Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Zhonghua Yu Fang Yi Xue Za Zhi ; 55(4): 465-470, 2021 Apr 06.
Artículo en Chino | MEDLINE | ID: mdl-33858057

RESUMEN

Objective: The purpose of the study was to describe the prevalence of myopia and to explore the associated factors of myopia among Han and Yi students aged 5-16 years in Yunnan province, China. Methods: A total of 5 971 Han and Yi students were included in the data analysis from the Yunnan eye study which was conducted from March to August, 2014. Information regarding demographic factors, socioeconomic status and lifestyle-related exposures were collected by per-designed questionnaires. The ophthalmic examinations including distance visual acuity, anterior segment examination, cycloplegic auto-refraction, and ocular motility examination were conducted. Logistic regression models were fitted to estimate the risk factors for myopia. Results: The age of 5 971 subjects was (10.68±2.24)years old, and the total prevalence of myopia and high myopia was 48.05% and 0.59%. Myopia prevalence was found to be higher in Han students compared with Yi ethnicity (50.20% vs. 47.10%,P=0.029). In multivariate analysis, the occurrence of myopia was associated with age (OR=1.28, 95%CI: 1.25-1.31), girls (OR=1.32, 95%CI: 1.18-1.48), increasing reading and writing time per day (OR=1.13, 95%CI: 1.07-1.20), having self-reported myopia among friend(s) (OR=1.15, 95%CI: 1.02-1.29), having myopic father (OR=1.38, 95%CI: 1.06-1.79), having myopic mother (OR=1.43, 95%CI: 1.12-1.83) and higher educated mother (OR=1.24, 95%CI: 1.03-1.51). Conclusions: We observed a high prevalence of myopia among Mangshi students. The presence of myopia was associated with increasing age, girls, increasing reading and writing time per day, having self-reported myopia among friend(s), having myopic father, having myopic and high educated mother.


Asunto(s)
Miopía , Refracción Ocular , Adolescente , Niño , Preescolar , China/epidemiología , Femenino , Humanos , Miopía/epidemiología , Prevalencia , Factores de Riesgo , Encuestas y Cuestionarios , Agudeza Visual
3.
Public Health ; 157: 86-93, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29501986

RESUMEN

OBJECTIVES: The aim of this study is to describe the prevalence and associated factors of spectacles need and ownership among multiethnic school students in rural China. STUDY DESIGN: School-based cross-sectional study. METHODS: This school-based eye study was conducted in Yunnan province located in Southwestern China. Questionnaires were filled out by children with the help of their parents concerning demographic characteristics, spectacles usage, and myopia-related lifestyle exposures. Spectacles need was defined as participants who had an uncorrected visual acuity (VA) of less than 6/12 but could be corrected to more than 6/12 in the better-seeing eye, with myopia of less than -0.5 diopters (D), hyperopia of more than +2.0 D, or astigmatism of more than 0.75 D in both eyes. Definition of spectacles ownership was based on spectacles wearing at school on the examination day. RESULTS: Among the 7681 students aged 5-16 years participating in this study, 7166 (93.3% of the study participants) successfully completed VA tests and questionnaires. The rate of spectacles need among children with an uncorrected VA of 6/12 or worse in either eye was 68.3% (623/912). Among the students who needed spectacles, only 18.9% owned them. Multivariate analyses revealed that spectacles ownership was significantly associated with increasing age (odds ratio [OR]: 1.30; 95% confidence interval [CI]: 1.08-1.55), more time on reading and writing (OR = 1.66; 95% CI: 1.15-2.40), having myopic friend(s) (OR: 1.90; 95% CI: 1.01-3.56), self-awareness of myopia (OR: 6.67; 95% CI: 2.48-17.92), and poorer uncorrected VA (OR: 4.57; 95% CI: 2.78-7.52). CONCLUSIONS: We observed a lower rate of spectacles ownership among rural children compared with those of similar ages in urban China. These findings may have important public health implications for China and other countries regarding vision-related health resources allocation.


Asunto(s)
Diversidad Cultural , Anteojos/estadística & datos numéricos , Necesidades y Demandas de Servicios de Salud , Propiedad/estadística & datos numéricos , Errores de Refracción/etnología , Población Rural/estadística & datos numéricos , Estudiantes/estadística & datos numéricos , Adolescente , Niño , Preescolar , China/epidemiología , Estudios Transversales , Femenino , Humanos , Masculino , Instituciones Académicas , Encuestas y Cuestionarios , Agudeza Visual/fisiología
4.
Zhonghua Yan Ke Za Zhi ; 53(4): 260-265, 2017 Apr 11.
Artículo en Chino | MEDLINE | ID: mdl-28412798

