Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Ann Vasc Surg ; 99: 389-399, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37918659

RESUMEN

BACKGROUND: To determine the prevalence, the clinical and radiological features, associated factors, treatment, and outcome of splenic artery aneurysms (SAAs) in infective endocarditis (IE). METHODS: We retrospectively reviewed 474 consecutive patients admitted to our institution with definite IE (2005-2020). RESULTS: Six patients had SAAs (1.3%; 3 women; mean age: 50 years). In all cases, the diagnosis was obtained by abdominal computed tomography angiography (CTA). SAAs-IE were solitary and saccular with a mean diameter of 30 mm (range: 10-90 mm). SAAs-IE were intrasplenic (n = 4) or hilar (n = 2). Streptococcus spp. were the predominant organisms (n = 4). In all cases, a left-sided native valve was involved (aortic, n = 3; mitral, n = 2; mitral-aortic, n = 1). SAAs were silent in half patients and were revealed by abdominal pain (n = 2) and by the resurgence of fever after cardiac surgery (n = 1). All patients underwent emergent valve replacement. One patient died within 24 hr from multiorgan failure. For the others, uneventful coil embolization was performed in 4 patients after valve replacement (3 diagnosed early and 1 at 8 weeks). In the remaining patient, SAA-IE diagnosed at abdominal CTA at day 16, with complete resolution under appropriate antibiotherapy alone. CONCLUSIONS: SAAs-IE are a rare occurrence that may be clinically silent. SAAs-IE can be intrasplenic or hilar in location. Endovascular treatment in this context was safe. According to current guidelines, radiologic screening by abdominal CTA allowed the detection of silent SAAs which could be managed by endovascular treatment to prevent rupture. The delayed formation of these SAAs could justify a CTA control at the end of antibiotherapy.


Asunto(s)
Aneurisma , Enfermedades Transmisibles , Endocarditis Bacteriana , Endocarditis , Humanos , Femenino , Persona de Mediana Edad , Arteria Esplénica/diagnóstico por imagen , Estudios Retrospectivos , Resultado del Tratamiento , Aneurisma/terapia , Aneurisma/cirugía , Endocarditis Bacteriana/diagnóstico por imagen , Endocarditis Bacteriana/terapia , Endocarditis/diagnóstico por imagen , Endocarditis/terapia , Estudios Observacionales como Asunto
2.
Eur J Cardiothorac Surg ; 64(6)2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-37843446

RESUMEN

OBJECTIVES: Patients undergoing surgical tricuspid valve replacement (TVR) are at high risk of atrioventricular conduction disorders. Because implanting a lead through the tricuspid bioprosthesis is discouraged, the patients who undergo TVR in our centre are usually given a prophylactic epicardial pacemaker. Our aim was to assess the benefits and risks of this strategy. METHODS: Among the patients who underwent TVR with prophylactic epicardial pacemaker implantation, clinical evaluations and pacemaker reports were analysed retrospectively after surgery. The need for cardiac pacing were assessed by characterizing the atrioventricular conduction, while the risks were evaluated by listing and adjudicating post-operative events. RESULTS: A total of 80 patients were analysed (mean age was 57 ± 16 years old, 30% males). TVR was isolated in 28 (35%) patients, but most often associated with another valve surgery. In the postoperative period, heart rhythm was analysed in 59/80 patients during a median follow-up of 35 months. Cardiac pacing was needed in 46% patients: 14% had complete pacing dependency, 17% had high degree AV block, while 15% had a high ventricular pacing rate (>80%). No pre- or per-operative variables could predict cardiac pacing requirement. Post-operatively, a spontaneous heart rate >70 bpm (P = 0.02) and the presence of narrow QRS (P = 0.03) were significantly associated with a lower risk of cardiac pacing requirement. Complications related to epicardial pacemaker were documented in 2 (2.5%) patients. CONCLUSIONS: After TVR, cardiac pacing was needed in 46% of patients for post-operative atrioventricular conduction disorders. This high incidence associated with an acceptable safety profile supports a prophylactic epicardial pacing strategy for the patients undergoing TVR.


Asunto(s)
Estimulación Cardíaca Artificial , Marcapaso Artificial , Masculino , Humanos , Adulto , Persona de Mediana Edad , Anciano , Femenino , Válvula Tricúspide/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Marcapaso Artificial/efectos adversos
3.
Heart ; 109(12): 951-958, 2023 05 26.
Artículo en Inglés | MEDLINE | ID: mdl-36828623

RESUMEN

OBJECTIVES: The TRI-SCORE reliably predicts in-hospital mortality after isolated tricuspid valve surgery (ITVS) on native valve but has not been tested in the setting of redo interventions. We aimed to evaluate the predictive value of the TRI-SCORE for in-hospital mortality in patients with redo ITVS and to compare its accuracy with conventional surgical risk scores. METHODS: Using a mandatory administrative database, we identified all consecutive adult patients who underwent a redo ITVS at 12 French tertiary centres between 2007 and 2017. Baseline characteristics and outcomes were collected from chart review and surgical scores were calculated. RESULTS: We identified 70 patients who underwent a redo ITVS (54±15 years, 63% female). Prior intervention was a tricuspid valve repair in 51% and a replacement in 49%, and was combined with another surgery in 41%. A tricuspid valve replacement was performed in all patients for the redo surgery. Overall, in-hospital mortality and major postoperative complication rates were 10% and 34%, respectively. The TRI-SCORE was the only surgical risk score associated with in-hospital mortality (p=0.005). The area under the receiver operating characteristic curve for the TRI-SCORE was 0.83, much higher than for the logistic EuroSCORE (0.58) or EuroSCORE II (0.61). The TRI-SCORE was also associated with major postoperative complication rates and survival free of readmissions for heart failure. CONCLUSION: Redo ITVS was rarely performed and was associated with an overall high in-hospital mortality and morbidity, but hiding important individual disparities. The TRI-SCORE accurately predicted in-hospital mortality after redo ITVS and may guide clinical decision-making process (www.tri-score.com).


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Adulto , Humanos , Femenino , Masculino , Válvula Tricúspide/cirugía , Mortalidad Hospitalaria , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Factores de Riesgo , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Resultado del Tratamiento
4.
Ann Cardiol Angeiol (Paris) ; 71(4): 240-242, 2022 Oct.
Artículo en Francés | MEDLINE | ID: mdl-35940971

RESUMEN

INTRODUCTION: Prevotella species (i. e. P. intermedia, P. nigrescens, P. pallens, P. oris) are usually responsible for abscesses of head and neck spaces after dental procedures. P. intermedia - related infective endocarditis has never been reported. CASE REPORT: A 22-year-old man, with a history of aortic valve replacement 6 years ago, presented with fever and persistent retrosternal chest pain. An empirical antibiotic therapy was started on (cefotaxime, 2gx3 - gentamicin, 5mg/kilo). Five blood cultures were positive at Prevotella Intermedia. Metronidazole was introduced (500mg X 3 by day).The oro-pharyngeal spaces were normal. The evolution was marked by a hypotension, a third degree atrio-ventricular block, and a rapidly growing aortic root abscess complicated this case of Prevotella Intermedia infective endocarditis (IE). Aortic valve redux surgery was performed at day 5 of admission. Post-operative course was unremarkable. CONCLUSION: This first reported case of Prevotella Intermedia IE presented suggestive features of anaerobic IE as the patient developed both aortic-ring abscess, third degree atrio-ventricular block and hypotension.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Prótesis Valvulares Cardíacas , Hipotensión , Absceso , Adulto , Antibacterianos/uso terapéutico , Válvula Aórtica/cirugía , Cefotaxima , Endocarditis/cirugía , Endocarditis Bacteriana/diagnóstico , Endocarditis Bacteriana/tratamiento farmacológico , Endocarditis Bacteriana/etiología , Gentamicinas , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Hipotensión/complicaciones , Masculino , Metronidazol , Prevotella intermedia , Adulto Joven
5.
Eur J Nucl Med Mol Imaging ; 49(7): 2232-2241, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35247063

RESUMEN

PURPOSE: Characterization of malignant cardiac masses is usually performed with cardiac magnetic resonance (CMR) and staging with whole-body contrast-enhanced computed tomography (CECT). In this study, our objective was to evaluate the role of 18Fluor-fluorodeoxyglucose positron emission tomography (18F-FDG-PET) with CMR for both characterization and staging of cardiac masses. METHODS: Patients with cardiac masses who underwent CMR, CECT, and 18F-FDG-PET were retrospectively identified. For the characterization of cardiac masses, we calculated the respective performances of CMR alone, 18F-FDG-PET alone, and the combination of 18F-FDG-PET and CMR. For staging, we compared head-to-head the respective performances of 18F-FDG-PET and CECT. Histology served as gold standard for malignancy, and response to anticoagulation for thrombus. RESULTS: In a total of 28 patients (median age 60.5 years, 60.7% women), CMR accurately distinguished malignant from benign masses with sensitivity (Se) of 86.7%, specificity (Sp) of 100%, positive predictive value (PPV) of 100%, negative predictive value (NPV) of 86.7%, and accuracy of 92.9%. 18F-FDG-PET demonstrated 93.3% Se, 84.6% Sp, 87.5% PPV, 91.7% NPV, and 89.3% accuracy. Combining CMR with 18F-FDG-PET allowed to benefit from the high sensitivity of 18F-FDG-PET (92.9%) and the excellent specificity of CMR (100%) for malignant diseases. For staging, 18F-FDG-PET outperformed CECT on per-patient (66.7% vs 55.6% correct diagnosis, respectively), per-organ (10 vs 7 organs, respectively), and per-lesion basis (> 29 vs > 25 lesions, respectively). CONCLUSION: Combining 18F-FDG-PET with CMR improved the characterization of cardiac masses compared to each modality alone. Additionally, the diagnostic performance of 18F-FDG-PET was better than CECT for staging. This study suggests that the combination of CMR and 18F-FDG-PET is the most effective for the characterization of cardiac masses and the staging of these lesions.


Asunto(s)
Fluorodesoxiglucosa F18 , Radiofármacos , Femenino , Humanos , Espectroscopía de Resonancia Magnética , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Tomografía de Emisión de Positrones , Estudios Retrospectivos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos
6.
Eur Heart J ; 43(7): 654-662, 2022 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-34586392

RESUMEN

AIMS: Isolated tricuspid valve surgery (ITVS) is considered to be a high-risk procedure, but in-hospital mortality is markedly variable. This study sought to develop a dedicated risk score model to predict the outcome of patients after ITVS for severe tricuspid regurgitation (TR). METHODS AND RESULTS: All consecutive adult patients who underwent ITVS for severe non-congenital TR at 12 French centres between 2007 and 2017 were included. We identified 466 patients (60 ± 16 years, 49% female, functional TR in 49%). In-hospital mortality rate was 10%. We derived and internally validated a scoring system to predict in-hospital mortality using multivariable logistic regression and bootstrapping with 1000 re-samples. The final risk score ranged from 0 to 12 points and included eight parameters: age ≥70 years, New York Heart Association Class III-IV, right-sided heart failure signs, daily dose of furosemide ≥125 mg, glomerular filtration rate <30 mL/min, elevated bilirubin, left ventricular ejection fraction <60%, and moderate/severe right ventricular dysfunction. Tricuspid regurgitation mechanism was not an independent predictor of outcome. Observed and predicted in-hospital mortality rates increased from 0% to 60% and from 1% to 65%, respectively, as the score increased from 0 up to ≥9 points. Apparent and bias-corrected areas under the receiver operating characteristic curves were 0.81 and 0.75, respectively, much higher than the logistic EuroSCORE (0.67) or EuroSCORE II (0.63). CONCLUSION: We propose TRI-SCORE as a dedicated risk score model based on eight easy to ascertain parameters to inform patients and physicians regarding the risk of ITVS and guide the clinical decision-making process of patients with severe TR, especially as transcatheter therapies are emerging (www.tri-score.com).


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Adulto , Anciano , Femenino , Implantación de Prótesis de Válvulas Cardíacas/métodos , Mortalidad Hospitalaria , Humanos , Masculino , Estudios Retrospectivos , Factores de Riesgo , Volumen Sistólico , Resultado del Tratamiento , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico , Función Ventricular Izquierda
7.
J Nucl Cardiol ; 29(2): 528-534, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34085167

RESUMEN

AIM: The objective of this study was to evaluate the diagnostic performance of white blood cells (WBC)-SPECT imaging in patients with suspicion of prosthetic valve endocarditis (PVE) against intra-operative findings. METHODS: 36 consecutive patients who underwent cardiac surgery 30 days after WBC-SPECT imaging were identified retrospectively. Clinical, imaging, and biological results were collected from reports. WBC-SPECT results were classified as positive or negative and, if positive, the intensity of signal graded as intense or mild. Lesions observed during cardiac surgery were collected from surgeons' reports. RESULTS: The 20 patients with positive WBC-SPECT study had confirmed PVE intra-operatively. Patients with intense signal on WBC-SPECT had high prevalence of abscesses (83%) compared to patients with only mild signal (12%). The three patients with negative WBC-SPECT but confirmed PVE had longer duration of antibiotic treatment before imaging and had no perivalvular abscess. Sensitivity, specificity, positive predictive and negative values, and accuracy of WBC-SPECT were measured at 87%, 100%, 100%, 81%, and 92%, respectively. Addition of WBC-SPECT results to the modified Duke score helped re-classify correctly 25% of patients from possible to definite PVE. CONCLUSION: In patients with suspicion of PVE, WBC-SPECT imaging provides excellent diagnostic performance against intra-operative findings.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Prótesis Valvulares Cardíacas , Infecciones Relacionadas con Prótesis , Absceso/diagnóstico por imagen , Endocarditis/diagnóstico por imagen , Endocarditis Bacteriana/diagnóstico , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Leucocitos , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Estudios Retrospectivos , Tomografía Computarizada de Emisión de Fotón Único
8.
J Am Soc Echocardiogr ; 35(3): 278-286, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34861352

