Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Mol Pharm ; 21(4): 1965-1976, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38516985

RESUMEN

Hydrogen/deuterium exchange mass spectrometry (HDX-MS) previously elucidated the interactions between excipients and proteins for liquid granulocyte colony stimulating factor (G-CSF) formulations, confirming predictions made using computational structure docking. More recently, solid-state HDX mass spectrometry (ssHDX-MS) was developed for proteins in the lyophilized state. Deuterium uptake in ssHDX-MS has been shown for various proteins, including monoclonal antibodies, to be highly correlated with storage stability, as measured by protein aggregation and chemical degradation. As G-CSF is known to lose activity through aggregation upon lyophilization, we applied the ssHDX-MS method with peptide mapping to four different lyophilized formulations of G-CSF to compare the impact of three excipients on local structure and exchange dynamics. HDX at 22 °C was confirmed to correlate well with the monomer content remaining after lyophilization and storage at -20 °C, with sucrose providing the greatest protection, and then phenylalanine, mannitol, and no excipient leading to progressively less protection. Storage at 45 °C led to little difference in final monomer content among the formulations, and so there was no discernible relationship with total deuterium uptake on ssHDX. Incubation at 45 °C may have led to a structural conformation and/or aggregation mechanism no longer probed by HDX at 22 °C. Such a conformational change was observed previously at 37 °C for liquid-formulated G-CSF using NMR. Peptide mapping revealed that tolerance to lyophilization and -20 °C storage was linked to increased stability in the small helix, loop AB, helix C, and loop CD. LC-MS HDX and NMR had previously linked loop AB and loop CD to the formation of a native-like state (N*) prior to aggregation in liquid formulations, suggesting a similar structural basis for G-CSF aggregation in the liquid and solid states.


Asunto(s)
Medición de Intercambio de Deuterio , Factor Estimulante de Colonias de Granulocitos , Humanos , Deuterio/química , Medición de Intercambio de Deuterio/métodos , Excipientes/química , Factor Estimulante de Colonias de Granulocitos/química , Espectrometría de Masas/métodos , Proteínas/química
2.
Compr Rev Food Sci Food Saf ; 22(5): 3984-4003, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37530543

RESUMEN

Food allergy remains a public health, business, and regulatory challenge. Risk analysis (RA) and risk management (RM) of food allergens are of great importance and analysis for food allergens is necessary for both. The current workhorse techniques for allergen analysis (enzyme linked immunosorbent assay [ELISA] and real-time polymerase chain reaction) exhibit recognized challenges including variable and antibody specific responses and detection of species DNA rather than allergen protein, respectively. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) enables protein identification, with potential for multiplex analysis and traceability to the System of International units (SI), aiding global measurement standardization. In this review, recent literature has been systematically reviewed to assess progress in LC-MS/MS and define the potential and benefits of matrix-assisted laser desorption/ionization-time-of-flight MS (MALDI-ToF-MS) technology for allergen analysis. MALDI-ToF-MS of initially intact protein is already applied to verify in silico-derived peptide sequences for LC-MS/MS analysis. We describe the origins of MALDI and its future perspectives, including affinity bead-assisted assays coupled to MALDI. Based on the proliferation of reliable and reproducible MALDI-based clinical applications, the technique should emulate the detection capability (sensitivity) of established allergen detection techniques, whilst reducing technical support and having equivalent multiplexing potential to competing techniques, for example, LC-MS/MS and ELISA. Although unlikely to offer inherent SI traceability, MALDI-based allergen analysis will complement existing MS approaches for allergens. Affinity bead-MALDI appears capable of higher throughput at lower cost per sample than almost any existing technique, enabling repeated sub-sampling as a way to reduce representative sampling issues.


Asunto(s)
Proteínas , Espectrometría de Masas en Tándem , Cromatografía Liquida/métodos , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Espectrometría de Masas en Tándem/métodos , Alérgenos/análisis , Rayos Láser
3.
Front Mol Biosci ; 10: 1125791, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36733436
4.
Clin Chem Lab Med ; 61(7): 1235-1244, 2023 06 27.
Artículo en Inglés | MEDLINE | ID: mdl-36815732

RESUMEN

OBJECTIVES: In clinical pratice, tau protein measurement generally relies on immunoassays (IAs), whose major drawback is the lack of results comparability due to differences in selectivity and/or calibration. This underlines the importance of establishing a traceability chain for total tau (t-tau) measurements. The objective of this work is to develop a higher order candidate reference measurement procedure (RMP) for the absolute quantification of t-tau in cerebrospinal fluid (CSF). METHODS: To calibrate the candidate RMP and establish metrological traceability to the SI units, a primary calibrator consisting in a highly purified recombinant protein was sourced. Its purity was evaluated by liquid chromatography coupled with high resolution mass spectrometry (LC-HRMS) and the protein mass fraction in solution was certified by amino acid analysis (AAA). An isotopically-labelled homologue was obtained to develop a candidate RMP by isotope dilution mass spectrometry (IDMS) for t-tau absolute quantification in CSF. Calibration blends and quality control (QC) materials were gravimetrically prepared and subjected to the same preparation workflow as CSF samples, followed by LC-HRMS analysis in Parallel Reaction Monitoring (PRM) mode. RESULTS: A primary calibrator has been developed and an IDMS candidate RMP has been validated for CSF t-tau. The candidate RMP was used to certify t-tau concentration in three pools of CSF (low, medium, high). CONCLUSIONS: The candidate RMP will pave the road towards global standardization of CSF t-tau measurements. Together with commutable Certified Reference Materials (CRMs), it will allow evaluating and improving the accuracy and comparability of results provided by IAs.


Asunto(s)
Espectrometría de Masas en Tándem , Proteínas tau , Humanos , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Estándares de Referencia , Aminoácidos/análisis , Calibración
5.
Int J Mol Sci ; 23(13)2022 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-35806226

RESUMEN

Neurofilament light chain (Nf-L) is a well-known biomarker for axonal damage; however, the corresponding circulating Nf-L analyte in cerebrospinal fluid (CSF) is poorly characterized. We therefore isolated new monoclonal antibodies against synthetic peptides, and these monoclonals were characterized for their specificity on brain-specific intermediate filament proteins. Two highly specific antibodies, ADx206 and ADx209, were analytically validated for CSF applications according to well-established criteria. Interestingly, using three different sources of purified Nf-L proteins, a significant impact on interpolated concentrations was observed. With a lower limit of analytical sensitivity of 100 pg/mL using bovine Nf-L as the calibrator, we were able to quantify the Nf-L analyte in each sample, and these Nf-L concentrations were highly correlated to the Uman diagnostics assay (Spearman rho = 0.97, p < 0.001). In the clinical diagnostic groups, the new Nf-L ELISA could discriminate patients with Alzheimer's disease (AD, n = 20) from those with frontotemporal lobe dementia (FTD, n = 20) and control samples with subjective cognitive decline (SCD, n = 20). Henceforth, this novel Nf-L ELISA with well-defined specificity and epitopes can be used to enhance our understanding of harmonizing the use of Nf-L as a clinically relevant marker for neurodegeneration in CSF.


Asunto(s)
Enfermedad de Alzheimer , Disfunción Cognitiva , Demencia Frontotemporal , Enfermedad de Pick , Enfermedad de Alzheimer/líquido cefalorraquídeo , Enfermedad de Alzheimer/diagnóstico , Péptidos beta-Amiloides/líquido cefalorraquídeo , Animales , Biomarcadores/líquido cefalorraquídeo , Calibración , Bovinos , Disfunción Cognitiva/diagnóstico , Ensayo de Inmunoadsorción Enzimática , Demencia Frontotemporal/líquido cefalorraquídeo , Humanos , Filamentos Intermedios , Proteínas de Neurofilamentos/líquido cefalorraquídeo , Proteínas tau/líquido cefalorraquídeo
6.
Front Mol Biosci ; 9: 866843, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35874615

RESUMEN

Monoclonal antibodies (mAbs) are widely used as analytical components in immunoassays to detect target molecules in applications such as clinical diagnostics, food analysis and drug discovery. Functional groups are often conjugated to lysine or cysteine residues to aid immobilization of mAbs or to enable their detection in an antibody antigen complex. Good assay performance depends on the affinity and specificity of the mAbs for the antigen. The conjugation reaction however can cause higher order structural (HOS) changes and ultimately affect the assay performance. In this study, four differently conjugated mAbs were selected as model systems and characterized by mass spectrometry. Particularly, intact protein analysis by liquid-chromatography mass-spectrometry (LC-MS) was performed to determine the amount and distribution of conjugation. Hydrogen deuterium exchange mass spectrometry (HDX-MS) experiments were carried out for the structural characterization of the conjugated mAbs. Immunoassay experiments were performed to monitor the effects of conjugation on the binding properties of the antibodies selected. Good agreement between the mass spectrometry and binding experiment results was found. Particularly, it was noted that the overall structural flexibility of the antibodies increases upon cysteine conjugation and decreases for lysine conjugation. The conjugation of mAbs with bulky functional groups tends to decrease the deuterium uptake kinetics due to induced steric effects. Overall, this study shows correlations between conjugation, structure and function of immunoassay antibodies and the benefits of mass spectrometry to improve understanding of the conjugation reaction and provide insights that can predict immunoassay performance.

7.
Mol Pharm ; 19(2): 616-629, 2022 02 07.
Artículo en Inglés | MEDLINE | ID: mdl-34965730

RESUMEN

The protein engineering and formulation of therapeutic proteins for prolonged shelf-life remain a major challenge in the biopharmaceutical industry. Understanding the influence of mutations and formulations on the protein structure and dynamics could lead to more predictive approaches to their improvement. Previous intrinsic fluorescence analysis of the chemically denatured granulocyte colony-stimulating factor (G-CSF) suggested that loop AB could subtly reorganize to form an aggregation-prone intermediate state. Hydrogen deuterium exchange mass spectrometry (HDX-MS) has also revealed that excipient binding increased the thermal unfolding transition midpoint (Tm) by stabilizing loop AB. Here, we have combined protein engineering with biophysical analyses and HDX-MS to reveal that increased exchange in a core region of the G-CSF comprising loop AB (ABI, a small helix, ABII) and loop CD packed onto helix B and the beginning of loop BC leads to a decrease in Tm and higher aggregation rates. Furthermore, some mutations can increase the population of the aggregation-prone conformation within the native ensemble, as measured by the greater local exchange within this core region.


Asunto(s)
Factor Estimulante de Colonias de Granulocitos , Espectrometría de Masas de Intercambio de Hidrógeno-Deuterio , Medición de Intercambio de Deuterio/métodos , Excipientes/química , Factor Estimulante de Colonias de Granulocitos/química , Factor Estimulante de Colonias de Granulocitos/genética , Conformación Proteica , Ingeniería de Proteínas , Proteínas
8.
Mol Pharm ; 17(12): 4637-4651, 2020 12 07.
Artículo en Inglés | MEDLINE | ID: mdl-33112626

RESUMEN

Assuring the stability of therapeutic proteins is a major challenge in the biopharmaceutical industry, and a better molecular understanding of the mechanisms through which formulations influence their stability is an ongoing priority. While the preferential exclusion effects of excipients are well known, the additional presence and impact of specific protein-excipient interactions have proven to be more elusive to identify and characterize. We have taken a combined approach of in silico molecular docking and hydrogen deuterium exchange-mass spectrometry (HDX-MS) to characterize the interactions between granulocyte colony-stimulating factor (G-CSF), and some common excipients. These interactions were related to their influence on the thermal-melting temperatures (Tm) for the nonreversible unfolding of G-CSF in liquid formulations. The residue-level interaction sites predicted in silico correlated well with those identified experimentally and highlighted the potential impact of specific excipient interactions on the Tm of G-CSF.


