Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
Europace ; 26(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38703375

RESUMEN

AIMS: Ablation of monomorphic ventricular tachycardia (MMVT) has been shown to reduce shock frequency and improve survival. We aimed to compare cause-specific risk factors for MMVT and polymorphic ventricular tachycardia (PVT)/ventricular fibrillation (VF) and to develop predictive models. METHODS AND RESULTS: The multicentre retrospective cohort study included 2668 patients (age 63.1 ± 13.0 years; 23% female; 78% white; 43% non-ischaemic cardiomyopathy; left ventricular ejection fraction 28.2 ± 11.1%). Cox models were adjusted for demographic characteristics, heart failure severity and treatment, device programming, and electrocardiogram metrics. Global electrical heterogeneity was measured by spatial QRS-T angle (QRSTa), spatial ventricular gradient elevation (SVGel), azimuth, magnitude (SVGmag), and sum absolute QRST integral (SAIQRST). We compared the out-of-sample performance of the lasso and elastic net for Cox proportional hazards and the Fine-Gray competing risk model. During a median follow-up of 4 years, 359 patients experienced their first sustained MMVT with appropriate implantable cardioverter-defibrillator (ICD) therapy, and 129 patients had their first PVT/VF with appropriate ICD shock. The risk of MMVT was associated with wider QRSTa [hazard ratio (HR) 1.16; 95% confidence interval (CI) 1.01-1.34], larger SVGel (HR 1.17; 95% CI 1.05-1.30), and smaller SVGmag (HR 0.74; 95% CI 0.63-0.86) and SAIQRST (HR 0.84; 95% CI 0.71-0.99). The best-performing 3-year competing risk Fine-Gray model for MMVT [time-dependent area under the receiver operating characteristic curve (ROC(t)AUC) 0.728; 95% CI 0.668-0.788] identified high-risk (> 50%) patients with 75% sensitivity and 65% specificity, and PVT/VF prediction model had ROC(t)AUC 0.915 (95% CI 0.868-0.962), both satisfactory calibration. CONCLUSION: We developed and validated models to predict the competing risks of MMVT or PVT/VF that could inform procedural planning and future randomized controlled trials of prophylactic ventricular tachycardia ablation. CLINICAL TRIAL REGISTRATION: URL:www.clinicaltrials.gov Unique identifier:NCT03210883.


Asunto(s)
Desfibriladores Implantables , Prevención Primaria , Taquicardia Ventricular , Fibrilación Ventricular , Humanos , Femenino , Masculino , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/prevención & control , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Persona de Mediana Edad , Estudios Retrospectivos , Prevención Primaria/métodos , Factores de Riesgo , Medición de Riesgo , Anciano , Fibrilación Ventricular/prevención & control , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/fisiopatología , Fibrilación Ventricular/terapia , Resultado del Tratamiento , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/efectos adversos , Electrocardiografía , Ablación por Catéter , Factores de Tiempo , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/etiología
2.
Pacing Clin Electrophysiol ; 47(5): 642-649, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38556540

RESUMEN

BACKGROUND: Remote monitoring (RM) of pacemakers and implantable cardioverter-defibrillators (ICDs) is a Class 1, Level of Evidence A recommendation because of its multitude of clinical benefits. However, RM adherence rates are suboptimal, precluding patients from achieving these benefits. There is a need for direct-to-patient efforts to improve adherence. METHODS: In this national randomized, controlled trial conducted in the Veterans Health Administration (VHA), 2120 patients with a pacemaker or ICD who had not sent an RM transmission for ≥1 year (and usually ≥3 years) while under VHA care for their device were randomly assigned to be mailed a postcard (n = 1076) or a detailed letter (n = 1044). The postcard described what RM does and its key benefits (reduced mortality and fewer in-person visits). The letter provided a similar message but included more details about RM benefits and the process. The primary outcome was an RM transmission sent within 90 days of mailing, and a secondary outcome was an RM transmission sent within 365 days. RESULTS: The primary outcome was achieved in 121 (11.3%) in the postcard and 96 patients (9.2%) in the letter group (p = .12). The secondary outcome was achieved in 266 (24.7%) and 239 (22.9%), respectively (p = .32). CONCLUSIONS: This randomized trial showed no significant difference in the proportion of chronically non-adherent patients who sent an RM transmission after receiving a low-cost postcard or a detailed, higher-cost letter encouraging their participation in RM. However, as only a minority of patients responded to either, further work is needed to engage patients in the life-saving benefits of RM.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Veteranos , Humanos , Masculino , Femenino , Anciano , Estados Unidos , Cooperación del Paciente/estadística & datos numéricos , Persona de Mediana Edad , Correspondencia como Asunto
3.
J Am Heart Assoc ; 13(5): e032890, 2024 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-38390808

RESUMEN

BACKGROUND: Implantable loop recorders (ILRs) are increasingly placed for arrhythmia detection. However, historically, ≈75% of ILR alerts are false positives, requiring significant time and effort for adjudication. The LINQII and LUX-Dx are remotely reprogrammable ILRs with dual-stage algorithms using artificial intelligence to reduce false positives, but their utility in routine clinical practice has not been studied. METHODS AND RESULTS: We identified patients with the LINQII and LUX-Dx who were monitored by the Veterans Affairs National Cardiac Device Surveillance Program between March and June 2022. ILR programming was customized on the basis of implant indication. All alerts and every 90-day scheduled transmissions were manually reviewed. ILRs were remotely reprogrammed, as appropriate, after false-positive alerts or 2 consecutive same-type alerts, unless there was ongoing clinical need for that alert. Outcomes were total number of transmissions and false positives. We performed medical record review to determine if patients experienced any adverse clinical events, including hospitalization and mortality. Among 117 LINQII patients, there were 239 total alerts, 43 (18.0%) of which were false positives. Among 105 LUX-Dx patients, there were 300 total alerts, 115 (38.3%) of which were false positives. LINQIIs were reprogrammed 22 times, resulting in a decrease in median alerts/day from 0.13 to 0.03. LUX-Dx ILRs were reprogrammed 52 times, resulting in a decrease from 0.15 to 0.01 median alerts/day. There were no adverse clinical events that could have been identified by superior or earlier arrhythmia detection. CONCLUSIONS: ILRs with artificial intelligence algorithms and remote reprogramming ability are associated with reduced alert burden because of higher true-positive rates than prior ILRs, without missing potentially consequential arrhythmias.


Asunto(s)
Arritmias Cardíacas , Inteligencia Artificial , Humanos , Arritmias Cardíacas/diagnóstico , Prótesis e Implantes , Algoritmos , Diagnóstico Precoz , Electrocardiografía Ambulatoria/métodos
4.
J Gen Intern Med ; 39(Suppl 1): 87-96, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38252247

RESUMEN

BACKGROUND: Remote monitoring (RM) of pacemakers and implantable cardioverter-defibrillators (ICDs) reduces morbidity and mortality. However, many patients are not adherent to RM. OBJECTIVE: To test the effect of informational postcards on RM adherence. DESIGN/PATIENTS: Stepped-wedge randomized controlled trial among Veterans with pacemakers and ICDs. INTERVENTION: In wave 1, Veterans who had sent at least 1 transmission within the past 2 years but had become non-adherent were randomly assigned to receive a postcard or no postcard. Those receiving postcards were randomized to 1 of 2 messages: (1) a"warning" postcard describing risks of non-adherence or (2) an "encouraging" postcard describing benefits of adherence. In wave 2, Veterans who had either not received a postcard in wave 1 or had since become non-adherent were mailed a postcard (again, randomized to 1 of 2 messages). Patients who did not send an RM transmission within 1 month were mailed a second, identical postcard. MAIN MEASURES: Transmission within 70 days. KEY RESULTS: Overall, 6351 Veterans were included. In waves 1 and 2, postcards were mailed to 5657 Veterans (2821 "warning" messages and 2836 "encouraging" messages). Wave 1 included 2178 Veterans as controls (i.e., not mailed a postcard), some of whom received a postcard in wave 2 if they remained non-adherent. In wave 2, 3473 postcards were sent. Of the 5657 patients mailed a postcard, 2756 (48.7%) sent an RM transmission within 70 days, compared to 530 (24.3%) of 2178 controls (absolute difference 24.4%, 95% confidence interval [CI] 22.2%, 26.6%). Of those who sent a transmission, 71.8% did so after the first postcard. Transmission rates at 70 days did not significantly differ between "warning" and "encouraging" messages (odds ratio 1.04, 95% CI 0.92, 1.18). CONCLUSIONS: Informational postcards led to a 24.4% absolute increase in adherence at 70 days among Veterans with pacemakers and ICDs who were non-adherent to RM.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Veteranos , Humanos
6.
JMIR Cardio ; 7: e50973, 2023 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-37988153

RESUMEN

BACKGROUND: The Heart Rhythm Society strongly recommends remote monitoring (RM) of cardiovascular implantable electronic devices (CIEDs) because of the clinical outcome benefits to patients. However, many patients do not adhere to RM and, thus, do not achieve these benefits. There has been limited study of patient-level barriers and facilitators to RM adherence; understanding patient perspectives is essential to developing solutions to improve adherence. OBJECTIVE: We sought to identify barriers and facilitators associated with adherence to RM among veterans with CIEDs followed by the Veterans Health Administration. METHODS: We interviewed 40 veterans with CIEDs regarding their experiences with RM. Veterans were stratified into 3 groups based on their adherence to scheduled RM transmissions over the past 2 years: 6 fully adherent (≥95%), 25 partially adherent (≥65% but <95%), and 9 nonadherent (<65%). As the focus was to understand challenges with RM adherence, partially adherent and nonadherent veterans were preferentially weighted for selection. Veterans were mailed a letter stating they would be called to understand their experiences and perspectives of RM and possible barriers, and then contacted beginning 1 week after the letter was mailed. Interviews were structured (some questions allowing for open-ended responses to dive deeper into themes) and focused on 4 predetermined domains: knowledge of RM, satisfaction with RM, reasons for nonadherence, and preferences for health care engagement. RESULTS: Of the 44 veterans contacted, 40 (91%) agreed to participate. The mean veteran age was 75.3 (SD 7.6) years, and 98% (39/40) were men. Veterans had been implanted with their current CIED for an average of 4.4 (SD 2.8) years. A total of 58% (23/40) of veterans recalled a discussion of home monitoring, and 45% (18/40) reported a good understanding of RM; however, when asked to describe RM, their understanding was sometimes incomplete or not correct. Among the 31 fully or partially adherent veterans, nearly all were satisfied with RM. Approximately one-third recalled ever being told the results of a remote transmission. Among partially or nonadherent veterans, only one-fourth reported being contacted by a Department of Veterans Affairs health care professional regarding not having sent a remote transmission; among those who had troubleshooted to ensure they could send remote transmissions, they often relied on the CIED manufacturer for help (this experience was nearly always positive). Most nonadherent veterans felt more comfortable engaging in RM if they received more information or education. Most veterans were interested in being notified of a successful remote transmission and learning the results of their remote transmissions. CONCLUSIONS: Veterans with CIEDs often had limited knowledge about RM and did not recall being contacted about nonadherence. When they were contacted and troubleshooted, the experience was positive. These findings provide opportunities to optimize strategies for educating and engaging patients in RM.

8.
J Innov Card Rhythm Manag ; 14(7): 5499-5503, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37492696

RESUMEN

Radiofrequency (RF) ablation can be a source of electromagnetic interference (EMI) for cardiovascular implantable electronic devices (CIEDs). The response of CIEDs to this type of EMI can be variable and unpredictable. We report a case with an uncommon response where there was a failure to deliver pacing pulses to both atrial and ventricular pacing leads during RF ablation close to the atrial lead even when the pacemaker was set to pace asynchronously. We also explain the mechanism behind this unusual pacemaker response.