RESUMEN

BACKGROUND: Bicuspid aortic valve (BAV) is associated with an asymmetric (not circular) aortic root, resulting in variability in the aortic root diameter measurements obtained using different techniques. The objective of this study was to describe aortic root asymmetry, including its orientation in the thorax, in relation to the various phenotypes of BAV and its impact on aortic root diameter measurements obtained using transthoracic echocardiography. METHODS: Aortic root asymmetry, orientation of the largest root diameter, and orientation of the valve opening were studied using computed tomographic scans of patients with BAV without significant aortic valve dysfunction referred for evaluation of a thoracic aortic aneurysm. Eighty-five patients with BAV were evaluated; BAV with fusion of the left and the right coronary cusps (L-R BAV), with or without raphe (n = 63), was compared with BAV with fusion of the right coronary and noncoronary cusps (N-R BAV), with or without raphe (n = 22). RESULTS: Asymmetry of the aortic root and its orientation in the thorax can be predicted from BAV phenotype: orientation of the valve opening differed from orientation of the largest root diameter by nearly 75° in both groups. The angle of the largest root diameter with the reference sagittal plane was 64.3° in the L-R BAV group versus 143.1° in the N-R BAV group (P < .0001). Therefore, using the parasternal long-axis view on transthoracic echocardiography, in N-R BAV, the ultrasound beam is roughly parallel to the valve opening orientation and almost orthogonal to the maximum diameter of the root. On the contrary, in L-R BAV, the ultrasound beam is roughly perpendicular to the valve opening orientation and almost parallel to the maximum diameter of the root. Consequently, the parasternal long-axis view on transthoracic echocardiography significantly underestimates maximal aortic root diameter in N-R BAV and modestly underestimates root diameter in L-R BAV (-6.1 ± 0.96 vs -2.3 ± 0.47 mm, P = .0008). CONCLUSIONS: Aortic root morphology in patients with BAV can be predicted by BAV phenotype: the largest root diameter is roughly perpendicular to the orientation of the valve opening. Therefore, echocardiographic measurements according to present recommendations (parasternal long-axis view) underestimate maximal diameter in patients with N-R BAV.


Asunto(s)
Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Aorta , Válvula Aórtica/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Humanos , Fenotipo , Estudios Retrospectivos
9.
Eur Heart J ; 41(45): 4304-4317, 2020 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-32974668

RESUMEN

AIMS: The aim of this study was to identify determinants of in-hospital and mid-term outcomes after isolated tricuspid valve surgery (ITVS) and more specifically the impact of tricuspid regurgitation (TR) mechanism and clinical presentation. METHODS AND RESULTS: Among 5661 consecutive adult patients who underwent a tricuspid valve (TV) surgery at 12 French tertiary centres in 2007-2017 collected from a mandatory administrative database, we identified 466 patients (8% of all tricuspid surgeries) who underwent an ITVS. Most patients presented with advanced disease [47% in New York Heart Association (NYHA) III/IV, 57% with right-sided heart failure (HF) signs]. Tricuspid regurgitation was functional in 49% (22% with prior left-sided heart valve surgery and 27% isolated) and organic in 51% (infective endocarditis in 31% and other causes in 20%). In-hospital mortality and major complications rates were 10% and 31%, respectively. Rates of survival and survival free of HF readmission were 75% and 62% at 5 years. Patients with functional TR incurred a worse in-hospital mortality than those with organic TR (14% vs. 6%, P = 0.004), but presentation was more severe. Independent determinants of outcomes were NYHA Class III/IV [odd ratios (OR) = 2.7 (1.2-6.1), P = 0.01], moderate/severe right ventricular dysfunction [OR = 2.6 (1.2-5.8), P = 0.02], lower prothrombin time [OR = 0.98 (0.96-0.99), P = 0.008], and with borderline statistical significance, right-sided HF signs [OR = 2.4 (0.9-6.5), P = 0.06] while TR mechanism was not [OR = 0.7 (0.3-1.8), P = 0.88]. CONCLUSION: Isolated TV surgery was associated with high mortality and morbidity, both in hospital and during follow-up, predicted by the severity of the presentation but not by TR mechanism. Our results suggest that TV intervention should be performed earlier in the course of the disease.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Disfunción Ventricular Derecha , Adulto , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Estudios Retrospectivos , Resultado del Tratamiento , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/epidemiología , Insuficiencia de la Válvula Tricúspide/cirugía
10.
J Am Coll Cardiol ; 75(8): 843-853, 2020 03 03.
Artículo en Inglés | MEDLINE | ID: mdl-32130918

