Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Front Neurosci ; 16: 1018166, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36545536

RESUMEN

In conventional frame-based image sensors, every pixel records brightness information and sends this information to a receiver serially in a scanning fashion. This full-frame readout approach suffers from high bandwidth requirements and increased power consumption with the increasing size of the pixel array. Event-based image sensors are gaining popularity for reducing the bandwidth and power requirements by sending only meaningful data in an event-driven approach with the help of address-event representation (AER) communication protocol. However, the event-based readout suffers from increased latency and timing error when the number of pixels with an event increase. In this paper, we introduce a new field-programmable AER (FP-AER) encoding scheme which offers benefits of both frame-based and event-based approaches. The readout design can be configured "in the field" using configuration bits. We also compare the performance of the proposed design against existing AER-based approaches for imaging applications and show that FP-AER performs best in both scanning and event-based readout.

2.
Nature ; 559(7714): 343-349, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-30022131

RESUMEN

Aberration-corrected optics have made electron microscopy at atomic resolution a widespread and often essential tool for characterizing nanoscale structures. Image resolution has traditionally been improved by increasing the numerical aperture of the lens (α) and the beam energy, with the state-of-the-art at 300 kiloelectronvolts just entering the deep sub-ångström (that is, less than 0.5 ångström) regime. Two-dimensional (2D) materials are imaged at lower beam energies to avoid displacement damage from large momenta transfers, limiting spatial resolution to about 1 ångström. Here, by combining an electron microscope pixel-array detector with the dynamic range necessary to record the complete distribution of transmitted electrons and full-field ptychography to recover phase information from the full phase space, we increase the spatial resolution well beyond the traditional numerical-aperture-limited resolution. At a beam energy of 80 kiloelectronvolts, our ptychographic reconstruction improves the image contrast of single-atom defects in MoS2 substantially, reaching an information limit close to 5α, which corresponds to an Abbe diffraction-limited resolution of 0.39 ångström, at the electron dose and imaging conditions for which conventional imaging methods reach only 0.98 ångström.

3.
Nano Lett ; 18(6): 3746-3751, 2018 06 13.
Artículo en Inglés | MEDLINE | ID: mdl-29775315

RESUMEN

Next-generation, atomically thin devices require in-plane, one-dimensional heterojunctions to electrically connect different two-dimensional (2D) materials. However, the lattice mismatch between most 2D materials leads to unavoidable strain, dislocations, or ripples, which can strongly affect their mechanical, optical, and electronic properties. We have developed an approach to map 2D heterojunction lattice and strain profiles with subpicometer precision and the ability to identify dislocations and out-of-plane ripples. We collected diffraction patterns from a focused electron beam for each real-space scan position with a high-speed, high dynamic range, momentum-resolved detector-the electron microscope pixel array detector (EMPAD). The resulting four-dimensional (4D) phase space data sets contain the full spatially resolved lattice information on the sample. By using this technique on tungsten disulfide (WS2) and tungsten diselenide (WSe2) lateral heterostructures, we have mapped lattice distortions with 0.3 pm precision across multimicron fields of view and simultaneously observed the dislocations and ripples responsible for strain relaxation in 2D laterally epitaxial structures.

4.
J Synchrotron Radiat ; 23(2): 395-403, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26917125

RESUMEN

A wide-dynamic-range imaging X-ray detector designed for recording successive frames at rates up to 10 MHz is described. X-ray imaging with frame rates of up to 6.5 MHz have been experimentally verified. The pixel design allows for up to 8-12 frames to be stored internally at high speed before readout, which occurs at a 1 kHz frame rate. An additional mode of operation allows the integration capacitors to be re-addressed repeatedly before readout which can enhance the signal-to-noise ratio of cyclical processes. This detector, along with modern storage ring sources which provide short (10-100 ps) and intense X-ray pulses at megahertz rates, opens new avenues for the study of rapid structural changes in materials. The detector consists of hybridized modules, each of which is comprised of a 500 µm-thick silicon X-ray sensor solder bump-bonded, pixel by pixel, to an application-specific integrated circuit. The format of each module is 128 × 128 pixels with a pixel pitch of 150 µm. In the prototype detector described here, the three-side buttable modules are tiled in a 3 × 2 array with a full format of 256 × 384 pixels. The characteristics, operation, testing and application of the detector are detailed.


Asunto(s)
Sincrotrones
5.
Microsc Microanal ; 22(1): 237-49, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26750260

RESUMEN

We describe a hybrid pixel array detector (electron microscope pixel array detector, or EMPAD) adapted for use in electron microscope applications, especially as a universal detector for scanning transmission electron microscopy. The 128×128 pixel detector consists of a 500 µm thick silicon diode array bump-bonded pixel-by-pixel to an application-specific integrated circuit. The in-pixel circuitry provides a 1,000,000:1 dynamic range within a single frame, allowing the direct electron beam to be imaged while still maintaining single electron sensitivity. A 1.1 kHz framing rate enables rapid data collection and minimizes sample drift distortions while scanning. By capturing the entire unsaturated diffraction pattern in scanning mode, one can simultaneously capture bright field, dark field, and phase contrast information, as well as being able to analyze the full scattering distribution, allowing true center of mass imaging. The scattering is recorded on an absolute scale, so that information such as local sample thickness can be directly determined. This paper describes the detector architecture, data acquisition system, and preliminary results from experiments with 80-200 keV electron beams.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Microscopía Electrónica de Transmisión de Rastreo/instrumentación , Microscopía Electrónica de Transmisión de Rastreo/métodos , Imagen Óptica/instrumentación , Imagen Óptica/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...