Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Med Imaging (Bellingham) ; 5(1): 013503, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29430473

RESUMEN

Two dosimetric quantities [mean glandular dose (MGD) and entrance surface air kerma (ESAK)] and the diagnostic performance of phase-contrast mammography with synchrotron radiation (MSR) are compared to conventional digital mammography (DM). Seventy-one patients (age range, 41 to 82 years) underwent MSR after a DM examination if questionable or suspicious breast abnormalities were not clarified by ultrasonography. The MGD and the ESAK delivered in both examinations were evaluated and compared. Two on-site radiologists rated the images in consensus according to the Breast Imaging Reporting and Data System assessment categories, which were then correlated with the final diagnoses by means of statistical generalized linear models (GLMs). Receiver operating characteristic curves were also used to assess the diagnostic performance by comparing the area under the curve (AUC). An important MGD and ESAK reduction was observed in MSR due to the monoenergetic beam. In particular, an average 43% reduction was observed for the MGD and a reduction of more than 50% for the ESAK. GLM showed higher diagnostic accuracy, especially in terms of specificity, for MSR, confirmed by AUC analysis ([Formula: see text]). The study design implied that the population was characterized by a high prevalence of disease and that the radiologists, who read the DM images before referring the patient to MSR, could have been influenced in their assessments. Within these limitations, the use of synchrotron radiation with the phase-contrast technique applied to mammography showed an important dose reduction and a higher diagnostic accuracy compared with DM. These results could further encourage research on the translation of x-ray phase-contrast imaging into the clinics.

2.
Philos Trans A Math Phys Eng Sci ; 372(2010): 20130025, 2014 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-24470410

RESUMEN

The first clinical study of phase-contrast mammography (PCM) with synchrotron radiation was carried out at the Synchrotron Radiation for Medical Physics beamline of the Elettra synchrotron radiation facility in Trieste (Italy) in 2006-2009. The study involved 71 patients with unresolved breast abnormalities after conventional digital mammography and ultrasonography exams carried out at the Radiology Department of Trieste University Hospital. These cases were referred for mammography at the synchrotron radiation facility, with images acquired using a propagation-based phase-contrast imaging technique. To investigate the contribution of phase-contrast effects to the image quality, two experienced radiologists specialized in mammography assessed the visibility of breast abnormalities and of breast glandular structures. The images acquired at the hospital and at the synchrotron radiation facility were compared and graded according to a relative seven-grade visual scoring system. The statistical analysis highlighted that PCM with synchrotron radiation depicts normal structures and abnormal findings with higher image quality with respect to conventional digital mammography.


Asunto(s)
Mamografía/métodos , Mama/citología , Humanos , Mamografía/instrumentación , Control de Calidad , Sensibilidad y Especificidad
3.
Radiology ; 259(3): 684-94, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21436089

RESUMEN

PURPOSE: To prospectively evaluate the diagnostic contribution of mammography with synchrotron radiation in patients with questionable or suspicious breast abnormalities identified at combined digital mammography (DM) and ultrasonography (US). MATERIALS AND METHODS: The ethics committee approved this prospective study, and written informed consent was obtained from all patients. Mammography with synchrotron radiation was performed with a phase-detection technique at a synchrotron radiation laboratory. Forty-nine women who met at least one of the inclusion criteria (palpable mass, focal asymmetry, architectural distortion, or equivocal or suspicious mass at DM; none clarified at US) were enrolled. Forty-seven women (mean age, 57.8 years ± 8.8 [standard deviation]; age range, 43-78 years) completed the study protocol, which involved biopsy or follow-up for 1 year as the reference standard. Breast Imaging Reporting and Data System (BI-RADS) scores of 1-3 were considered to indicate a negative result, while scores 4-5 were considered to indicate a positive result. The visibility of breast abnormalities and the glandular parenchymal structure at DM and at mammography with synchrotron radiation was compared by using the Wilcoxon signed rank test. RESULTS: In 29 of the 31 patients with a final diagnosis of benign entity, mammography with synchrotron radiation yielded BI-RADS scores of 1-3. In 13 of the remaining 16 patients with a final diagnosis of malignancy, mammography with synchrotron radiation yielded BI-RADS scores of 4-5. Therefore, a sensitivity of 81% (13 of 16 patients) and a specificity of 94% (29 of 31 patients) were achieved with use of the described BI-RADS dichotomization system. CONCLUSION: These study results suggest that mammography with synchrotron radiation can be used to clarify cases of questionable or suspicious breast abnormalities identified at DM. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11100745/-/DC1.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mamografía/métodos , Sincrotrones , Adulto , Anciano , Biopsia , Femenino , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Dosis de Radiación , Sensibilidad y Especificidad , Estadísticas no Paramétricas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...