1.
Med Phys ; 41(11): 111911, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25370644

RESUMEN

PURPOSE: To determine the impact of constrained reconstruction techniques on quantitative CT (qCT) of the lung parenchyma and airways for low x-ray radiation dose. METHODS: Measurement of small airways with qCT remains a challenge, especially for low x-ray dose protocols. Images of the COPDGene quality assurance phantom (CTP698, The Phantom Laboratory, Salem, NY) were obtained using a GE discovery CT750 HD scanner for helical scans at x-ray radiation dose-equivalents ranging from 1 to 4.12 mSv (12-100 mA s current-time product). Other parameters were 40 mm collimation, 0.984 pitch, 0.5 s rotation, and 0.625 mm thickness. The phantom was sandwiched between 7.5 cm thick water attenuating phantoms for a total length of 20 cm to better simulate the scatter conditions of patient scans. Image data sets were reconstructed using STANDARD (STD), DETAIL, BONE, and EDGE algorithms for filtered back projection (FBP), 100% adaptive statistical iterative reconstruction (ASIR), and Veo reconstructions. Reduced (half) display field of view (DFOV) was used to increase sampling across airway phantom structures. Inner diameter (ID), wall area percent (WA%), and wall thickness (WT) measurements of eight airway mimicking tubes in the phantom, including a 2.5 mm ID (42.6 WA%, 0.4 mm WT), 3 mm ID (49.0 WA%, 0.6 mm WT), and 6 mm ID (49.0 WA%, 1.2 mm WT) were performed with Airway Inspector (Surgical Planning Laboratory, Brigham and Women's Hospital, Boston, MA) using the phase congruency edge detection method. The average of individual measures at five central slices of the phantom was taken to reduce measurement error. RESULTS: WA% measures were greatly overestimated while IDs were underestimated for the smaller airways, especially for reconstructions at full DFOV (36 cm) using the STD kernel, due to poor sampling and spatial resolution (0.7 mm pixel size). Despite low radiation dose, the ID of the 6 mm ID airway was consistently measured accurately for all methods other than STD FBP. Veo reconstructions showed slight improvement over STD FBP reconstructions (4%-9% increase in accuracy). The most improved ID and WA% measures were for the smaller airways, especially for low dose scans reconstructed at half DFOV (18 cm) with the EDGE algorithm in combination with 100% ASIR to mitigate noise. Using the BONE + ASIR at half BONE technique, measures improved by a factor of 2 over STD FBP even at a quarter of the x-ray dose. CONCLUSIONS: The flexibility of ASIR in combination with higher frequency algorithms, such as BONE, provided the greatest accuracy for conventional and low x-ray dose relative to FBP. Veo provided more modest improvement in qCT measures, likely due to its compatibility only with the smoother STD kernel.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Pulmón/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Dosis de Radiación , Relación Señal-Ruido
2.
Med Phys ; 27(7): 1681-4, 2000 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-10947273

RESUMEN

Two patients developed skin ulcers secondary to high doses of diagnostic-energy x rays received during localization procedures as part of brachytherapy treatments. Both were morbidly obese and diabetic. The obesity led to the delivery of estimated skin doses of 83 Gy in one case and 29 Gy in the other in attempts to produce readable images on localization radiographs. This report discusses the factors leading to the injuries, the progression of the injuries over time, and the variables involved in the localization procedures with the aim of preventing future mishaps. The greatest contribution to the large skin dose was the need, with the equipment available, to use multiple exposures to produce a single film, because of the effect of the resultant reciprocity failure.


Asunto(s)
Braquiterapia/efectos adversos , Traumatismos por Radiación , Piel/efectos de la radiación , Úlcera/etiología , Neoplasias Endometriales/radioterapia , Femenino , Humanos , Obesidad , Piel/lesiones , Piel/patología , Úlcera/patología , Rayos X
4.
Med Phys ; 15(5): 768-72, 1988.
Artículo en Inglés | MEDLINE | ID: mdl-3185413

RESUMEN

The Ardran-Crooks kVp test cassette is widely used in diagnostic radiology to provide a rapid, simple, noninvasive measurement of x-ray tube potential. A modified version of this cassette called the Wisconsin kVp Test Cassette was introduced commercially in the U. S. in 1972. Since then, the method of calibration of these cassettes has changed significantly. Wisconsin kVp Test Cassettes calibrated by the manufacturer prior to August 1982 may yield underestimates of kVp measurements, particularly when using the 90-110 and 110-130 kVp regions with single-phase units. In August 1982 significant improvements in the calibration methods were implemented. The resultant change in calibration is demonstrated by data from the Centers for Radiological Physics. Present calibration methods are believed to be accurate within the greater of +/- 2 kVp or 2% of actual peak tube potential. Proper use of the cassette is necessary to achieve this level of accuracy.


Asunto(s)
Radiografía/normas , Radiometría/normas , Fenómenos Biofísicos , Biofisica , Humanos , Radiografía/instrumentación , Radiometría/instrumentación , Wisconsin
5.
Radiology ; 164(3): 867-8, 1987 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-3615889

RESUMEN

Knee arthrography, as performed at the authors' institution, was simulated and scattered radiation exposure to a radiologist's gonads, thyroid, and eye lens was measured with a sensitive ionization chamber. Results show that radiologists who regularly conduct knee arthrography examinations can incur doses to the gonads that are less than 6% of the U.S. limits, and to the thyroid and eye that are approximately 10% of the U.S. limits. Since the scatter radiation from overhead imaging of stress views constituted most (greater than or equal to 60%) of the dose to the lens of the eye and the thyroid, spot imaging was evaluated as a substitute for overhead imaging in the assessment of the anterior cruciate ligament. This substitution resulted in no loss of clinical information and has now completely replaced overhead imaging of stress views at this institution.


Asunto(s)
Artrografía , Articulación de la Rodilla/diagnóstico por imagen , Enfermedades Profesionales/prevención & control , Traumatismos por Radiación/prevención & control , Monitoreo de Radiación , Humanos , Dosis de Radiación , Riesgo , Dispersión de Radiación