Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 122
Filtrar
1.
Hepatology ; 2024 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-38447034

RESUMEN

BACKGROUND AND AIMS: Compensated advanced chronic liver disease (cACLD) identifies patients at risk for clinically significant portal hypertension (CSPH), and thus, for liver-related complications. The limited availability of liver stiffness measurements (LSM) impedes the identification of patients at risk for cACLD/CSPH outside of specialized clinics. We aimed to develop a blood-based algorithm to identify cACLD by fibrosis-4 (FIB-4) and CSPH by von Willebrand factor/platelet count ratio (VITRO). APPROACH AND RESULTS: Patients with (suspected) compensated chronic liver disease undergoing FIB-4+LSM were included in the LSM/FIB-4 cohorts from Vienna and Salzburg. The HVPG/VITRO cohorts included patients undergoing HVPG-measurement + VITRO from Vienna and Bern.LSM/FIB-4-derivation-cohort: We included 6143 patients, of whom 211 (3.4%) developed hepatic decompensation. In all, 1724 (28.1%) had LSM ≥ 10 kPa, which corresponded to FIB-4 ≥ 1.75. Importantly, both LSM (AUROC:0.897 [95% CI:0.865-0.929]) and FIB-4 (AUROC:0.914 [95% CI:0.885-0.944]) were similarly accurate in predicting hepatic decompensation within 3 years. FIB-4 ≥ 1.75 identified patients at risk for first hepatic decompensation (5 y-cumulative incidence:7.6%), while in those <1.75, the risk was negligible (0.3%).HVPG/VITRO-derivation cohort: 247 patients of whom 202 had cACLD/FIB-4 ≥ 1.75 were included. VITRO exhibited an excellent diagnostic performance for CSPH (AUROC:0.889 [95% CI:0.844-0.934]), similar to LSM (AUROC:0.856 [95% CI:0.801-0.910], p = 0.351) and the ANTICIPATE model (AUROC:0.910 [95% CI:0.869-0.952], p = 0.498). VITRO < 1.0/ ≥ 2.5 ruled-out (sensitivity:100.0%)/ruled-in (specificity:92.4%) CSPH. The diagnostic performance was comparable to the Baveno-VII criteria.LSM/FIB-4-derivation cohort findings were externally validated in n = 1560 patients, while HVPG/VITRO-derivation-cohort findings were internally (n = 133) and externally (n = 55) validated. CONCLUSIONS: Simple, broadly available laboratory tests (FIB-4/VITRO) facilitate cACLD detection and CSPH risk stratification in patients with (suspected) liver disease. This blood-based approach is applicable outside of specialized clinics and may promote early intervention.

2.
Aliment Pharmacol Ther ; 59(11): 1376-1386, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38482706

RESUMEN

BACKGROUND AND AIMS: The prognostic performance of von Willebrand factor (VWF) may vary across clinical stages of advanced chronic liver disease (ACLD). Therefore, we investigated the evolution of VWF and other biomarkers throughout the full ACLD spectrum and evaluated their stage-specific prognostic utility. METHODS: We retrospectively included Viennese ACLD patients with available information on hepatic venous pressure gradient (HVPG), C-reactive protein (CRP)/VWF levels and outcomes. ACLD stages were defined according to D'Amico et al. We included an external validation cohort from Padua. RESULTS: We observed gradual increases in VWF throughout ACLD stages. In contrast, HVPG levelled off in decompensated ACLD (dACLD), whereas MELD showed only minor changes in the early stages and CRP did not increase until stage 3. VWF was associated with hepatic decompensation/liver-related death in compensated ACLD (cACLD) in a fully adjusted model, while it was not independently predictive of ACLF/liver-related death in dACLD. After backward selection, HVPG/CRP/VWF remained the main predictors of hepatic decompensation/liver-related death in cACLD. Notably, the performance of the non-invasive CRP/VWF-based model was comparable to invasive HVPG-based models (C-index:0.765 ± 0.034 vs. 0.756 ± 0.040). The discriminative ability of the CRP/VWF-based model was confirmed in an external validation cohort using another VWF assay which yielded systematically lower values. CONCLUSION: VWF is the only biomarker that gradually increases across all ACLD stages. It is of particular prognostic value in cACLD, where a CRP/VWF-based model is equivalent to an invasive HVPG-based model. Systematic differences in VWF underline the importance of interlaboratory surveys. Moreover, our findings reinforce the notion that, already in cACLD, inflammation is a key disease-driving mechanism.


Asunto(s)
Biomarcadores , Proteína C-Reactiva , Factor de von Willebrand , Humanos , Factor de von Willebrand/metabolismo , Factor de von Willebrand/análisis , Masculino , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Biomarcadores/sangre , Proteína C-Reactiva/análisis , Pronóstico , Anciano , Hepatopatías/sangre , Hepatopatías/mortalidad , Enfermedad Crónica , Adulto , Índice de Severidad de la Enfermedad , Valor Predictivo de las Pruebas
3.
Br J Anaesth ; 132(2): 343-351, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37925268

