-cardiac magnetic resonance imaging. The models accounted for the patient-specific 3D geometry of the valve, including leaflet compound curvature pattern, patient-specific motion of annulus and papillary muscles, and hyperelastic and anisotropic mechanical properties of tissues. The biomechanics of the three valves throughout the entire cardiac cycle was simulated before and after Mitraclip(®) implantation, assessing the biomechanical impact of the procedure. For all three simulated MVs, Mitraclip(®) implantation significantly improved systolic leaflets coaptation, without inducing major alterations in systolic peak stresses. Diastolic orifice area was decreased, by up to 58.9%, and leaflets diastolic stresses became comparable, although lower, to systolic ones. Despite established knowledge on the edge-to-edge surgical repair, latest technological advances make its percutanoues implementation a challenging field of research. The modeling approach herein proposed may be expanded to analyze clinical scenarios that are currently critical for Mitraclip(®) implantation, helping the search for possible solutions.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Anciano de 80 o más Años , Algoritmos , Fenómenos Biomecánicos , Femenino , Análisis de Elementos Finitos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Hemodinámica/fisiología , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/anatomía & histología , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/patología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/patología , Modelación Específica para el Paciente , Estrés Mecánico , Técnicas de Sutura , Ultrasonografía , Cicatrización de Heridas/fisiología
18.
J Thorac Cardiovasc Surg ; 150(5): 1303-12.e4, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26277475

RESUMEN

OBJECTIVES: Intraoperative assessment of the proper neochordal length during mitral plasty may be complex sometimes. Patient-specific finite element models were used to elucidate the biomechanical drawbacks underlying an apparently correct mitral repair for isolated posterior prolapse. METHODS: Preoperative patient-specific models were derived from cardiac magnetic resonance images; integrated with intraoperative surgical details to assess the location and extent of the prolapsing region, including the number and type of diseased chordae; and complemented by the biomechanical properties of mitral leaflets, chordae tendineae, and artificial neochordae. We investigated postoperative mitral valve biomechanics in a wide spectrum of different techniques (single neochorda, double neochordae, and preconfigured neochordal loop), all reestablishing adequate valvular competence, but differing in suboptimal millimetric expanded polytetrafluoroethylene suture lengths in a range of ±2 mm, compared with the corresponding "ideal repair." RESULTS: Despite the absence of residual regurgitation, alterations in chordal forces and leaflet stresses arose simulating suboptimal repairs; alterations were increasingly relevant as more complex prolapse anatomies were considered and were worst when simulating single neochorda implantation. Multiple chordae implantations were less sensitive to errors in neochordal length tuning, but associated postoperative biomechanics were hampered when asymmetric configurations were reproduced. Computational outcomes were consistent with the presence and entity of recurrent mitral regurgitation at midterm follow-up of simulated patients. CONCLUSIONS: Suboptimal suture length tuning significantly alters chordal forces and leaflet stresses, which may be key parameters in determining the long-term outcome of the repair. The comparison of the different simulated techniques suggests possible criteria for the selection and implementation of neochordae implantation techniques.


Asunto(s)
Cuerdas Tendinosas/trasplante , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Anuloplastia de la Válvula Mitral/efectos adversos , Insuficiencia de la Válvula Mitral/cirugía , Prolapso de la Válvula Mitral/cirugía , Válvula Mitral/trasplante , Fenómenos Biomecánicos , Cuerdas Tendinosas/patología , Cuerdas Tendinosas/fisiopatología , Simulación por Computador , Análisis de Elementos Finitos , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Imagen por Resonancia Magnética , Válvula Mitral/patología , Válvula Mitral/fisiopatología , Anuloplastia de la Válvula Mitral/instrumentación , Anuloplastia de la Válvula Mitral/métodos , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/fisiopatología , Prolapso de la Válvula Mitral/diagnóstico , Prolapso de la Válvula Mitral/fisiopatología , Modelos Cardiovasculares , Politetrafluoroetileno , Valor Predictivo de las Pruebas , Diseño de Prótesis , Recurrencia , Factores de Riesgo , Técnicas de Sutura , Suturas , Insuficiencia del Tratamiento
19.
Ann Vasc Surg ; 29(6): 1090-6, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26001618

