Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Hum Vaccin Immunother ; 17(7): 1980-1985, 2021 07 03.
Artículo en Inglés | MEDLINE | ID: mdl-33844623

RESUMEN

This open-label, single-center, Phase 3 study (NCT03546842) assessed the immunogenicity and safety of the nine-valent human papillomavirus (9vHPV; HPV6/11/16/18/31/33/45/52/58) vaccine in Vietnamese males and females, with the aim to support 9vHPV vaccine licensure in Vietnam. Participants aged 9-26 years received three 9vHPV vaccine doses (Day 1, Month 2, Month 6). Serum samples were obtained on Day 1 (pre-vaccination) and at Month 7 (one month post-Dose 3) for the measurement of anti-HPV antibodies. Geometric mean titers (GMTs) and seroconversion percentages were obtained using the HPV-9 competitive Luminex immunoassay. Injection-site adverse events (AEs), systemic AEs, serious AEs (SAEs), and study discontinuations due to AEs were recorded. Of 201 participants enrolled, 200 (99.5%) received ≥1 vaccine dose. All participants who received the three-dose regimen (198/200, 98.5%) seroconverted for all 9vHPV vaccine types by Month 7. Robust anti-HPV GMT responses were also observed. Half of participants (50.5%) reported ≥1 AE; the majority were injection-site-related (45.0%) and mild (43.0%). There were no deaths, vaccine-related SAEs, or discontinuations due to AEs. Administration of three 9vHPV vaccine doses was highly immunogenic and resulted in acceptable seropositivity percentages for all vaccine HPV types. The 9vHPV vaccine was generally well tolerated among this study population.Region of origin: VietnamTrial registration: clinicaltrials.gov Identifier NCT03546842.


Asunto(s)
Infecciones por Papillomavirus , Vacunas contra Papillomavirus , Adolescente , Adulto , Anticuerpos Antivirales , Pueblo Asiatico , Niño , Femenino , Humanos , Inmunogenicidad Vacunal , Masculino , Papillomaviridae , Infecciones por Papillomavirus/prevención & control , Vacunas contra Papillomavirus/efectos adversos , Vietnam/epidemiología , Adulto Joven
2.
Hum Vaccin Immunother ; 17(3): 690-693, 2021 03 04.
Artículo en Inglés | MEDLINE | ID: mdl-32783746

RESUMEN

Quadrivalent influenza vaccines (QIVs) provide protection against the two influenza A viruses (H1N1 and H3N2) and both co-circulating influenza B lineages. QIVs have been found safe, immunogenic, and efficacious in several phase III clinical trials. Here we assess the safety of QIV after vaccination in Vietnamese infants, children, and adults. Participants (n = 228) were asked to report any solicited adverse events (AEs) occurring within 7 days, unsolicited non-serious AEs occurring within 28 days post-vaccination, and serious adverse events (SAEs) at any time during the study. The study was completed by 224 participants (97.4%). Thirty-one children (39.7%) aged 6 - 35 months, 32 children (40.0%) aged 3 - 8 years, 2 participants (9.0%) aged 9 - 17 years, 5 participants (17.9%) aged 18 - 60 years, and 3 participants (15.0%) aged ≥60 years reported ≥1 solicited reaction within 7 days following vaccination. The most frequent-solicited AEs were injection-site tenderness or pain, appetite loss, fever, and abnormal crying in 6 - 35 month-olds, and fever, headache, and myalgia in other age groups. No severe-unsolicited AEs or vaccine-related SAEs were reported. These results suggest that QIV is well tolerated across age groups in Vietnam, and can be safely used to protect the Vietnamese population against influenza and its potentially serious complications.


Asunto(s)
Subtipo H1N1 del Virus de la Influenza A , Vacunas contra la Influenza , Gripe Humana , Adulto , Anticuerpos Antivirales , Pueblo Asiatico , Niño , Voluntarios Sanos , Pruebas de Inhibición de Hemaglutinación , Humanos , Lactante , Subtipo H3N2 del Virus de la Influenza A , Vacunas contra la Influenza/efectos adversos , Gripe Humana/prevención & control , Vacunas de Productos Inactivados , Vietnam/epidemiología
3.
BMC Infect Dis ; 15: 70, 2015 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-25888462

RESUMEN

BACKGROUND: The GeneXpertMTB/RIF (Xpert) assay is now recommended by WHO for diagnosis of tuberculosis (TB) in children but evaluation data is limited. METHODS: One hundred and fifty consecutive HIV negative children (<15 years of age) presenting with suspected TB were enrolled at a TB referral hospital in Ho Chi Minh City, Vietnam. 302 samples including sputum (n = 79), gastric fluid (n = 215), CSF (n = 3), pleural fluid (n = 4) and cervical lymphadenopathic pus (n = 1) were tested by smear, automated liquid culture (Bactec MGIT) and Xpert. Patients were classified retrospectively using the standardised case definition into confirmed, probable, possible, TB unlikely or not TB categories. Test accuracy was evaluated against 2 gold standards: [1] clinical (confirmed, probable and possible TB) and [2] 'confirmed TB' alone. RESULTS: The median age of participants was 18 months [IQR 5-170]. When test results were aggregated by patient, the sensitivity of smear, Xpert and MGIT against clinical diagnosis as the gold standard were 9.2% (n = 12/131) [95%CI 4.2; 14.1], 20.6% (n = 27/131) [95%CI 13.7; 27.5] and 29.0% (n = 38/131) [21.2;36.8], respectively. Specificity 100% (n = 19/19), 94.7% (n = 18/19), 94.7% (n = 18/19), respectively. Xpert was more sensitive than smear (P = <0.001) and less sensitive than MGIT (P = 0.002). CONCLUSIONS: The systematic use of Xpert will increase early TB case confirmation in children and represents a major advance but sensitivity of all tests remains unacceptably low. Improved rapid diagnostic tests and algorithm approaches for pediatric TB are still an urgent research priority.


