Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Arthroplasty ; 37(8S): S890-S894, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35093541

RESUMEN

BACKGROUND: Preoperative radiographic templating for total hip arthroplasty (THA) has been shown to be inaccurate, although essential for streamlining operating room efficiency. Although demographic data have shown to predict total knee arthroplasty component sizes, the unique contour and design among femoral stem implants have limited a similar application for hip arthroplasty. The purpose of this study was to determine whether demographic data may predict cementless THA size independent of the stem design. METHODS: A consecutive series of 1,653 index cementless metaphyseal-fitting THAs were reviewed between 2007 and 2019. This included 12 unique femoral component designs, 6 acetabular component designs, 60 femur size-design combinations, and 23 acetabular size-design combinations. Implanted component sizes and patient demographic data were collected, including gender, height, weight, laterality, age, race, and ethnicity. Multivariate linear regressions were formulated to predict implanted femur and acetabular component sizes from the demographic data. RESULTS: There was a significant linear correlation between gender, implant model, age, height, and weight for femur (R2 = 0.778; P < .001) and acetabular (R2 = 0.491; P < .001) sizes. Calculated femur and acetabular component sizes averaged within 0.97 and 0.95 sizes of those implants, respectively. Femur and acetabular sizes were predicted within 1 size 79.1% and 78.2% and within 2 sizes 94.3% and 94.6% of the time, respectively. CONCLUSIONS: Multivariate regression models were created based on specific demographics data to predict femur and acetabular component sizes. The model allows for simplified preoperative planning and potential cost savings implementation. A free phone application named EasyTJA was constructed for ease of implementation.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Prótesis de Cadera , Demografía , Fémur/diagnóstico por imagen , Fémur/cirugía , Humanos , Estudios Retrospectivos
2.
J Clin Orthop Trauma ; 18: 61-65, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33996450

RESUMEN

Several radiological methods of measuring anteversion of the acetabular component after total hip arthroplasty have been described, all time-consuming and with varying reproducibility. This study aimed to compare the recently proposed Area method to true cup anteversion as determined by an accelerometer. This study further applied this method programmatically to autonomously determine radiographic cup orientation using two computer programs, then compared these results to hand and accelerometer measurements. 160 anteroposterior pelvis radiographs were taken of a standard Sawbones® pelvis fitted with a total hip arthroplasty system. The acetabular cup was re-oriented between each radiograph, with anteversion ranging from 0° to 90°. An accelerometer was mounted to the cup to measure true cup anteversion. Radiographic anteversion was independently measured via three methods: by hand, linear image processing, and machine learning. Measurements were compared to triaxial accelerometer recordings. Coefficient of determination (R2) was found to be 0.997, 0.991, and 0.989 for hand measurements, the machine learning, and linear image processing, respectively. The machine learning program and hand measurements overestimated anteversion by 0.70° and 0.02° respectively. The program using linear techniques underestimated anteversion by 5.02°. Average runtime was 0.03 and 0.59 s for the machine learning and linear image processing program, respectively. The machine learning program averaged within 1° of cup orientation given a true cup anteversion less than 51°, and within 2° given an anteversion less than 85°. The Area method showed great accuracy and reliability with hand measurements compared to true anteversion. The results of this study support the use of machine learning for accurate, timely, autonomous assessment of cup orientation.

3.
Hip Int ; 31(6): 743-750, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32375525

RESUMEN

INTRODUCTION: Suboptimal acetabular component position can result in impingement, dislocation, and accelerated wear. Intraoperative pelvic motion has led to surgeon error and acetabular cup malposition. This study characterises the relationship between pelvic rotation and postoperative acetabular cup orientation. METHODS: A device was constructed to allow cadaveric pelvis rotation along three axes about an acetabular cup in fixed orientation. The acetabular cup was fixed in space at 40° of radiographic inclination and 15° of anteversion relative to the anterior pelvic plane to represent consistent surgeon intraoperative placement. Active marker clusters were fixed to surgical equipment while the cadaveric pelvis was cemented with passive reflective markers, both identified with the Optotrak Certus motion capture system. The reamed cadaveric pelvis was rotated along three axes from -45° to 45° of roll, -30° to 30° of tilt, and -35° to 35° of pitch. The change in component inclination and anteversion was recorded at each 5° interval. Using computed tomography 3D reconstruction, the experimental setup was duplicated computationally to assess against a greater range of pelvis and implant sizes. RESULTS: Radiographic anteversion and inclination showed a non-linear relationship dependent on pelvic roll, tilt, and pitch. Radiographic anteversion changed -0.59°, 0.76° and 0.01° while radiographic inclination changed 0.23°, 0.18° and 1.00° for every 1° of pelvic roll, tilt and pitch, respectively. Computationally, anteversion changed -0.61°, 0.75° and 0.00° while inclination changed 0.22°, 0.19° and 1.00° for every 1° of pelvic roll, tilt and pitch, respectively. These results were independent of cup and pelvis size. CONCLUSIONS: Intraoperative pelvic motion can significantly affect final cup position, and this should be accounted for when placing acetabular components during total hip arthroplasty. Based on this study, intraoperative adjustment of the acetabular component position based on pelvis motion may be implemented to improve postoperative component position.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Humanos , Pelvis , Tomografía Computarizada por Rayos X
4.
Bone Joint J ; 101-B(9): 1042-1049, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31474147

RESUMEN

AIMS: Several radiological methods of measuring anteversion of the acetabular component after total hip arthroplasty (THA) have been described. These are limited by low reproducibility, are less accurate than CT 3D reconstruction, and are cumbersome to use. These methods also partly rely on the identification of obscured radiological borders of the component. We propose two novel methods, the Area and Orthogonal methods, which have been designed to maximize use of readily identifiable points while maintaining the same trigonometric principles. PATIENTS AND METHODS: A retrospective study of plain radiographs was conducted on 160 hips of 141 patients who had undergone primary THA. We compared the reliability and accuracy of the Area and Orthogonal methods with two of the current leading methods: those of Widmer and Lewinnek, respectively. RESULTS: The 160 anteroposterior pelvis films revealed that the proposed Area method was statistically different from those described by Widmer and Lewinnek (p < 0.001 and p = 0.004, respectively). They gave the highest inter- and intraobserver reliability (0.992 and 0.998, respectively), and took less time (27.50 seconds (sd 3.19); p < 0.001) to complete. In addition, 21 available CT 3D reconstructions revealed the Area method achieved the highest Pearson's correlation coefficient (r = 0.956; p < 0.001) and least statistical difference (p = 0.704) from CT with a mean within 1° of CT-3D reconstruction between ranges of 1° to 30° of measured radiological anteversion. CONCLUSION: Our results support the proposed Area method to be the most reliable, accurate, and speedy. They did not support any statistical superiority of the proposed Orthogonal method to that of the Widmer or Lewinnek method. Cite this article: Bone Joint J 2019;101-B:1042-1049.


Asunto(s)
Acetábulo/diagnóstico por imagen , Artroplastia de Reemplazo de Cadera/efectos adversos , Anteversión Ósea/diagnóstico por imagen , Cabeza Femoral/diagnóstico por imagen , Prótesis de Cadera/efectos adversos , Acetábulo/cirugía , Anteversión Ósea/etiología , Diagnóstico por Computador , Cabeza Femoral/cirugía , Humanos , Radiografía , Reproducibilidad de los Resultados , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
5.
Physiol Rep ; 3(4)2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25921779

RESUMEN

The mdx mouse model of Duchenne muscular dystrophy (DMD) is used to study disease mechanisms and potential treatments, but its pathology is less severe than DMD patients. Other mouse models were developed to more closely mimic the human disease based on knowledge that upregulation of utrophin has a protective effect in mdx muscle. An mdx:utrophin(-/-) (dko) mouse was created, which had a severe disease phenotype and a shortened life span. An mdx:utrophin(+/-) mouse was also created, which had an intermediate disease phenotype compared to the mdx and dko mice. To determine the usefulness of mdx:utrophin(+/-) mice for long-term DMD studies, limb muscle pathology and function were assessed across the life span of wild-type, mdx, mdx:utrophin(+/-), and dko mice. Muscle function assessment, specifically grip duration and rotarod performance, demonstrated that mdx:utrophin(+/-) mice were weaker for a longer time than mdx mice. Mean myofiber area was smaller in mdx:utrophin(+/-) mice compared to mdx mice at 12 months. Mdx:utrophin(+/-) mice had a higher percentage of centrally nucleated myofibers compared to mdx mice at 6 and 12 months. Collagen I and IV density was significantly higher in mdx:utrophin(+/-) muscle compared to mdx at most ages examined. Generally, mdx:utrophin(+/-) mice showed an intermediate disease phenotype over a longer time course compared to the mdx and dko mice. While they do not genetically mirror human DMD, mdx:utrophin(+/-) mice may be a more useful animal model than mdx or dko mice for investigating long-term efficacy of potential treatments when fibrosis or muscle function is the focus.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...