RESUMEN

BACKGROUND: Tranexamic acid is an antifibrinolytic drug that is commonly administered for obstetric haemorrhage. Conventional viscoelastic tests are not sensitive to tranexamic acid, but the novel ClotPro® TPA-test can measure tranexamic acid-induced inhibition of fibrinolysis. We aimed to evaluate the TPA-test in pregnant and non-pregnant women. METHODS: We performed an in vitro study of whole blood samples spiked with tranexamic acid from pregnant women in the first, second, and third trimester (n=20 per group) and from non-pregnant women (n=20). We performed ClotPro TPA-tests of whole blood sample and ClotPro EX-tests, FIB-tests, and TPA-tests. RESULTS: Clot lysis was inhibited in a concentration-dependent manner up to a tranexamic acid concentration of 6.25 mg L-1. At tranexamic acid concentrations of 12.5 mg L-1 and above, clot lysis was completely inhibited. The concentration-effect relationship of tranexamic acid did not differ in a clinically important manner in blood from pregnant women across all three trimesters or from non-pregnant controls. A median maximum lysis cut-off value of at9 least 16% (25-75th percentiles 15-18), a median clot lysis time of 3600 s (25-75th percentiles 3600-3600), or both was associated with a tranexamic acid concentration of least 12.5 mg L-1. CONCLUSIONS: The ClotPro® TPA-test is sensitive in detecting inhibition of fibrinolysis by tranexamic acid in whole blood samples of pregnant and non-pregnant women. The concentration-effect relationship of tranexamic acid to inhibit fibrinolysis in whole blood did not differ for women in the first, second, and third trimester or for non-pregnant women.


Asunto(s)
Antifibrinolíticos , Ácido Tranexámico , Femenino , Humanos , Embarazo , Fibrinólisis , Ácido Tranexámico/farmacología , Activador de Tejido Plasminógeno/farmacología , Tiempo de Lisis del Coágulo de Fibrina , Antifibrinolíticos/farmacología
4.
J Thromb Haemost ; 22(1): 101-111, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37741511

RESUMEN

BACKGROUND: In patients with mild-to-moderate bleeding disorders (MBD), von Willebrand disease (VWD) is diagnosed at von Willebrand factor (VWF) levels ≤50 IU/dL. Although VWF levels are unstable, repeated testing for VWD diagnosis is not necessarily advised in recent guidelines. OBJECTIVES: To analyze the relevance of repeated VWF testing to diagnose VWD in patients with MBD. METHODS: Data of 277 patients with MBD from the Vienna Bleeding Biobank with at least 2 separate assessments of VWF antigen (VWF:Ag) and activity (VWF:Act) were analyzed. RESULTS: In repeated VWF measurements, 36 patients (13.0%) had "changing" VWF levels (≤/>50 IU/dL), 27 (9.7%) had persistent levels ≤50 IU/dL ("pathologic"), and 214 (77.3%) had levels >50 IU/dL ("normal"). Of the 36 changing patients, 22 (61%) were diagnosed with VWD at baseline, whereas the others only met VWD diagnostic criteria at repeated measurements. Using logistic regression, we estimated a probability of change of 26.4% (95% CI, 12.5-47.4) at baseline VWF levels of 30 IU/dL, 50.8% (95% CI, 35.6-65.8) at 50 IU/dL, 18.8% (95% CI, 12.3-27.6) at 60 IU/dL, and 1.2% (95% CI, 0.3-4.9) at 80 IU/dL. Baseline VWF was a strong predictor for changing status (Χ2 = 49.9; P < .001), while age, sex, Vicenza score, and blood type O had limited added value (Χ2 = 5.1; P = .278). Baseline VWF:Ag or VWF:Act cutoffs of 80 IU/dL had negative predictive values of 98.1% and 99.1% for changing status, respectively. CONCLUSION: Our data emphasize an overlap between patients with VWD and MBD with bleeding disorder of unknown cause and underline the need for repeated VWF testing, especially in patients with VWF levels <80 IU/dL.


Asunto(s)
Enfermedades de von Willebrand , Adulto , Humanos , Factor de von Willebrand , Hemorragia , Pruebas de Coagulación Sanguínea , Factores de Riesgo
5.
ASAIO J ; 70(3): 217-223, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-37875022

RESUMEN

During extracorporeal membrane oxygenation (ECMO) blood is exposed to artificial surfaces, resulting in contact activation of the intrinsic coagulation pathway initiated by coagulation factor XII (FXII). Little is known about the prevalence of acquired FXII-deficiency, especially during ECMO. The primary outcome was the prevalence of acquired FXII-deficiency (FXII activity <60%) during ECMO. Secondary outcomes included differences in hemorrhagic/thromboembolic complications, doses of unfractionated heparin administered, and time points of anticoagulation within target ranges between patients with and without FXII-deficiency. Of 193 adults receiving ECMO therapy between 2013 and 2021, FXII testing was performed in 64 (33%) patients. Of these, 89% ( n = 57) had an acquired FXII-deficiency. Median complication-free intervals were not different between patients with and without acquired FXII-deficiency (bleeding: 28 days [6-145] vs. 12 days [11-not available], p = 0.85; thromboembolism: 16 days [8-54] vs. 13 days [3-15], p = 0.053). Patients with acquired FXII-deficiency received less heparin (16,554 IU/day vs. 25,839 IU/day; p = 0.009) and were less likely to be within aPTT-target ranges (23.1% [14.3%-36.4%] vs. 37.8% [33.7%-58.3%], p = 0.005). Acquired FXII-deficiency is common during ECMO and may affect monitoring of anticoagulation. The impact of FXII-activity on complications needs to be determined in future studies.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Tromboembolia , Adulto , Humanos , Heparina/efectos adversos , Anticoagulantes/efectos adversos , Oxigenación por Membrana Extracorpórea/efectos adversos , Oxigenación por Membrana Extracorpórea/métodos , Prevalencia , Coagulación Sanguínea , Estudios Retrospectivos
6.
JHEP Rep ; 6(1): 100934, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38074505