RESUMEN

BACKGROUND: Aortic risk has not been evaluated in patients with Marfan syndrome and documented pathogenic variants in the FBN1 gene. OBJECTIVES: This study sought to describe aortic risk in a population with Marfan syndrome with pathogenic variants in the FBN1 gene as a function of aortic root diameter. METHODS: Patients carrying an FBN1 pathogenic variant who visited our reference center at least twice were included, provided they had not undergone aortic surgery or had an aortic dissection before their first visit. Aortic events (aortic surgery or aortic dissection) and deaths were evaluated during the 2 years following each patient visit. The risk was calculated as the number of events divided by the number of years of follow-up. RESULTS: A total of 954 patients were included (54% women; mean age 23 years). During follow-up (9.1 years), 142 patients underwent prophylactic aortic root surgery, 5 experienced type A aortic dissection, and 12 died (noncardiovascular causes in 3, unknown etiology in 3, post-operative in 6). When aortic root diameter was <50 mm, risk for proven type A dissection (0.4 events/1,000 patient-years) and risk for possible aortic dissection (proven aortic dissection plus death of unknown cause, 0.7 events/1,000 patients-years) remained low in this population that was treated according to guidelines. Three type A aortic dissections occurred in this population during the 8,594 years of follow-up, including 1 in a patient with a tubular aortic diameter of 50 mm, but none in patients with a family history of aortic dissection. The risk for type B aortic dissection in the same population was 0.5 events/1,000 patient-years. CONCLUSIONS: In patients with FBN1 pathogenic variants who receive beta-blocker therapy and who limit strenuous exercise, aortic risk remains low when maximal aortic diameter is <50 mm. The risk of type B aortic dissection is close to the remaining risk of type A aortic dissection in this population, which underlines the global aortic risk.


Asunto(s)
Aorta/patología , Aneurisma de la Aorta/etiología , Disección Aórtica/etiología , Fibrilina-1/genética , Síndrome de Marfan/complicaciones , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Aorta/cirugía , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Síndrome de Marfan/mortalidad , Síndrome de Marfan/patología , Síndrome de Marfan/cirugía , Persona de Mediana Edad , Procedimientos Quirúrgicos Profilácticos , Medición de Riesgo , Adulto Joven
11.
Eur J Vasc Endovasc Surg ; 59(4): 577-585, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31865029

RESUMEN

OBJECTIVE: In Marfan syndrome (MFS) patients, endovascular repair carries a risk of aortic wall injury, which may result in retrograde aortic dissection, dilatation, or false aneurysm at the landing zones. It was hypothesised that potentially these complications may be avoided using modified practices. This study aimed to describe experience of a specific protocol for endovascular aortic repair in patients with MFS. METHODS: All MFS patients treated by aortic endovascular repair between February 2015 and August 2018 were included prospectively. The following rules were applied: (i) excluding stent grafts with bare stents and barbs, (ii) proximal landing in a pre-existing graft, or (iii) minimising proximal oversizing when landing in the proximal native aorta (<10%), and (iv) distal undersizing for chronic dissection cases. RESULTS: In eighteen patients (55% men, mean age: 47 ± 17 years), the index procedures were initial endovascular aortic repair (n = 10), elephant trunk completion (n = 6), and anastomotic pseudo-aneurysm after thoracic open repair (n = 2). The technical success rate was 100%. Proximal landing was in the native aorta in 11 patients (61%), with a mean proximal oversizing of 2.4 mm (8% oversized). Distal landing in the native aorta was performed in 16 cases (89%), with a mean distal undersizing of 8.9 mm (- 23%). No mortality, spinal cord ischaemia, stroke, or retrograde aortic dissection occurred post-operatively. One type 1b endoleak was observed. The mean follow up was 21.4 months. Aortic aneurysm related mortality was 5% (n = 1) and occurred after distal thoraco-abdominal surgery planned from the outset (prior to endovascular repair). Another patient presented a proximal landing zone complication with aortic enlargement. The mean maximum aortic diameter decreased significantly from 59 mm to 45 mm (p = .0005) after treatment. CONCLUSION: The specific protocol described in this study seems to optimise the results of endovascular aortic repair in MFS patients with significant aortic remodelling.


Asunto(s)
Aneurisma de la Aorta/cirugía , Disección Aórtica/cirugía , Síndrome de Marfan/cirugía , Adulto , Anciano , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Endofuga/etiología , Procedimientos Endovasculares/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad
12.
Arch Cardiovasc Dis ; 111(8-9): 528-533, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30030045

RESUMEN

BACKGROUND: With the emergence of transcatheter mitral valve replacement, it appears crucial to provide contemporary references with which this new technology can be compared. At our institution, transoesophageal echocardiography is systematically performed before discharge after surgical mitral valve replacement. AIM: To evaluate the rate and determinants of paravalvular regurgitation after surgical mitral valve replacement. METHODS: We collected medical history, indication, type of surgery and in-hospital outcome in all consecutive patients who underwent a mitral valve replacement in the past 2 years at our institution. Paravalvular regurgitation was assessed semiquantitatively using transoesophageal echocardiography before discharge. RESULTS: We enrolled 399 patients (mean age 61±16 years; 58% women; 27% with a history of cardiac surgery). Mitral valve replacement was performed mainly for rheumatic disease (44%). Most patients were severely symptomatic (70% in New York Heart Association class III/IV). A mechanical prosthesis was implanted in 60% and a bioprosthesis in 40%. In-hospital mortality was 10%. Transoesophageal echocardiography was performed in 310 patients (77%); the main reasons for not performing transoesophageal echocardiography were frailty (n=40, 10%), early death (n=19, 5%) and contraindication for transoesophageal echocardiography (n=10, 3%). The overall rate of paravalvular regurgitation was 8% (n=25); a grade ≥2 was observed in five patients (2%), and two patients had to be reoperated on. Mitral annular calcification was the main factor associated with paravalvular regurgitation (P=0.01). CONCLUSIONS: Surgical mitral valve replacement was associated with significant in-hospital mortality and morbidity. Using systematic transoesophageal echocardiography assessment, paravalvular regurgitation was not uncommon (8%), and was significantly linked to mitral annulus calcification. However, clinically significant leakage (≥grade 2) was rare (2%).


Asunto(s)
Ecocardiografía Transesofágica , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Cardiopatía Reumática/cirugía , Anciano , Calcinosis/diagnóstico por imagen , Calcinosis/mortalidad , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Paris/epidemiología , Valor Predictivo de las Pruebas , Prevalencia , Estudios Retrospectivos , Cardiopatía Reumática/diagnóstico por imagen , Cardiopatía Reumática/mortalidad , Cardiopatía Reumática/fisiopatología , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
13.
Eur Heart J ; 39(28): 2679-2689, 2018 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-29788044

RESUMEN

Aims: We analysed the early and long-term clinical and haemodynamic outcomes of balloon-expandable transcatheter mitral valve implantation (TMVI) in an experienced centre. Methods and results: All patients undergoing TMVI from July 2010 to July 2017 in our centre were prospectively included. Indication for TMVI relied on the judgement of the local heart team. Patients were followed at 1 month, 1 year, and yearly thereafter. A total of 91 patients underwent TMVI. The median age was 73 (57-81) years and 70% of patients were women. Patients were at high risk for surgery with a median EuroSCORE II of 9.6 (4.0-14.6) %. Indication for TMVI was bioprosthesis failure (valve-in-valve) in 37.3%, annuloplasty failure (valve-in-ring) in 33.0%, and severe mitral annulus calcification (MAC) in 29.7%. The transseptal approach was used in 92.3% of patients and balloon-expandable valves were used in all patients. Technical success was achieved in 84.6% of patients, one patient died during the procedure and haemodynamically significant left ventricular outflow tract obstruction occurred in three patients (3.3%). At 30 days, 7.7% of patients had died, without significant differences between groups, and a major stroke occurred in 2.2% of patients. The cumulative rates of all-cause mortality at 1-year and 2-year follow-up were 21.0% [95% confidence interval (CI) 9.9-38.8] and 35.7% (95% CI 19.2-56.5), respectively, with a higher late mortality in patients with MAC. The 2-year rates of re-intervention and valve thrombosis were 8.8% and 14.4%, respectively. At 6 months to 1 year, 68.9% of patients were in New York Heart Association Class I or II, and 90.7% of patients had mild or less mitral regurgitation. The mean transmitral gradient decreased from 9.3 ± 3.9 mmHg at baseline to 6.0 ± 2.3 mmHg at discharge (P < 0.001) without changes at 6-month to 1-year follow-up. Conclusion: Transcatheter mitral valve implantation using balloon-expandable valves in selected patients with bioprosthesis or annuloplasty failure or severe MAC was associated with a low rate of peri-procedural complications and acceptable long-term outcomes.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Hemodinámica , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento
14.
Arch Cardiovasc Dis ; 111(8-9): 480-486, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29223748

