Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Skeletal Radiol ; 53(5): 899-908, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37945769

RESUMEN

OBJECTIVE: Determine the utility of ZTE as an adjunct to routine MR for assessing degenerative disease in the cervical spine. METHODS: Retrospective study on 42 patients with cervical MR performed with ZTE from 1/1/2022 to 4/30/22. Fellowship trained radiologists evaluated each cervical disc level for neural foraminal (NF) narrowing, canal stenosis (CS), facet arthritis (FA), and presence of ossification of the posterior longitudinal ligament (OPLL). When NF narrowing and CS were present, the relative contributions of bone and soft disc were determined and a confidence level for doing so was assigned. Comparisons were made between assessments on routine MR without and with ZTE. RESULTS: With ZTE added, bone contribution as a cause of NF narrowing increased in 47% (n = 110) of neural foramina and decreased in 12% (n = 29) (p = < 0.001). Bone contribution as a cause of CS increased in 25% (n = 33) of disc levels and decreased in 10% (n = 13) (p = 0.013). Confidence increased in identifying the cause of NF narrowing (p = < 0.001)) and CS (p = 0.009) with ZTE. The cause of NF narrowing (p = 0.007) and CS (p = 0.041) changed more frequently after ZTE was added when initial confidence in making the determination was low. There was no change in detection of FA or presence of OPLL with ZTE. CONCLUSION: Addition of ZTE to a routine cervical spine MR changes the assessment of the degree of bone involvement in degenerative cervical spine pathology.


Asunto(s)
Vértebras Cervicales , Imagen por Resonancia Magnética , Humanos , Estudios Retrospectivos , Vértebras Cervicales/patología , Cuello
2.
J Comput Assist Tomogr ; 48(1): 150-155, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37551157

RESUMEN

OBJECTIVE: Imaging is crucial in the assessment of head and neck cancers for site, extension, and enlarged lymph nodes. Restriction spectrum imaging (RSI) is a new diffusion-weighted magnetic resonance imaging (MRI) technique that enhances the ability to differentiate aggressive cancer from low-grade or benign tumors and helps guide treatment and biopsy. Its contribution to imaging of brain and prostate tumors has been previously published. However, there are no prior studies using RSI sequence in head and neck tumors. The purpose of this study was to evaluate the feasibility of performing RSI in head and neck cancer. METHODS: An additional RSI sequence was added in the routine MRI neck protocol for 13 patients diagnosed with head and neck cancer between November 2018 and April 2019. Restriction spectrum imaging sequence was performed with b values of 0, 500, 1500, and 3000 s/mm 2 and 29 directions on 1.5T magnetic resonance scanners.Diffusion-weighted imaging (DWI) images and RSI images were compared according to their ability to detect the primary malignancy and possible metastatic lymph nodes. RESULTS: In 71% of the patients, RSI outperformed DWI in detecting the primary malignancy and possible metastatic lymph nodes, whereas in the remaining cases, the 2 were comparable. In 66% of the patients, RSI detected malignant lymph nodes that DWI/apparent diffusion coefficient failed to detect. CONCLUSIONS: This is the first study of RSI in head and neck imaging and showed its superiority over the conventional DWI sequence. Because of its ability to differentiate benign and malignant lymph nodes in some cases, the addition of RSI to routine head and neck MRI should be considered.


Asunto(s)
Neoplasias de Cabeza y Cuello , Masculino , Humanos , Proyectos Piloto , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Ganglios Linfáticos/patología , Cuello/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética/métodos , Sensibilidad y Especificidad
3.
Acta Radiol ; 65(4): 350-358, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38130123

RESUMEN

BACKGROUND: UTE T2* cartilage mapping use in patients undergoing femoroacetabular impingement (FAI) has been lacking but may allow the detection of early cartilage damage. PURPOSE: To assess the reproducibility of UTE T2* cartilage mapping and determine the difference in UTE T2* values between FAI and asymptomatic patients and to evaluate the correlation between UTE T2* values and patient-reported symptoms. MATERIAL AND METHODS: Prospective evaluation of both hips (7 FAI and 7 asymptomatic patients). Bilateral hip 3-T MRI scans with UTE T2* cartilage maps were acquired. A second MRI scan was acquired 1-9 months later. Cartilage was segmented into anterosuperior, superior, and posterosuperior regions. Assessment was made of UTE T2* reproducibility (ICC). Mean UTE T2* values in patients were compared (t-tests) and correlation was made with patient-reported outcomes (Spearman's). RESULTS: ICCs of mean UTE T2* were as follows: acetabular, 0.82 (95% CI=0.50-0.95); femoral, 0.76 (95% CI=0.35-0.92). Significant strong correlation was found between mean acetabular UTE T2* values and iHOT12 (ρ = -0.63) and moderate correlation with mHHS (ρ = -0.57). There was no difference in mean UTE T2* values between affected vs. non-affected FAI hips. FAI-affected hips had significantly higher values in acetabulum vs. asymptomatic patients (13.47 vs. 12.55 ms). There was no difference in mean femoral cartilage values between the FAI-affected hips vs. asymptomatic patients. The posterosuperior femoral region had a higher mean value in non-affected FAI hips vs. asymptomatic patients (12.60 vs. 11.53 ms). CONCLUSION: UTE T2* cartilage mapping had excellent reproducibility. Affected FAI hips had higher mean acetabular UTE T2* values than asymptomatic patients. Severity of patient-reported symptoms correlates with UTE T2* acetabular cartilage values.


Asunto(s)
Cartílago Articular , Pinzamiento Femoroacetabular , Imagen por Resonancia Magnética , Humanos , Pinzamiento Femoroacetabular/diagnóstico por imagen , Femenino , Masculino , Proyectos Piloto , Cartílago Articular/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Adulto , Estudios Prospectivos , Reproducibilidad de los Resultados , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/patología , Adulto Joven , Persona de Mediana Edad
4.
Front Neuroimaging ; 2: 1072759, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37554641

RESUMEN

Magnetic Resonance Imaging (MR Imaging) is routinely employed in diagnosing Alzheimer's Disease (AD), which accounts for up to 60-80% of dementia cases. However, it is time-consuming, and protocol optimization to accelerate MR Imaging requires local expertise since each pulse sequence involves multiple configurable parameters that need optimization for contrast, acquisition time, and signal-to-noise ratio (SNR). The lack of this expertise contributes to the highly inefficient utilization of MRI services diminishing their clinical value. In this work, we extend our previous effort and demonstrate accelerated MRI via intelligent protocolling of the modified brain screen protocol, referred to as the Gold Standard (GS) protocol. We leverage deep learning-based contrast-specific image-denoising to improve the image quality of data acquired using the accelerated protocol. Since the SNR of MR acquisitions depends on the volume of the object being imaged, we demonstrate subject-specific (SS) image-denoising. The accelerated protocol resulted in a 1.94 × gain in imaging throughput. This translated to a 72.51% increase in MR Value-defined in this work as the ratio of the sum of median object-masked local SNR values across all contrasts to the protocol's acquisition duration. We also computed PSNR, local SNR, MS-SSIM, and variance of the Laplacian values for image quality evaluation on 25 retrospective datasets. The minimum/maximum PSNR gains (measured in dB) were 1.18/11.68 and 1.04/13.15, from the baseline and SS image-denoising models, respectively. MS-SSIM gains were: 0.003/0.065 and 0.01/0.066; variance of the Laplacian (lower is better): 0.104/-0.135 and 0.13/-0.143. The GS protocol constitutes 44.44% of the comprehensive AD imaging protocol defined by the European Prevention of Alzheimer's Disease project. Therefore, we also demonstrate the potential for AD-imaging via automated volumetry of relevant brain anatomies. We performed statistical analysis on these volumetric measurements of the hippocampus and amygdala from the GS and accelerated protocols, and found that 27 locations were in excellent agreement. In conclusion, accelerated brain imaging with the potential for AD imaging was demonstrated, and image quality was recovered post-acquisition using DL-based image denoising models.

5.
Adv Mater ; 35(31): e2300391, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37207689

RESUMEN

The quantum anomalous Hall (QAH) effect is characterized by a dissipationless chiral edge state with a quantized Hall resistance at zero magnetic field. Manipulating the QAH state is of great importance in both the understanding of topological quantum physics and the implementation of dissipationless electronics. Here, the QAH effect is realized in the magnetic topological insulator Cr-doped (Bi,Sb)2 Te3 (CBST) grown on an uncompensated antiferromagnetic insulator Al-doped Cr2 O3 . Through polarized neutron reflectometry (PNR), a strong exchange coupling is found between CBST and Al-Cr2 O3 surface spins fixing interfacial magnetic moments perpendicular to the film plane. The interfacial coupling results in an exchange-biased QAH effect. This study further demonstrates that the magnitude and sign of the exchange bias can be effectively controlled using a field training process to set the magnetization of the Al-Cr2 O3 layer. It demonstrates the use of the exchange bias effect to effectively manipulate the QAH state, opening new possibilities in QAH-based spintronics.

6.
ACS Nano ; 17(7): 6745-6753, 2023 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-36995303

RESUMEN

Electric field control of the exchange bias effect across ferromagnet/antiferromagnet (FM/AF) interfaces has offered exciting potentials for low-energy-dissipation spintronics. In particular, the solid-state magneto-ionic means is highly appealing as it may allow reconfigurable electronics by transforming the all-important FM/AF interfaces through ionic migration. In this work, we demonstrate an approach that combines the chemically induced magneto-ionic effect with the electric field driving of nitrogen in the Ta/Co0.7Fe0.3/MnN/Ta structure to electrically manipulate exchange bias. Upon field-cooling the heterostructure, ionic diffusion of nitrogen from MnN into the Ta layers occurs. A significant exchange bias of 618 Oe at 300 K and 1484 Oe at 10 K is observed, which can be further enhanced after a voltage conditioning by 5 and 19%, respectively. This enhancement can be reversed by voltage conditioning with an opposite polarity. Nitrogen migration within the MnN layer and into the Ta capping layer cause the enhancement in exchange bias, which is observed in polarized neutron reflectometry studies. These results demonstrate an effective nitrogen-ion based magneto-ionic manipulation of exchange bias in solid-state devices.

7.
Magn Reson Imaging ; 99: 81-90, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36764630

RESUMEN

Neuroimaging of certain pathologies requires both multi-parametric qualitative and quantitative imaging. The role of the quantitative MRI (qMRI) is well accepted but suffers from long acquisition times leading to patient discomfort, especially in geriatric and pediatric patients. Previous studies show that synthetic MRI can be used in order to reduce the scan time and provide qMRI as well as multi-contrast data. However, this approach suffers from artifacts such as partial volume and flow. In order to increase the scan efficiency (the number of contrasts and quantitative maps acquired per unit time), we designed, simulated, and demonstrated rapid, simultaneous, multi-contrast qualitative (T1 weighted, T1 fluid attenuated inversion recovery (FLAIR), T2 weighted, water, and fat), and quantitative imaging (T1 and T2 maps) through the approach of tailored MR fingerprinting (TMRF) to cover whole-brain in approximately four minutes. We performed TMRF on in vivo four healthy human brains and in vitro ISMRM/NIST phantom and compared with vendor supplied gold standard (GS) and MRF sequences. All scans were performed on a 3 T GE Premier system and images were reconstructed offline using MATLAB. The reconstructed qualitative images were then subjected to custom DL denoising and gradient anisotropic diffusion denoising. The quantitative tissue parametric maps were reconstructed using a dense neural network to gain computational speed compared to dictionary matching. The grey matter and white matter tissues in qualitative and quantitative data for the in vivo datasets were segmented semi-automatically. The SNR and mean contrasts were plotted and compared across all three methods. The GS images show better SNR in all four subjects compared to MRF and TMRF (GS > TMRF>MRF). The T1 and T2 values of MRF are relatively overestimated as compared to GS and TMRF. The scan efficiency for TMRF is 1.72 min-1 which is higher compared to GS (0.32 min-1) and MRF (0.90 min-1).


