1.
BMC Anesthesiol ; 21(1): 183, 2021 06 29.
Artículo en Inglés | MEDLINE | ID: mdl-34187367

RESUMEN

BACKGROUND: Monitored Anesthesia Care (MAC) is an anesthetic service involving the titration of sedatives/analgesics to achieve varying levels of sedation while avoiding general anesthesia (GA) and airway instrumentation. The goal of our study was to determine the overall incidence of conversion from MAC to general anesthesia with airway instrumentation and elucidate reasons and risk factors for conversion. METHODS: In this retrospective observational study, all non-obstetric adult patients who received MAC from July 2002 to July 2015 at Mount Sinai Hospital were electronically screened for inclusion via a clinical database. Patient, procedure, anesthetic, and practitioner data were all collected and analyzed to generate descriptive analyses. Subsequent univariate and multivariate analyses were used to identify specific risk factors associated with conversion to GA. RESULTS: Overall, 0.50% (1097/219,061) of MAC cases were converted to GA. Approximately half of conversions were due to the patient's "intolerance" of MAC (with or without failed regional anesthesia), while the other half were due to physiologic derangements. Body mass index, male sex, American Society of Anesthesiologists Physical Status Classification, anesthesia team composition, and surgical specialty were all associated with risk of conversion to GA. CONCLUSIONS: This is one of the first and largest retrospective studies aimed at identifying reasons and risk factors associated with the conversion of MAC to GA. These findings may be used to help better anticipate or prevent these events.


Asunto(s)
Anestesia de Conducción/métodos , Anestesia General/métodos , Adulto , Anciano , Diseño de Equipo , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo
2.
J Vasc Surg ; 61(1): 203-16, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24095042

RESUMEN

After the creation of an autogenous lower extremity bypass graft, the vein must undergo a series of dynamic structural changes to stabilize the arterial hemodynamic forces. These changes, which are commonly referred to as remodeling, include an inflammatory response, the development of a neointima, matrix turnover, and cellular proliferation and apoptosis. The sum total of these processes results in dramatic alterations in the physical and biomechanical attributes of the arterialized vein. The most clinically obvious and easily measured of these is lumen remodeling of the graft. However, although somewhat less precise, wall thickness, matrix composition, and endothelial changes can be measured in vivo within the healing vein graft. Recent translational work has demonstrated the clinical relevance of remodeling as it relates to vein graft patency and the systemic factors influencing it. By correlating histologic and molecular changes in the vein, insights into potential therapeutic strategies to prevent bypass failure and areas for future investigation are explored.


Asunto(s)
Oclusión de Injerto Vascular/etiología , Isquemia/cirugía , Extremidad Inferior/irrigación sanguínea , Injerto Vascular/efectos adversos , Remodelación Vascular , Venas/trasplante , Animales , Oclusión de Injerto Vascular/metabolismo , Oclusión de Injerto Vascular/patología , Oclusión de Injerto Vascular/fisiopatología , Hemodinámica , Humanos , Hiperplasia , Isquemia/diagnóstico , Isquemia/fisiopatología , Neointima , Factores de Riesgo , Estrés Mecánico , Factores de Tiempo , Insuficiencia del Tratamiento , Injerto Vascular/métodos , Venas/metabolismo , Venas/patología , Venas/fisiopatología , Cicatrización de Heridas