RESUMEN

Background & Aims: Increased aggregation of individual platelets upon activation, as assessed by whole blood aggregometry standardised to platelet count (PLT), has recently been linked to progression of advanced chronic liver disease (ACLD). Moreover, changes in primary haemostasis have been implicated in bleeding and thrombosis in patients with ACLD.We aimed (i) to identify the determinants of the primary haemostatic capacity - as assessed by Platelet Function Analyzer 100 (PFA-100) ('in vitro bleeding time') - in patients with ACLD and (ii) to investigate its potential association with clinical outcomes. Methods: PFA-100 was performed in 688 patients with ACLD undergoing hepatic venous pressure gradient measurement. Hepatic decompensation and liver-related death as well as bleeding and thrombosis were the outcomes of interest. Results: Sixty-three percent of patients had a PFA-100 collagen/epinephrine closure time (CT) of >150 s (i.e. prolonged). PLT and haematocrit were the main determinants of CT, whereas it was not impacted by von Willebrand factor antigen. Mirroring the increasing prevalence/severity of thrombocytopaenia and anaemia, we observed a progressive prolongation of CT (i.e. decreased primary haemostatic capacity) with more advanced disease, as indicated by clinical stage, Child-Turcotte-Pugh score, United Network for Organ Sharing model for end-stage liver disease (2016) score, and hepatic venous pressure gradient. Although increased CT (i.e. decreased primary haemostatic capacity) was associated with an increased risk of hepatic decompensation/liver-related death, these associations were less consistent after adjusting/correcting for PLT/haematocrit and established prognostic indicators. Finally, CT was not associated with the incidence of major bleedings or thromboses. Conclusions: These findings do not support the hypothesis that increased platelet adhesion - assessed in vitro under shear stress by PFA-100 - promotes ACLD progression. Impact and implications: The potential of platelets to aggregate in the bloodstream may be increased in patients with advanced chronic liver disease. Platelet Function Analyzer 100 (PFA-100), a blood test reflecting in vitro bleeding time, might be suggestive of an impaired primary clot forming capacity. In our study, we could show that PFA-100 results were not linked to bleeding/thrombotic events. Our findings do not support the hypothesis that an increased adhesion of platelets (assessed by PFA-100) might lead to a disease progression in patients with advanced chronic liver disease.

7.
Clin Appl Thromb Hemost ; 29: 10760296231207062, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37853541

RESUMEN

BACKGROUND: Monitoring of blood coagulation is essential in ECMO patients. We investigated the prevalence of lupus anticoagulant (LA) and its association with coagulation testing and hemostaseologic complications in patients treated with ECMO. METHODS: This is a retrospective analysis including adult patients who received ECMO at a medical intensive care unit at the Medical University of Vienna. The primary outcome was the prevalence of LA. Secondary outcomes included conditions associated with LA positivity, rates of bleeding and thromboembolic events, as well as the proportions of aPTT and antiXa measurements within the target range. RESULTS: Between 2013 and 2021 193 patients received ECMO, in 62 (32%) of whom LA diagnostics were performed. Twenty-two (35%) patients tested positive. LA positive patients had more frequently received VV ECMO (77.3% vs 34.3%; p = 0.002), were more frequently diagnosed with viral respiratory infections (SARS-CoV2: 45.5% vs 20%; p = 0.041, influenza virus: 22.7% vs 0%; p = 0.003), had a longer ECMO treatment duration (25 vs 10 days; p = 0.011) and a longer ICU stay (48 vs 25 days; p = 0.022), but similar rates of bleeding and thromboembolic events.


Asunto(s)
Síndrome Antifosfolípido , Oxigenación por Membrana Extracorpórea , Tromboembolia , Adulto , Humanos , Inhibidor de Coagulación del Lupus , Estudios Retrospectivos , Oxigenación por Membrana Extracorpórea/efectos adversos , Prevalencia , ARN Viral , Hemorragia/epidemiología , Hemorragia/etiología , Tromboembolia/etiología
8.
Hepatol Int ; 17(6): 1532-1544, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37605068