Asunto(s)
Encéfalo , Imagen por Resonancia Magnética , Humanos , Niño , Anciano , Imagen por Resonancia Magnética/métodos , Neuroimagen , Fantasmas de Imagen , Espectroscopía de Resonancia Magnética , Procesamiento de Imagen Asistido por Computador/métodos
8.
Nat Commun ; 13(1): 7774, 2022 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-36522321

RESUMEN

Cobalt oxides have long been understood to display intriguing phenomena known as spin-state crossovers, where the cobalt ion spin changes vs. temperature, pressure, etc. A very different situation was recently uncovered in praseodymium-containing cobalt oxides, where a first-order coupled spin-state/structural/metal-insulator transition occurs, driven by a remarkable praseodymium valence transition. Such valence transitions, particularly when triggering spin-state and metal-insulator transitions, offer highly appealing functionality, but have thus far been confined to cryogenic temperatures in bulk materials (e.g., 90 K in Pr1-xCaxCoO3). Here, we show that in thin films of the complex perovskite (Pr1-yYy)1-xCaxCoO3-δ, heteroepitaxial strain tuning enables stabilization of valence-driven spin-state/structural/metal-insulator transitions to at least 291 K, i.e., around room temperature. The technological implications of this result are accompanied by fundamental prospects, as complete strain control of the electronic ground state is demonstrated, from ferromagnetic metal under tension to nonmagnetic insulator under compression, thereby exposing a potential novel quantum critical point.

10.
Artículo en Inglés | MEDLINE | ID: mdl-35848081

RESUMEN

Advances in the synthesis and characterization of colloidal magnetic nanoparticles (NPs) have yielded great gains in the understanding of their complex magnetic behavior, with implications for numerous applications. Recent work using Ni NPs as a model soft ferromagnetic system, for example, achieved quantitative understanding of the superparamagnetic blocking temperature-particle diameter relationship. This hinged, however, on the critical assumption of a ferromagnetic NP volume lower than the chemical volume due to a non-ferromagnetic dead shell indirectly deduced from magnetometry. Here, we determine both the chemical and magnetic average internal structures of Ni NP ensembles via unpolarized, half-polarized, and fully polarized small-angle neutron scattering (SANS) measurements and analyses coupled with X-ray diffraction and magnetometry. The postulated nanometric magnetic dead shell is not only detected but conclusively identified as a non-ferromagnetic Ni phosphide derived from the trioctylphosphine commonly used in hot-injection colloidal NP syntheses. The phosphide shell thickness is tunable via synthesis temperature, falling to as little as 0.5 nm at 170 °C. Temperature- and magnetic field-dependent polarized SANS measurements additionally reveal essentially bulk-like ferromagnetism in the Ni core and negligible interparticle magnetic interactions, quantitatively supporting prior modeling of superparamagnetism. These findings advance the understanding of synthesis-structure-property relationships in metallic magnetic NPs, point to a simple potential route to ligand-free stabilization, and highlight the power of the currently available suite of polarized SANS measurement and analysis capabilities for magnetic NP science and technology.

11.
Nano Lett ; 22(14): 5735-5741, 2022 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-35850534

RESUMEN

Topological surface states are a new class of electronic states with novel properties, including the potential for annihilation between surface states from two topological insulators at a common interface. Here, we report the annihilation and creation of topological surface states in the SnTe/Crx(BiSb)2-xTe3 (CBST) heterostructures as evidenced by magneto-transport, polarized neutron reflectometry, and first-principles calculations. Our results show that topological surface states are induced in the otherwise topologically trivial two-quintuple-layers thick CBST when interfaced with SnTe, as a result of the surface state annihilation at the SnTe/CBST interface. Moreover, we unveiled systematic changes in the transport behaviors of the heterostructures with respect to changing Fermi level and thickness. Our observation of surface state creation and annihilation demonstrates a promising way of designing and engineering topological surface states for dissipationless electronics.

