Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Magn Reson Imaging ; 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38299767

RESUMEN

BACKGROUND: Serum creatinine (Scr) may be not suited to timely and accurately reflect kidney injury related to chronic liver disease. Currently, the ability of arterial spin labeling (ASL) and blood oxygen level-dependent (BOLD) sequences to evaluate renal blood flow (RBF) and blood oxygen in chronic liver disease remains to be verified. PURPOSE: To investigate the value of ASL and BOLD imaging in evaluating hemodynamics and oxygenation changes during kidney injury in an animal model of chronic liver disease. STUDY TYPE: Prospective. ANIMAL MODEL: Chronic liver disease model was established by subcutaneous injection of carbon tetrachloride. Forty-three male Sprague-Dawley rats (8 weeks) were divided into a pathological group (0, 2, 4, 6, 8, 12 weeks, each group: N = 6) and a continuous-scanning group (N = 7). FIELD STRENGTH/SEQUENCE: 3-T, ASL, BOLD, and T2W. ASSESSMENT: Regions of interest in the cortex (CO), outer stripe of the outer medulla (OSOM), and inner stripe of the outer medulla (ISOM) are manually delineated. The RBF and T2* values at each time point (0, 2, 4, 6, 8, 12 weeks) are measured and compared. Hematoxylin-eosin score (HE Score, damage area scoring method), alpha-smooth muscle actin (α-SMA), hypoxia-inducible factor-1alpha (HIF-1α), peritubular capillar (PTC) density, Scr, and neutrophil gelatinase-associated lipocalin were harvested. STATISTICAL TESTS: Analysis of variance, Spearman correlation analysis, Kruskal-Wallis tests, and receiver operating characteristic analysis with the area under the curve (AUC). A P-value <0.05 was considered statistically significant. RESULTS: Renal RBF and T2* values of CO, OSOM, and ISOM were significantly different from baseline. Both RBF and T2* were significantly correlated with HE Score, α-SMA, HIF-1α, and PTC density (|r| = 0.406-0.853). RBF demonstrated superior diagnostic capability in identifying severe kidney injury in this model of chronic liver disease (AUC = 0.964). DATA CONCLUSION: Imaging by ASL and BOLD may detect renal hemodynamics and oxygenation changes related to chronic liver disease early. EVIDENCE LEVEL: 5 TECHNICAL EFFICACY: Stage 2.

2.
J Cancer ; 15(3): 764-775, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38213737

RESUMEN

The tyrosine-kinase receptor that is specified by the KIT locus is demarcated by KITLG. This multifaceted factor is instrumental during in-utero germ and neural cell maturation and hematopoiesis, ostensibly reflecting its role in facilitating cell migration. Concurrently, KITLG is prone to a mutation in germ cell tumors, entailing a presumed connection to tumorigenesis. Despite this, the intricacies of its function in breast cancer and the relevant mechanisms remain elusive. Multiple independent databases depict a consistently low expression of KITLG within tissues affected by triple-negative breast cancers (TNBC), a trend strongly coupled with reduced survival rates. Interestingly, non-triple-negative breast cancers exhibit a markedly high expression of KITLG compared to the norm. An initial analysis of the GEO database speculates that KITLG may serve as an oncogene suppressor in TNBC, hinting at varied roles for KITLG isoforms within this disease context. In conclusion, our preliminary analysis offers valuable insights into the role and expression pattern of KITLG in TNBC. We provide evidence supporting its consideration as a promising new prognostic marker, thereby potentially enriching therapeutic strategies for TNBC. Indeed, given the limited advances in molecularly targeted therapy for TNBC, a significant need exists for a more precise therapeutic approach and a comprehensive understanding of its inherent mechanisms of action.

3.
Abdom Radiol (NY) ; 48(6): 1945-1954, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36928333

RESUMEN

PURPOSE: To evaluate the performance and repeatability assessing liver, spleen, and kidney stiffness with magnetic resonance elastography (MRE), using arrays of pneumatic passive drivers. METHODS: An array of four flexible, pneumatically activated passive drivers for abdominal MRE were developed and tested in this study. Multiple MRE acquisitions were performed prospectively in a series of eleven volunteers, with activation of all combinations of the four drivers, individually and simultaneously. MRE exams were repeated three times to study within-day and between-day test-retest repeatability. Semi-quantitative evaluation of wave propagation and penetration, and quantitative assessment of tissue stiffness was conducted for liver, spleen, and kidneys. RESULTS: When driver location and amplitude were sufficient to achieve necessary shear wave illumination in any given region of interest, the results showed excellent test-retest repeatability in abdominal organ stiffness with both single and multiple driver configurations. The results confirmed that multiple driver arrays provided suitable shear wave illumination over a larger region of the abdomen, allowing more reliable stiffness measurements in multiple organs. MRE assessment of the spleen was found to be prone to effects of excessive shear wave amplitude, however. CONCLUSION: A multiple driver array provides shear wave illumination over a larger region of the abdomen than obtained with a single driver, for MRE assessment of multiple abdominal organs, providing excellent test-retest repeatability in stiffness measurements. However, careful tuning of the location and amplitude of each driver is essential to achieve consistent results.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Hígado/diagnóstico por imagen , Abdomen/diagnóstico por imagen , Bazo/diagnóstico por imagen , Riñón , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética/métodos
4.
BMC Gastroenterol ; 22(1): 430, 2022 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-36210451