RESUMEN

BACKGROUND AND AIMS: Endothelial dysfunction and portal hypertension (PH) are reflected by increased von Willebrand factor antigen (VWF-Ag) levels in advanced chronic liver disease (ACLD). This study investigated VWF release and cleavage and their association with PH and clinical outcomes. METHODS: Levels of VWF-Ag, VWF-N (VWF-propeptide), and VWF-A (VWF processed by the main VWF-cleaving protease ADAMTS13) were assessed in 229 patients with clinically stable ACLD (hepatic venous pressure gradient [HVPG] ≥ 6 mmHg; absence of bacterial infections or acute decompensation) undergoing HVPG-measurement. Liver-healthy individuals served as controls (n = 24). RESULTS: VWF-Ag and VWF-N were similarly accurate for the identification of clinically significant PH (CSPH; HVPG ≥ 10 mmHg) in compensated ACLD (AUROC: VWF-Ag 0.748; VWF-N 0.728). ADAMTS13 activity was similar between patients with ACLD and controls and did not correlate with PH and disease severity, whereas VWF cleavage decreased in patients with CSPH (i.e., VWF-Ag/-A-ratio increased). In vitro VWF activity strongly reflected VWF-Ag levels (Spearman's r = 0.874, p < 0.001), but decreased (vs. controls) in patients with CSPH when normalized to VWF-Ag levels (VWF-activity/-Ag-ratio). VWF-Act/-Ag ratio correlated negatively with ADAMTS13 activity (r =- 0.256, p < 0.001). ADAMTS13 activity was independently predictive for (i) portal vein thrombosis (PVT) and (ii) hepatic decompensation or liver-related death. CONCLUSIONS: VWF-Ag levels and its propeptide are similarly suitable surrogates of PH in patients with compensated ACLD. ADAMTS13-Act was not linked to disease and PH severity, however, when normalized to VWF-Ag, both VWF cleavage and VWF activity were decreased in patients with CSPH, as compared to liver-healthy individuals. Low ADAMTS13-Act was associated with presumably more procoagulant VWF and adverse outcomes. CLINICAL TRIAL NUMBER: NCT03267615.


Asunto(s)
Hipertensión Portal , Factor de von Willebrand , Humanos , Hipertensión Portal/complicaciones , Cirrosis Hepática/complicaciones , Pruebas de Función Hepática
9.
Res Pract Thromb Haemost ; 7(2): 100047, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36908769

RESUMEN

Background: Although the phenotype of severe hemophilia has been well studied, there are still knowledge gaps in nonsevere hemophilia. Objectives: The objective of this study was to characterize the clinical bleeding phenotype in nonsevere hemophilia and its association with different factor VIII/IX assessments. Methods: This was a cross-sectional, multicenter study to investigate the bleeding phenotype in adults with nonsevere hemophilia by the number of bleeding and joint bleeding in the past 5 years, a joint score, and the International Society on Thrombosis and Haemostasis bleeding assessment tool (ISTH-BAT). Factor levels were analyzed by 1-stage (lowest in history and at study inclusion) and chromogenic assay (at study inclusion). Patients were enrolled between March 2015 and May 2019. Results: Of the 111 patients (86 with mild and 25 with moderate hemophilia), 57 patients (54.8%) reported any bleeding and 24 (23.1%) any joint bleeding in the past 5 years. A joint score ≥1 was found in 44 patients (41.9%), an ISTH-BAT ≥4 in 100 patients (90.1%), and an ISTH-BAT joint item ≥1 in 50 patients (45.0%). Within the ISTH-BAT, muscle and joint bleeds showed the largest difference between mild and moderate hemophilia. The lowest factor VIII/IX level in patients' history was best associated with bleeding outcomes. Factor was inversely associated with joint bleeds (incidence rate ratio 0.88; 95% CI, 0.79-0.98), joint score, and ISTH-BAT (odds ratios from proportional odds ordinal logistic regression 0.92; 95% CI, 0.87-0.97; and 0.89; 95% CI, 0.86-0.93, respectively). Conclusion: The occurrence of joint bleeding differentiated persons with mild and moderate hemophilia. The ISTH-BAT and lowest factor in patients' history provided valuable information of the bleeding phenotype in nonsevere hemophilia.

10.
Thromb Res ; 222: 124-130, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36646026

RESUMEN

BACKGROUND: Patients with advanced chronic liver disease (ACLD) may develop a prothrombotic phenotype that seems to be more pronounced with more severe liver dysfunction. An imbalance of endogenous pro- and anticoagulants is not fully captured by routine coagulation assays. METHODS: In a cohort of ACLD patients undergoing hepatic venous pressure gradient (HVPG) measurement, we assessed thrombin generation (TGA) using two commercially available assays (Technothrombin and Thrombinoscope) with and without addition of soluble thrombomodulin (TM), as well as thrombin activity, alongside a panel of coagulation parameters. RESULTS: The cohort encompassed 37 patients (median age 55.3 years, mean HVPG 16 ± 5 mm Hg). In the TM-modified Thrombinoscope TGA, the endogenous thrombin generation potential (ETP) was significantly increased in Child-Pugh-Score (CPS) B/C patients (N = 23, 62 %) compared to CPS A patients (N = 14, 38 %) (ETP: 546 nM∗min (443-696) vs. 404 nM∗min (289-573), p = 0.028). Using the Technothrombin TGA without TM, patients with CPS B/C had decreased ETP compared to CPS A patients (ETP: 2792 ± 1336 nM∗min vs. 5040 ± 816 nM∗min, p < 0.001) and with addition of TM (final concentration: 5 nM; ETP: 2545 ± 1327 nM∗min vs. 4824 ± 929 nM∗min, p < 0.001). Thrombin activity levels were 0.6pM in median (0.2-1.6pM) and above the level of detectability (0.10pM) in 94.6 % of patients but were not correlated to severity of cirrhosis (CPS A 0.7pM vs CPS B/C 0.4pM, p = 0.377) nor to parameters of TGA. CONCLUSION: Thrombin plasma levels are elevated in liver disease patients without apparent correlation to TGA or severity of cirrhosis. TGAs can be modified with TM to enable protein C-dependent anticoagulation, but result in differences with regard to severity of liver disease.


Asunto(s)
Hipertensión Portal , Trombina , Humanos , Trombina/metabolismo , Cirrosis Hepática/complicaciones , Coagulación Sanguínea , Fenotipo
11.
Clin Gastroenterol Hepatol ; 21(7): 1854-1863.e10, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36244661

RESUMEN

BACKGROUND & AIMS: Baveno VII proposed liver stiffness measurement (LSM)/platelet count (PLT)-based criteria ('ruled out,' LSM ≤15 kPa plus PLT ≥150 G/L; 'ruled in': LSM ≥25 kPa) for clinically significant portal hypertension (CSPH) in compensated advanced chronic liver disease (cACLD). However, a substantial proportion of patients remains 'unclassified.' METHODS: Patients with evidence of cACLD (LSM ≥10 kPa) undergoing hepatic venous pressure gradient (HVPG) measurement at the Vienna General Hospital 2004 to 2021 (derivation [2004-2016], n = 221; validation [2017-2021], n = 81) were included. The performance of noninvasive tests (NITs) including von Willebrand factor antigen to PLT ratio (VITRO) for the detection of CSPH (HVPG ≥10 mmHg) were evaluated. RESULTS: Overall, viral hepatitis was the predominant (50.7%) etiology, followed by alcoholic liver disease (15.2%) and nonalcoholic steatohepatitis (13.2%); CSPH prevalence was 62.3%. In the derivation cohort, 45.7% were 'unclassified' according to Baveno VII criteria; in this group, VITRO showed an excellent diagnostic performance for the detection of CSPH (area under the receiver operating curve, 0.909; 95% confidence interval, 0.823-0.965). VITRO ≤1.5 and ≥2.5 ruled out (sensitivity, 97.7%; negative predictive value, 97.5%) and ruled in (specificity, 94.7%; positive predictive value, 91.2%), respectively, CSPH in patients who were 'unclassifiable' by Baveno VII criteria. The application of a sequential Baveno VII-VITRO algorithm reallocated 73% and 70% of 'unclassified' patients to the 'ruled in' and 'ruled out' group, respectively, while maintaining high sensitivity and negative predictive value and specificity and positive predictive value in the derivation and validation cohort, respectively. No patient allocated to the 'CSPH ruled out' group by the Baveno VII-VITRO algorithm developed decompensation within 5 years, whereas 5-year decompensation rates were negligible (4%) and substantial (23.9%) among 'unclassified' and 'CSPH ruled in' patients, respectively. CONCLUSIONS: The sequential application of VITRO in patients with cACLD who were 'unclassifiable' with regard to CSPH by Baveno VII criteria substantially decreased the number of 'unclassifiable' patients to <15% and refined prognostication.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Várices Esofágicas y Gástricas , Hipertensión Portal , Hepatopatías Alcohólicas , Humanos , Hipertensión Portal/diagnóstico , Cirrosis Hepática/diagnóstico
12.
Blood ; 141(10): 1147-1158, 2023 03 09.
Artículo en Inglés | MEDLINE | ID: mdl-36108308

RESUMEN

Factor VIII (FVIII) circulates in a noncovalent complex with von Willebrand Factor (VWF), the latter determining FVIII half-life. The VWF-binding aptamer rondaptivon pegol (BT200) increases plasma levels of VWF/FVIII in healthy volunteers. This trial assessed its safety, pharmacokinetics, and pharmacodynamics in hemophilia A. Nineteen adult patients (ages 20-62 years, 4 women) with hemophilia A (8 mild, 2 moderate, and 9 severe) received subcutaneous injections of rondaptivon pegol. After an initial fixed dose of 3 mg on days 0 and 4, patients received weekly doses of 2 to 9 mg until day 28. Severe hemophilia A patients underwent sparse-sampling population pharmacokinetics individual profiling after the final dose of rondaptivon pegol. Adverse events, pharmacokinetics, and pharmacodynamics were assessed. FVIII activity and VWF levels were measured. All patients tolerated rondaptivon pegol well. The geometric mean half-life of rondaptivon pegol was 5.4 days and rondaptivon pegol significantly increased VWF levels. In severe hemophilia A, 6 doses of rondaptivon pegol increased the half-lives of 5 different FVIII products from a median of 10.4 hours to 31.1 hours (range, 20.8-56.0 hours). Median FVIII increased from 22% to 48% in mild hemophilia A and from 3% to 7.5% in moderate hemophilia A. Rondaptivon pegol is a first-in-class prohemostatic molecule that extended the half-life of substituted FVIII approximately 3-fold and increased endogenous FVIII levels approximately 2-fold in hemophilia patients. This trial was registered at www.clinicaltrials.gov as #NCT04677803.


Asunto(s)
Hemofilia A , Hemostáticos , Adulto , Humanos , Femenino , Adulto Joven , Persona de Mediana Edad , Factor de von Willebrand/uso terapéutico , Hemofilia A/tratamiento farmacológico , Factor VIII , Hemostáticos/uso terapéutico , Semivida
13.
J Clin Pathol ; 76(11): 770-777, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36041815

RESUMEN

BACKGROUND: Serological tests are widely used in various medical disciplines for diagnostic and monitoring purposes. Unfortunately, the sensitivity and specificity of test systems are often poor, leaving room for false-positive and false-negative results. However, conventional methods were used to increase specificity and decrease sensitivity and vice versa. Using SARS-CoV-2 serology as an example, we propose here a novel testing strategy: the 'sensitivity improved two-test' or 'SIT²' algorithm. METHODS: SIT² involves confirmatory retesting of samples with results falling in a predefined retesting zone of an initial screening test, with adjusted cut-offs to increase sensitivity. We verified and compared the performance of SIT² to single tests and orthogonal testing (OTA) in an Austrian cohort (1117 negative, 64 post-COVID-positive samples) and validated the algorithm in an independent British cohort (976 negatives and 536 positives). RESULTS: The specificity of SIT² was superior to single tests and non-inferior to OTA. The sensitivity was maintained or even improved using SIT² when compared with single tests or OTA. SIT² allowed correct identification of infected individuals even when a live virus neutralisation assay could not detect antibodies. Compared with single testing or OTA, SIT² significantly reduced total test errors to 0.46% (0.24-0.65) or 1.60% (0.94-2.38) at both 5% or 20% seroprevalence. CONCLUSION: For SARS-CoV-2 serology, SIT² proved to be the best diagnostic choice at both 5% and 20% seroprevalence in all tested scenarios. It is an easy to apply algorithm and can potentially be helpful for the serology of other infectious diseases.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Estudios Seroepidemiológicos , Técnicas de Laboratorio Clínico/métodos , Prueba de COVID-19 , Sensibilidad y Especificidad
14.
Int J Mol Sci ; 23(24)2022 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-36555414

RESUMEN

Venous and arterial thromboembolism (VTE/ATE) are common complications in cancer patients. Antithrombin deficiency is a risk factor for thrombosis in the general population, but its connection to risk of cancer-associated thrombosis is unclear. We investigated the association of antithrombin activity levels with risk of cancer-associated VTE/ATE and all-cause mortality in an observational cohort study including patients with cancer, the Vienna Cancer and Thrombosis Study. In total, 1127 patients were included (45% female, median age: 62 years). Amongst these subjects, 110 (9.7%) patients were diagnosed with VTE, 32 (2.8%) with ATE, and 563 (49.9%) died. Antithrombin was not associated with a risk of VTE (subdistribution hazard ratio (SHR): 1.00 per 1% increase in antithrombin level; 95% CI: 0.99-1.01) or ATE (SHR: 1.00; 95% CI: 0.98-1.03). However, antithrombin showed a u-shaped association with the risk of all-cause death, i.e., patients with very low but also very high levels had poorer overall survival. In the subgroup of patients with brain tumors, higher antithrombin levels were associated with ATE risk (SHR: 1.02 per 1% increase; 95% CI: 1.00-1.04) and mortality (HR: 1.01 per 1% increase; 95% CI: 1.00-1.02). Both high and low antithrombin activity was associated with the risk of death. However, no association with cancer-associated VTE and ATE across all cancer types was found, with the exception of in brain tumors.


Asunto(s)
Neoplasias Encefálicas , Trombosis , Tromboembolia Venosa , Humanos , Femenino , Persona de Mediana Edad , Masculino , Antitrombinas , Tromboembolia Venosa/epidemiología , Antitrombina III , Trombosis/complicaciones , Factores de Riesgo , Neoplasias Encefálicas/complicaciones
15.
Dig Liver Dis ; 54(10): 1376-1384, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35871985

RESUMEN

BACKGROUND: Von Willebrand factor antigen (VWF) is a non-invasive marker for clinically significant portal hypertension (HVPG≥10 mmHg) and confers HVPG-independent prognostic information. While quantification of increased VWF-levels is not relevant in the context of von Willebrand disease, highly elevated VWF may be of clinical significance in ACLD. Thus, we have modified our analytical approach to quantify very high VWF-levels (i.e.,>420%) and investigated their prognostic value. METHODS: Patients undergoing HVPG-measurement at the Vienna Hepatic Hemodynamic Lab with evidence of ACLD and information on VWF were considered. Clinical stages (CS) were defined as follows: Probable compensated ACLD (cACLD): LSM≥10kPa&HVPG<6 mmHg; 0: cACLD&6-9 mmHg; 1: cACLD&HVPG≥10 mmHg; 2: bleeding; 3: non-bleeding decompensation; 4: ≥2 decompensations. RESULTS: 124 (16%) of 793 patients had VWF>420%. The proportion of VWF>420% increased with disease severity (probable cACLD-0: 5(4%) vs. 1: 22(10%) vs. 2-4: 97(23%),p ≤ 0.001) as well as across HVPG (<6mmHg: 1(2%) vs. 6-9: 6(6%) vs. 10-15: 17(9%) vs. ≥16: 100(22%),p ≤ 0.001) and MELD (<10: 17(6%) vs. 10-14: 27(10%) vs. ≥15: 79(32%),p ≤ 0.001) strata. In patients with VWF>420%, median VWF was 533 (IQR:466-611)% and VWF was unrelated to HVPG (Spearman's ρ=0.139,p = 0.123), but showed direct correlations of weak/moderate strength with MELD (ρ=0.336,p < 0.001) and CRP (ρ=0.286,p = 0.001). In the subgroup with VWF>420%, VWF was predictive of decompensation/liver-related mortality (VWF per 10%; hazard ratio (HR): 1.02(95% confidence interval (95%CI): 1.01-1.04),p = 0.008, even after adjusting for other factors (VWF per 10%; adjusted HR: 1.02(95%CI: 1.00-1.05),p = 0.031). CONCLUSION: The proportion of patients with substantially elevated VWF values steadily increases with disease progression. While VWF is not reflective of HVPG in these patients, it is correlated with hepatic dysfunction and systemic inflammation. Importantly, quantification of high values provides prognostic information.


Asunto(s)
Hipertensión Portal , Factor de von Willebrand , Biomarcadores , Humanos , Cirrosis Hepática
16.
Biochem Med (Zagreb) ; 32(2): 020713, 2022 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-35799989

RESUMEN

Introduction: Point-of-care (POC) platelet function tests are faster and easier to perform than in-depth assessment by flow cytometry. At low platelet counts, however, POC tests are prone to assess platelet function incorrectly. Lower limits of platelet count required to obtain valid test results were defined and a testing method to facilitate comparability between different tests was established. Materials and methods: We assessed platelet function in whole blood samples of healthy volunteers at decreasing platelet counts (> 100, 80-100, 50-80, 30-50 and < 30 x109/L) using two POC tests: impedance aggregometry and in-vitro bleeding time. Flow cytometry served as the gold standard. The number of platelets needed to reach 50% of the maximum function (ED50) and the lower reference limit (EDref) were calculated to define limits of test validity. Results: The minimal platelet count required for reliable test results was 100 x109/L for impedance aggregometry and in-vitro bleeding time but only 30 x109/L for flow cytometry. Comparison of ED50 and EDref showed significantly lower values for flow cytometry than either POC test (P value < 0.05) but no difference between POC tests nor between the used platelet agonists within a test method. Conclusion: Calculating the ED50 and EDref provides an effective way to compare values from different platelet function assays. Flow cytometry enables correct platelet function testing as long as platelet count is > 30 x109/L whereas impedance aggregometry and in-vitro bleeding time are inconsistent unless platelet count is > 100 x109/L.


Asunto(s)
Agregación Plaquetaria , Trombocitopenia , Plaquetas , Citometría de Flujo , Humanos , Recuento de Plaquetas , Pruebas de Función Plaquetaria/métodos , Sistemas de Atención de Punto
17.
Blood Adv ; 6(18): 5467-5476, 2022 09 27.
Artículo en Inglés | MEDLINE | ID: mdl-35772170

RESUMEN

Type 2B von Willebrand disease (VWD) is characterized by an increased binding affinity of von Willebrand factor (VWF) to platelet glycoprotein Ib. This can lead to clearance of high-molecular-weight (HMW) multimers and thrombocytopenia with a resulting moderate-severe bleeding phenotype. Rondoraptivon pegol (BT200) is a pegylated aptamer binding to the A1 domain of VWF with a novel mechanism of action: it enhances VWF/factor VIII (FVIII) levels by decreasing their clearance. To study the potential benefit of rondoraptivon pegol in patients with type 2B VWD, we conducted a prospective phase 2 trial. Patients with type 2B VWD received 3 mg rondoraptivon pegol subcutaneously on study days 1, 4, and 7, followed by 6 to 9 mg every week until day 28. Five patients (male:female ratio = 3:2) were included. Rondoraptivon pegol rapidly tripled platelet counts from a median of 60 to 179 × 10E9/L (P < .001). Circulating VWF antigen increased from a median of 64% to 143%, which doubled FVIII activity levels from 67% to 134%. In all thrombocytopenic patients, plasma levels of VWF:GPIbM normalized, VWF ristocetin cofactor and VWF collagen-binding activity increased, and HMW multimers appeared. These pronounced improvements reversed during washout of the drug, thus demonstrating causality. The A1 domain binding aptamer directly corrects the underlying defect of type 2B VWD, thus providing a novel potential option for prophylaxis and treatment of patients with this VWD type. These data provide the basis for a phase 2b/3 trial in such patients. This trial was registered at www.clinicaltrials.gov as #NCT04677803.


Asunto(s)
Hemostáticos , Enfermedad de von Willebrand Tipo 2 , Enfermedades de von Willebrand , Colágeno , Factor VIII/uso terapéutico , Femenino , Hemostáticos/uso terapéutico , Humanos , Masculino , Recuento de Plaquetas , Complejo GPIb-IX de Glicoproteína Plaquetaria/metabolismo , Polietilenglicoles/uso terapéutico , Estudios Prospectivos , Enfermedades de von Willebrand/tratamiento farmacológico , Factor de von Willebrand/metabolismo
18.
J Clin Lab Anal ; 36(4): e24294, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35274775

RESUMEN

INTRODUCTION: We conducted a multicenter evaluation of a new one-stage factor VIII (FVIII) assay (Roche Diagnostics), intended for the quantitative assessment of FVIII activity. We evaluated the analytical performance of the FVIII assay on the cobas t 711 analyzer. METHODS: Experiments performed at three laboratories used 3.2% citrated residual or commercially purchased plasma samples. Five human plasma pools and two controls were used to determine assay within-run and within-laboratory precision, and total reproducibility; coefficients of variation (CVs) and/or standard deviations (SDs) were calculated. Lot-to-lot variability and method comparison (vs Coagulation FVIII Deficient Plasma/Dade Actin FS Activated PTT reagent/Standard Human Plasma Calibrator on the Sysmex CS-5100 analyzer; Siemens Healthineers) were evaluated by Passing-Bablok and Deming regression, respectively, and Pearson's r calculated. Assay-specific reference range was determined using 199 fresh plasma samples from healthy adults, not receiving anticoagulants. RESULTS: Across sites, SDs for repeatability were 0.016-0.046 for samples with ≤1.0 international units (IU)/dL FVIII activity; CVs were 0.9%-3.8% for samples with >1.0 IU/dl activity. Among samples with mean FVIII activity 0.344-133 IU/dl, good intermediate precision (SD 0.020 for samples with 0.344 IU/dl activity; CV 1.8%-4.7%) and good total reproducibility (CV 2.0%-13.3%) were observed. The FVIII assay showed excellent lot-to-lot variability (Pearson's r = .999) and good correlation with the comparator assay (Pearson's r = .993-.996). The reference range for FVIII activity was 82.2-218.0 IU/dl. CONCLUSION: The one-stage FVIII assay demonstrated robust analytical performance on the cobas t 711 analyzer, supporting its use in routine laboratory practice.


Asunto(s)
Factor VIII , Hemofilia A , Adulto , Pruebas de Coagulación Sanguínea , Hemofilia A/diagnóstico , Humanos , Valores de Referencia , Reproducibilidad de los Resultados
19.
Pharmaceutics ; 14(3)2022 Mar 17.
Artículo en Inglés | MEDLINE | ID: mdl-35336036

RESUMEN

Direct oral anticoagulants (DOACs) are safe and effective in cancer patients treated for venous thromboembolism (VTE) or atrial fibrillation (AF). Gastrectomy is the treatment of choice in patients with localized upper gastrointestinal cancer. DOACs are absorbed in the upper gastrointestinal tract, but to what extent is unclear. In a retrospective analysis, hospital data were searched for adult patients who underwent gastrectomy for gastroesophageal or pancreatic cancer, and DOAC therapy for VTE or AF after gastrectomy. DOAC blood levels were determined by chromogenic assays before and after administration, and thromboembolic and bleeding complications were recorded. Eleven patients (median age 76 years) received a factor Xa inhibitor (FXaI; apixaban (3), edoxaban (3), rivaroxaban (4)) or the factor IIa inhibitor dabigatran (1) for VTE (7) or AF (4) after gastrectomy. Eight patients on FXaI had anti-Xa (aXa) trough levels within the expected range (ER). In all of them, aXa levels increased upon DOAC administration. Two patients on 30 mg edoxaban had low aXa trough levels. Administration of 20 mg of rivaroxaban resulted in trough levels in the ER in one of them. None of the FXaI patients had thromboembolism, while two experienced bleeding (arterial puncture site, gastrointestinal). One dabigatran AF patient with trough and peak concentrations below the ER had strokes during 110 mg and 150 mg dabigatran administration. While on apixaban, aXa levels were in the ER, and no clinical complications occurred. DOACs, particularly FXaI, were adequately absorbed in cancer patients after gastrectomy. Our observation of recurrent thromboembolic events in a patient treated with dabigatran warrants cautious use in this specific patient population.

20.
Blood Adv ; 6(10): 2957-2966, 2022 05 24.
Artículo en Inglés | MEDLINE | ID: mdl-35042230

RESUMEN

Data on lupus anticoagulant (LA) test stability in patients persistently positive for LA are limited, and its implications on clinical outcomes are lacking. We investigated the rate and predictors of a negative LA test and whether experiencing a negative test affected a patient's risk of future thrombotic events or death in a prospective observational study of persistently LA+ patients. We followed 164 patients (84% women) for a median of 9.2 years and a total of 1438 follow-up visits. During the observation period, 50 thrombotic events (23 arterial and 27 venous events) occurred, and 24 patients died. Forty-six of the patients had at least 1 negative LA test during the observation period, corresponding to a 10-year cumulative incidence of a negative LA test of 28% (95% confidence interval, 20-35). The majority of patients with available follow-up after a negative LA test (n = 41) had at least 1 subsequent positive test for LA (n = 28/41, 68%). Vitamin K antagonist (VKA) treatment at baseline was associated with a negative LA test during follow-up. Using a multistate time-to-event model with multivariable adjustment, a negative LA test had no impact on a patient's prospective risk of thrombosis or mortality. We conclude that a negative LA test during observation cannot be used clinically to stratify a patient's risk for future events.


Asunto(s)
Inhibidor de Coagulación del Lupus , Trombosis , Anticoagulantes/uso terapéutico , Pruebas de Coagulación Sanguínea , Femenino , Humanos , Masculino , Estudios Prospectivos , Trombosis/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...