12.
ACS Nano ; 16(5): 7580-7588, 2022 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-35446560

RESUMEN

The combination of small coercive fields and weak magnetic anisotropy makes soft ferromagnetic films extremely useful for nanoscale devices that need to easily switch spin directions. However, soft ferromagnets are relatively rare, particularly in ultrathin films with thicknesses of a few nanometers or less. We have synthesized large-area, high-quality, ultrathin freestanding LaMnO3 films on Si and found unexpected soft ferromagnetism along both the in-plane and out-of-plane directions when the film thickness was reduced to 4 nm. We argue that the vanishing magnetic anisotropy between the two directions is a consequence of two coexisting magnetic easy axes in different atomic layers of the LaMnO3 film. Spectroscopy measurements reveal a change in Mn valence from 3+ in the film interior to approximately 2+ at the surfaces where considerable hydrogen infiltration occurs due to the water dissolving process. First-principles calculations show that protonation of LaMnO3 decreases the Mn valence and switches the magnetic easy axis from in-plane to out-of-plane as the Mn valence approaches 2+ from its 3+ bulk value. Our work demonstrates that ultrathin freestanding films can exhibit functional properties that are absent in homogeneous materials, concomitant with their convenient compatibility with Si-based devices.

13.
Acta Radiol ; 63(6): 760-766, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33926266

RESUMEN

BACKGROUND: Ultrashort echo time (UTE) T2* is sensitive to molecular changes within the deep calcified layer of cartilage. Feasibility of its use in the hip needs to be established to determine suitability for clinical use. PURPOSE: To establish feasibility of UTE T2* cartilage mapping in the hip and determine if differences in regional values exist. MATERIAL AND METHODS: MRI scans with UTE T2* cartilage maps were prospectively acquired on eight hips. Hip cartilage was segmented into whole and deep layers in anterosuperior, superior, and posterosuperior regions. Quantitative UTE T2* maps were analyzed (independent one-way ANOVA) and reliability was calculated (ICC). RESULTS: UTE T2* mean values (anterosuperior, superior, posterosuperior): full femoral layer (19.55, 18.43, 16.84 ms) (P=0.004), full acetabular layer (19.37, 17.50, 16.73 ms) (P=0.013), deep femoral layer (18.68, 17.90, 15.74 ms) (P=0.010), and deep acetabular layer (17.81, 16.18, 15.31 ms) (P=0.007). Values were higher in anterosuperior compared to posterosuperior regions (mean difference; 95% confidence interval [CI]): full femur layer (2.71 ms; 95% CI 0.91-4.51: P=0.003), deep femur layer (2.94 ms; 95% CI 0.69-5.19; P=0.009), full acetabular layer (2.63 ms 95% CI 0.55-4.72; P=0.012), and deep acetabular layer (2.50 ms; 95% CI 0.69-4.30; P=0.006). Intra-reader (ICC 0.89-0.99) and inter-reader reliability (ICC 0.63-0.96) were good to excellent for the majority of cartilage layers. CONCLUSION: UTE T2* cartilage mapping was feasible in the hip with mean values in the range of 16.84-19.55 ms in the femur and 16.73-19.37 ms in the acetabulum. Significantly higher values were present in the anterosuperior region compared to the posterosuperior region.