Asunto(s)
Composición de Medicamentos/métodos , Excipientes/química , Filgrastim/química , Espectrometría de Masas de Intercambio de Hidrógeno-Deuterio , Simulación del Acoplamiento Molecular , Estabilidad Proteica , Desplegamiento Proteico
9.
Alzheimers Dement ; 16(11): 1493-1503, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32755010

RESUMEN

INTRODUCTION: Reference materials based on human cerebrospinal fluid were certified for the mass concentration of amyloid beta (Aß)1-42 (Aß42 ). They are intended to be used to calibrate diagnostic assays for Aß42 . METHODS: The three certified reference materials (CRMs), ERM-DA480/IFCC, ERM-DA481/IFCC and ERM-DA482/IFCC, were prepared at three concentration levels and characterized using isotope dilution mass spectrometry methods. Roche, EUROIMMUN, and Fujirebio used the three CRMs to re-calibrate their immunoassays. RESULTS: The certified Aß42 mass concentrations in ERM-DA480/IFCC, ERM-DA481/IFCC, and ERM-DA482/IFCC are 0.45, 0.72, and 1.22 µg/L, respectively, with expanded uncertainties (k = 2) of 0.07, 0.11, and 0.18 µg/L, respectively. Before re-calibration, a good correlation (Pearson's r > 0.97), yet large biases, were observed between results from different commercial assays. After re-calibration the between-assay bias was reduced to < 5%. DISCUSSION: The Aß42 CRMs can ensure the equivalence of results between methods and across platforms for the measurement of Aß42 .


Asunto(s)
Péptidos beta-Amiloides/líquido cefalorraquídeo , Inmunoensayo/normas , Calibración , Humanos , Inmunoensayo/métodos , Estándares de Referencia
10.
J Am Soc Mass Spectrom ; 31(3): 553-564, 2020 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-32008322

RESUMEN

As monoclonal antibodies (mAbs) rapidly emerge as a dominant class of therapeutics, so does the need for suitable analytical technologies to monitor for changes in protein higher order structure (HOS) of these biomolecules. Reference materials (RM) serve a key analytical purpose of benchmarking the suitability and robustness of both established and emerging analytical procedures for both drug producers and regulators. Here, two simple enzymatic protocols for generating Fc-glycan variants from the NISTmAb RM are described and both global and localized changes in HOS between the RM and these Fc-glycan variants are characterized using hydrogen deuterium exchange-mass spectrometry (HDX-MS) and ion mobility spectrometry-mass spectrometry (IMS-MS) measurements. An alternative statistical approach is described where measurement thresholds that differentiate between measurement variability and significant structural changes were established on the basis of experimental data. Measurements revealed decreases in structural stability correlating with the degree of Fc-glycan structure loss, especially at the CH2/CH3 domain interface. These data promote the use of this RM and these Fc-glycan variants for establishing the sensitivity of and validating analytical methods for the detection of HOS measurements of mAbs.


Asunto(s)
Anticuerpos Monoclonales Humanizados/química , Anticuerpos Monoclonales/química , Inmunoglobulina G/química , Espectrometría de Movilidad Iónica/métodos , Polisacáridos/análisis , Glicosilación , Humanos , Espectrometría de Movilidad Iónica/normas , Modelos Moleculares , Conformación Proteica , Dominios Proteicos , Estándares de Referencia
11.
J AOAC Int ; 101(1): 152-161, 2018 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-29202899

RESUMEN

Assessing the recovery of food allergens from solid processed matrixes is one of the most difficult steps that needs to be overcome to enable the accurate quantification of protein allergens by immunoassay and MS. A feasibility study is described herein applying International System of Units (SI)-traceably quantified milk protein solutions to assess recovery by an improved extraction method. Untargeted MS analysis suggests that this novel extraction method can be further developed to provide high recoveries for a broad range of food allergens. A solution of α-casein was traceably quantified to the SI for the content of α-S1 casein. Cookie dough was prepared by spiking a known amount of the SI-traceable quantified solution into a mixture of flour, sugar, and soya spread, followed by baking. A novel method for the extraction of protein food allergens from solid matrixes based on proteolytic digestion was developed, and its performance was compared with the performance of methods reported in the literature.


