Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
J Med Imaging (Bellingham) ; 11(3): 035002, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38817712

RESUMEN

Purpose: The objective of this study is to evaluate the accuracy of an augmented reality (AR) system in improving guidance, accuracy, and visualization during the subxiphoidal approach for epicardial ablation. Approach: An AR application was developed to project real-time needle trajectories and patient-specific 3D organs using the Hololens 2. Additionally, needle tracking was implemented to offer real-time feedback to the operator, facilitating needle navigation. The AR application was evaluated through three different experiments: examining overlay accuracy, assessing puncture accuracy, and performing pre-clinical evaluations on a phantom. Results: The results of the overlay accuracy assessment for the AR system yielded 2.36±2.04 mm. Additionally, the puncture accuracy utilizing the AR system yielded 1.02±2.41 mm. During the pre-clinical evaluation on the phantom, needle puncture with AR guidance showed 7.43±2.73 mm, whereas needle puncture without AR guidance showed 22.62±9.37 mm. Conclusions: Overall, the AR platform has the potential to enhance the accuracy of percutaneous epicardial access for mapping and ablation of cardiac arrhythmias, thereby reducing complications and improving patient outcomes. The significance of this study lies in the potential of AR guidance to enhance the accuracy and safety of percutaneous epicardial access.

2.
J Appl Physiol (1985) ; 136(3): 606-617, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38328825

RESUMEN

We aimed to develop a large animal model of subcoronary aortic stenosis (AS) to study intracoronary and microcirculatory hemodynamics. A total of three surgical techniques inducing AS were evaluated in 12 sheep. Suturing the leaflets together around a dilator (n = 2) did not result in severe AS. Suturing of a pericardial patch with a variable opening just below the aortic valve (n = 5) created an AS which was poorly tolerated if the aortic valve area (AVA) was too small (0.38-1.02 cm2), but was feasible with an AVA of 1.2 cm2. However, standardization of aortic regurgitation (AR) with this technique is difficult. Therefore, we opted for implantation of an undersized AV-bioprosthesis with narrowing sutures on the leaflets (n = 5). Overall, five sheep survived the immediate postoperative period of which three had severe AS (one patch and two bioprostheses). The surviving sheep with severe AS developed left ventricular hypertrophy and signs of increased filling-pressures. Intracoronary assessment of physiological indices in these AS sheep pointed toward the development of functional microvascular dysfunction, with a significant increase in coronary resting flow and hyperemic coronary resistance, resulting in a significantly higher index of microvascular resistance (IMR) and lower myocardial resistance reserve (MRR). Microscopic analysis showed myocardial hypertrophy and signs of fibrosis without evidence of capillary rarefaction. In a large animal model of AS, microvascular changes are characterized by increased resting coronary flow and hyperemic coronary resistance resulting in increased IMR and decreased MRR. These physiological changes can influence the interpretation of regularly used coronary indices.NEW & NOTEWORTHY In an animal model of aortic valve stenosis (AS), coronary physiological changes are characterized by increased resting coronary flow and hyperemic coronary resistance. These changes can impact coronary indices frequently used to assess concomitant coronary artery disease (CAD). At this point, the best way to assess and treat CAD in AS remains unclear. Our data suggest that fractional flow reserve may underestimate CAD, and nonhyperemic pressure ratios may overestimate CAD severity before aortic valve replacement.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Animales , Ovinos , Microcirculación , Circulación Coronaria , Hemodinámica , Estenosis de la Válvula Aórtica/cirugía , Estenosis Coronaria/cirugía , Estenosis Coronaria/diagnóstico
3.
Eur Heart J Cardiovasc Imaging ; 25(3): 328-336, 2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-37933672

RESUMEN

AIMS: Left bundle branch pacing (LBBP) has been shown to better maintain electrical synchrony compared with right ventricular pacing (RVP), but little is known about its impact on mechanical synchrony. This study investigates whether LBBP better preserves left ventricular (LV) mechanical synchronicity and function compared with RVP. METHODS AND RESULTS: Sixty patients with pacing indication for bradycardia were included: LBBP (n = 31) and RVP (n = 29). Echocardiography was performed before and shortly after pacemaker implantation and at 1-year follow-up. The lateral wall-septal wall (LW-SW) work difference was used as a measure of mechanical dyssynchrony. Septal flash, apical rocking, and septal strain patterns were also assessed. At baseline, LW-SW work difference was small and similar in two groups. SW was markedly decreased, while LW work remained mostly unchanged in RVP, resulting in a larger LW-SW work difference compared with LBBP (1253 ± 687 mmHg·% vs. 439 ± 408 mmHg·%, P < 0.01) at last follow-up. In addition, RVP more often induced septal flash or apical rocking and resulted in more advanced strain patterns compared with LBBP. At 1 year follow-up, LV ejection fraction (EF) and global longitudinal strain (GLS) were more decreased in RVP compared with LBBP (ΔLVEF: -7.4 ± 7.0% vs. 0.3 ± 4.1%; ΔLVGLS: -4.8 ± 4.0% vs. -1.4 ± 2.5%, both P < 0.01). In addition, ΔLW-SW work difference was independently correlated with LV adverse remodelling (r = 0.42, P < 0.01) and LV dysfunction (ΔLVEF: r = -0.61, P < 0.01 and ΔLVGLS: r = -0.38, P = 0.02). CONCLUSION: LBBP causes less LV mechanical dyssynchrony than RVP as it preserves a more physiologic electrical conduction. As a consequence, LBBP appears to preserve LV function better than RVP.


Asunto(s)
Estimulación Cardíaca Artificial , Tabique Interventricular , Humanos , Estimulación Cardíaca Artificial/métodos , Electrocardiografía , Ventrículos Cardíacos/diagnóstico por imagen , Sistema de Conducción Cardíaco , Función Ventricular Izquierda/fisiología , Remodelación Ventricular , Resultado del Tratamiento
5.
J Clin Med ; 12(18)2023 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-37763048

RESUMEN

Background and aim: The presence of mechanical dyssynchrony on echocardiography is associated with reverse remodelling and decreased mortality after cardiac resynchronization therapy (CRT). Contrarily, myocardial scar reduces the effect of CRT. This study investigated how well a combined assessment of different markers of mechanical dyssynchrony and scarring identifies CRT responders. Methods: In a prospective multicentre study of 170 CRT recipients, septal flash (SF), apical rocking (ApRock), systolic stretch index (SSI), and lateral-to-septal (LW-S) work differences were assessed using echocardiography. Myocardial scarring was quantified using cardiac magnetic resonance imaging (CMR) or excluded based on a coronary angiogram and clinical history. The primary endpoint was a CRT response, defined as a ≥15% reduction in LV end-systolic volume 12 months after implantation. The secondary endpoint was time-to-death. Results: The combined assessment of mechanical dyssynchrony and septal scarring showed AUCs ranging between 0.81 (95%CI: 0.74-0.88) and 0.86 (95%CI: 0.79-0.91) for predicting a CRT response, without significant differences between the markers, but significantly higher than mechanical dyssynchrony alone. QRS morphology, QRS duration, and LV ejection fraction were not superior in their prediction. Predictive power was similar in the subgroups of patients with ischemic cardiomyopathy. The combined assessments significantly predicted all-cause mortality at 44 ± 13 months after CRT with a hazard ratio ranging from 0.28 (95%CI: 0.12-0.67) to 0.20 (95%CI: 0.08-0.49). Conclusions: The combined assessment of mechanical dyssynchrony and septal scarring identified CRT responders with high predictive power. Both visual and quantitative markers were highly feasible and demonstrated similar results. This work demonstrates the value of imaging LV mechanics and scarring in CRT candidates, which can already be achieved in a clinical routine.

9.
Circ Cardiovasc Imaging ; 15(11): e014296, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36330792

RESUMEN

BACKGROUND: Septal strain patterns measured by echocardiography reflect the severity of left bundle branch block (LBBB)-induced left ventricular (LV) dysfunction. We investigated whether these LBBB strain stages predicted the response to cardiac resynchronization therapy in an observational study and developed a sheep model of LBBB-induced cardiomyopathy. METHODS: The clinical study enrolled cardiac resynchronization therapy patients who underwent echocardiographic examination with speckle-tracking strain analysis before cardiac resynchronization therapy implant. In an experimental sheep model with pacing-induced dyssynchrony, LV remodeling and strain were assessed at baseline, at 8 and 16 weeks. Septal strain curves were classified into 5 patterns (LBBB-0 to LBBB-4). RESULTS: The clinical study involved 250 patients (age 65 [58; 72] years; 79% men; 89% LBBB) with a median LV ejection fraction of 25 [21; 30]%. Across the stages, cardiac resynchronization therapy resulted in a gradual volumetric response, ranging from no response in LBBB-0 patients (ΔLV end-systolic volume 0 [-12; 15]%) to super-response in LBBB-4 patients (ΔLV end-systolic volume -44 [-64; -18]%) (P<0.001). LBBB-0 patients had a less favorable long-term outcome compared with those in stage LBBB≥1 (log-rank P=0.003). In 13 sheep, acute right ventricular pacing resulted in LBBB-1 (23%) and LBBB-2 (77%) patterns. Over the course of 8-16 weeks, continued pacing resulted in progressive LBBB-induced dysfunction, coincident with a transition to advanced strain patterns (92% LBBB-2 and 8% LBBB-3 at week 8; 75% LBBB-3 and 25% LBBB-4 at week 16) (P=0.023). CONCLUSIONS: The strain-based LBBB classification reflects a pathophysiological continuum of LBBB-induced remodeling over time and is associated with the extent of reverse remodeling in observational cardiac resynchronization therapy-eligible patients.


Asunto(s)
Bloqueo de Rama , Terapia de Resincronización Cardíaca , Ovinos , Animales , Bloqueo de Rama/etiología , Bloqueo de Rama/terapia , Bloqueo de Rama/diagnóstico , Remodelación Ventricular , Electrocardiografía , Función Ventricular Izquierda/fisiología , Volumen Sistólico/fisiología , Resultado del Tratamiento
10.
JACC Cardiovasc Imaging ; 15(12): 2023-2034, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36163339

RESUMEN

BACKGROUND: Shear wave elastography (SWE) has been proposed as a novel noninvasive method for the assessment of myocardial stiffness, a relevant determinant of diastolic function. It is based on tracking the propagation of shear waves, induced, for instance, by mitral valve closure (MVC), in the myocardium. The speed of propagation is directly related to myocardial stiffness, which is defined by the local slope of the nonlinear stress-strain relation. Therefore, the operating myocardial stiffness can be altered by both changes in loading and myocardial mechanical properties. OBJECTIVES: This study sought to evaluate the capability of SWE to quantify myocardial stiffness changes in vivo by varying loading and myocardial tissue properties and to compare SWE against pressure-volume loop analysis, a gold standard reference method. METHODS: In 15 pigs, conventional and high-frame rate echocardiographic data sets were acquired simultaneously with pressure-volume loop data after acutely changing preload and afterload and after inducting an ischemia/reperfusion (I/R) injury. RESULTS: Shear wave speed after MVC significantly increased by augmenting preload and afterload (3.2 ± 0.8 m/s vs 4.6 ± 1.2 m/s and 4.6 ± 1.0 m/s, respectively; P = 0.001). Preload reduction had no significant effect on shear wave speed compared to baseline (P = 0.118). I/R injury resulted in significantly higher shear wave speed after MVC (6.1 ± 1.2 m/s; P < 0.001). Shear wave speed after MVC had a strong correlation with the chamber stiffness constant ß (r = 0.63; P < 0.001) and operating chamber stiffness dP/dV before induction of an I/R injury (r = 0.78; P < 0.001) and after (r = 0.83; P < 0.001). CONCLUSIONS: Shear wave speed after MVC was influenced by both acute changes in loading and myocardial mechanical properties, reflecting changes in operating myocardial stiffness, and was strongly related to chamber stiffness, invasively derived by pressure-volume loop analysis. SWE provides a novel noninvasive method for the assessment of left ventricular myocardial properties.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Válvula Mitral , Animales , Valor Predictivo de las Pruebas , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...