RESUMEN

BACKGROUND: Performance of tricuspid annuloplasty (TA) in patients undergoing mitral valve surgery is recommended based on the degree of tricuspid regurgitation and tricuspid annulus size, but is often underused. AIM: To evaluate the impact of combined TA on in-hospital outcome in patients undergoing mitral valve replacement (MVR). METHODS: We selected all consecutive patients who underwent MVR for native valve disease. Clinical, echocardiographic and in-hospital complications were obtained from chart review. RESULTS: We identified 287 patients (mean age 62±17 years; 44% men). Combined TA was performed in 165 patients (57%), who had more rheumatic disease (71% vs. 24%; P<0.0001) and mitral stenosis (55% vs. 22%; P<0.0001), but less endocarditis (4% vs. 31%; P<0.0001), were more often in atrial fibrillation (54% vs. 22%; P<0.0001), were more severely symptomatic (80% vs. 57%; P<0.0001), presented with a higher systolic pulmonary artery pressure (SPAP) (53±16 vs. 45±15mmHg; P=0.0002) and were less likely to have required emergency surgery (17% vs. 38%; P<0.0001). Despite this higher risk profile, in-hospital mortality was slightly lower (5% vs. 13%; P=0.02) and complication rates were similar (redo surgery 22% vs. 16% [P=0.18] and tamponade 20% vs. 15% [P=0.15]). After adjustment for age, sex, functional class, SPAP, emergency surgery and concomitant coronary artery bypass graft or aortic valve replacement surgery, combined TA was not associated with an increased rate of in-hospital death (P=0.08) or major complications (P=0.89). CONCLUSIONS: In a consecutive series of patients who underwent MVR, TA did not seem to have a negative impact on immediate outcome. Hence, additional performance of TA at the time of MVR should not be declined on the basis of an increased surgical risk.


Asunto(s)
Anuloplastia de la Válvula Cardíaca/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/cirugía , Anciano , Anuloplastia de la Válvula Cardíaca/mortalidad , Ecocardiografía Doppler , Ecocardiografía Transesofágica , Femenino , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Paris , Complicaciones Posoperatorias/etiología , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/mortalidad , Insuficiencia de la Válvula Tricúspide/fisiopatología
15.
EuroIntervention ; 13(15): e1771-e1773, 2018 02 02.
Artículo en Inglés | MEDLINE | ID: mdl-29131805

Asunto(s)
Válvula Aórtica/cirugía , Cateterismo Cardíaco , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Enfermedad de Hodgkin/radioterapia , Válvula Mitral/cirugía , Traumatismos por Radiación/cirugía , Anciano , Válvula Aórtica/fisiopatología , Válvula Aórtica/efectos de la radiación , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Femenino , Enfermedades de las Válvulas Cardíacas/etiología , Enfermedades de las Válvulas Cardíacas/mortalidad , Enfermedades de las Válvulas Cardíacas/fisiopatología , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Enfermedad de Hodgkin/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/fisiopatología , Válvula Mitral/efectos de la radiación , Complicaciones Posoperatorias/etiología , Traumatismos por Radiación/etiología , Traumatismos por Radiación/mortalidad , Traumatismos por Radiación/fisiopatología , Radioterapia/efectos adversos , Recuperación de la Función , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
16.
Arch Cardiovasc Dis ; 110(3): 196-201, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28214266
17.
EuroIntervention ; 12(15): e1849-e1856, 2017 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-27840324

RESUMEN

AIMS: The aim of this study was to evaluate the feasibility, safety and outcomes of TAVI performed via the suprasternal brachiocephalic approach in selected patients at high or prohibitive surgical risk who are not eligible for transfemoral or subclavian TAVI. METHODS AND RESULTS: From March 2014 to March 2016, 26 high-risk patients without transfemoral or subclavian access options were considered for TAVI via a suprasternal brachiocephalic approach. The feasibility of the suprasternal brachiocephalic approach was determined according to computed tomography findings. In 23 (88.4%) patients the procedure was performed as intended, whereas in three (11.5%) patients the approach was converted to a right carotid access. Both self-expanding (n=20, 76.9%) and balloon-expandable prostheses (n=6, 23.1%) were used. At 30 days, no patient had died; there was one major stroke (3.8%) and there were three major vascular access site-related complications (11.5%). After a median follow-up of 317 days (57-705), two patients had died, both from cardiovascular causes, and 19 out of 24 survivors (79.2%) were in New York Heart Association functional Class I or II. CONCLUSIONS: This single-centre case series suggests that TAVI using the suprasternal brachiocephalic approach is feasible in selected patients and may represent an additional alternative route in patients who are not eligible for other approaches.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/métodos , Femenino , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
18.
PLoS One ; 10(9): e0139122, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26422144

RESUMEN

BACKGROUND: Sternal Wound Infection (SWI) is a severe complication after cardiac surgery. Debridement associated with primary closure using Redon drains (RD) is an effective treatment, but data on RD management and antibiotic treatment are scarce. METHODS: We performed a single-center analysis of consecutive patients who were re-operated for SWI between 01/2009 and 12/2012. All patients underwent a closed drainage with RD (CDRD). Patients with endocarditis or those who died within the first 45 days were excluded from management analysis. RD fluid was cultured twice weekly. Variables recorded were clinical and biological data at SWI diagnosis, severity of SWI based on criteria for mediastinitis as defined by the Centers for Disease Control (CDC), antibiotic therapy, RD management and patient's outcome. RESULTS: 160 patients developed SWI, 102 (64%) fulfilled CDC criteria (CDC+) and 58 (36%) did not (CDC- SWI). Initial antibiotic treatment and surgical management were similar in CDC+ and CDC- SWI. Patients with CDC+ SWI had a longer duration of antibiotic therapy and a mortality rate of 17% as compared to 3% in patients with CDC- SWI (p = 0.025). Rates of superinfection (10% and 9%) and need for second reoperation (12% and 17%) were similar. Failure (death or need for another reoperation) was associated with female gender, higher EuroScore for prediction of operative mortality, and stay in the ICU. CONCLUSION: In patients with SWI, initial one-stage surgical debridement with CDRD is associated with favorable outcomes. CDC+ and CDC- SWI received essentially the same management, but CDC+ SWI has a more severe outcome.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/efectos adversos , Esternón/cirugía , Infección de la Herida Quirúrgica/etiología , Infección de la Herida Quirúrgica/terapia , Anciano , Antibacterianos/uso terapéutico , Drenaje , Femenino , Humanos , Masculino , Mediastinitis/tratamiento farmacológico , Mediastinitis/etiología , Mediastinitis/cirugía , Persona de Mediana Edad , Reoperación , Estudios Retrospectivos , Infección de la Herida Quirúrgica/tratamiento farmacológico , Infección de la Herida Quirúrgica/cirugía , Resultado del Tratamiento
19.
Circ Cardiovasc Imaging ; 8(7): e003241, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26156015

RESUMEN

BACKGROUND: Associated tricuspid annuloplasty is recommended during left-heart valve surgery when the tricuspid annulus (TA) is dilated but methodology for the measurement of TA size and thresholds for TA enlargement are not clearly defined. METHODS AND RESULTS: Measurement of the TA diameter (TAD) was prospectively performed using 2-dimensional transthoracic echocardiography (2D-TTE) in 282 patients in 4 different views (parasternal long axis, parasternal short axis, apical 4-chamber [A4C], and subcostal). TAD was also measured using 3D-transesophageal echocardiography in 183 patients (long axis), peroperatively in 120 patients who underwent a tricuspid valve surgery and using TTE (A4C) in 66 healthy volunteers. TAD was significantly different between the 4 2D-TTE views (3.85±0.58, 3.87±0.61, 4.02±0.69, and 3.92±0.65 cm, respectively; P<0.0001) but differences were small and the A4C was the most feasible (76%, 65%, 92%, and 73%, respectively; P<0.0001) and offered the highest reproducibility. TAD measured in A4C view was smaller than when measured by 3D-transesophageal echocardiography (3.90±0.63 versus 4.33±0.62 cm; P<0.0001) but correlation was excellent (r=0.84; P<0.0001) with a systematic 4-mm underestimation. In contrast, 2D-TTE measurements were significantly smaller and only modestly correlated to surgical measurements (4.11±0.61 versus 4.37±0.75 cm; P<0.0001; r=0.57; P<0.0001) which were poorly reproducible. In healthy volunteers, we suggested 42 mm or 23 mm/m(2) as pathological values for the TAD in A4C. CONCLUSIONS: Measurements of the TAD using 2D-TTE in A4C were highly feasible and reproducible and despite being systematically smaller than 3D measurements, accurately reflected the degree of TA enlargement as assessed using 3D transesophageal echocardiography. We proposed the thresholds that may be used in future prospective studies to demonstrate whether a preventive strategy would improve the outcome.


Asunto(s)
Ecocardiografía Doppler , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/diagnóstico por imagen , Adulto , Anciano , Anuloplastia de la Válvula Cardíaca , Estudios de Casos y Controles , Estudios de Factibilidad , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Selección de Paciente , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...