RESUMEN

Objective: To compare the accuracy of three different formulas for intraocular lens power calculation in high myopic eyes with cataract and analyze their influencial factors. Methods: One hundred and three high myopic patients of cataract (103 eyes), with average age of 60.2±8.8 years old (39.0-77.0), including 45 male and 54 female and with axial length ≥ 26 mm were enrolled in this retrospective case-series study. All of them underwent routine ocular examination and IOLMastermeasurement preoperatively and then underwent phacoemulsification through temporal clear-corneal incision with implantation of HumanOptic posterior chamber Intraocular lens (IOL). All analyses were conducted using SPSS version 19.0. Repeated-measures analysis of variance was applied to compare the refractive results one month postoperatively with the predicted IOL powers calculated by SRK/T, Holladay 1, or Haigis formula before surgery. The differences were further compared based on different grouping of axial length (AXL), corneal curvature (K) and corneal astigmatism (CA). The accuracies of the three formulas were analyzed using Bland-Altman analyses and the possible error sources of each formula were analyzed using multiple regression model. Results: The majority of patients enrolled had hyperopic shift after cataract surgery. The mean errors (ME) of the three formulas were SRK/T: 0.70±0.89D, Holladay 1: (1.20±0.88) D and Haigis: (0.60±0.88) D; the mean absolute errors (MAE) of the three formulas were (0.81±0.79) D, (1.23±0.84) D and (0.76±0.74) D, respectively. Both ME and MAE of Holladay formula were significantly greater than the other two formulas (F=86.31, P<0.01). Besides, the proportion of patients having a prediction error within 0.50 D was lower in those using Holladay formula (20.4%, 21/103) than the other two (SRK/T: 38.8%, 40/103, χ(2)=8.41, P<0.01, Haigis: 45.6%, 47/103, χ(2)=14.84, P<0.01). Bland-Altman analyses showed that the accuracies of all the three formulas were acceptable in patients of cataract with high myopia in clinical practice. ME and MAE tended to be larger with longer axial length, larger corneal curvature and astigmatism of the patients in all three formulas. However, in eyes with axial length> 30 mm or corneal curvature ≤43.00 D, the MAE of Haigis formula was lower than that of SRK/T formula (F=63.26,63.94, both P<0.01). The prediction error of SRK/T formula was positively correlated with axial length and corneal astigmatism (F=33.97, r=0.66, ß=0.48, P<0.01 and ß=0.42, P<0.01), while for Holladay and Haigis formulas, in addition to the previous two factors, the errors were also positively correlated with mean corneal curvature (Holladay 1: F=31.26, r=0.72, AXL: ß=0.52, P<0.01, K: ß=0.20, P<0.05 and CA: ß=0.37, P<0.01; Haigis: F=30.96, r=0.72, AXL: ß=0.33, P<0.01, K: ß=0.40, P<0.01 and CA: ß=0.37, P<0.01). Conclusions: In the selection of IOL formula for high myopic patients with cataract, Haigis or SRK/T would reduce the prediction error and serve as the more accurate formulas than Holladay 1. Haigis formula may be more accurate than SRK/T formula in case of AXL>30 mm or K≤43.00 D. (Chin J Ophthalmol, 2017, 53: 260-265).


Asunto(s)
Catarata/complicaciones , Lentes Intraoculares , Miopía/rehabilitación , Adulto , Anciano , Astigmatismo , Longitud Axial del Ojo/patología , Extracción de Catarata , Femenino , Humanos , Hiperopía/etiología , Implantación de Lentes Intraoculares , Cristalino , Masculino , Persona de Mediana Edad , Miopía/complicaciones , Facoemulsificación/métodos , Periodo Posoperatorio , Refracción Ocular , Estudios Retrospectivos , Pruebas de Visión
5.
Lupus ; 25(5): 496-504, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26657736

RESUMEN

Left atrial (LA) function plays a key role in maintaining optimal cardiac output. Left ventricular diastolic dysfunction (LVDD) has been reported in systemic lupus erythematosus (SLE), but whether LA functional abnormalities also occur in patients with SLE is unknown. Toward this aim we evaluated left atrial function and volume by strain and strain rate derived from speckle tracking echocardiography (STE) and their associations with LVDD. Sixty SLE patients were compared with age- and gender-matched normal controls. The LA strain (S) and strain rate (SR) during systole, early diastole and late diastole (SRs, SRe and SRa, respectively) were measured by STE. The LA volume index (LAVI), traditional parameters of LA and left ventricular diastolic function also were analysed. Global strain and positive SRe were significantly reduced in the SLE group compared with the control group (26.2% ± 9.5% vs 32.5% ± 9.8% and -2.4 ± 1.0 s(-1) vs -3.1 ± 1.2 s(-1), both p < 0.05). The SRs in the SLE and control groups were not significantly different (2.1 ± 0.7 s(-1) vs 2.4 ± 0.8 s(-1), p = 0.2). The positive SRa was increased in the SLE group compared with the control group (-2.1 ± 0.8 s(-1) vs -1.6 ± 0.5 s(-1), p < 0.05) and the LAVI was larger in the SLE group than in the control group (32.4 ± 8.0 vs 25.8 ± 7.1 ml/m(2), p < 0.001). Patients with SLE exhibiting varying grades of LVDD displayed significant differences in LA parameters, including LAVI, SRs, SRe and SRa (all p < 0.05). Multivariate linear analysis additionally revealed that SLICC/ACR damage index (SDI) was independently and inversely associated with global strain, SRs and positive SRe. LA functions were changed in SLE patients, demonstrating impairment in conduit function, decrease in storage function and increase in pump function. Meanwhile, the magnitude of this impairment was predictively associated with the severity of LVDD. The results from this study demonstrate that STE is capable of detecting various aspects of LA functional impairment during SLE progression, and should be further explored as a diagnostic tool for improving the outcomes of SLE patients.


