Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Zhonghua Wai Ke Za Zhi ; 58(6): 457-463, 2020 Jun 01.
Artículo en Chino | MEDLINE | ID: mdl-32498486

RESUMEN

Objective: To examine the clinical effects of the treatment of knee osteoarthritis patients with kinematic alignment technique of total knee replacement (KA-TKA) assisted by patient-specific instrumentation (PSI). Methods: The clinical data of 14 patients with knee osteoarthritis treated with unilateral KA-TKA assisted by PSI at Department of Orthopaedic Surgery, Beijing Chaoyang Hospital Affiliated to Capital Medical University from May 2018 to August 2019 were analyzed retrospectively. There were 6 males and 8 females, aged 66.6 years (range: 56 to 79 years), 9 left knees and 5 right knees. The operation time, soft tissue release and extra varus or valgus osteotomy were recorded. The data of osteotomy blocks were measured and compared with the corresponding position of the prostheses. The hip knee ankle angle (HKA), the mechanical distal femoral lateral angle (mLDFA) and the proximal tibial medial angle (MPTA) were measured before and 3 months after the operation. The knee joint functional score (KS-F) , knee joint clinical score (KS-C) and the Western Ontario McMaster (WOMAC) Osteoarthritis Index were recorded and compared by paired t test or Wilcoxon non-parametric test. Results: The operation time was (81.8±16.9) minutes (range: 60 to 115 minutes), 2 cases were manually increased varus osteotomy by 2 mm and 1 patient received lateral retinaculum release. There was no extra medial or lateral soft tissue release. Intraoperative measurement of the resection showed that the femoral side mismatch was within 2 mm. The medial and lateral condyle, the medial and lateral posterior condyles were relatively overcut by 0.50 mm, 0.21 mm, 0.93 mm, and 0.71 mm, respectively. The tibial side mismatch was within 1.5 mm, the medial and lateral plateau were relatively undercut by 0.43 mm and 0.32 mm. HKA was corrected from (8.8±5.6) ° to (1.6±4.3) ° (t=20.723, P=0.000) .KS-C improved from 28.21±13.47 preoperative to 78.07±8.01 postoperative (t=-16.570, P=0.000); KS-F improved from 41.00±15.25 preoperative to 84.93±10.85 postoperative (t=-14.675, P=0.000).WOMAC Osteoarthritis Index decreased from 53.5 (25.75) (M(Q(R))) preoperative to 5.5 (5.25) postoperative (Z=-3.297, P=0.001) .No statistically significant difference was found in mLDFA and MPTA before and after surgery. No significant patellofemoral complication was recorded during follow-up time. Conclusions: PSI assisted TKA resection has high accuracy. KA-TKA aims to restore the native anatomy of the knee joint, only corrects the malalignment of lower extremities caused by articular cartilage wear, with less interference to soft tissues, easy to obtain satisfactory knee joint laxity and has a promising early clinical effect.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Artroplastia de Reemplazo de Rodilla/métodos , Osteoartritis de la Rodilla/cirugía , Anciano , Fenómenos Biomecánicos , Desviación Ósea/etiología , Desviación Ósea/prevención & control , Femenino , Humanos , Articulación de la Rodilla/fisiopatología , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/fisiopatología , Modelación Específica para el Paciente , Estudios Retrospectivos , Cirugía Asistida por Computador
2.
Zhonghua Wai Ke Za Zhi ; 57(8): 596-600, 2019 Aug 01.
Artículo en Chino | MEDLINE | ID: mdl-31422629

RESUMEN

Objective: To investigate the microbiological test, antibiotic sensitivity and surgical treatment of periprosthetic joint infection(PJI) cases in post total hip arthroplasty (THA) and total knee arthroplasty (TKA) patients. Methods: A retrospective cross-sectional survey was conducted on 318 patients who underwent THA or TKA in 9 clinical centers in Beijing from January 2014 to December 2016.The data of microbiology, antibiotic sensitivity and surgical treatment were collected.The average age of patients was (62.3±13.1) years old (range: 21-86 years old), including 145 males and 173 females.The body mass index was (25.6±3.8) kg/m (2) (range: 15.6-38.1 kg/m(2)). Results: In total, 318 patients had microorganisms detected by periprosthetic tissue culture or synovial fluid culture, 209 cases (65.7%) had Gram-positive bacteria, 29 cases (9.1%) had Gram-negative bacteria, 10 cases (3.1%) had fungi, 3 cases (0.9%) had non-tuberculous mycobacteria, 72 cases (22.6%) were negative, 69 cases (21.7%) had methicillin-resistant bacteria. The antibiotic sensitivity results showed that the overall resistance rate of penicillin, cefuroxime, amoxicillin+clavulanic acid was 79.9%, 69.9%, and 68.1%, respectively; meropenem, vancomycin, and linezolid resistance rate was 0. For the treatment methods of hip and knee PJI, two-stage revision surgery acounted for 72.9% (108/148) and 64.1% (109/170), respectively. One-stage revision surgery accounted for 21.6% (32/148) and 7.6% (13/170), and open debridement surgery accounted for 4.7%(7/148) and 26.4% (45/170). Conclusions: Gram-positive bacteria was still the main pathogen of PJI.The methicillin-resistant bacteria and rare bacteria should be payed attention to. The Majority of hip and knee PJI cases were treated by two-stage revision surgery.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Infecciones Relacionadas con Prótesis/microbiología , Adulto , Anciano , Anciano de 80 o más Años , Beijing , Estudios Transversales , Farmacorresistencia Microbiana , Femenino , Humanos , Masculino , Pruebas de Sensibilidad Microbiana , Persona de Mediana Edad , Infecciones Relacionadas con Prótesis/tratamiento farmacológico , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Prótesis/cirugía , Reoperación , Estudios Retrospectivos , Adulto Joven
3.
Zhonghua Yi Xue Za Zhi ; 98(27): 2148-2151, 2018 Jul 17.
Artículo en Chino | MEDLINE | ID: mdl-30032515
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...