Asunto(s)
Mycobacterium tuberculosis/aislamiento & purificación , Tuberculosis/diagnóstico , Adolescente , Algoritmos , Niño , Preescolar , ADN Bacteriano/análisis , Femenino , Infecciones por VIH/diagnóstico , Humanos , Lactante , Masculino , Mycobacterium tuberculosis/genética , Estudios Prospectivos , Sensibilidad y Especificidad , Esputo/microbiología , Vietnam
4.
BMC Infect Dis ; 13: 31, 2013 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-23343418

RESUMEN

BACKGROUND: Tuberculosis (TB) in children is rarely confirmed due to the lack of effective diagnostic tools; only 10 to 15% of pediatric TB is smear positive due to paucibacillary samples and the difficulty of obtaining high-quality specimens from children. We evaluate here the accuracy of Xpert MTB/RIF in comparison with the Micoroscopic observation drug susceptibility (MODS) assay for diagnosis of TB in children using samples stored during a previously reported evaluation of the MODS assay. METHODS: Ninety-six eligible children presenting with suspected TB were recruited consecutively at Pham Ngoc Thach Hospital in Ho Chi Minh City Viet Nam between May to December 2008 and tested by Ziehl-Neelsen smear, MODS and Mycobacterial growth Indicator (MGIT, Becton Dickinson) culture. All samples sent by the treating clinician for testing were included in the analysis. An aliquot of processed sample deposit was stored at -20°C and tested in the present study by Xpert MTB/RIF test. 183 samples from 73 children were available for analysis by Xpert. Accuracy measures of MODS and Xpert were summarized. RESULTS: The sensitivity (%) in detecting children with a clinical diagnosis of TB for smear, MODS and Xpert were 37.9 [95% CI 25.5; 51.6], 51.7 [38.2; 65.0] and 50.0 [36.6; 63.4], respectively (per patient analysis). Xpert was significantly more sensitive than smear (P=0.046). Testing of additional samples did not increase case detection for MODS while testing of a second sputum sample by Xpert detected only two additional cases. The positive and negative predictive values (%) of Xpert were 100.0 [88.0; 100.0] and 34.1 [20.5; 49.9], respectively, while those of MODS were 96.8 [83.3; 99.9] and 33.3 [19.6; 49.5]. CONCLUSION: MODS culture and Xpert MTB/RIF test have similar sensitivities for the detection of pediatric TB. Xpert MTB RIF is able to detect tuberculosis and rifampicin resistance within two hours. MODS allows isolation of cultures for further drug susceptibility testing but requires approximately one week to become positive. Testing of multiple samples by xpert detected only two additional cases and the benefits must be considered against costs in each setting. Further research is required to evaluate the optimal integration of Xpert into pediatric testing algorithms.


Asunto(s)
Técnicas Bacteriológicas/métodos , Pruebas de Sensibilidad Microbiana , Mycobacterium tuberculosis , Juego de Reactivos para Diagnóstico , Tuberculosis/diagnóstico , Adolescente , Niño , Preescolar , Farmacorresistencia Bacteriana , Humanos , Lactante , Recién Nacido , Mycobacterium tuberculosis/efectos de los fármacos , Mycobacterium tuberculosis/aislamiento & purificación , Reproducibilidad de los Resultados , Rifampin/farmacología , Sensibilidad y Especificidad
5.
PLoS One ; 4(12): e8341, 2009 Dec 17.
Artículo en Inglés | MEDLINE | ID: mdl-20020056

RESUMEN

MODS is a novel liquid culture based technique that has been shown to be effective and rapid for early diagnosis of tuberculosis (TB). We evaluated the MODS assay for diagnosis of TB in children in Viet Nam. 217 consecutive samples including sputum (n = 132), gastric fluid (n = 50), CSF (n = 32) and pleural fluid (n = 3) collected from 96 children with suspected TB, were tested by smear, MODS and MGIT. When test results were aggregated by patient, the sensitivity and specificity of smear, MGIT and MODS against "clinical diagnosis" (confirmed and probable groups) as the gold standard were 28.2% and 100%, 42.3% and 100%, 39.7% and 94.4%, respectively. The sensitivity of MGIT and MODS was not significantly different in this analysis (P = 0.5), but MGIT was more sensitive than MODS when analysed on the sample level using a marginal model (P = 0.03). The median time to detection of MODS and MGIT were 8 days and 13 days, respectively, and the time to detection was significantly shorter for MODS in samples where both tests were positive (P<0.001). An analysis of time-dependent sensitivity showed that the detection rates were significantly higher for MODS than for MGIT by day 7 or day 14 (P<0.001 and P = 0.04), respectively. MODS is a rapid and sensitive alternative method for the isolation of M.tuberculosis from children.


Asunto(s)
Pruebas Diagnósticas de Rutina/métodos , Diagnóstico Precoz , Tuberculosis Pulmonar/diagnóstico , Adolescente , Técnicas de Tipificación Bacteriana , Niño , Preescolar , Demografía , Femenino , Humanos , Masculino , Pruebas de Sensibilidad Microbiana , Mycobacterium tuberculosis/clasificación , Mycobacterium tuberculosis/aislamiento & purificación , Estándares de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Factores de Tiempo , Resultado del Tratamiento , Tuberculosis Pulmonar/líquido cefalorraquídeo , Tuberculosis Pulmonar/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...