Asunto(s)
Función del Atrio Izquierdo , Ecocardiografía Doppler/métodos , Cardiopatías/diagnóstico por imagen , Lupus Eritematoso Sistémico/complicaciones , Adolescente , Adulto , Estudios de Casos y Controles , Distribución de Chi-Cuadrado , Femenino , Cardiopatías/etiología , Cardiopatías/fisiopatología , Humanos , Modelos Lineales , Lupus Eritematoso Sistémico/diagnóstico , Masculino , Persona de Mediana Edad , Análisis Multivariante , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Pronóstico , Reproducibilidad de los Resultados , Factores de Riesgo , Estrés Mecánico , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/fisiopatología , Función Ventricular Izquierda , Adulto Joven
6.
Heart ; 91(4): e25, 2005 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15772174

RESUMEN

A 31 year old man was admitted to hospital for abrupt syncope. Two dimensional echocardiogram in the apical four chamber view showed Ebstein's malformation. This is the first documented case of Ebstein's malformation with atrial septal defect, right cor triatriatum, and a right overt accessory atrioventricular pathway.


Asunto(s)
Anomalías Múltiples/diagnóstico por imagen , Nodo Atrioventricular/fisiopatología , Corazón Triatrial/diagnóstico por imagen , Anomalía de Ebstein/diagnóstico por imagen , Defectos del Tabique Interatrial/diagnóstico por imagen , Adulto , Fibrilación Atrial/etiología , Humanos , Masculino , Síncope/etiología , Ultrasonografía
7.
Chem Commun (Camb) ; (22): 2312-3, 2001 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-12240051

RESUMEN

Two types of multiporphyrin arrays, mediated by PdCl4(2-) complex ions at the air-water interface, were alternately transferred onto solid supports to form three-dimensional organized multilayers by a layer-by-layer method.

8.
Appl Biochem Biotechnol ; 84-86: 409-18, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-10849807

RESUMEN

An indium tin oxide (ITO) electrode was chemically modified by one layer of viologen (VIO) derivative, which possessed a persistent and reproducible electrochemical response. A monolayer of a thermal stable hydrogenase from Thiocapsa roseopersicina was stabilized on a synthesized poly-L-lysine subphase surface and transferred onto the electrode for fabrication of an ITO-VIO-hydrogenase heterogeneous system. Electrochemical properties of both the ITO-VIO monolayer and the heterogeneous ITO-VIO-hydrogenase system have been investigated. Hydrogen evolution could be measured by potentiostating the VIO-hydrogenase-covered ITO electrode to "electroplate" [(VIO+)n]surf, and a large increase in hydrogen evolution was observed when using an electrolyte solution containing sodium dithionite. We discuss the possible electron transfer process.


Asunto(s)
Electroquímica/instrumentación , Enzimas Inmovilizadas/metabolismo , Hidrógeno , Hidrogenasas/metabolismo , Electroquímica/métodos , Potenciometría , Thiocapsa/enzimología , Compuestos de Estaño
9.
Spectrochim Acta A Mol Biomol Spectrosc ; 56(14): 2645-51, 2000 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-11145330

RESUMEN

Some europium complexes with pyrazolone derivatives and 1,10-phenanthroline were synthesized and characterized. The europium ion was found to coordinate to O atoms of the pyrazolone derivatives and to N atoms of 1,10-phenanthroline. A strongly ligand-localized UV absorption leads to the europium-centered emissions between 580 and 750 nm which were assigned as the 5D0-->7F0,1,2,3,4 and 5D1-->7F3,4 transitions. A low site symmetry for the Eu3+ ion was confirmed from the observation of 5D0-->7F0 emission and from the splitting of the other bands. In contrast to many Eu complexes that have been investigated a rather weak emission was measured by introduction of a Schiff base to form a ternary complex with the pyrazolone derivative. The long fluorescence lifetimes of these complexes suggest an energy transfer process from ligands to Eu3+ ion through the triplet state of the ligands.


Asunto(s)
Europio/química , Pirazoles/química , Pirazolonas , Espectrometría de Fluorescencia/métodos , Espectrofotometría Ultravioleta
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA