Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Ophthalmol Ther ; 13(9): 2303-2329, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39090513

RESUMEN

OBJECTIVES: To determine whether the types and rates of post-surgical complications associated with the Port Delivery System with ranibizumab (PDS) are comparable with those reported for other ocular implants that cross the sclera. METHODS: Systematic literature reviews were conducted to determine the long-term (≥ 18-month) safety of ocular implants that cross the sclera in clinical trials and real-world studies. Complication types and rates were compared with those reported for the PDS in phase III clinical trials (Archway, Pagoda, and Pavilion). RESULTS: Sixteen clinical trials (24 publications) and 43 real-world studies were identified reporting 30 complications in eyes with 15 implant types and 8 ocular diseases. Implants were associated with an acceptable, well-characterized safety profile, with most complications resolving spontaneously or with treatment. Device-related complications were reported in 0.7% (0.0-5.0%) of study eyes in clinical trials and 1.3% (0.0-14.5%) of eyes in real-world studies. Rates of conjunctival complications were 2.1% (0.0-22.8%) and 2.2% (0.9-4.6%), respectively. The overall types and rates of adverse events of special interest reported for the PDS in phase III trials (cataract, conjunctival bleb, vitreous hemorrhage, conjunctival erosion, conjunctival retraction, endophthalmitis, implant dislocation, retinal detachment, and hyphema) were within the ranges reported for other ocular implants. CONCLUSIONS: The rates of complications reported in phase III clinical trials for the PDS were within the ranges reported for other ocular implants that cross the sclera. This suggests that the long-term safety of the PDS is consistent with other ocular devices established in ophthalmology clinical practice. TRIAL REGISTRATION: PROSPERO international prospective register of systematic reviews: CRD5202234129, CRD42022343129.

2.
J Control Release ; 366: 170-181, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38128885

RESUMEN

The Port Delivery System with ranibizumab (PDS) is an innovative intraocular drug delivery system that has the potential to reduce treatment burden in patients with retinovascular diseases. The Port Delivery Platform (PD-P) implant is a permanent, indwelling device that can be refilled in situ through a self-sealing septum and is designed to continuously deliver ranibizumab by passive diffusion through a porous titanium release control element. We present results for the studies carried out to characterize the stability of ranibizumab for use with the PD-P. Simulated administration, in vitro release studies, and modeling studies were performed to evaluate the compatibility of ranibizumab with the PD-P administration components, and degradation and photostability in the implant. Simulated administration studies demonstrated that ranibizumab was highly compatible with the PD-P administration components (initial fill and refill needles) and commercially available administration components (syringe, transfer needle, syringe closure). Subsequent simulated in vitro release studies examining continuous delivery for up to 12 months in phosphate buffered saline, a surrogate for human vitreous, showed that the primary degradation products of ranibizumab were acidic variants. The presence of these variants increased over time and potency remained high. The stability attributes of ranibizumab were consistent across multiple implant refill-exchanges. Despite some degradation within the implant, the absolute mass of variants released daily from the implant was low due to the continuous release mechanism of the implant. Simulated light exposure within the implant resulted in small increases in the relative amount of ranibizumab degradants compared with those seen over 6 months.


Asunto(s)
Sistemas de Liberación de Medicamentos , Ranibizumab , Humanos , Difusión , Agujas , Porosidad
3.
Drug Deliv ; 29(1): 1326-1334, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35499315

RESUMEN

The Port Delivery System with ranibizumab (PDS) is an innovative intraocular drug delivery system designed for the continuous delivery of ranibizumab into the vitreous for 6 months and beyond. The PDS includes an ocular implant, a customized formulation of ranibizumab, and four dedicated ancillary devices for initial fill, surgical implantation, refill-exchange, and explantation, if clinically indicated. Ranibizumab is an ideal candidate for the PDS on account of its unique physicochemical stability and high solubility. Controlled release is achieved via passive diffusion through the porous release control element, which is tuned to specific drug characteristics to accomplish a therapeutic level of ranibizumab in the vitreous. To characterize drug release from the implant, release rate was measured in vitro with starting concentrations of ranibizumab 10, 40, and 100 mg/mL, with release of ranibizumab 40 and 100 mg/mL found to remain quantifiable after 6 months. Using a starting concentration of 100 mg/mL, active release rate at approximately 6 months was consistent after the initial fill and first, second, and third refills, demonstrating reproducibility between implants and between multiple refill-exchanges of the same implant. A refill-exchange performed with a single 100-µL stroke using the refill needle was shown to replace over 95% of the implant contents with fresh drug. In vitro data support the use of the PDS with fixed refill-exchange intervals of at least 6 months in clinical trials.


Asunto(s)
Ranibizumab , Retina , Sistemas de Liberación de Medicamentos , Liberación de Fármacos , Reproducibilidad de los Resultados
4.
J Control Release ; 345: 101-107, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35248647

RESUMEN

The Port Delivery System with ranibizumab (PDS) consists of an implant that is a permanent, indwelling drug delivery device that can be refilled through a self-sealing septum and is designed to continuously release a customized formulation of ranibizumab into the vitreous by passive diffusion through a porous titanium release control element. Target release rates of ranibizumab via the implant used in studies of the PDS in patients with neovascular age-related macular degeneration were selected based on clinical and pharmacokinetic (PK) data from previously conducted intravitreal ranibizumab injection studies. In-vitro testing was performed to verify release rates with a range of ranibizumab concentrations before the phase II Ladder (NCT02510794) and phase III Archway (NCT03677934) trials of the PDS. Implants were filled with ranibizumab and were regularly transferred to new buffer-containing tubes to represent ocular ranibizumab clearance and release kinetics. Ranibizumab concentrations were measured and release rates calculated. Release rate data were fit to an exponential model and compared with expected release kinetics of diffusion. Release profiles of the implant releasing ranibizumab at concentrations of 10 mg/mL, 40 mg/mL, and 100 mg/mL were determined in the pre-phase II in-vitro studies. At day 3.5, mean (SD) ranibizumab release rates were 1.75 (0.07), 6.42 (0.35), and 16.69 (0.67) µg/d for PDS 10 mg/mL, 40 mg/mL, and 100 mg/mL, respectively. At month 6, mean (SD) release rates were 1.68 (0.05) and 4.16 (0.05) µg/d for PDS 40 mg/mL and 100 mg/mL, respectively. Measured release rates were within 90% of theoretical release rates during the course of drug release. PDS 100 mg/mL released 73% (SD, 1.92) of drug by month 6. In the pre-phase III in-vitro studies, mean (SD) release rates with PDS 100 mg/mL were 17.97 (0.90), 4.44 (0.11), and 2.45 (0.08) µg/d at 3.5 days, 6 months, and 9 months, respectively. Cumulative release (SD) was 73% (1.92) by month 6 and 87% (1.88) by month 9. The sustained, continuous, and reproducible release from the PDS observed in the in-vitro studies was also observed in Ladder and Archway. In conclusion, in-vitro studies were a powerful tool for characterizing and verifying ranibizumab release from the PDS implant and supported clinical evaluation of the PDS. PDS 100 mg/mL, which was associated with the longest therapeutic-level delivery of ranibizumab among the concentrations tested, was selected for evaluation in the pivotal phase III Archway trial.


Asunto(s)
Sistemas de Liberación de Medicamentos , Liberación de Fármacos , Ranibizumab , Inhibidores de la Angiogénesis , Ensayos Clínicos Fase II como Asunto , Ensayos Clínicos Fase III como Asunto , Humanos , Inyecciones Intravítreas , Resultado del Tratamiento
5.
Int J Pharm ; 305(1-2): 129-44, 2005 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-16207518

RESUMEN

TAXUStrade mark is a coronary drug-eluting stent system utilizing a formulation consisting of cellular-target drug paclitaxel and poly (styrene-isobutylene-styrene) (SIBS). The present study investigates the interaction and interfacial dynamics of paclitaxel incorporated in a nano-polymeric matrix system. Solution and solid-state CP/MAS NMR experiments were designed to characterize the microstructure of heterogeneous drug-polymer mixtures in terms of its composition, molecular mobility, molecular order, paclitaxel-SIBS molecular interactions, and molecular mobility of the drug in the polymer matrix. The NMR spectra demonstrated unchanged chemical shifts between the neat and incorporated paclitaxel, and suggested that the level of the interactions between paclitaxel and SIBS is limited to non-bonding interactions or physical interactions between paclitaxel and SIBS when mixed in solution under NMR detection. Carbon spin-lattice relaxation time and proton spin-lattice relaxation time in the rotating frame offer further confirmation that the mobility of paclitaxel is increased in the paclitaxel-SIBS mixture. The results also indicate that a change occurs from crystalline packing to amorphous packing in paclitaxel due to its intermolecular interaction with SIBS. Our studies were used in understanding the detailed structure, morphology, and molecular motion of paclitaxel in the paclitaxel-SIBS system and to probe chemical and physical heterogeneity down to the nanometer scale.


Asunto(s)
Antineoplásicos Fitogénicos/química , Paclitaxel/química , Polímeros/química , Estirenos/química , Química Farmacéutica , Espectroscopía de Resonancia Magnética/métodos
6.
Acta Biomater ; 1(1): 137-44, 2005 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-16701787

RESUMEN

The use of styrenic block copolymers has undergone a renaissance as a biomaterial and drug delivery matrix. The early promise posed by the physical and biological properties of these block copolymers for implantable medical devices was not met. However, there has been an increased understanding of the role of microphase separation on the mediation of the biological response. Poly (styrene-b-isobutylene-b-styrene) (SIBS) block copolymer has critical enabling properties related to processing, vascular compatibility and bio-stability that has resulted in its use as the matrix for paclitaxel delivery from Boston Scientific's TAXUS coronary stent. These enabling properties will allow the continuing development of medical devices based on SIBS that meet demanding physical and biological requirements.


Asunto(s)
Materiales Biocompatibles/química , Sistemas de Liberación de Medicamentos , Poliestirenos/química , Animales , Materiales Biocompatibles Revestidos , Vasos Coronarios/cirugía , Técnicas In Vitro , Ensayo de Materiales , Microscopía de Fuerza Atómica , Microscopía Electrónica , Paclitaxel/administración & dosificación , Stents , Porcinos
7.
J Biomed Mater Res A ; 71(4): 625-34, 2004 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-15514926

RESUMEN

The polymer carrier technology in the TAXUS drug-eluting stent consists of a thermoplastic elastomer poly(styrene-b-isobutylene-b-styrene) (SIBS) with microphase-separated morphology resulting in optimal properties for a drug-delivery stent coating. Comprehensive physical characterization of the stent coatings and cast film formulations showed that paclitaxel (PTx) exists primarily as discrete nanoparticles embedded in the SIBS matrix. Thermal and chemical analysis did not show any evidence of solubility of PTx in SIBS or of any molecular miscibility between PTx and SIBS. Atomic force microscope data images revealed for the first time three-dimensional stent coating surfaces at high spatial resolutions in air and in situ under phosphate-buffered saline as drug was released. PTx release involves the initial dissolution of drug particles from the PTx/SIBS coating surface. Morphological examination of the stent coatings in vitro supported an early burst release in most formulations because of surface PTx followed by a sustained slower release of PTx from the bulk coating. The in vitro PTx release kinetics were dependent on the formulation and correlated to the drug-to-polymer ratio. Atomic force microscopy analysis confirmed this correlation and further supported the concept of a matrix-based drug-release coating.


Asunto(s)
Antineoplásicos Fitogénicos/administración & dosificación , Paclitaxel/administración & dosificación , Stents , Tampones (Química) , Rastreo Diferencial de Calorimetría , Materiales Biocompatibles Revestidos , Preparaciones de Acción Retardada , Espectroscopía de Resonancia Magnética , Microscopía de Fuerza Atómica , Microscopía Electrónica de Rastreo , Microesferas , Fosfatos , Solubilidad , Estirenos/química , Difracción de Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA