Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
2.
J Am Soc Echocardiogr ; 37(7): 698-705, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38490315

RESUMEN

Interventional echocardiography is a rapidly growing field within the disciplines of cardiology and anesthesiology, with the rise of advanced transcatheter procedures making skilled imagers more important than ever. However, these procedures also involve frequent manipulation of the transesophageal echocardiography probe, which means interventional echocardiographers (IEs) are at risk of long-term occupational radiation exposure. Studies have shown that radiation exposure is linked to various health issues, including cancer, cataracts, hypertension, hyperlipidemia, endothelial dysfunction, vascular aging, and early atherosclerosis. While there is increasing awareness of the occupational radiation dose limits and the need for better shielding methods, the importance of radiation safety for the IE is still not sufficiently prioritized in most cardiac catheterization laboratories/hybrid operating rooms. This is partly due to a paucity of studies looking at long-term radiation exposure to the IE, as this field is newer than that of interventional cardiologists.


Asunto(s)
Exposición Profesional , Exposición a la Radiación , Humanos , Exposición Profesional/prevención & control , Exposición a la Radiación/prevención & control , Ecocardiografía/métodos , Ultrasonografía Intervencional/métodos , Protección Radiológica/métodos , Dosis de Radiación
3.
Circ Cardiovasc Interv ; 17(2): e013298, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38235547

RESUMEN

BACKGROUND: Frailty associates with worse outcomes after transcatheter aortic valve replacement (TAVR). Sarcopenia underlies frailty, but the association between a comprehensive assessment of sarcopenia-muscle mass, strength, and performance-and outcomes after TAVR has not been examined. METHODS: From a multicenter prospective registry of patients with symptomatic severe aortic stenosis undergoing TAVR, 445 who had a preprocedure computed tomography and clinical assessment of frailty were included. Cross-sectional muscle (psoas and paraspinal) areas were measured on computed tomography and indexed to height. Gait speed and handgrip strength were obtained, and patients were dichotomized into fast versus slow; strong versus weak; and normal versus low muscle mass. As measures of body composition, cross-sectional fat (subcutaneous and visceral) was measured and indexed to height. RESULTS: The frequency of patients who were slow, weak, and had low muscle mass was 56%, 59%, and 42%, respectively. Among the 3 components of sarcopenia, only slower gait speed (muscle performance) was independently associated with increased post-TAVR mortality (adjusted hazard ratio, 1.12 per 0.1 m/s decrease [95% CI, 1.04-1.21]; P=0.004; adjusted hazard ratio, 1.38 per 1 SD decrease [95% CI, 1.11-1.72]; P=0.004). Meeting multiple sarcopenia criteria was not associated with higher mortality risk than fewer. Lower indexed visceral fat area (adjusted hazard ratio, 1.48 per 1 SD decrease [95% CI, 1.15-1.89]; P=0.002) was associated with mortality but indexed subcutaneous fat was not. Death occurred in 169 (38%) patients. CONCLUSIONS: Among patients with symptomatic severe aortic stenosis and comprehensive sarcopenia and body composition phenotyping, gait speed was the only sarcopenia measure associated with post-TAVR mortality. Lower visceral fat was also associated with increased risk pointing to an obesity paradox also observed in other patient populations. These findings reinforce the clinical utility of gait speed as a measure of risk and a potential target for adjunctive interventions alongside TAVR to optimize clinical outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Fragilidad , Sarcopenia , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Sarcopenia/diagnóstico por imagen , Sarcopenia/complicaciones , Fragilidad/diagnóstico , Fragilidad/complicaciones , Resultado del Tratamiento , Fuerza de la Mano , Estudios Transversales , Medición de Riesgo , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Composición Corporal , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Factores de Riesgo
4.
Circ Cardiovasc Interv ; 16(8): e012875, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37503662

RESUMEN

BACKGROUND: Depression and cognitive dysfunction (CD) are not routinely screened for in patients before transcatheter aortic valve replacement (TAVR) and their association with postprocedural outcomes is poorly understood. The objectives of this study are to determine the prevalence of depression and CD in patients with aortic stenosis undergoing TAVR and evaluate their association with mortality and quality of life. METHODS: We analyzed a prospective, multicenter TAVR registry that systematically screened patients for preexisting depression and CD with the Patient Health Questionnaire-2 and Mini-Cog, respectively. The associations with mortality were assessed with Cox proportional hazard models and quality of life (Kansas City Cardiomyopathy Questionnaire and EuroQol visual analogue scale) were evaluated using multivariable ordinal regression models. RESULTS: A total of 884 patients were included; median follow-up was 2.88 years (interquartile range=1.2-3.7). At baseline, depression was observed in 19.6% and CD in 31.8%. In separate models, after adjustment, depression (HR, 1.45 [95% CI, 1.13-1.86]; P<0.01) and CD (HR, 1.27 [95% CI, 1.02-1.59]; P=0.04) were each associated with increased mortality. Combining depression and CD into a single model, mortality was greatest among those with both depression and CD (n=62; HR, 2.06 [CI, 1.44-2.96]; P<0.01). After adjustment, depression was associated with 6.6 (0.3-13.6) points lower on the Kansas City Cardiomyopathy Questionnaire 1-year post-TAVR and 6.7 (0.5-12.7) points lower on the EuroQol visual analogue scale. CD was only associated with lower EuroQol visual analogue scale. CONCLUSIONS: Depression and CD are common in patients that undergo TAVR and are associated with increased mortality and worse quality of life. Depression may be a modifiable therapeutic target to improve outcomes after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Cardiomiopatías , Disfunción Cognitiva , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Calidad de Vida , Estudios Prospectivos , Depresión/diagnóstico , Depresión/epidemiología , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/epidemiología , Disfunción Cognitiva/diagnóstico , Disfunción Cognitiva/epidemiología , Disfunción Cognitiva/etiología , Atención Dirigida al Paciente , Cardiomiopatías/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Factores de Riesgo
5.
J Am Heart Assoc ; 12(13): e029542, 2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37345820

RESUMEN

Background Studies in mice and small patient subsets implicate metabolic dysfunction in cardiac remodeling in aortic stenosis, but no large comprehensive studies of human metabolism in aortic stenosis with long-term follow-up and characterization currently exist. Methods and Results Within a multicenter prospective cohort study, we used principal components analysis to summarize 12 echocardiographic measures of left ventricular structure and function pre-transcatheter aortic valve implantation in 519 subjects (derivation). We used least absolute shrinkage and selection operator regression across 221 metabolites to define metabolic signatures for each structural pattern and measured their relation to death and multimorbidity in the original cohort and up to 2 validation cohorts (N=543 for overall validation). In the derivation cohort (519 individuals; median age, 84 years, 45% women, 95% White individuals), we identified 3 axes of left ventricular remodeling, broadly specifying systolic function, diastolic function, and chamber volumes. Metabolite signatures of each axis specified both known and novel pathways in hypertrophy and cardiac dysfunction. Over a median of 3.1 years (205 deaths), a metabolite score for diastolic function was independently associated with post-transcatheter aortic valve implantation death (adjusted hazard ratio per 1 SD increase in score, 1.54 [95% CI, 1.25-1.90]; P<0.001), with similar effects in each validation cohort. This metabolite score of diastolic function was simultaneously associated with measures of multimorbidity, suggesting a metabolic link between cardiac and noncardiac state in aortic stenosis. Conclusions Metabolite profiles of cardiac structure identify individuals at high risk for death following transcatheter aortic valve implantation and concurrent multimorbidity. These results call for efforts to address potentially reversible metabolic biology associated with risk to optimize post-transcatheter aortic valve implantation recovery, rehabilitation, and survival.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Animales , Ratones , Anciano de 80 o más Años , Masculino , Multimorbilidad , Estudios Prospectivos , Resultado del Tratamiento , Válvula Aórtica/cirugía , Función Ventricular Izquierda
10.
J Am Soc Echocardiogr ; 36(4): 350-365, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36841670

RESUMEN

Transcatheter therapies for structural heart disease continue to grow at a rapid pace, and echocardiography is the primary imaging modality used to support such procedures. Transesophageal echocardiographic guidance of structural heart disease procedures must be performed by highly skilled echocardiographers who can provide rapid, accurate, and high-quality image acquisition and interpretation in real time. Training standards are needed to ensure that interventional echocardiographers have the necessary expertise to perform this complex task. This document provides guidance on all critical aspects of training for cardiology and anesthesiology trainees and postgraduate echocardiographers who plan to specialize in interventional echocardiography. Core competencies common to all transcatheter therapies are reviewed in addition to competencies for each specific transcatheter procedure. A core principle is that the length of interventional echocardiography training or achieved procedure volumes are less important than the demonstration of procedure-specific competencies within the milestone domains of knowledge, skill, and communication.


Asunto(s)
Cardiología , Cardiopatías , Humanos , Estados Unidos , Ecocardiografía/métodos , Ecocardiografía Transesofágica/métodos , Sociedades Médicas
11.
J Am Heart Assoc ; 11(19): e026529, 2022 10 04.
Artículo en Inglés | MEDLINE | ID: mdl-36172966

RESUMEN

Background Global longitudinal strain (GLS) is a sensitive measure of left ventricular function and a risk marker in severe aortic stenosis. We sought to determine whether biomarkers of cardiac damage (cardiac troponin) and stress (NT-proBNP [N-terminal pro-B-type natriuretic peptide]) could complement GLS to identify patients with severe aortic stenosis at highest risk. Methods and Results From a multicenter prospective cohort of patients with symptomatic severe aortic stenosis who underwent transcatheter aortic valve implantation, we measured absolute GLS (aGLS), cardiac troponin, and NT-proBNP at baseline in 499 patients. Left ventricular ejection fraction <50% was observed in 19% and impaired GLS (aGLS <15%) in 38%. Elevations in cardiac troponin and NT-proBNP were present in 79% and 89% of those with impaired GLS, respectively, as compared with 63% and 60% of those with normal GLS, respectively (P<0.001 for each). aGLS <15% was associated with increased mortality in univariable analysis (P=0.009), but, in a model with both biomarkers, aGLS, and clinical covariates included, aGLS was not associated with mortality; elevation in each biomarker was associated with an increased hazard of mortality (adjusted hazard ratio, >2; P≤0.002 for each) when the other biomarker was elevated, but not when the other biomarker was normal (interaction P=0.015). Conclusions Among patients with symptomatic severe aortic stenosis undergoing transcatheter aortic valve implantation, elevations in circulating cardiac troponin and NT-proBNP are more common as GLS worsens. Biomarkers of cardiac damage and stress are independently associated with mortality after transcatheter aortic valve implantation, whereas GLS is not. These findings may have implications for risk stratification of asymptomatic patients to determine optimal timing of valve replacement.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Biomarcadores , Humanos , Péptido Natriurético Encefálico , Estudios Prospectivos , Estudios Retrospectivos , Volumen Sistólico , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Troponina , Función Ventricular Izquierda
12.
J Am Heart Assoc ; 11(7): e023466, 2022 04 05.
Artículo en Inglés | MEDLINE | ID: mdl-35301869

RESUMEN

Background Left ventricular hypertrophy (LVH) is associated with increased mortality risk and rehospitalization after transcatheter aortic valve replacement among those with severe aortic stenosis. Whether cardiac troponin (cTnT) and NT-proBNP (N-terminal pro-B-type natriuretic peptide) risk stratify patients with aortic stenosis and without LVH is unknown. Methods and Results In a multicenter prospective registry of 923 patients with severe aortic stenosis undergoing transcatheter aortic valve replacement, we included 674 with core-laboratory-measured LV mass index, cTnT, and NT-proBNP. LVH was defined by sex-specific guideline cut-offs and elevated biomarker levels were based on age and sex cut-offs. Adjusted Cox proportional hazards models evaluated associations between LVH and biomarkers and all-cause death out to 5 years. Elevated cTnT and NT-proBNP were present in 82% and 86% of patients with moderate/severe LVH, respectively, as compared with 66% and 69% of patients with no/mild LVH, respectively (P<0.001 for each). After adjustment, compared with no/mild LVH, moderate/severe LVH was associated with an increased hazard of mortality (adjusted hazard ratio [aHR], 1.34; 95% CI 1.01-1.77, P=0.043). cTnT and NT-proBNP each risk stratified patients with moderate/severe LVH (P<0.05). In a model with both biomarkers and LVH included, elevated cTnT (aHR, 2.08; 95% CI 1.45-3.00, P<0.001) and elevated NT-proBNP (aHR, 1.46; 95% CI 1.00-2.11, P=0.049) were each associated with increased mortality risk, whereas moderate/severe LVH was not (P=0.15). Conclusions Elevations in circulating cTnT and NT-proBNP are more common as LVH becomes more pronounced but are also observed in those with no/minimal LVH. As measures of maladaptive remodeling and cardiac injury, cTnT and NT-proBNP predict post-transcatheter aortic valve replacement mortality better than LV mass index. These findings may have important implications for risk stratification and treatment of patients with aortic stenosis.


Asunto(s)
Estenosis de la Válvula Aórtica , Hipertrofia Ventricular Izquierda , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Biomarcadores , Femenino , Humanos , Masculino , Péptido Natriurético Encefálico , Fragmentos de Péptidos , Factores de Riesgo
16.
Innovations (Phila) ; 15(4): 389-392, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32628078

RESUMEN

Variability exists regarding the timing and duration of anticoagulation after surgical ablation for atrial fibrillation and bioprosthetic mitral valve replacement (MVR). We report a case in which a patient developed a massive left atrial (LA) thrombus after MVR and left-sided radiofrequency ablation (LRFA). Despite acutely elevated gradients across the bioprosthetic valve, the patient remained asymptomatic and hemodynamically stable; thus, a multidisciplinary, patient-centered discussion was had and the patient was treated successfully with oral anticoagulation.


Asunto(s)
Anticoagulantes/uso terapéutico , Fibrilación Atrial/cirugía , Cardiopatías/etiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Insuficiencia de la Válvula Mitral/cirugía , Ablación por Radiofrecuencia/efectos adversos , Trombosis/etiología , Bioprótesis , Ecocardiografía , Femenino , Atrios Cardíacos , Cardiopatías/tratamiento farmacológico , Humanos , Persona de Mediana Edad , Válvula Mitral/cirugía , Cuidados Posoperatorios , Complicaciones Posoperatorias/prevención & control , Factores de Riesgo , Trombosis/tratamiento farmacológico
17.
J Thorac Cardiovasc Surg ; 157(3): 874-882.e8, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30454980

RESUMEN

OBJECTIVE: The observed-to-expected 30-day mortality ratio (O:E ratio) is a standard metric by which transcatheter aortic valve replacement (TAVR) trials have been evaluated. Early TAVR trials consistently demonstrated O:E ratio less than 0.6 after TAVR when based on the Society for Thoracic Surgery Predicted Risk of Mortality (STS-PROM) for surgical aortic valve replacement. Recent published results from the Transcatheter Valve Therapy (TVT) Registry have demonstrated O:E ratios of 1.0. We evaluated our own O:E ratios for TAVR to investigate this discordance. METHODS: Data were collected prospectively for TAVR patients from 2008 through 2015 (N = 546) and were reviewed retrospectively. The observed mortality and STS-PROM were calculated to formulate O:E ratios and were compared over a variety of subgroups. RESULTS: Overall, the O:E ratio for 30-day mortality was 0.4 and significantly less than 1 (P < .001; 95% confidence interval, 0.25-0.63). The O:E ratio relationship remained less than 0.5 for patients with low (STS-PROM < 4), moderate (STS-PROM = 4-8) and high risk (STS-PROM > 8). The O:E ratio was significantly higher for transapical patients (O:E ratio = 0.8) when compared with transfemoral patients (O:E ratio = 0.2). Lastly, O:E ratios for both commercial (O:E ratio = 0.5) and research (O:E ratio = 0.3) patients were similar (P = .337), and both were significantly less than 1 (P = .007 and P < .001, respectively). CONCLUSIONS: The STS-PROM consistently overestimated 30-day mortality after TAVR. Achieving an O:E ratio less than 0.6 may be a realistic goal for all TAVR programs. While an accurate and specific risk calculator for 30-day mortality after TAVR remains to be established, our data suggest that current TVT results are not acceptable for commercial TAVR and that programs with an O:E ratio greater than 0.6, based on the STS-PROM, should reevaluate internal processes to improve their results.