RESUMEN

BACKGROUND: Autologous saphenous vein is considered the gold standard conduit in the femoral-popliteal revascularization for popliteal artery aneurysms (PAAs). In several cases, it may be absent or unsuitable for length or diameter and so it may be considered unfit for a conduit. In such patients, a synthetic graft or the endovascular correction can be useful, but results are controversial. In this retrospective case series, we have analyzed the safety and efficacy of the cryopreserved homograft (CHg) as a conduit in the PAA revascularization. METHODS: In the period between January 2005 and December 2013, 54 PAAs have been treated with an arterial CHg. Indications to surgery were asymptomatic aneurysm with >25-mm diameter in 30 cases (55.6%), ischemic symptoms in 20 (37%), and compressive symptoms in 4 (7.4%). An urgent treatment was performed in 8 cases (14.8%) for severe ischemic symptoms. All cases have been operated by the same vascular team: a posterior surgical approach was preferred whenever possible (33 cases, 61.1%). All patients received a clinical and radiologic follow-up, and all data were collected in a specific database. A >10-mm diameter increase of the conduit was considered significant for an aneurysmatic degeneration. RESULTS: The primary outcomes were complications and reoperation rate, limb salvage, and primary and secondary patency. Secondary outcome was the incidence of aneurysmatic degeneration of the CHg. Mean diameter of the homografts was 6.3 mm (range, 4-8 mm). In the 30-day postoperative period, 7 PAAs (13%) developed a complication: 3 wound infections, 3 graft thrombosis, and 1 anastomotic bleeding. Six cases needed a reoperation: 2 surgical revascularizations, 2 wound debridement, and 1 anastomotic hemostasis; 1 major amputation was necessary for graft failure after the revascularization. Mean follow-up was 34.8 months (range, 1-96). Five cases (9.3%) developed a graft complication with 4 reoperations necessary (7.4%): 2 grafts required a percutaneous transluminal angioplasty for a perigraft stenosis and 2 underwent a femorodistal bypass in CHg for severe ischemic symptoms after CHg occlusion. Another one CHg occlusion was treated conservatively because it was clinically asymptomatic. Primary patency was 96.3%, 93.9%, and 88.3% at 12, 36, and 60 months, respectively; secondary patency was 98.1% at 12, 36, and 60 months. Freedom from amputation resulted in 98.1%. No aneurysmatic degeneration was observed. Univariate and multivariate analysis showed urgent surgery to be independent risk factors for complications, reoperations, and CHg occlusion (P < 0.05). CONCLUSIONS: In this retrospective study, the use of CHg showed to be safe and effective in the surgery of PAAs, either in the short or in the long-term follow-up. Urgent surgery can be considered predictive of graft failure. In our experience, CHg can be considered a good alternative conduit to the autologous saphenous vein.


Asunto(s)
Aneurisma/cirugía , Bioprótesis , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Criopreservación , Arteria Ilíaca/trasplante , Arteria Poplítea/cirugía , Vena Safena/trasplante , Adulto , Anciano , Anciano de 80 o más Años , Aloinjertos , Amputación Quirúrgica , Aneurisma/diagnóstico , Aneurisma/fisiopatología , Implantación de Prótesis Vascular/efectos adversos , Supervivencia sin Enfermedad , Femenino , Humanos , Italia , Recuperación del Miembro , Masculino , Persona de Mediana Edad , Arteria Poplítea/fisiopatología , Complicaciones Posoperatorias/cirugía , Reoperación , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
20.
J Thorac Cardiovasc Surg ; 148(3): 1025-34; discussion 1034, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25052823

RESUMEN

OBJECTIVES: Finite element modeling was adopted to quantitatively compare, for the first time and on a patient-specific basis, the biomechanical effects of a broad spectrum of different neochordal implantation techniques for the repair of isolated posterior mitral leaflet prolapse. METHODS: Cardiac magnetic resonance images were acquired from 4 patients undergoing surgery. A patient-specific 3-dimensional model of the mitral apparatus and the motion of the annulus and papillary muscles were reconstructed. The location and extent of the prolapsing region were confirmed by intraoperative findings, and the mechanical properties of the mitral leaflets, chordae tendineae and expanded polytetrafluoroethylene neochordae were included. Mitral systolic biomechanics was simulated under preoperative conditions and after 5 different neochordal procedures: single neochorda, double neochorda, standard neochordal loop with 3 neochordae of the same length and 2 premeasured loops with 1 common neochordal loop and 3 different branched neochordae arising from it, alternatively one third and two thirds of the entire length. RESULTS: The best repair in terms of biomechanics was achieved with a specific neochordal technique in the single patient, according to the location of the prolapsing region. However, all techniques achieved a slight reduction in papillary muscle forces and tension relief in intact native chordae proximal to the prolapsing region. Multiple neochordae implantation improved the repositioning of the prolapsing region below the annular plane and better redistributed mechanical stresses on the leaflet. CONCLUSIONS: Although applied on a small cohort of patients, systematic biomechanical differences were noticed between neochordal techniques, potentially affecting their short- to long-term clinical outcomes. This study opens the way to patient-specific optimization of neochordal techniques.


Asunto(s)
Simulación por Computador , Implantación de Prótesis de Válvulas Cardíacas , Imagen por Resonancia Magnética , Anuloplastia de la Válvula Mitral , Prolapso de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Modelos Cardiovasculares , Cirugía Asistida por Computador , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Cuerdas Tendinosas/patología , Cuerdas Tendinosas/fisiopatología , Cuerdas Tendinosas/cirugía , Femenino , Análisis de Elementos Finitos , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Interpretación de Imagen Asistida por Computador , Imagenología Tridimensional , Masculino , Válvula Mitral/patología , Válvula Mitral/fisiopatología , Anuloplastia de la Válvula Mitral/instrumentación , Prolapso de la Válvula Mitral/patología , Prolapso de la Válvula Mitral/fisiopatología , Selección de Paciente , Politetrafluoroetileno , Valor Predictivo de las Pruebas , Diseño de Prótesis , Recuperación de la Función , Estrés Mecánico , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA