Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Healthcare (Basel) ; 12(4)2024 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-38391790

RESUMEN

BACKGROUND: The Knee Injury and Osteoarthritis Outcome Score (KOOS) scale is used to assess patient perspectives on knee health. However, the structural validity of the KOOS has not been sufficiently tested; therefore, our objective was to assess the KOOS in a large, multi-site database of patient responses who were receiving care for knee pathology. METHODS: A cross-sectional study was conducted using the Surgical Outcome System (SOS) database. A confirmatory factor analysis (CFA) was conducted to assess the proposed five-factor KOOS using a priori cut-off values. Because model fit indices were not met, a subsequent exploratory factor analysis (EFA) was conducted to identify a parsimonious model. The resulting four-factor structure (i.e., KOOS SF-12) was then assessed using CFA and subjected to multigroup invariance testing. RESULTS: The original KOOS model did not meet rigorous CFA fit recommendations. The KOOS SF-12 did meet model fit recommendations and passed all invariance testing between intervention procedure, sex, and age groups. CONCLUSION: The KOOS failed to meet model fit recommendations. The KOOS SF-12 met model fit recommendations, maintained a multi-factorial structure, and was invariant across all tested groups. The KOOS did not demonstrate sound structural validity. A refined KOOS SF-12 model that met recommended model fit indices and invariance testing criteria was identified. Our findings provide initial support for a multidimensional KOOS structure (i.e., KOOS SF-12) that is a more psychometrically sound instrument for measuring patient-reported knee health.

2.
ACS Appl Bio Mater ; 3(3): 1681-1689, 2020 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-33738440

RESUMEN

Free-standing, composite hydrogels containing the visible-light responsive metal-free semiconductor graphitic carbon nitride (g-C3N4) as an integral component have been fabricated by direct casting techniques. At 0.67% g-C3N4 loading, intermolecular interactions between the semiconductor particles and the PVA polymer chains enhance both the mechanical and photophysical properties of the resulting hydrogels. In contrast, much higher g-C3N4 loadings of 3.3 or 6.7% g-C3N4 resulted in growth of the average semiconductor particle size and reduction in interactions between the incorporated photocatalyst and the PVA chains. The increased dimensions of the g-C3N4 semiconductor particles had the effect of compromising the mechanical properties of the composite system and reducing the lifetime of photogenerated charge carriers. However, the close proximity of g-C3N4 particles that is realized at increased semiconductor loading densities improves the absorption cross section of the material, resulting in an overall improvement in the photocatalytic activity of the material. Application of visible radiation caused all of the composite hydrogels to generate hydrogen peroxide (H2O2) at catalytic rates of 0.9-2.5 µM/min, while H2O2 decomposition rates remained similar across the different preparations. In studies to examine antimicrobial performance, irradiation of 6.7% g-C3N4/PVA hydrogel samples with visible radiation (400 ≤ λ ≤ 800 nm) generated sufficient H2O2 to significantly reduce both the viable planktonic cell population and biofilm formation in cultures of Pseudomonas aeruginosa.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA