Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Aust Endod J ; 48(1): 58-64, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34258843

RESUMEN

To compare the cutting efficiency of F6 Sky Taper (F6ST) and One Curve (OC) with different kinematics and cutting inclinations. Cutting efficiency of 80 new F6ST and OC was tested at 90° and 70° inclination in relation to the sample, in continuous rotation and reciprocation, against standardised gypsum samples for 120 seconds using a customised device. Data expressed as weight loss and length of the sample cut were analysed using two-way analysis of variance and Tukey t-test (P<.05). F6ST showed significantly higher cutting efficiency in reciprocation, while OC in continuous rotation. Regardless of inclination, F6ST showed statistically higher values than OC in reciprocation, while OC exhibited higher cutting ability in continuous rotation. The 70° inclination significantly improved the cutting efficiency of both files. Reciprocation improved the cutting efficiency of F6ST while continuous rotation enhanced cutting ability of OC. An inclined insertion improved the cutting ability, independently from the movement.


Asunto(s)
Níquel , Titanio , Fenómenos Biomecánicos , Aleaciones Dentales , Instrumentos Dentales , Diseño de Equipo , Incidencia , Preparación del Conducto Radicular
2.
Minerva Dent Oral Sci ; 71(3): 174-179, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34132510

RESUMEN

BACKGROUND: To assess the influence of multiple uses on the cyclic flexural fatigue and torsional resistance of Reciproc R25 (REC25) instruments. METHODS: Overall, 256 canals (two for each mandibular molar) were prepared using Reciproc R25 instruments. A total of 96 25-mm-long Reciproc R25 instruments were divided in six groups (N.=8) on the basis of different number of canals shaped: new instruments (control group), one, two, three, four, or six canals shaped during simulated clinical use for other groups respectively. Sixteen files were used for each of the six groups (eight instruments for cyclic fatigue test and eight ones for torsional test). Times to fracture (TtF) for cyclic fatigue and ultimate torsional strength and angle of rotation to fracture for torsional resistance were recorded. Data were statistically evaluated by the analysis of variance (ANOVA) with P<0.05. RESULTS: As for cyclic fatigue resistance, there was no significant difference between new REC25 and REC25 used in one, two and three canals respectively (P>0.05). REC25 used in four and six canals showed significant lower times to fracture when compared with other groups (P<0.05) with REC25 used in six canals showing the significant lowest times to fracture (P<0.05). Considering torsional resistance parameters, no significant difference was observed between the new and used instruments (P>0.05). CONCLUSIONS: REC25 files showed a significant decrease in cyclic fatigue resistance only when used in four or more molar canals while their torsional behavior was not affected by multiple uses.


Asunto(s)
Instrumentos Dentales , Diseño de Equipo , Preparación del Conducto Radicular , Rotación
3.
J Investig Clin Dent ; 10(4): e12434, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31294531

RESUMEN

AIM: The aim of the present study was to evaluate the immediate and residual antimicrobial activity of cordless sonic or ultrasonic devices on Enterococcus faecalis (E faecalis)-infected teeth. METHODS: A total of 140 single-rooted extracted teeth with E faecalis were grouped as follows (N = 15): conventional syringe irrigation with 3% sodium hypochlorite activated by ultrasonic device (group 1) or cordless ultrasonic device (group 2), EndoActivator (group 3) or without activation (group 4), conventional syringe irrigation with sterile bi-distilled water and ultrasonic device (group 5), EndoUltra (group 6), EndoActivator (group 7), or without activation (group 8). The remaining 20 teeth were used for positive and negative controls. Colony-forming units (CFU) and turbidity were recorded from bacteriological samples taken before and after irrigation and after 24 hours of re-incubation. Data were statistically analyzed using Student's t test, Mann-Whitney test, Kruskal-Wallis test, and Dunn's multiple comparison tests (P < .05). RESULTS: Groups 1 and 2 showed higher antimicrobial efficacy than groups 3 and 4 (P < .05). No bacteria reduction was found in groups 5-8 (P > .05). After 24 hours, regrowth of bacteria was not significantly different for all groups (P > .05). CONCLUSIONS: Ultrasound produced lower CFU and turbidity after treatment and after re-incubation of 24 hours than sonic or no activation.


Asunto(s)
Antiinfecciosos , Enterococcus faecalis , Cavidad Pulpar , Humanos , Irrigantes del Conducto Radicular , Preparación del Conducto Radicular , Hipoclorito de Sodio , Irrigación Terapéutica
4.
J Investig Clin Dent ; 10(3): e12409, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30848100

RESUMEN

AIM: The aim of the present study was to evaluate the resistance to cyclic fatigue of heat-treated single files used in proper or in reciprocating optimum torque reverse motions. METHODS: Ninety-six HyFlex electrical discharge machining (EDM), Reciproc R25 (Rec), WaveOne Primary (WO), and WaveOne Gold (WOG) Primary were used. Resistance to cyclic fatigue was determined by recording time to fracture in a stainless steel artificial canal. Differential scanning calorimetric analysis was performed. Data were analyzed by two-way analysis of variance and Bonferroni post-hoc tests at 0.05. RESULTS: In both movements, HyFlex EDM showed higher time to fracture than other files (P < 0.0001). Rec showed higher time to fracture than WO (P < 0.0001), while WOG showed higher cyclic fatigue resistance than Rec and WO with both movements (P < 0.005). CONCLUSIONS: Reciprocating optimum torque reverse motion improved significantly cyclic fatigue resistance of gold and controlled memory wire single files.


Asunto(s)
Instrumentos Dentales , Preparación del Conducto Radicular , Fenómenos Biomecánicos , Diseño de Equipo , Ensayo de Materiales , Estrés Mecánico , Titanio , Torque
5.
Restor Dent Endod ; 43(2): e25, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29765904

RESUMEN

OBJECTIVES: To evaluate the mechanical properties and metallurgical characteristics of the M3 Rotary and M3 Pro Gold files (United Dental). MATERIALS AND METHODS: One hundred and sixty new M3 Rotary and M3 Pro Gold files (sizes 20/0.04 and 25/0.04) were used. Torque and angle of rotation at failure (n = 20) were measured according to ISO 3630-1. Cyclic fatigue resistance was tested by measuring the number of cycles to failure in an artificial stainless steel canal (60° angle of curvature and a 5-mm radius). The metallurgical characteristics were investigated by differential scanning calorimetry. Data were analyzed using analysis of variance and the Student-Newman-Keuls test. RESULTS: Comparing the same size of the 2 different instruments, cyclic fatigue resistance was significantly higher in the M3 Pro Gold files than in the M3 Rotary files (p < 0.001). No significant difference was observed between the files in the maximum torque load, while a significantly higher angular rotation to fracture was observed for M3 Pro Gold (p < 0.05). In the DSC analysis, the M3 Pro Gold files showed one prominent peak on the heating curve and 2 prominent peaks on the cooling curve. In contrast, the M3 Rotary files showed 1 small peak on the heating curve and 1 small peak on the cooling curve. CONCLUSIONS: The M3 Pro Gold files showed greater flexibility and angular rotation than the M3 Rotary files, without decrement of their torque resistance. The superior flexibility of M3 Pro Gold files can be attributed to their martensite phase.

6.
Open Dent J ; 12: 219-229, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29682092

RESUMEN

PURPOSE: The objective of this investigation is to study prosthodontics and internal components resistance to the masticatory stress and considering different force directions by using Finite Element Method analysis (FEM). The structural materials of the components are usually Titanium alloy grade 4 or 5 and thus, guarantee the integration of the fixture in the bone due to the osteointegration phenomena. Even if the long-term dental implant survival rate is easy to be obtained and confirmed by numerous researches, the related clinical success, due to the alteration of the mechanical and prosthodontics components is still controversial. METHODS: By applying engineering systems of investigations like FEM and Von Mises analyses, it has been investigated how dental implant material was held against the masticatory strength during the dynamic masticatory cycles. A three-dimensional system involved fixture, abutment and the connection screws, which were created and analyzed. The elastic features of the materials used in the study were taken from recent literature data. RESULTS: Data revealed a different response for both types of devices, although implant neck and dental abutment showed better results for all conditions of loading while the abutment screw represented aweak point of the system. CONCLUSION: The data of this virtual model showed all the features of different prosthetic retention systems under the masticatory load. Clinicians should find better prosthetic balance in order to better distribute the stress over the component and to guarantee patients' clinical long-term results.

7.
J Med Chem ; 61(7): 2895-2909, 2018 04 12.
Artículo en Inglés | MEDLINE | ID: mdl-29494148

RESUMEN

The structure-activity relationship was investigated in a series of synthetic TLR4 antagonists formed by a glucosamine core linked to two phosphate esters and two linear carbon chains. Molecular modeling showed that the compounds with 10, 12, and 14 carbons chains are associated with higher stabilization of the MD-2/TLR4 antagonist conformation than in the case of the C16 variant. Binding experiments with human MD-2 showed that the C12 and C14 variants have higher affinity than C10, while the C16 variant did not interact with the protein. The molecules, with the exception of the C16 variant, inhibited the LPS-stimulated TLR4 signal in human and murine cells, and the antagonist potency mirrored the MD-2 affinity calculated from in vitro binding experiments. Fourier-transform infrared, nuclear magnetic resonance, and small angle X-ray scattering measurements suggested that the aggregation state in aqueous solution depends on fatty acid chain lengths and that this property can influence TLR4 activity in this series of compounds.


Asunto(s)
Monosacáridos/química , Monosacáridos/farmacología , Receptor Toll-Like 4/antagonistas & inhibidores , Animales , Unión Competitiva/efectos de los fármacos , Línea Celular , Ácidos Grasos/química , Células HEK293 , Humanos , Interleucina-8/biosíntesis , Ligandos , Lipopolisacáridos/metabolismo , Ratones , Modelos Moleculares , Conformación Molecular , Simulación del Acoplamiento Molecular , Simulación de Dinámica Molecular , Proteínas Recombinantes/química , Proteínas Recombinantes/farmacología , Transducción de Señal/efectos de los fármacos , Relación Estructura-Actividad
8.
Open Dent J ; 11: 546-556, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29238415

RESUMEN

BACKGROUND: Orbital fractures are classified as diseases usually related to common midface trauma. It represents the most challenging treatment due to the complex anatomy, physiology, and aesthetic role. A midface trauma involves also the zygomatic complex and the nose, however the orbit fracture seems to be a more frequent disease due to its anatomical features. OBJECTIVE: The purpose of this work is to retrospectively evaluate and record the frequency of the midfacial traumas and orbital fractures observed in the North Eastern Sicily. The results of the present data may be useful for the clinicians in order to recognize the kind of fracture just from the first general visit having a quick diagnosis and management. METHODS: In the years between 2001 and 2016, about 1200 patients with midfacial trauma and about 100 patients involving the orbital floor have been evaluated. All those patients underwent the surgical fracture reduction and a CT scan follow up control at one month, three months, six months and one year. RESULTS: Data showed high percentage of orbital floor, nose and mandibular body and ramus fractures; moreover the most frequent causes of fractures seem to be related to motor vehicle accident, followed by assaults, work and fall. CONCLUSION: The results have highlighted the changing trends in the causes of facial injuries, particularly the increasing incidence of assaults and the falling incidence of motor vehicle accidents in developed countries. The quick diagnosis and management proved fundamental for the successful treatment. Clinicians should be able to recognize the first symptoms in order to avoid possible complications.

9.
J Endod ; 43(3): 456-461, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28131416

RESUMEN

INTRODUCTION: The purpose of this study was to compare the formation of microcracks after canal preparation performed with different single-file systems as One Shape (Micro-Mega, Besancon, Cedex, France), F6 SkyTaper (Komet Italia Srl, Milan, Italy), HyFlex EDM (Coltene/Whaledent AG, Altstatten, Switzerland), WaveOne (Dentsply Maillefer, Ballaigues, Switzerland), Reciproc (VDW, Munich, Germany), and WaveOne Gold (Dentsply Maillefer). METHODS: Eighty-four human extracted mandibular central incisors (40-60 y) were selected and divided into 6 experimental groups (n = 12 teeth) and a control group (unprepared teeth): One Shape (group 1), F6 SkyTaper (group 2), HyFlex EDM (group 3), WaveOne (group 4), Reciproc (group 5), and WaveOne Gold (group 6). Roots were then sectioned at 3, 6, and 9 mm from the apex, and the surface was observed under a stereomicroscope. Data were analyzed using logistic regression (P < .05). RESULTS: No cracks were observed in the control group. All the systems tested caused cracks, mainly in the apical section (3 mm). HyFlex EDM (33.3%) and WaveOne Gold (58.3%) showed fewer microcracks than other experimental groups (P < .01); however, no significant difference was found between them in crack formation (P > .05). There was no difference among the other experimental groups (P > .05). CONCLUSIONS: All the instruments tested created dentinal cracks. Within the limitations of this study, the flexibility of nickel-titanium instruments because of heat treatment seems to have a significant influence on dentinal crack formation. HyFlex EDM and WaveOne Gold caused less microcracks than the other instruments tested.


Asunto(s)
Instrumentos Dentales/efectos adversos , Dentina/lesiones , Preparación del Conducto Radicular/efectos adversos , Adulto , Análisis del Estrés Dental , Dentina/patología , Diseño de Equipo , Humanos , Incisivo , Persona de Mediana Edad , Preparación del Conducto Radicular/instrumentación
10.
Eur Endod J ; 2(1): 1-6, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-33403337

RESUMEN

OBJECTIVE: Different single-file instruments and kinematics have been introduced on the market. It is important to know the cyclic fatigue performance of these instruments in these new kinematics such as reciprocation of Optimum Torque Reverse (OTR) motion. The aim of this study was to evaluate the resistance to cyclic fatigue of F6 SkyTaper and OneShape used in continuous rotation (proper rotation) or in reciprocating OTR motion. METHODS: A total of forty-eight nickel-titanium files were tested. Twenty-four instruments of both brands were divided into two groups (n=12) on the basis of the motion tested: continuous rotation (group 1) or reciprocating OTR motion (group 2). Resistance to cyclic fatigue was determined by recording time to fracture (TtF) in a stainless steel artificial canal with a 60° angle of curvature and 5 mm radius of curvature. Data were analysed by two-way analysis of variance and post-hoc Bonferroni tests for multiple comparisons with P<0.05 as the level of significance. RESULTS: F6 SkyTaper showed higher TtF compared with OneShape, both in continuous and in OTR motion (P<0.0001). The two tested instruments showed higher cyclic fatigue resistance in reciprocating OTR motion than continuous rotation (P<0.0001). CONCLUSION: OTR motion significantly improves cyclic fatigue resistance of the tested instruments. In addition, F6 SkyTaper showed higher cyclic fatigue resistance than OneShape in both motions.

11.
J Endod ; 41(10): 1730-4, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26189778

RESUMEN

Maxillary canine impactions are of multifactorial etiology. The incidence of maxillary canine impaction ranges from 1% to 4%. One of the reasons for canine impaction might be a deviated premolar root. This report describes surgical-orthodontic extrusion of an upper canine that occurred only after the endodontic surgery treatment of the adjacent deviated premolar root. Orthograde endodontic treatment followed by endodontic surgery with retrograde filling of the deviated premolar root was performed to obtain a surgical-orthodontic extrusion of the upper canine. A female patient, aged 15 years, with a class I molar relationship was referred to continue the orthodontic therapy. Although a correct surgical-orthodontic extrusion with adequate anchorage was carried out, the maxillary left canine had not erupted. Radiographic examination showed a deviated palatal root of the adjacent maxillary first premolar in the canine eruption path. Root canal filling followed by endodontic surgery of the first premolar deviated root has led to rapid progression of the canine and its placement in the arch in just 3 months. A multidisciplinary management involving endodontic treatment, endodontic surgery, and surgical-orthodontic extrusion could be considered a successful approach in the maxillary impacted canine cases in which adjacent premolar root is deviated. Long-term radiographic follow-up (6 years) indicated stable periodontal health of the canine and premolar without the presence of root resorption.


Asunto(s)
Diente Premolar/cirugía , Diente Canino/cirugía , Extrusión Ortodóncica , Raíz del Diente/cirugía , Diente Impactado/cirugía , Adolescente , Diente Premolar/diagnóstico por imagen , Diente Canino/diagnóstico por imagen , Femenino , Humanos , Maxilar , Raíz del Diente/diagnóstico por imagen , Diente Impactado/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS