Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
J Pharm Biomed Anal ; 148: 100-107, 2018 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-28982059

RESUMEN

A sensitive, specific and rapid LC-ESI-MS/MS method has been developed and validated for the quantification of tideglusib in mice plasma using warfarin as an internal standard (I.S.) as per regulatory guidelines. Sample preparation was accomplished through liquid-liquid extraction process. Chromatographic separation was performed on Atlantis dC18 column using mobile phase A (acetonitrile) and B (5mM ammonium acetate in water) in a flow-gradient mode. Elution of tideglusib and the I.S. occurred at ∼2.06 and 1.29min, respectively. The total chromatographic run time was 3.2min. A linear response function was established in the concentration range of 20.2-1008ng/mL. The intra- and inter-day accuracy and precision were in the range of 4.61-12.6 and 6.04-11.8%, respectively. This novel method has been applied to a pharmacokinetic study in mice.


Asunto(s)
Glucógeno Sintasa Quinasa 3 beta/antagonistas & inhibidores , Plasma/química , Tiadiazoles/sangre , Animales , Cromatografía Liquida/métodos , Límite de Detección , Extracción Líquido-Líquido/métodos , Masculino , Ratones , Ratones Endogámicos BALB C , Reproducibilidad de los Resultados , Espectrometría de Masas en Tándem/métodos
2.
Expert Opin Ther Targets ; 22(1): 59-73, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29171762

RESUMEN

INTRODUCTION: Polo like kinase (PLK) is known to play a pivotal role in various cell cycle processes to perpetuate proper division and growth of the cells. Polo like kinase-4 (PLK4) is one such kinase that appears in low abundance and plays a well-characterized role in centriole duplication. PLK4 deregulation (i.e. both overexpression and depletion of PLK4), leads to altered mitotic fidelity and thereby triggers tumorigenesis. Hence, over the last few years PLK4 has emerged as a potential therapeutic target for the treatment of various advanced cancers. Areas covered: In this review, we discuss the basic structure, expression, localization and functions of PLK4 along with its regulation by various proteins. We also discuss the role of altered PLK4 activity in the onset of cancer and the current pre-clinical and clinical inhibitors to regulate PLK4. Expert opinion: PLK4 mediated centriole duplication has a crucial role in maintaining mitotic correctness in normal cells, while its deregulation has a greater impact on genesis of cancer. Henceforth, a deep knowledge of the PLK4 levels, its role and interactions with various proteins in cancer is required to design effective inhibitors for clinical use.


Asunto(s)
Antineoplásicos/farmacología , Neoplasias/tratamiento farmacológico , Proteínas Serina-Treonina Quinasas/antagonistas & inhibidores , Animales , Centriolos/metabolismo , Diseño de Fármacos , Regulación Neoplásica de la Expresión Génica , Humanos , Mitosis/fisiología , Neoplasias/genética , Proteínas Serina-Treonina Quinasas/genética , Proteínas Serina-Treonina Quinasas/metabolismo
3.
J Pharm Biomed Anal ; 145: 454-461, 2017 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-28743076

RESUMEN

A sensitive and rapid LC-MS/MS method was developed and validated for the simultaneous quantitation of darolutamide and its active metabolite i.e. ORM-15341 in 50µL mice plasma using bicalutamide as an internal standard (I.S.) as per regulatory guidelines. Sample processing was accomplished through liquid-liquid extraction. Chromatographic separation was achieved using an Atlantis C18 column with an isocratic mobile phase comprising 0.2% formic acid:acetonitrile (35:65, v/v) at a flow rate of 0.8mL/min within 2.5min. Detection and quantitation were done by multiple reaction monitoring on a triple quadrupole mass spectrometer following the transitions: m/z 397→202, 395→202 and 429→255 for darolutamide, ORM-15341 and I.S, respectively in the negative ionization mode. The calibration curve was linear from 0.61-1097ng/mL for both darolutamide and ORM-15341. The intra- and inter-day precisions were in the range of 1.34-13.8 and 4.85-12.9 and 3.91-13.7 and 6.54-14.2%, for darolutamide and ORM-15341, respectively. Darolutamide and ORM-15341 were found to be stable under different stability conditions. The validated method was applied to a pharmacokinetic study in mice.