10.
J Interv Card Electrophysiol ; 66(7): 1679-1691, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36737506

RESUMEN

BACKGROUND: Implantable cardioverter defibrillators (ICDs) are typically programed with both ventricular tachycardia (VT) and ventricular fibrillation (VF) treatment zones. Biotronik and Abbott ICDs do not increment the VT counter when the tachycardia accelerates to the VF zone, which could result in a prolonged delay in tachycardia detection. METHODS: Patients with Biotronik and Abbott ICDs receiving care at Veterans Affairs facilities in Northern California were identified. Patient information and device tracings for patients with any ICD therapies were examined to assess for possible delayed tachycardia detection. RESULTS: Among 52 patients with Biotronik ICDs, 8 (15%) experienced appropriate ICD therapy over a median follow-up of 29 months. Among 68 patients with Abbott ICDs, 26 (38%) experienced appropriate ICD therapy over a median follow-up of 83 months. Three of the patients with Biotronik ICDs who received appropriate therapy experienced a delay in VT/VF detection due to the tachycardia rate oscillating between the VT and VF treatment zones (longest 31.2 s on detection), compared with four of the patients with Abbott ICDs (longest 4.1 s on the detection and 8 s on redetect). One of the patients with a Biotronik ICD experienced recurrent syncope associated with delayed detection and another died on the day of delayed detection. One of the patients with an Abbott ICD experienced syncope. CONCLUSIONS: Because contemporary Biotronik and Abbott ICDs freeze the VT counters when tachycardia is in the VF zone, ICD therapies can be markedly delayed when the tachycardia oscillates between the VT and VF zone.


Asunto(s)
Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Desfibriladores Implantables/efectos adversos , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/terapia , Fibrilación Ventricular/etiología , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Taquicardia Ventricular/etiología , Cardioversión Eléctrica/efectos adversos , Síncope/etiología
12.
Heart Rhythm ; 20(4): 512-519, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36586706

RESUMEN

BACKGROUND: Current methods to identify cardiovascular implantable electronic device lead failure include postapproval studies, which may be limited in scope, participant numbers, and attrition; studies relying on administrative codes, which lack specificity; and voluntary adverse event reporting, which cannot determine incidence or attribution to the lead. OBJECTIVE: The purpose of this study was to determine whether adjudicated remote monitoring (RM) data can address these limitations and augment lead safety evaluation. METHODS: Among 48,191 actively monitored patients with a cardiovascular implantable electronic device, we identified RM transmissions signifying incident lead abnormalities and, separately, identified all leads abandoned or extracted between April 1, 2019, and April 1, 2021. We queried electronic health record and Medicare fee-for-service claims data to determine whether patients had administrative codes for lead failure. We verified lead failure through manual electronic health record review. RESULTS: Of the 48,191 patients, 1170 (2.4%) had incident lead abnormalities detected by RM. Of these, 409 patients had administrative codes for lead failure, and 233 of these 409 patients (57.0%) had structural lead failure verified through chart review. Of the 761 patients without administrative codes, 167 (21.9%) had structural lead failure verified through chart review. Thus, 400 patients with RM transmissions suggestive of lead abnormalities (34.2%) had structural lead failure. In addition, 200 patients without preceding abnormal RM transmissions had leads abandoned or extracted for structural failure, making the total lead failure cohort 600 patients (66.7% with RM abnormalities, 33.3% without). Patients with isolated right atrial or left ventricular lead failure were less likely to have lead replacement and administrative codes reflective of lead failure. CONCLUSION: RM may strengthen real-world assessment of lead failure, particularly for leads where patients do not undergo replacement.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Anciano , Humanos , Estados Unidos/epidemiología , Desfibriladores Implantables/efectos adversos , Medicare , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia , Monitoreo Fisiológico/métodos
13.
Heart Rhythm O2 ; 4(12): 794-804, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38204458

RESUMEN

Background: Remote monitoring (RM) of patients with cardiovascular implantable electronic devices (CIEDs) (pacemakers and implantable cardioverter-defibrillators) has a Class 1, Level of Evidence A Heart Rhythm Society recommendation. Yet RM adherence varies widely across settings, and factors associated with variation are not understood. Objective: The purpose of this study was to identify strategies for supporting RM across Veterans Health Administration (VHA) facilities. Methods: In a national evaluation, we surveyed and interviewed 27 nurses, medical instrument technicians, and advanced practice providers across 26 VHA facilities (following approximately 15,000 CIED patients). Participants were selected based on overall patient adherence by facility, which ranged from 46%-96%. Questions covered RM adherence strategies, manufacturer resources, organizational characteristics, and workflows for optimizing adherence. Results: All clinicians reported that RM adherence was extremely important (53.8%), very important (34.6%), or important (11.5%) for improving patient outcomes. High performing facilities prioritized consistent patient education about RM and evaluated nonadherence using dashboards and manufacturer web sites. High performing facilities instituted clear standard operating procedures that defined staff responsibilities and facilitated efficient contact with nonadherent patients and then family members by phone and then mail. Clinicians based at high performing facilities spent twice as many hours per week (9.1) on average managing RM adherence compared to other facilities (4.5). Effective communication (internally and with non-VHA care partners) and use of CIED manufacturer resources were essential. Facilities that were not high performing rarely used these strategies. Conclusion: Clinicians can support high RM adherence by emphasizing patient education, regularly assessing and addressing nonadherence using staff protocols, and engaging CIED manufacturers.

14.
JACC Clin Electrophysiol ; 8(6): 754-762, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35738852

RESUMEN

BACKGROUND: The RAID (Ranolazine Implantable Cardioverter-Defibrillator) randomized placebo-controlled trial showed that ranolazine treatment was associated with reduction in recurrent ventricular tachycardia (VT) requiring appropriate implantable cardioverter-defibrillator (ICD) therapy. OBJECTIVES: This study aimed to identify groups of patients in whom ranolazine treatment would result in the highest reduction of ventricular tachyarrhythmia (VTA) burden. METHODS: Andersen-Gill analyses were performed to identify variables associated with risk for VTA burden among 1,012 patients enrolled in RAID. The primary endpoint was VTA burden defined as VTA episodes requiring appropriate treatment. RESULTS: Multivariate analysis identified 7 factors associated with increased VTA burden: history of VTA, age ≥65 years, New York Heart Association functional class ≥III, QRS complex (≥130 ms), low ejection fraction (<30%), atrial fibrillation (AF), and concomitant antiarrhythmic drug (AAD) therapy. The effect of ranolazine on VTA burden was seen among patients without concomitant AAD therapy (HR [HR]: 0.68; 95% CI: 0.55-0.84; P < 0.001), whereas no effect was seen among those who are concomitantly treated with other AADs (HR: 1.33; 95% CI: 0.90-1.96; P = 0.16); P = 0.003 for interaction. In patients with cardiac resynchronization therapy (CRT) ICDs, ranolazine treatment was associated with a 36% risk reduction for VTA recurrence (HR: 0.64; 95% CI: 0.47-0.86; P < 0.001), whereas among patients with ICDs without CRT no significant effect was noted (HR: 0.94; 95% CI: 0.74-1.18; P = 0.57); P = 0.047 for interaction. CONCLUSIONS: In patients with high risk for VTA, ranolazine is effective in reducing VTA burden, with significantly greater effect in CRT-treated patients, those without AF, and those not treated with concomitant AADs. In patients already on AADs or those with AF, the addition of ranolazine did not affect VTA burden. (Ranolazine Implantable Cardioverter-Defibrillator Trial [RAID]; NCT01215253).


Asunto(s)
Desfibriladores Implantables , Ranolazina , Taquicardia Ventricular , Anciano , Humanos , Ranolazina/uso terapéutico , Taquicardia Ventricular/prevención & control
15.
Heart Rhythm ; 19(9): 1499-1507, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35500792

RESUMEN

BACKGROUND: Professional societies strongly recommend remote monitoring (RM) of all cardiac implantable electronic devices, and higher RM adherence is associated with improved patient outcomes. However, adherence with RM is suboptimal. OBJECTIVE: The purpose of this study was to better understand factors associated with RM adherence. METHODS: We linked RM data from the Veterans Affairs National Cardiac Device Surveillance Program to clinical data for patients monitored between October 25, 2018, and October 24, 2020. RM adherence was defined as the percentage of days covered by an RM transmission during the study period. Patients were classified into 3 categories: complete (100% of days covered by an RM transmission), intermediate (above median in patients with <100% adherence), and low (below median in patients with <100% adherence) adherence. We used multivariable logistic regression to examine patient, device, and facility characteristics associated with adherence. RESULTS: In 52,574 patients, average RM adherence was 71.9%. Only 30.9% (16,224) of patients had complete RM adherence. Black or African American patients had a lower odds of complete RM adherence than white patients (odds ratio 0.88; 95% confidence interval 0.82-0.94), and Hispanic or Latino patients had a lower odds of complete RM adherence (odds ratio 0.79; 95% confidence interval 0.70-0.89) than non-Hispanic or Latino patients. Dementia, depression, and posttraumatic stress disorder were associated with a lower odds of RM adherence. CONCLUSION: There are significant disparities in RM adherence by race, ethnicity, and neuropsychiatric comorbidities. These findings can inform strategies to improve health equity and ensure that all patients with cardiac implantable electronic devices receive the evidence-based clinical benefits of RM.


Asunto(s)
Desfibriladores Implantables , Electrónica , Humanos , Monitoreo Fisiológico , Tecnología de Sensores Remotos
16.
Am Heart J Plus ; 192022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37886349

RESUMEN

Background: Implantable cardioverter-defibrillators (ICDs) reduce the risk of sudden cardiac death among patients with persistently reduced (≤35 %) left ventricular ejection fraction (LVEF) at least 40 days following acute myocardial infarction (AMI). Few prior studies have used LVEF measured after the 40-day waiting period to examine primary prevention ICD placement. Methods: We sought to determine factors associated with ICD placement among patients who met LVEF criteria post-MI within a large integrated health care system in the U.S by conducting a retrospective cohort study of Veteran patients hospitalized for AMI from 2004 to 2017 who had documented LVEF ≤35 % from echocardiograms performed between 40 and 455 (90 days +1 year) days post-MI. We used multivariable logistic regression to examine factors associated with ICD placement. Results: Of 12,893 patients with LVEF ≤35 % at least 40 days post-MI, 2176 (16.9 %) received an ICD between 91- and 455-days post-MI. Younger age, fewer comorbidities, revascularization with PCI, and greater use of GDMT were associated with increased odds of receiving an ICD. However, half of patients treated with a beta-blocker, ACE inhibitor or angiotensin receptor blocker, and mineralocorticoid receptor antagonist prior to LVEF assessment did not receive an ICD. Eligible Black patients were less likely (odds ratio 0.80, 95 % confidence interval 0.69-0.92) to receive an ICD than White patients. Conclusion: Many factors affect ICD placement among Veteran patients with a confirmed LVEF ≤35 % at least 40 days post-MI. Greater understanding of factors influencing ICD placement would help clinicians ensure guideline-concordant care.

17.
Clin Nurs Res ; 31(4): 588-597, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34362264

RESUMEN

To describe health related quality of life (HRQOL) and symptoms in the SPIRIT trial and determine effects of implantable cardioverter defibrillator (ICD) shocks on HRQOL over 24 months. Ninety participants aged 66 ± 10 years, 96% men, 75% with NYHA class II, with an ICD were randomized to spironolactone 25 mg (N = 44) or placebo (N = 46). HRQOL was measured every 6 months for 24 months using: Patient Concerns Assessment (PCA), Short Form Health Survey-Veterans Version (SF-36V), and Kansas City Cardiomyopathy Questionnaire (KCCQ). Linear mixed modeling compared changes in HRQOL over-time and ANCOVA compared HRQOL between those getting an ICD shock or not. Over 24-months, there were no differences in HRQOL between the spironolactone versus placebo groups. Those with at least one ICD shock reported significantly lower HRQOL and more symptoms at 6- and 24-months. Patients receiving one or more ICD shocks reported significant reductions in HRQOL and higher symptoms.


Asunto(s)
Desfibriladores Implantables , Calidad de Vida , Femenino , Humanos , Masculino , Espironolactona/uso terapéutico
18.
Heart Rhythm O2 ; 2(4): 374-381, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34430943

RESUMEN

BACKGROUND: Adaptive cardiac resynchronization therapy (aCRT) is known to have clinical benefits over conventional CRT, but the mechanisms are unclear. OBJECTIVE: Compare effects of aCRT and conventional CRT on electrical dyssynchrony. METHODS: A prospective, double-blind, 1:1 parallel-group assignment randomized controlled trial in patients receiving CRT for routine clinical indications. Participants underwent cardiac computed tomography and 128-electrode body surface mapping. The primary outcome was change in electrical dyssynchrony measured on the epicardial surface using noninvasive electrocardiographic imaging before and 6 months post-CRT. Ventricular electrical uncoupling (VEU) was calculated as the difference between the mean left ventricular (LV) and right ventricular (RV) activation times. An electrical dyssynchrony index (EDI) was computed as the standard deviation of local epicardial activation times. RESULTS: We randomized 27 participants (aged 64 ± 12 years; 34% female; 53% ischemic cardiomyopathy; LV ejection fraction 28% ± 8%; QRS duration 155 ± 21 ms; typical left bundle branch block [LBBB] in 13%) to conventional CRT (n = 15) vs aCRT (n = 12). In atypical LBBB (n = 11; 41%) with S waves in V5-V6, conduction block occurred in the anterior RV, as opposed to the interventricular groove in strict LBBB. As compared to baseline, VEU reduced post-CRT in the aCRT (median reduction 18.9 [interquartile range 4.3-29.2 ms; P = .034]), but not in the conventional CRT (21.4 [-30.0 to 49.9 ms; P = .525]) group. There were no differences in the degree of change in VEU and EDI indices between treatment groups. CONCLUSION: The effect of aCRT and conventional CRT on electrical dyssynchrony is largely similar, but only aCRT harmoniously reduced interventricular dyssynchrony by reducing RV uncoupling.

19.
Contemp Clin Trials ; 108: 106505, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34265457

RESUMEN

The cost of conducting clinical trials is continuously increasing and is driven in large part by the time and resources required to activate trials and reach accrual targets. The impact of low enrollment in a clinical trial can negatively affect the validity of study results and delay its generalizability to the broader population. Quality is a multidimensional concept which could relate to the design, conduct, and analysis of a trial, its clinical relevance, protection/safety of study participants, or quality of reporting. Furthermore, the quality of controlled trials is of obvious relevance to systematic reviews and if the "raw material" or "data" is flawed then the conclusions of systematic reviews cannot be trusted. To date, the literature surrounding the establishment of standardized study enrollment and quality metrics to assess site performance in clinical trial consortiums is scarce. The lack of these metrics presents challenges to study site teams, sponsors, and other clinical research enterprise key stakeholders for adequately monitoring and evaluating study site performance as it relates to fulfilling trial enrollment and quality goals. The Department of Veterans Affairs (VA) Cooperative Studies Program (CSP) Network of Dedicated Enrollment Sites (NODES) undertook an effort to determine the feasibility of establishing and implementing standardized study enrollment and quality metrics for a clinical research consortium (NODES) as a tool to evaluate its performance. In this manuscript, we describe the development and implementation of standardized study enrollment and quality metrics to assess site performance across studies in our clinical research consortium.


Asunto(s)
Benchmarking , United States Department of Veterans Affairs , Ensayos Clínicos como Asunto , Atención a la Salud , Humanos , Revisiones Sistemáticas como Asunto , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...