Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
IEEE Trans Med Imaging ; PP2024 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-38781069

RESUMEN

Open-sided magnetic particle imaging (OS-MPI) has garnered significant interest due to its potential for interventional applications. However, the system matrix calibration in OS-MPI using sequential scans is a time-consuming task and susceptible to the low signal-to-noise ratio (SNR) resulting from the small calibration sample size. These challenges have hindered the practical implementation of system matrix-based reconstruction for sequentially scanned OS-MPI. To address these issues, we propose a novel calibration method, named sequential scan-based single-dimension multi-voxel calibration (SS-SDMVC), to efficiently obtain a high-SNR system matrix. This method was implemented in a cylindrical field of view (FOV), where a bar calibration sample parallel to the field-free line (FFL) was shifted along a fixed radial direction. A standard image reconstruction process was also introduced to verify the feasibility of SS-SDMVC. Through simulations, we analyzed the effects of noise levels and scanner imperfections on the SS-SDMVC-based reconstruction and demonstrated its robustness. In experiments, we compared the imaging performance of SS-SDMVC and the sequential scan-based traditional cubic-FOV SMC. The results showed that SS-SDMVC reduced the number of measurements by a factor of 210.94 and achieved higher reconstruction quality. Therefore, SS-SDMVC is expected to improve the reconstruction quality of human-scale or high-gradient FFL MPI scanners.

2.
IEEE Trans Biomed Eng ; 71(4): 1209-1218, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37938949

RESUMEN

OBJECTIVE: Open-sided field-free line magnetic particle imaging (OS FFL MPI) is a novel medical imaging system configuration that has received significant attention in recent years. However, the measurement-based system matrix (SM) image reconstruction for OS FFL MPI typically requires multiple angle calibration (MAC), which is time-consuming in practice. METHODS: To address this issue, we propose a fast 2D SM generation method that requires only a single angle calibration (SAC). The SAC method exploits the rotational invariance of the system function. Based on the measured single angle system function, the system function is rotated to generate system functions at other angles, and then the SM for image reconstruction is constructed. Then, we conducted various simulation experiments and built an OS FFL MPI scanner to evaluate the proposed SAC method. RESULTS: The experiments demonstrating the effectiveness of SAC in reducing calibration workload, requiring fewer scanning numbers while maintaining a similar image reconstruction quality compared to MAC method. Furthermore, the SM generated by SAC produces consistent imaging results with the SM generated by MAC, regardless of the interpolation algorithms, the number of rotation angles, or the signal-to-noise ratios employed in phantom imaging experiments. CONCLUSION: SAC has been experimentally verified to reduce acquisition time while maintaining accurate and robust reconstruction performance. SIGNIFICANCE: The significance of SAC lies in its contribution to improving calibration efficiency in OS FFL MPI, potentially facilitating the implementation of MPI in a wider range of applications.


Asunto(s)
Algoritmos , Diagnóstico por Imagen , Calibración , Fantasmas de Imagen , Relación Señal-Ruido , Fenómenos Magnéticos , Procesamiento de Imagen Asistido por Computador/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...