RESUMEN

BACKGROUND: We aimed to evaluate the correlation between the pathological changes and multi-parameter MRI characteristics of liver regeneration (LR) in a standard partial hepatectomy (PH) rat model. METHODS: Seventy Sprague-Dawley rats were randomly divided into two groups: MR scan group (n = 14) and pathologic analysis (PA) group (n = 56). All 14 rats in the MR group underwent liver T1 mapping, T2 mapping, and diffusion kurtosis imaging before and the 1st, 2nd, 3rd, 5th, 7th, 14th, and 21st day after 70% hepatectomy. Seven rats in the PA group were euthanized at each time point to determine Ki-67 indices, hepatocyte size (HTS), steatosis grade, and inflammation score. RESULTS: Liver T1 and T2 values increased to maximum on day 2 (P < 0.001 vs. baseline), D and K values decreased to minimum on day 3 and 2, respectively (P < 0.001 vs. baseline), then all parameters returned to baseline gradually. Hepatocyte Ki-67, hepatocyte size, steatosis grade, and inflammation score initially increased after surgery (P < 0.05 vs. baseline), followed by a gradual decline over time. Both T2 and K values correlated well with Ki-67 indices (r = 0.765 and - 0.807, respectively; both P < 0.001), inflammation (r = 0.809 and - 0.724, respectively; both P < 0.001), steatosis grade (r = 0.814 and - 0.725, respectively; both P < 0.001), and HTS (r = 0.830 and - 0.615, respectively; both P < 0.001). CONCLUSIONS: PH induced liver changes that can be observed on MRI. The MRI parameters correlate with the LR activity and allow monitoring of LR process.


Asunto(s)
Hiperplasia Nodular Focal , Regeneración Hepática , Animales , Imagen de Difusión por Resonancia Magnética/métodos , Hepatectomía/métodos , Hiperplasia/patología , Inflamación/patología , Antígeno Ki-67 , Hígado/diagnóstico por imagen , Hígado/patología , Hígado/cirugía , Imagen por Resonancia Magnética/métodos , Ratas , Ratas Sprague-Dawley
5.
Acad Radiol ; 29(12): 1810-1818, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35871060

RESUMEN

RATIONALE AND OBJECTIVES: To evaluate liver perfusion changes and their effect on liver regeneration (LR) after partial hepatectomy (PH) using intravoxel incoherent motion (IVIM) and T2* mapping in a rat model. METHODS: One hundred and two rats underwent 30%, 50%, or 70% PH. Within each group (n = 34), rats in MR imaging subgroup (n = 10) underwent liver IVIM and T2* mapping before and within 2 h, 1, 2, 3, 5, 7, 14, and 21 days post-PH to measure D*, perfusion fraction (PF), and T2* values. Three rats from histologic subgroup (n = 24) sacrificed at each time point for hepatocyte Ki-67 indices and diameters measurement. RESULTS: Liver D* and PF values decreased immediately post-PH, then returned to original level as LR progressed in all groups. PF values in 70% PH group were significantly lower than in the other two groups (p < .05). D* and PF values correlated significantly with hepatocyte Ki-67 indices (r = -0.588 to -0.915; p < .05) and hepatocyte diameter (r = -0.555 to -0.792; p < .05). Liver T2* values decreased immediately within 2 h post-PH, then increased to a high level and followed with returning to original level gradually. The duration of the high T2* levels was consistent with Ki-67 indices. CONCLUSIONS: Liver perfusion decreased immediately followed with increasing gradually after PH. IVIM and T2* mapping are promising methods for monitoring changes of liver perfusion. IVIM-derived D* value is the best indicator in reflecting the process of LR noninvasively.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Hepatectomía , Ratas , Animales , Ratas Sprague-Dawley , Imagen de Difusión por Resonancia Magnética/métodos , Antígeno Ki-67 , Movimiento (Física) , Imagen por Resonancia Magnética/métodos , Perfusión , Hígado/diagnóstico por imagen , Hígado/cirugía , Hígado/patología
6.
Front Physiol ; 13: 822763, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35250624

RESUMEN

PURPOSE: To determine whether intravoxel incoherent motion (IVIM) parameters correlate with liver regeneration and function recovery after partial hepatectomy (PH) in rats with carbon tetrachloride (CCl4)-induced liver fibrosis. METHODS: Sixty-two adult Sprague-Dawley rats were divided into the control group and the fibrosis group with CCl4 injection for 8 weeks. At the end of the 8th week, all rats received left lateral lobe liver resection. Within each group, IVIM imaging (n = 10/group) and histologic and biochemical analyses (n = 3/group/time point) were performed pre- and post-PH (on days 1, 2, 3, 5, 7, 14, and 21). Differences in liver IVIM parameters and correlation between IVIM parameters and Ki-67 indices, hepatocyte diameter, alanine transaminase (ALT), aspartate aminotransferase (AST), and total bilirubin (TBil) values were analyzed. RESULTS: Post-PH, liver true diffusion coefficient (D) values decreased and pseudodiffusion coefficient (D*) and perfusion fraction (PF) values increased, then recovered to pre-PH levels gradually in both fibrosis and control rats. PF in fibrosis group were significantly higher than in controls from 3 to 21 days (P < 0.05). In fibrosis rats, both Ki-67 indices and hepatocyte diameters increased, and a strong correlation was found between PF and Ki-67 indices (r = -0.756; P = 0.03), D* and PF values and ALT, AST, and TBil values (r = -0.762 to -0.905; P < 0.05). In control rats, only hepatocyte diameters increased, and all IVIM parameters correlated well with hepatocyte diameters, ALT, AST and TBil values (r = 0.810 to -1.000; P < 0.05). CONCLUSION: The regeneration pattern in fibrotic liver tissue was different compared with control livers. IVIM parameters can monitor liver regeneration and functional recovery non-invasively after PH.

7.
J Magn Reson Imaging ; 55(5): 1393-1404, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34499757

RESUMEN

BACKGROUND: Arterial spin labeling (ASL) has been proven to be effective in ischemia-induced acute kidney injury (AKI); however, validation of ASL magnetic resonance imaging (MRI) is limited in AKI in the presence of cirrhosis. PURPOSE: To investigate the feasibility of ASL in revealing renal blood flow (RBF) changes in kidney injury in the presence of cirrhosis and to assess its value in the early diagnosis of disease. STUDY TYPE: Longitudinal. ANIMAL MODEL: Rats were randomized into baseline group (N = 3), sham surgery group (N = 18), and common bile duct ligation (BDL) group (N = 48). All groups were divided into six subgroups based on different sacrificed time points. FIELD STRENGTH/SEQUENCE: 3 T scanner, prototypic pulsed ASL sequence using flow-sensitive alternating inversion recovery preparation, half-Fourier acquisition single-shot turbo spin echo sequence. ASSESSMENT: RBF measurement was performed by ASL. Hematoxylin-eosin (HE) score, Hypoxia-inducible factor-1alpha (HIF-1α) score, peritubular capillar (PTC) density, alanine aminotransferase, aspartate aminotransferase, serum total bilirubin, total bile acids, serum creatinine (Scr), and blood urea nitrogen (BUN) were harvested. STATISTICAL TESTS: Analysis of variance, Pearson's correlation coefficient, and receiver operating characteristic curves were performed. P < 0.05 was considered statistically significant. RESULTS: RBF, HE score, HIF-1α score, and PTC density after BDL were significantly different from baseline. RBF was highly correlated with HE score, HIF-1α score, and PTC density (r = -0.7598, r = -0.7434, r = 0.6406, respectively). RBF and Scr began to differ significantly from baseline at day 3 and 7 after intervention, respectively. The areas under the curves of RBF, Scr, and BUN for distinguishing non-AKI from AKI in cirrhosis were 1.00, 0.888, and 0.911, while those for distinguishing mild from severe kidney injury were 0.961, 0.830, and 0.857, respectively. DATA CONCLUSION: ASL allows the longitudinal assessment of the degree of AKI induced by cholestatic cirrhosis in rats and can serve as a noninvasive marker for the early and accurate diagnosis of AKI. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 2.


Asunto(s)
Lesión Renal Aguda , Riñón , Lesión Renal Aguda/diagnóstico por imagen , Lesión Renal Aguda/etiología , Animales , Conducto Colédoco , Femenino , Riñón/irrigación sanguínea , Riñón/diagnóstico por imagen , Cirrosis Hepática/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Masculino , Perfusión , Ratas , Marcadores de Spin
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...