Asunto(s)
Pirazoles/sangre , Animales , Calibración , Cromatografía Liquida , Extracción Líquido-Líquido , Ratones , Reproducibilidad de los Resultados , Espectrometría de Masa por Ionización de Electrospray , Espectrometría de Masas en Tándem
4.
J Chromatogr Sci ; 55(7): 750-756, 2017 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-28383683

RESUMEN

A rapid and sensitive assay method has been developed and validated using liquid chromatography coupled to tandem mass spectrometry with electrospray ionization in the positive-ion mode for the estimation of SF0034 in mice plasma. The assay procedure involves a simple protein precipitation of SF0034 and tolbutamide (internal standard, IS) from mice plasma. Chromatographic separation was performed on an Atlantis dC18 column using an isocratic mobile phase comprising 0.2% formic acid:acetonitrile (10:90, v/v) at a flow rate of 0.60 mL/min. The total run time was 2.5 min. For mass spectrometric detection, the multiple reaction monitoring was used and ion transitions monitored were m/z 322 → 248 for SF0034 and 271 → 155 for IS. Method validation was performed as per regulatory guidelines and the results met the acceptance criteria. A calibration curve was constructed in the range of 2.08-2,078 ng/mL. The intra- and inter-day precision was in the range of 1.06-14.4% and 7.16-11.7%, respectively. This novel method has been applied to a pharmacokinetic study in mice.


Asunto(s)
Carbamatos/sangre , Cromatografía Liquida/métodos , Fenilendiaminas/sangre , Espectrometría de Masas en Tándem/métodos , Animales , Carbamatos/química , Carbamatos/farmacocinética , Modelos Lineales , Masculino , Ratones , Ratones Endogámicos BALB C , Fenilendiaminas/química , Fenilendiaminas/farmacocinética , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
5.
Expert Opin Ther Targets ; 21(4): 433-447, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28281906

RESUMEN

INTRODUCTION: Peptidyl arginine deiminase 4 (PAD4) is an enzyme that plays an important role in gene expression, turning out genetic code into functional products in the body. It is involved in a key post translational modification, which involves the conversion of arginine to citrulline. It regulates various processes such as apoptosis, innate immunity and pluripotency, while its dysregulation has a great impact on the genesis of various diseases. Over the last few years PAD4 has emerged as a potential therapeutic target for the treatment of rheumatoid arthritis (RA). Areas covered: In this review, we discuss the basic structure and function of PAD4, along with the role of altered PAD4 activity in the onset of RA and other maladies. We also elucidate the role of PAD4 variants in etiology of RA among several ethnic groups and the current pre-clinical inhibitors to regulate PAD4. Expert opinion: Citrullination has a crucial role in RA and several other disorders. Since PAD4 is an initiator of the citrullination, it is an important therapeutic target for inflammatory diseases. Therefore, an in depth knowledge of the roles and activity of PAD4 is required to explore more effective ways to conquer PAD4 related ailments, especially RA.


Asunto(s)
Antirreumáticos/farmacología , Artritis Reumatoide/tratamiento farmacológico , Hidrolasas/genética , Animales , Artritis Reumatoide/fisiopatología , Regulación de la Expresión Génica/genética , Humanos , Terapia Molecular Dirigida , Arginina Deiminasa Proteína-Tipo 4 , Desiminasas de la Arginina Proteica
6.
Expert Opin Ther Targets ; 21(3): 319-331, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28076698

RESUMEN

INTRODUCTION: Epigenetic changes lead to aberrant gene expression in cancer. SETDB1, a histone lysine methyltransferase plays an important role in methylation and gene silencing. Aberrant histone methylation at H3K9 by SETDB1 promotes silencing of tumor suppressor genes and thus contributes to carcinogenesis. Recent studies indicate that SETDB1 is abnormally expressed in various human cancer conditions which contributed to enhanced tumor growth and metastasis. Hence, SETDB1 appears to be a promising epigenetic target for therapeutic intervention. Areas covered: In this article, the structural features, localization and functions of SETDB1 are reviewed. Also, an overview of the role of SETDB1 in cancer and other disease mechanisms, the currently studied inhibitors for SETDB1 are mentioned. Expert opinion: Silencing of tumor suppressor genes due to excessive trimethylation at H3K9 by amplified SETDB1 levels is found in various cancerous conditions. Since epigenetic changes are reversible, SETDB1 holds promise as an important therapeutic target for cancer. Therefore, a better understanding of the role of SETDB1 and its interaction with various proteins in cancer-related mechanisms along with therapeutic interventions specific for SETDB1 may improve targeted cancer therapy.