Asunto(s)
Cartílago Articular , Cartílago Articular/diagnóstico por imagen , Estudios de Factibilidad , Fémur , Humanos , Imagen por Resonancia Magnética , Proyectos Piloto , Reproducibilidad de los Resultados
14.
J Comput Assist Tomogr ; 45(5): 717-721, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34347705

RESUMEN

PURPOSE: Assess feasibility of ultrashort echo time (UTE) T2* cartilage mapping in sacroiliac (SI) joints. METHODS: Prospective magnetic resonance imagings with UTE T2* cartilage maps obtained on 20 SI joints in 10 subjects. Each joint was segmented into thirds by 2 radiologists. The UTE T2* maps were analyzed; reliability and differences in UTE T2* values between radiologists were assessed. RESULTS: Mean UTE T2* value was 10.44 ± 0.60 ms. No difference between right/left SI joints (median, 10.52 vs 10.45 ms; P = 0.940), men/women (median, 10.34 vs. 10.57 ms; P = 0.174), or different anatomic regions (median range 10.55-10.69 ms; P = 0.805). Intraclass correlation coefficients were 0.94 to 0.99 (intraobserver) and 0.91 to 0.96 (interobserver). Mean bias ± standard deviation on Bland-Altman was -0.137 ± 0.196 ms (limits of agreement -0.521 and 0.247) without proportional bias (ß = 0.148, P = 0.534). CONCLUSIONS: The UTE T2* cartilage mapping in the SI joints is feasible with high reader reliability.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Articulación Sacroiliaca/anatomía & histología , Adulto , Estudios de Factibilidad , Femenino , Humanos , Masculino , Proyectos Piloto , Estudios Prospectivos , Valores de Referencia , Reproducibilidad de los Resultados
15.
Adv Mater ; 33(22): e2008555, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33899284

RESUMEN

While being electrically insulating, magnetic insulators can behave as good spin conductors by carrying spin current with excited spin waves. So far, magnetic insulators are utilized in multilayer heterostructures for optimizing spin transport or to form magnon spin valves for reaching controls over the spin flow. In these studies, it remains an intensively visited topic as to what the corresponding roles of coherent and incoherent magnons are in the spin transmission. Meanwhile, understanding the underlying mechanism associated with spin transmission in insulators can help to identify new mechanisms that can further improve the spin transport efficiency. Here, by studying spin transport in a magnetic-metal/magnetic-insulator/platinum multilayer, it is demonstrated that coherent magnons can transfer spins efficiently above the magnon bandgap of magnetic insulators. Particularly the standing spin-wave mode can greatly enhance the spin flow by inducing a resonant magnon transmission. Furthermore, within the magnon bandgap, a shutdown of spin transmission due to the blocking of coherent magnons is observed. The demonstrated magnon transmission enhancement and filtering effect provides an efficient method for modulating spin current in magnonic devices.

16.
Int J MS Care ; 22(5): 226-232, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33177959

RESUMEN

Standardized magnetic resonance imaging (MRI) protocols are important for the diagnosis and monitoring of patients with multiple sclerosis (MS). The Consortium of Multiple Sclerosis Centers (CMSC) convened an international panel of MRI experts to review and update the current guidelines. The objective was to update the standardized MRI protocol and clinical guidelines for diagnosis and follow-up of MS and develop strategies for advocacy, dissemination, and implementation. Conference attendees included neurologists, radiologists, technologists, and imaging scientists with expertise in MS. Representatives from the CMSC, Magnetic Resonance Imaging in MS (MAGNIMS), North American Imaging in Multiple Sclerosis Cooperative, US Department of Veteran Affairs, National Multiple Sclerosis Society, Multiple Sclerosis Association of America, MRI manufacturers, and commercial image analysis companies were present. Before the meeting, CMSC members were surveyed about standardized MRI protocols, gadolinium use, need for diffusion-weighted imaging, and the central vein sign. The panel worked to make the CMSC and MAGNIMS MRI protocols similar so that the updated guidelines could ultimately be accepted by international consensus. Advocacy efforts will promote the importance of standardized MS MRI protocols. Dissemination will include publications, meeting abstracts, educational programming, webinars, "meet the expert" teleconferences, and examination cards. Implementation will require comprehensive and coordinated efforts to make the protocol easy to access and use. The ultimate vision, and goal, is for the guidelines to be universally useful, usable, and used as the standard of care for patients with MS.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...