18.
J Cardiothorac Vasc Anesth ; 33(3): 796-807, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30064851

RESUMEN

The development of transcatheter interventions to provide a minimally invasive alternative to open surgical repair has revolutionized the care of patients with valvular heart disease. Recently, this technology has been expanded to allow for the treatment of pathology of the mitral valve. This review discusses the anesthetic considerations for patients presenting for transcatheter management of mitral valve disease, including transcatheter mitral valve replacement (TMVR) and transcatheter mitral valve repair (TMVRep). The initial focus is on the current literature on transcatheter interventions for mitral valve pathologies as well as current and developing technology for TMVR and TMVRep. The authors' institutional experience with anesthetic management for the TMVR and TMVRep procedures is described, including potential pitfalls and complications, concluding with a discussion of the role of transesophageal echocardiography in the care of this patient population.


Asunto(s)
Anestesia/métodos , Anestésicos/administración & dosificación , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Cateterismo Cardíaco/métodos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Anestesia/normas , Anestésicos/normas , Estenosis de la Válvula Aórtica/tratamiento farmacológico , Estenosis de la Válvula Aórtica/cirugía , Cateterismo Cardíaco/normas , Prótesis Valvulares Cardíacas/normas , Humanos , Insuficiencia de la Válvula Mitral/tratamiento farmacológico , Insuficiencia de la Válvula Mitral/cirugía
19.
Ann Thorac Surg ; 103(5): 1399-1405, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-27765175

RESUMEN

BACKGROUND: Smaller transcatheter aortic valve replacement (TAVR) delivery systems have increased the number of patients eligible for transfemoral procedures while decreasing the need for transaortic (TAo) or transapical (TA) access. As a result, newer TAVR centers are likely to have less exposure to these alternative access techniques, making it harder to achieve proficiency. The purpose of this study was to evaluate the learning curve for TAVR approaches and compare perioperative outcomes. METHODS: From January 2008 to December 2014, 400 patients underwent TAVR (transfemoral, n = 179; TA, n = 120; and TAo, n = 101)). Learning curves were constructed using metrics of contrast utilization, procedural, and fluoroscopy times. Outcomes during the learning curve were compared with after proficiency was achieved. RESULTS: Depending on the metric, learning curves for all three routes differed slightly but all demonstrated proficiency by the 50th case. There were no significant differences in procedural times whereas improvements in contrast use were most notable for TA (69 ± 40 mL versus 50 ± 23 mL, p = 0.002). For both TA and TAo, fewer patients received transfusions once proficiency was reached (62% versus 34%, p = 0.003, and 42% versus 14%, p = 0.002, respectively). No differences in 30-day or 1-year mortality were seen before or after proficiency was reached for any approach. CONCLUSIONS: The learning curves for TA and TAo are distinct but technical proficiency begins to develop by 25 cases and becomes complete by 50 cases for both approaches. Given the relatively low volume of alternative access, achieving technical proficiency may take significant time. However, technical proficiency had no effect on 30-day or 1-year mortality for any access approach.


Asunto(s)
Instituciones Cardiológicas , Curva de Aprendizaje , Reemplazo de la Válvula Aórtica Transcatéter/educación , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Competencia Clínica , Medios de Contraste/administración & dosificación , Femenino , Necesidades y Demandas de Servicios de Salud , Humanos , Comunicación Interdisciplinaria , Colaboración Intersectorial , Estimación de Kaplan-Meier , Masculino , Tempo Operativo , Selección de Paciente , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/mortalidad , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...