Asunto(s)
Terapia Molecular Dirigida , Neoplasias/terapia , Proteína Metiltransferasas/genética , Animales , Epigénesis Genética , Regulación Neoplásica de la Expresión Génica , Silenciador del Gen , N-Metiltransferasa de Histona-Lisina , Humanos , Neoplasias/genética
7.
Biomed Chromatogr ; 31(7)2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27925271

RESUMEN

A sensitive and rapid LC-MS/MS method was developed and validated for the simultaneous quantitation of four HDAC inhibitors, namely belinostat (BST), panobinostat (PST), rocilinostat (RST) and vorinostat (VST), in mouse plasma as per regulatory guidelines. The analytes and internal standard were extracted from 50 µL mouse plasma by protein precipitation, followed by chromatographic separation using an Atlantis C18 column with an isocratic mobile phase comprising 0.1% formic acid-acetonitrile (25:75, v/v) at a flow rate of 0.5 mL/min within 2.5 min. Detection and quantitation were done by multiple reaction monitoring on a triple quadrupole mass spectrometer following the transitions: m/z 319 → 93, 350 → 158, 434 → 274 and 265 → 232 for BST, PST, RST and VST, respectively, in the positive ionization mode. The calibration curves were linear from 2.92 to 2921 ng/mL for BST and PST and from 1.01 to 1008 ng/mL for RST and VST with r2 ≥ 0.99 for all of the analytes. The intra- and inter-batch accuracy and precision (CV) across quality controls varied from 85.5 to 112% and from 2.30 to 12.5, respectively, for all of the analytes. Analytes were found to be stable under different stability conditions. The method was applied to an i.v. pharmacokinetic study in mice.


Asunto(s)
Cromatografía Liquida/métodos , Inhibidores de Histona Desacetilasas/sangre , Espectrometría de Masas en Tándem/métodos , Animales , Calibración , Inhibidores de Histona Desacetilasas/farmacocinética , Límite de Detección , Masculino , Ratones , Ratones Endogámicos BALB C , Estándares de Referencia , Reproducibilidad de los Resultados
8.
Biomed Chromatogr ; 31(2)2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27451018

RESUMEN

A sensitive, specific and rapid LC-ESI-MS/MS method has been developed and validated for the quantification of epacadostat in mouse plasma using tolbutamide as an internal standard (IS) as per regulatory guidelines. Sample preparation was accomplished through a protein precipitation. Chromatographic separation was performed on an Atlantis dC18 column using a binary gradient using mobile phase A (acetonitrile) and B (0.2% formic acid in water) at a flow rate of 0.90 mL/min. Elution of epacadostat and IS occurred at ~2.41 and 2.51 min, respectively. The total chromatographic run time was 3.2 min. A linear response function was established in the concentration range of 1.07-533 ng/mL. The intra- and inter-day accuracy and precision were in the ranges of 1.81-12.9 and 3.80-11.1%, respectively. This novel method has been applied to a pharmacokinetic study in mice.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Inhibidores Enzimáticos/sangre , Indolamina-Pirrol 2,3,-Dioxigenasa/antagonistas & inhibidores , Oximas/sangre , Sulfonamidas/sangre , Espectrometría de Masas en Tándem/métodos , Animales , Límite de Detección , Masculino , Ratones Endogámicos BALB C , Espectrometría de Masa por Ionización de Electrospray/métodos
9.
Expert Opin Ther Targets ; 21(2): 145-157, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28019723

RESUMEN

INTRODUCTION: SET and MYND domain containing-3 (SMYD3) is a member of the lysine methyltransferase family of proteins, and plays an important role in the methylation of various histone and non-histone targets. Proper functioning of SMYD3 is very important for the target molecules to determine their different roles in chromatin remodeling, signal transduction and cell cycle control. Due to the abnormal expression of SMYD3 in tumors, it is projected as a prognostic marker in various solid cancers. Areas covered: Here we elaborate on the general information, structure and the pathological role of SMYD3 protein. We summarize the role of SMYD3-mediated protein interactions in oncology pathways, mutational effects and regulation of SMYD3 in specific types of cancer. The efficacy and mechanisms of action of currently available SMYD3 small molecule inhibitors are also addressed. Expert opinion: The findings analyzed herein demonstrate that aberrant levels of SMYD3 protein exert tumorigenic effects by altering the epigenetic regulation of target genes. The partial involvement of SMYD3 in some distinct pathways provides a vital opportunity in targeting cancer effectively with fewer side effects. Further, identification and co-targeting of synergistic oncogenic pathways is suggested, which could provide much more beneficial effects for the treatment of solid cancers.


Asunto(s)
Antineoplásicos/farmacología , N-Metiltransferasa de Histona-Lisina/genética , Neoplasias/tratamiento farmacológico , Animales , Antineoplásicos/administración & dosificación , Antineoplásicos/efectos adversos , Diseño de Fármacos , Sinergismo Farmacológico , Epigénesis Genética , Regulación Neoplásica de la Expresión Génica , Humanos , Terapia Molecular Dirigida , Neoplasias/genética , Neoplasias/patología , Pronóstico
10.
J Pharm Biomed Anal ; 125: 140-4, 2016 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-27017572

RESUMEN

A sensitive, specific and rapid LC-ESI-MS/MS method has been developed and validated for the quantification of ulixertinib in mice plasma using phenacetin as an internal standard (I.S.) as per regulatory guidelines. Sample preparation was accomplished through a protein precipitation procedure with acetonitrile:methanol mixture. Chromatographic separation was performed on Atlantis dC18 column using a binary gradient using mobile phase A (0.2% formic acid in water) and B (acetonitrile) at a flow rate of 0.60mL/min. Elution of ulixertinib and I.S. occurred at ∼1.07 and 1.20min, respectively. The total chromatographic run time was 2.5min. A linear response function was established in the concentration range of 1.58-2054ng/mL. The intra- and inter-day accuracy and precisions were in the range of 2.11-11.8 and 5.80-11.4%, respectively. This novel method has been applied to a pharmacokinetic study in mice.


Asunto(s)
Aminopiridinas/sangre , Aminopiridinas/farmacocinética , Cromatografía Liquida/métodos , Pirroles/sangre , Pirroles/farmacocinética , Espectrometría de Masas en Tándem/métodos , Animales , Límite de Detección , Masculino , Ratones , Ratones Endogámicos BALB C , Reproducibilidad de los Resultados
11.
Biomed Chromatogr ; 30(7): 1138-1144, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26633099

RESUMEN

A highly sensitive, specific and rapid LC-ESI-MS/MS method has been developed and validated for the quantification of rocilinostat in small volume mouse plasma (20 µL) using vorinostat as an internal standard (IS) as per regulatory guidelines. Sample preparation was accomplished through a protein precipitation procedure with acetonitrile. Chromatography was achieved on Prodigy ODS-2 column using a binary gradient using mobile phase A (0.2% formic acid in water) and B (acetonitrile) at a flow rate of 0.38 mL/min. The total chromatographic run time was 4.1 min and the elution of rocilinostat and IS occurred at ~3.2 and 2.9 min, respectively. A linear response function was established in the concentration range of 0.28-1193 ng/mL in mouse plasma. The intra- and inter-day accuracy and precisions were in the ranges of 3.12-8.93 and 6.41-11.6%, respectively. This novel method has been applied to a pharmacokinetic study in mice. Copyright © 2016 John Wiley & Sons, Ltd.


Asunto(s)
Cromatografía Liquida/métodos , Ácidos Hidroxámicos/sangre , Pirimidinas/sangre , Espectrometría de Masas en Tándem/métodos , Animales , Límite de Detección , Masculino , Ratones , Ratones Endogámicos BALB C
12.
Eur J Med Chem ; 108: 274-286, 2016 Jan 27.
Artículo en Inglés | MEDLINE | ID: mdl-26689485

RESUMEN

Herein we report the synthesis and activity of a novel class of HDAC inhibitors based on 2, 3-diphenyl acrylic acid derivatives. The compounds in this series have shown to be potent HDAC inhibitors possessing significant antiproliferative activity. Further compounds in this series were subjected to metabolic stability in human liver microsomes (HLM), mouse liver microsomes (MLM), and exhibits promising stability in both. These efforts culminated with the identification of a developmental candidate (5a), which displayed desirable PK/PD relationships, significant efficacy in the xenograft models and attractive ADME profiles.


Asunto(s)
Antineoplásicos/administración & dosificación , Antineoplásicos/farmacología , Cinamatos/farmacología , Inhibidores de Histona Desacetilasas/administración & dosificación , Inhibidores de Histona Desacetilasas/farmacología , Estilbenos/administración & dosificación , Estilbenos/farmacología , Ensayos Antitumor por Modelo de Xenoinjerto , Administración Oral , Animales , Antineoplásicos/química , Línea Celular Tumoral , Proliferación Celular/efectos de los fármacos , Cinamatos/administración & dosificación , Cinamatos/química , Relación Dosis-Respuesta a Droga , Inhibidores de Histona Desacetilasas/química , Histona Desacetilasas/metabolismo , Humanos , Ratones , Microsomas Hepáticos/química , Microsomas Hepáticos/metabolismo , Estructura Molecular , Neoplasias Experimentales/tratamiento farmacológico , Neoplasias Experimentales/patología , Estilbenos/química , Relación Estructura-Actividad
13.
Biomed Chromatogr ; 29(11): 1664-9, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25914381

RESUMEN

A simple, specific, sensitive and reproducible high-performance liquid chromatography (HPLC) assay method has been developed and validated for the estimation of odanacatib in rat and human plasma. The bioanalytical procedure involves extraction of odanacatib and itraconazole (internal standard, IS) from a 200 µL plasma aliquot with simple liquid-liquid extraction process. Chromatographic separation was achieved on a Symmetry Shield RP18 using an isocratic mobile phase at a flow rate of 0.7 mL/min. The UV detection wave length was 268 nm. Odanacatib and IS eluted at 5.5 and 8.6 min, respectively with a total run time of 10 min. Method validation was performed as per US Food and Drug Administration guidelines and the results met the acceptance criteria. The calibration curve was linear over a concentration range of 50.9-2037 ng/mL (r(2) = 0.994). The intra- and inter-day precisions were in the range of 2.06-5.11 and 5.84-13.1%, respectively, in rat plasma and 2.38-7.90 and 6.39-10.2%, respectively, in human plasma. The validated HPLC method was successfully applied to a pharmacokinetic study in rats.


Asunto(s)
Compuestos de Bifenilo/farmacocinética , Cromatografía Líquida de Alta Presión/métodos , Cromatografía de Fase Inversa/métodos , Animales , Área Bajo la Curva , Compuestos de Bifenilo/sangre , Semivida , Humanos , Ratas , Reproducibilidad de los Resultados , Espectrofotometría Ultravioleta
14.
Artículo en Inglés | MEDLINE | ID: mdl-25797720

RESUMEN

A rapid selective and sensitive liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed for the quantitative determination of derivatised cytochrome P450-2C19 oxidation product (dansyl-4-OH mephenytoin) and its underivatised form (4-OH mephenytoin). Samples were anaysed on C18 column (Waters Xbridge, 50 mm×4.6 mm, 3.5 µm particle size) with the mobile phase consisting of 0.1% formic acid in water and 0.1% formic acid in acetonitrile. A gradient method with a short run time of 2.5 min and 3.5 min was developed for the analysis of dansyl-4-OH mephenytoin and 4-OH mephenytoin, respectively. The standard curve was linear (r(2)=0.9972 for 4-OH mephenytoin; r(2)=0.9946 for dansyl-4-OH mephenytoin) over the concentration range of 0.16 to 40 ng/mL for both derivatised and underivatised forms. The CV (%) and relative error (RE) for inter and intraassay at three QC levels for dansyl-4-OH mephenytoin was 0.97-5.85% and -9.80 to 2.51%, respectively. Whereas, for 4-OH mephenytoin the CV (%) and RE (%) at three QC levels was 0.82-3.47% and -6.69 to -0.01%, respectively. The developed method was validated for various parameters such as linearity, precision & accuracy, extraction recovery, matrix effect, autosampler stability and was proved to be consistent across three QC levels with overall CV (%) less than 15. Dansylation helped in increasing the sensitivity of hydroxy mephenytoin by 100-200 fold. Given the simplicity involved in derivatisation process, we believe that this novel methodology will change the current approaches used for the enhancing the detection sensitivity of 4-OH mephenytoin.


Asunto(s)
Citocromo P-450 CYP2C19/química , Compuestos de Dansilo/química , Pruebas de Enzimas/métodos , Inhibidores Enzimáticos/química , Mefenitoína/química , Cinética , Oxidación-Reducción
15.
J Pharm Anal ; 5(2): 120-129, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29403923

RESUMEN

A rapid, sensitive and selective pseudoMRM (pMRM)-based method for the determination of solutol HS15 (SHS15) in rat plasma was developed using liquid chromatography/tandem mass spectrometry (LC-MS/MS). The most abundant ions corresponding to SHS15 free polyethyleneglycol (PEG) oligomers at m/z 481, 525, 569, 613, 657, 701, 745, 789, 833, 877, 921 and 965 were selected for pMRM in electrospray mode of ionization. Purity of the lipophilic and hydrophilic components of SHS15 was estimated using evaporative light scattering detector (ELSD). Plasma concentrations of SHS15 were measured after oral administration at 2.50 g/kg dose and intravenous administration at 1.00 g/kg dose in male Sprague Dawley rats. SHS15 has poor oral bioavailability of 13.74% in rats. Differences in pharmacokinetics of oligomers were studied. A novel proposal was conveyed to the scientific community, where formulation excipient could be analyzed as a qualifier in the analysis of new chemical entities (NCEs) to address the spiky plasma concentration profiles.

16.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-671972

RESUMEN

A rapid, sensitive and selective pseudoMRM (pMRM)-based method for the determination of solutol HS15 (SHS15) in rat plasma was developed using liquid chromatography/tandem mass spectro-metry (LC–MS/MS). The most abundant ions corresponding to SHS15 free polyethyleneglycol (PEG) oligomers at m/z 481, 525, 569, 613, 657, 701, 745, 789, 833, 877, 921 and 965 were selected for pMRM in electrospray mode of ionization. Purity of the lipophilic and hydrophilic components of SHS15 was estimated using evaporative light scattering detector (ELSD). Plasma concentrations of SHS15 were measured after oral administration at 2.50 g/kg dose and intravenous administration at 1.00 g/kg dose in male Sprague Dawley rats. SHS15 has poor oral bioavailability of 13.74% in rats. Differences in pharmacokinetics of oligomers were studied. A novel proposal was conveyed to the scientific community, where formulation excipient could be analyzed as a qualifier in the analysis of new chemical entities (NCEs) to address the spiky plasma concentration profiles.

17.
Biomed Chromatogr ; 27(12): 1590-4, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23788266

RESUMEN

A novel, simple, specific, sensitive and reproducible high-performance liquid chromatography assay method has been developed and validated for the estimation of Orteronel in rat plasma. The bioanalytical procedure involves extraction of Orteronel and phenacetin (internal standard) from rat plasma with a simple liquid-liquid extraction process. The chromatographic analysis was performed on a Waters Alliance system using a gradient mobile phase conditions at a flow rate of 1 mL/min and a C18 column maintained at ambient room temperature. The eluate was monitored using a photodiode array detector set at 242. Orteronel and internal standard eluted at 4.8 and 6.2 min, respectively and the total run time was 9 min. Method validation was performed as per US Food and Drug Administration guidelines and the results met the acceptance criteria. The calibration curve was linear over a concentration range of 100-3149 ng/mL (r(2) = 0.995). The intra- and inter-day precisions were in the ranges of 0.31-7.87 and 3.97-6.35, respectively, in rat plasma. The validated HPLC method was successfully applied to a pharmacokinetic study of Orteronel in rats.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Imidazoles/sangre , Naftalenos/sangre , Animales , Cromatografía de Fase Inversa , Estabilidad de Medicamentos , Imidazoles/química , Imidazoles/farmacocinética , Modelos Lineales , Masculino , Naftalenos/química , Naftalenos/farmacocinética , Ratas , Ratas Sprague-Dawley , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Esteroide 17-alfa-Hidroxilasa/antagonistas & inhibidores
18.
Bioorg Med Chem Lett ; 23(9): 2532-7, 2013 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-23538115

RESUMEN

Herein, we report the development of highly potent HDAC inhibitors for the treatment of cancer. A series of adamantane and nor-adamantane based HDAC inhibitors were designed, synthesized and screened for the inhibitory activity of HDAC. A number of compounds exhibited GI50 of 10-100 nM in human HCT116, NCI-H460 and U251 cancer cells, in vitro. Compound 32 displays efficacy in human tumour animal xenograft model.


Asunto(s)
Adamantano/análogos & derivados , Adamantano/química , Adamantano/síntesis química , Antineoplásicos/química , Inhibidores de Histona Desacetilasas/química , Histona Desacetilasas/química , Adamantano/uso terapéutico , Animales , Antineoplásicos/farmacología , Antineoplásicos/uso terapéutico , Línea Celular Tumoral , Supervivencia Celular/efectos de los fármacos , Evaluación Preclínica de Medicamentos , Ensayos de Selección de Medicamentos Antitumorales , Células HCT116 , Inhibidores de Histona Desacetilasas/farmacología , Inhibidores de Histona Desacetilasas/uso terapéutico , Histona Desacetilasas/metabolismo , Humanos , Neoplasias Pulmonares/tratamiento farmacológico , Ratones , Ratones SCID , Relación Estructura-Actividad , Trasplante Heterólogo
19.
Biomed Chromatogr ; 27(4): 496-501, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23059909

RESUMEN

A highly sensitive and rapid bioanalytical method has been developed and validated for the estimation of indomethacin in rat plasma with liquid chromatography coupled to tandem mass spectrometry with electrospray ionization in the positive-ion mode. The assay procedure involves a simple liquid-liquid extraction of indomethacin and phenacetin (internal standard, IS) from rat plasma with acetonitrile. Chromatographic separation was achieved with 0.2% formic acid-acetonitrile (25:75, v/v) at a flow rate of 0.60 mL/min on an Atlantis dC18 column with a total run time 3.0 min. The MS/MS ion transitions monitored were 357.7 → 139.1 for indomethacin and 180.20 → 110.10 for IS. Method validation and pharmacokinetic study plasma analysis were performed as per FDA guidelines and the results met the acceptance criteria. The lower limit of quantitation achieved was 0.51 ng/mL and the linearity was observed from 0.51 to 25.5 ng/mL. The intra- and inter-day precisions were in the range of 1.00-10.2 and 5.88-9.80%, respectively. This novel method has been applied to an oral pharmacokinetic study in rats.


Asunto(s)
Antiinflamatorios no Esteroideos/sangre , Cromatografía Líquida de Alta Presión/métodos , Indometacina/sangre , Espectrometría de Masas en Tándem/métodos , Animales , Antiinflamatorios no Esteroideos/aislamiento & purificación , Cromatografía Líquida de Alta Presión/economía , Indometacina/aislamiento & purificación , Extracción Líquido-Líquido/economía , Extracción Líquido-Líquido/métodos , Masculino , Ratas , Ratas Sprague-Dawley , Sensibilidad y Especificidad , Espectrometría de Masa por Ionización de Electrospray/economía , Espectrometría de Masa por Ionización de Electrospray/métodos , Espectrometría de Masas en Tándem/economía , Factores de Tiempo
20.
Biomed Chromatogr ; 27(3): 356-64, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22865648

RESUMEN

A highly sensitive and specific LC-MS/MS-ESI method has been developed for simultaneous quantification of metformin (MFN) and repaglinide (RGN) in rat plasma (50 µL) using phenacetin as an internal standard (IS). Simple protein precipitation was used to extract MFN and RGN from rat plasma. The chromatographic resolution of MFN, RGN and IS was achieved with a mobile phase consisting of 0.2% formic acid in water-acetonitrile (1:1, v/v) with a time program flow gradient on a Chromolith RP-18e column. The total chromatographic run time was 3.5 min and the elution of MFN, RGN and IS occurred at 1.64, 2.21 and 2.15 min, respectively. A linear response function was established for the range of concentrations 0.855-394 and 0.021-21.7 ng/mL for MFN and RGN, respectively. The intra- and inter-day precision values for MFN and RGN met the acceptance as per FDA guidelines. MFN and RGN were stable in battery of stability studies viz., bench-top, auto-sampler and freeze-thaw cycles. The developed assay was applied to a pharmacokinetic study in rats.


Asunto(s)
Carbamatos/sangre , Cromatografía Liquida/métodos , Metformina/sangre , Piperidinas/sangre , Espectrometría de Masas en Tándem/métodos , Animales , Carbamatos/química , Carbamatos/farmacocinética , Estabilidad de Medicamentos , Modelos Lineales , Masculino , Metformina/química , Metformina/farmacocinética , Piperidinas/química , Piperidinas/farmacocinética , Ratas , Ratas Sprague-Dawley , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrometría de Masa por Ionización de Electrospray
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...