Asunto(s)
Alérgenos/análisis , Análisis de los Alimentos/métodos , Espectrometría de Masas/métodos , Proteínas de la Leche/análisis , Hipersensibilidad a los Alimentos
12.
J AOAC Int ; 101(1): 162-169, 2018 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-29202918

RESUMEN

It is now well known that an incident investigated in the United Kingdom in 2015 of cumin alleged to be contaminated with almond, a risk for people with almond allergy, was caused by the Prunus species, Prunus mahaleb. In the United Kingdom, the Government Chemist offers a route of technical appeal from official findings in the food control system. Findings of almond in two official samples, cumin and paprika, which had prompted action to exclude the consignments from the food chain, were so referred. Herein are described the approaches deployed to resolve the analytical issues during the investigation of the incidents. The cross-reactivity of ELISA to Prunus species was confirmed, and although this is useful in screening for the genus, orthogonal techniques are required to identify the species and confirm its presence. Two novel PCR assays were developed: one specific for P. mahaleb and the other a screening method capable of identifying common Prunus DNA. Peptides unique to almond and mahaleb were identified, permitting LC-tandem MS and criteria were developed for peptide identification to forensic standards. This work enables a staged approach to be taken to any future incident thought to involve Prunus species and provides a template for the investigation of similar incidents.


Asunto(s)
Alérgenos/análisis , Ensayo de Inmunoadsorción Enzimática , Análisis de los Alimentos , Contaminación de Alimentos/análisis , Hipersensibilidad a los Alimentos , Prunus dulcis/química , Espectrometría de Masas , Biología Molecular , Prunus dulcis/genética , Reino Unido
13.
Food Chem ; 245: 289-296, 2018 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-29287373

RESUMEN

The need for an analytical procedure for the identification of allergens present at trace levels in foods was highlighted by conflicting results in a case of contamination of the spice cumin. The application of a bottom-up proteomics experiment was investigated to identify marker peptides for potential contaminant nuts which could then be monitored with high specificity and sensitivity by selective reaction monitoring experiments. The method developed allowed for the distinction between two closely related Prunus species, almond and mahaleb, in two different spices, cumin and paprika. The paprika sample was found to be contaminated with almond and the cumin sample, contaminated at a much lower level, was found to be contaminated with mahaleb. The method could be applied to any protein-dense food matrix allergen so long as suitable control and reference samples can be acquired.


Asunto(s)
Cromatografía Liquida/métodos , Contaminación de Alimentos/análisis , Límite de Detección , Espectrometría de Masas/métodos , Prunus/química , Especias/análisis , Alérgenos/análisis , Hipersensibilidad a los Alimentos , Prunus/inmunología
14.
Clin Chem Lab Med ; 55(9): 1397-1406, 2017 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-28426429

RESUMEN

BACKGROUND: B-type natriuretic peptide (BNP) is a 32 amino acid cardiac hormone routinely measured by immunoassays to diagnose heart failure. While it is reported that immunoassay results can vary up to 45%, no attempt of standardization and/or harmonization through the development of certified reference materials (CRMs) or reference measurement procedures (RMPs) has yet been carried out. METHODS: B-type natriuretic peptide primary calibrator was quantified traceably to the International System of Units (SI) by both amino acid analysis and tryptic digestion. A method for the stabilization of BNP in plasma followed by protein precipitation, solid phase extraction (SPE) and liquid chromatography (LC) mass spectrometry (MS) was then developed and validated for the quantification of BNP at clinically relevant concentrations (15-150 fmol/g). RESULTS: The candidate reference method was applied to the quantification of BNP in a number of samples from the UK NEQAS Cardiac Markers Scheme to demonstrate its applicability to generate reference values and to preliminary evaluate the commutability of a potential CRM. The results from the reference method were consistently lower than the immunoassay results and discrepancy between the immunoassays was observed confirming previous data. CONCLUSIONS: The application of the liquid chromatography-mass spectrometry (LC-MS) method to the UK NEQAS samples and the correlation of the results with the immunoassay results shows the potential of the method to support external quality assessment schemes, to improve understanding of the bias of the assays and to establish RMPs for BNP measurements. Furthermore, the method has the potential to be multiplexed for monitoring circulating truncated forms of BNP.


Asunto(s)
Péptido Natriurético Encefálico/sangre , Biomarcadores/sangre , Cromatografía Liquida , Humanos , Inmunoensayo , Espectrometría de Masas , Péptido Natriurético Encefálico/aislamiento & purificación , Extracción en Fase Sólida
15.
J Am Soc Mass Spectrom ; 28(6): 1192-1202, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28374315

RESUMEN

Hydrogen-deuterium exchange mass spectrometry (HDX-MS) is an important tool for measuring and monitoring protein structure. A bottom-up approach to HDX-MS provides peptide level deuterium uptake values and a more refined localization of deuterium incorporation compared with global HDX-MS measurements. The degree of localization provided by HDX-MS is proportional to the number of peptides that can be identified and monitored across an exchange experiment. Ion mobility spectrometry (IMS) has been shown to improve MS-based peptide analysis of biological samples through increased separation capacity. The integration of IMS within HDX-MS workflows has been commercialized but presently its adoption has not been widespread. The potential benefits of IMS, therefore, have not yet been fully explored. We herein describe a comprehensive evaluation of traveling wave ion mobility integrated within an online-HDX-MS system and present the first reported example of UDMSE acquisition for HDX analysis. Instrument settings required for optimal peptide identifications are described and the effects of detector saturation due to peak compression are discussed. A model system is utilized to confirm the comparability of HDX-IM-MS and HDX-MS uptake values prior to an evaluation of the benefits of IMS at increasing sample complexity. Interestingly, MS and IM-MS acquisitions were found to identify distinct populations of peptides that were unique to the respective methods, a property that can be utilized to increase the spatial resolution of HDX-MS experiments by >60%. Graphical Abstract ᅟ.


Asunto(s)
Medición de Intercambio de Deuterio/métodos , Espectrometría de Movilidad Iónica/métodos , Espectrometría de Masas/métodos , Mapeo Peptídico/métodos , Sistemas en Línea , Proteínas/análisis , Proteínas/química , Proteómica/métodos , Reproducibilidad de los Resultados , Albúmina Sérica Bovina/análisis , Transferrina/análisis , Transferrina/química
16.
Anal Chem ; 86(13): 6525-32, 2014 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-24856175

RESUMEN

To manage and inform diagnostic or therapeutic decisions, measurement results which are accurate, specific, and comparable between laboratories are required. Two challenges associated with this are the definition of the measurand and the commutability of the reference standard used. Once the measurand is defined, the next step in improving standardization is developing traceable quantification methods for proteins in biological fluids. A novel reference method for the quantification of recombinant human growth hormone (rhGH) in serum has been developed using multistep sample cleanup at the protein level, tryptic digestion, and isotope dilution mass spectrometry (IDMS). Critical considerations for using isotopically labeled rhGH as the internal standard are described. A bulk serum sample was prepared at the clinically relevant level of 10 ng/g and quantified using the method described to give results traceable to the International System of Units (SI) with a total measurement uncertainty of <20%. Results compared favorably with an orthogonal traceable method using total tryptic digestion, peptide separation, and isotope dilution mass spectrometry.


Asunto(s)
Hormona de Crecimiento Humana/sangre , Espectrometría de Masas en Tándem/métodos , Secuencia de Aminoácidos , Cromatografía Liquida , Hormona de Crecimiento Humana/análisis , Humanos , Marcaje Isotópico , Isótopos/análisis , Isótopos/sangre , Límite de Detección , Datos de Secuencia Molecular , Proteínas Recombinantes/análisis , Proteínas Recombinantes/sangre , Estándares de Referencia , Espectrometría de Masas en Tándem/normas
17.
J AOAC Int ; 96(6): 1350-61, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24645514

RESUMEN

Current routine food allergen quantification methods, which are based on immunochemistry, offer high sensitivity but can suffer from issues of specificity and significant variability of results. MS approaches have been developed, but currently lack metrological traceability. A feasibility study on the application of metrologically traceable MS-based reference procedures was undertaken. A proof of concept involving proteolytic digestion and isotope dilution MS for quantification of protein allergens in a food matrix was undertaken using lysozyme in wine as a model system. A concentration of lysozyme in wine of 0.95 +/- 0.03 microg/g was calculated based on the concentrations of two peptides, confirming that this type of analysis is viable at allergenically meaningful concentrations. The challenges associated with this promising method were explored; these included peptide stability, chemical modification, enzymatic digestion, and sample cleanup. The method is suitable for the production of allergen in food certified reference materials, which together with the achieved understanding of the effects of sample preparation and of the matrix on the final results, will assist in addressing the bias of the techniques routinely used and improve measurement confidence. Confirmation of the feasibility of MS methods for absolute quantification of an allergenic protein in a food matrix with results traceable to the International System of Units is a step towards meaningful comparison of results for allergen proteins among laboratories. This approach will also underpin risk assessment and risk management of allergens in the food industry, and regulatory compliance of the use of thresholds or action levels when adopted.


Asunto(s)
Alérgenos/química , Contaminación de Alimentos/análisis , Muramidasa/química , Vino/análisis , Animales , Pollos , Enzimas/química , Análisis de los Alimentos/métodos , Hipersensibilidad a los Alimentos , Espectrometría de Masas/métodos , Muramidasa/análisis , Óvulo/química , Péptidos/química , Estándares de Referencia , Medición de Riesgo , Gestión de Riesgos , Tripsina/química
18.
Bioanalysis ; 3(24): 2797-802, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22185279

RESUMEN

To ensure comparability of results in clinical proteomics, methods for accurate and traceable quantification of proteins are required. Typically this is done for recombinant proteins using isotopically labeled peptides as internal standards (IS). However, in order to perform quantification in complex matrices such as human serum, isotopically labeled protein standards have been suggested for use as IS to account for losses in sample preparation. The isotopic diluent must be chemically and physically identical to the analyte of interest, having the same amino acid sequence, post-translational modifications, secondary and tertiary structure. It must not be assumed but rather proven that the isotopic diluent is a true mimic, and here we consider both the advantages and potential pitfalls encountered when using isotopically labeled protein IS.


Asunto(s)
Proteínas/análisis , Proteómica , Secuencia de Aminoácidos , Cromatografía Líquida de Alta Presión/normas , Hormona del Crecimiento/análisis , Hormona del Crecimiento/genética , Hormona del Crecimiento/metabolismo , Humanos , Marcaje Isotópico , Espectrometría de Masas/normas , Datos de Secuencia Molecular , Estructura Terciaria de Proteína , Proteínas/genética , Proteínas/metabolismo , Proteómica/normas , Proteínas Recombinantes/genética , Proteínas Recombinantes/metabolismo , Proteínas Recombinantes/normas , Estándares de Referencia
19.
Anal Biochem ; 412(1): 40-6, 2011 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-21185255

RESUMEN

Over the past decade, a number of endogenous peptides and endogenous peptide analogs have been employed in therapeutics and as diagnostic markers. The use of peptides as standards for the absolute quantification of proteins has become commonly accepted. Consequently, the requirement for standard peptides traceable to the International System of Units with low associated measurement uncertainty, and for accurate methods of peptide quantification, has increased. Here we describe a method of peptide quantification involving microwave-assisted acid hydrolysis followed by gas chromatography-mass spectrometry that enables traceable quantification of a peptide by exact matching isotope dilution mass spectrometry where the total hydrolysis time required is only 3h. A solution of angiotensin I was quantified using this method, and the results were in agreement with those obtained previously using an oven hydrolysis liquid chromatography-tandem mass spectrometry method.


Asunto(s)
Cromatografía de Gases y Espectrometría de Masas/métodos , Microondas , Péptidos/análisis , Péptidos/normas , Secuencia de Aminoácidos , Aminoácidos/química , Aminoácidos/normas , Angiotensina I/análisis , Cromatografía de Gases y Espectrometría de Masas/normas , Hidrólisis , Datos de Secuencia Molecular , Temperatura , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...