2.
Biomed Phys Eng Express ; 10(4)2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38640907

RESUMEN

Cardiac electrical changes associated with ischemic heart disease (IHD) are subtle and could be detected even in rest condition in magnetocardiography (MCG) which measures weak cardiac magnetic fields. Cardiac features that are derived from MCG recorded from multiple locations on the chest of subjects and some conventional time domain indices are widely used in Machine learning (ML) classifiers to objectively distinguish IHD and control subjects. Most of the earlier studies have employed features that are derived from signal-averaged cardiac beats and have ignored inter-beat information. The present study demonstrates the utility of beat-by-beat features to be useful in classifying IHD subjects (n = 23) and healthy controls (n = 75) in 37-channel MCG data taken under rest condition of subjects. The study reveals the importance of three features (out of eight measured features) namely, the field map angle (FMA) computed from magnetic field map, beat-by-beat variations of alpha angle in the ST-T region and T wave magnitude variations in yielding a better classification accuracy (92.7 %) against that achieved by conventional features (81 %). Further, beat-by-beat features are also found to augment the accuracy in classifying myocardial infarction (MI) Versus control subjects in two public ECG databases (92 % from 88 % and 94 % from 77 %). These demonstrations summarily suggest the importance of beat-by-beat features in clinical diagnosis of ischemia.


Asunto(s)
Aprendizaje Automático , Magnetocardiografía , Isquemia Miocárdica , Humanos , Magnetocardiografía/métodos , Isquemia Miocárdica/fisiopatología , Isquemia Miocárdica/diagnóstico , Masculino , Femenino , Persona de Mediana Edad , Adulto , Estudios de Casos y Controles , Procesamiento de Señales Asistido por Computador , Algoritmos , Electrocardiografía/métodos , Anciano , Frecuencia Cardíaca/fisiología , Corazón/fisiopatología , Reproducibilidad de los Resultados
3.
Indian Pacing Electrophysiol J ; 24(2): 119-121, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38355014

RESUMEN

Lead reversals are a common cause of electrocardiographic abnormality, which can lead to a false diagnosis like chamber enlargement, myocardial ischemia or infarction. Isolated limb lead reversals and chest lead reversals are common in clinical practice. This article reports a rare case where multiple limb and chest leads were reversed due to the reversal of cables leading to a false diagnosis of myocardial ischemia.

4.
Biomed Phys Eng Express ; 10(2)2024 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-38277702

RESUMEN

Background. Magnetocardiography (MCG) is a non-invasive and non-contact technique that measures weak magnetic fields generated by the heart. It is highly effective in the diagnosis of heart abnormalities. Multichannel MCG provides detailed spatio-temporal information of the measured magnetic fields. While multichannel MCG systems are costly, usage of the optimal number of measurement channels to characterize cardiac magnetic fields without any appreciable loss of signal information would be economically beneficial and promote the widespread use of MCG technology.Methods. An optimization method based on the sequential selection approach is used to choose channels containing the maximum signal information while avoiding redundancy. The study comprised 40 healthy individuals, along with two subjects having ischemic heart disease and one subject with premature ventricular contraction. MCG measured using a 37 channel MCG system. After revisiting the existing methods of optimization, the mean error and correlation of the optimal set of measurement channels with those of all 37 channels are evaluated for different sets, and it has been found that 18 channels are adequate.Results. The chosen 18 optimal channels exhibited a strong correlation (0.99 ± 0.006) between the original and reconstructed magnetic field maps for a cardiac cycle in healthy subjects. The root mean square error is 0.295 pT, indicating minimal deviation.Conclusion. This selection method provides an efficient approach for choosing MCG, which could be used for minimizing the number of channels as well as in practical unforeseen measurement conditions where few channels are noisy during the measurement.


Asunto(s)
Magnetocardiografía , Complejos Prematuros Ventriculares , Humanos , Magnetocardiografía/métodos , Análisis Costo-Beneficio , Corazón , Electrocardiografía
5.
Pacing Clin Electrophysiol ; 47(2): 239-241, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38264970

RESUMEN

A 51-year-old female with congenitally corrected transposition of great arteries (CCTGA), situs solitus, dextrocardia, atrial septal defect and persistent left superior vena cava underwent electrophysiology study for recurrent palpitations with documented narrow complex, short RP tachycardia. With a catheter in the region of the anterior mitral annulus, a His signal was recorded and HV interval was 35 msec. Tachycardia was induced with a ventricular extrastimulus. During the tachycardia there was 1:1 ventriculo-atrial conduction and central atrial activation with a VA interval of 20 msec. The recorded His signal could be seen after the QRS. What is the mechanism of the tachycardia?


Asunto(s)
Transposición de los Grandes Vasos , Femenino , Humanos , Persona de Mediana Edad , Transposición Congénitamente Corregida de las Grandes Arterias , Transposición de los Grandes Vasos/complicaciones , Transposición de los Grandes Vasos/cirugía , Vena Cava Superior , Taquicardia , Frecuencia Cardíaca
6.
Indian Heart J ; 76(1): 27-30, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38070672

RESUMEN

BACKGROUND: Single chamber atrial pacemaker should be sufficient for patients with sinus node dysfunction (SND) with normal atrioventricular (AV) conduction. However, most patients undergo dual chamber pacemaker implantation because of concern of new onset AV block. The annual incidence of new AV block has been reported from 0.6 to 4.4 % in various studies. OBJECTIVES: Our aim is to assess mode survival in sinus node dysfunction with normal AV conduction patients implanted with AAIR. METHODS: Patients who underwent single chamber atrial pacemaker implantation for SND with normal AV conduction between January 2014 and December 2021 were followed up for pacemaker device change, new onset AV block, bundle branch block, atrial fibrillation (AF), lead complications, reoperation and mortality rate. RESULTS: A total of 113 patients underwent single chamber atrial pacemaker implantation for SND during the study period. Mean age was 55.6 ± 12.7 years. During a mean follow up of 48.7 ± 24.9 months, none of the patients required pacemaker device change to VVIR/DDDR. Nine patients underwent reoperation, 5 for lead dislodgment, 1 for high threshold, 1 for pocket site erosion and 3 for pulse generator change. None developed AV block or AF with slow ventricular rate. Only 4 patients developed AF (3 paroxysmal,1 permanent). There were 3 deaths during follow up and none were sudden deaths. CONCLUSION: Single chamber atrial pacing is an acceptable mode of pacing in patients with SND in developing countries. Development of AV conduction abnormalities is rare in this relatively younger population.


Asunto(s)
Fibrilación Atrial , Bloqueo Atrioventricular , Marcapaso Artificial , Humanos , Adulto , Persona de Mediana Edad , Anciano , Síndrome del Seno Enfermo/complicaciones , Bloqueo Atrioventricular/terapia , Estimulación Cardíaca Artificial/efectos adversos , Marcapaso Artificial/efectos adversos , Atrios Cardíacos , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología
9.
J Arrhythm ; 38(5): 790-792, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36237865

RESUMEN

A young male presented with pre-excited atrial fibrillation. During an electrophysiology study, preexcitation suggestive of a pathway in posteroseptal location was confirmed but no tachycardia was inducible. Para-Hisian pacing was done during sinus rhythm. Is there retrograde conduction through the accessory pathway?

10.
Indian Heart J ; 74(4): 335-337, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35667401

RESUMEN

A total of 42 patients were studied for primary outcomes of quality of life and 6MWD between VVIR and DDD modes. At end of 2 months after device implantation, randomization was done and the device was programmed to VVIR or DDD modes. At the end of 2 months in this mode QOL and functional was assessed and the patient was switched to other mode. The same protocol was followed at the end of 2 months. We found no difference in functional capacity and quality of life between the two pacing modes. None of the patients developed pacemaker syndrome and there was no preference for any of the modes.


Asunto(s)
Bloqueo Atrioventricular , Marcapaso Artificial , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/terapia , Estimulación Cardíaca Artificial/métodos , Estudios Cruzados , Humanos , Calidad de Vida
13.
Spectrochim Acta A Mol Biomol Spectrosc ; 267(Pt 2): 120454, 2022 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-34666266

RESUMEN

New Schiff base ligand (DPMN) was synthesized from the condensation of 2-hydroxy-5-nitrobenzaldehyde and 2-amino-4,6-dimethoxypyrimidine which was confirmed by spectroscopic and analytical methods. Solid air stable copper nanoparticles (DPMN-CuNPs) were synthesized from its copper chloride salt and it is stabilized by the prepared Schiff base ligand by phase transfer assisted synthesis which is a modified Brust-Schiffrin technique. The formation of ligand stabilized copper nanoparticles was confirmed by UV-Visible and FT-IR spectroscopic techniques. The size, surface morphology and quality of DPMN-CuNPs were analyzed by SEM and TEM techniques. Antioxidant activities of DPMN and DPMN-CuNPs with DPPH, SOD, peroxide and nitrous oxide were analyzed by electronic absorption spectroscopy. DNA interaction between DPMN and DPMN-CuNPs with CT-DNA was carried out using electronic absorption, fluorescence, viscometric measurements and cyclic voltammetric techniques. Interaction between BSA and the synthesized compounds analyzed by electronic absorption spectroscopy, Antimicrobial studies confirmed that the synthesized DPMN-CuNPs possess significant biological activities than DPMN. Anticancer results suggest that prepared DPMN-CuNPs have significant anticancer activity against different cancer cell lines and least toxic effect against the normal (NHDF) cell line. Other than the positive response in biological evaluation, our DPMN-CuNPs possess good catalytic activity in methyl orange reduction, methylene blue degradation and nitro phenol reduction.


Asunto(s)
Antiinfecciosos , Antineoplásicos , Nanopartículas del Metal , Antiinfecciosos/farmacología , Antineoplásicos/farmacología , Antioxidantes/farmacología , Cobre , ADN , Ligandos , Pirimidinas , Espectroscopía Infrarroja por Transformada de Fourier
14.
Chemosphere ; 286(Pt 1): 131598, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34325269

RESUMEN

This report details the preparation, characterization, and applications of an inexpensive adsorbent obtained from Azadirachta indica leaves (Neem biochar (NBC)) and used to remove Cr(VI) from the synthetic waste water. The obtained NBC was characterized by XRD, FTIR, FESEM, EDX and Zeta potential measurements. Adsorption experiments conducted at various pH levels confirmed that 58.54 mg g-1 of Cr(VI) was removed by NBC at pH 2. Experiments conducted at various temperatures revealed that the Cr(VI) adsorption on NBC fits the Langmuir-type adsorption isotherm. A fixed-bed column study was conducted to obtain breakthrough curve for the adsorption process, which confirmed that the NBC usage rate was 4.63 g/L. Cr(VI)NBC was reactivated by NaOH treatment, and the reactivated NBC was used as a sorbent to remove fresh Cr(VI) from the synthetic waste water repeatedly. A cost analysis was also performed for the Cr(VI) removal confirmed that the process was less expensive.


Asunto(s)
Azadirachta , Contaminantes Químicos del Agua , Adsorción , Carbón Orgánico , Cromo/análisis , Concentración de Iones de Hidrógeno , Cinética , Hojas de la Planta/química , Contaminantes Químicos del Agua/análisis
15.
Indian Pacing Electrophysiol J ; 22(2): 115-117, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34826604

RESUMEN

A patient presented with documented narrow QRS tachycardia. During electrophysiological study, he has orthodromic reciprocating tachycardia with atrial activation consistent with left free wall accessory pathway. With induction of tachycardia, beats with LBBB morphology have shorter cycle length than those with narrow QRS. What is the mechanism?

17.
Artículo en Inglés | MEDLINE | ID: mdl-33712108
19.
Biomed Phys Eng Express ; 7(3)2021 03 17.
Artículo en Inglés | MEDLINE | ID: mdl-33662938

RESUMEN

Magnetocardiograms (MCG) provide clinically useful diagnostic information in a variety of cardiac dysfunctions. Low frequency baseline drifts and high frequency noise are inevitably present in routine MCG even for those measured inside magnetically shielded rooms. These interferences sometimes exceed subtle cardiac features in MCG recorded on subjects with implanted devices like cardiac pacemakers; this makes interpretation of cardiac magnetic fields difficult. The present study proposes a correlation-based beat-by-beat approach and principal component analysis to eliminate drifts and high frequency noise respectively; the approach is suitable for denoising both single and multi-channel MCG data. The methodology is critically evaluated on simulated noisy measurements using a 37 channel MCG system, when objects such as implantable permanent pacemaker and stainless-steel wire are sequentially kept externally on the chests of five healthy subjects. By characterizing the noise introduced by each of these objects, the deterioration in the quality of MCG and its subsequent restoration by using the proposed method is assessed. The performance of the proposed method is also compared with other conventional denoising techniques namely, bandpass filters, wavelets and ensemble empirical mode decomposition. The proposed method not only exhibits least distortion, but also preserves the beat-by-beat dynamics of cardiac time series. The method has also been illustrated on actual MCG measurements on two subjects with implanted pacemaker which highlight the ability of the proposed method for denoising MCG in general and during extremely noisy measurement situations.


Asunto(s)
Corazón , Campos Magnéticos , Humanos , Análisis de Componente Principal