Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Proc COMPSAC ; 2021: 774-784, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34568878

RESUMEN

Currently, wired respiratory rate sensors tether patients to a location and can potentially obscure their body from medical staff. In addition, current wired respiratory rate sensors are either inaccurate or invasive. Spurred by these deficiencies, we have developed the Bellyband, a less invasive smart garment sensor, which uses wireless, passive Radio Frequency Identification (RFID) to detect bio-signals. Though the Bellyband solves many physical problems, it creates a signal processing challenge, due to its noisy, quantized signal. Here, we present an algorithm by which to estimate respiratory rate from the Bellyband. The algorithm uses an adaptively parameterized Savitzky-Golay (SG) filter to smooth the signal. The adaptive parameterization enables the algorithm to be effective on a wide range of respiratory frequencies, even when the frequencies change sharply. Further, the algorithm is three times faster and three times more accurate than the current Bellyband respiratory rate detection algorithm and is able to run in real time. Using an off-the-shelf respiratory monitor and metronome-synchronized breathing, we gathered 25 sets of data and tested the algorithm against these trials. The algorithm's respiratory rate estimates diverged from ground truth by an average Root Mean Square Error (RMSE) of 4.1 breaths per minute (BPM) over all 25 trials. Further, preliminary results suggest that the algorithm could be made as or more accurate than widely used algorithms that detect the respiratory rate of non-ventilated patients using data from an Electrocardiogram (ECG) or Impedance Plethysmography (IP).

2.
IEEE J Biomed Health Inform ; 23(3): 1022-1031, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30040664

RESUMEN

OBJECTIVE: Utilizing passive radio frequency identification (RFID) tags embedded in knitted smart-garment devices, we wirelessly detect the respiratory state of a subject using an ensemble-based learning approach over an augmented Kalman-filtered time series of RF properties. METHODS: We propose a novel approach for noise modeling using a "reference tag," a second RFID tag worn on the body in a location not subject to perturbations due to respiratory motions that are detected via the primary RFID tag. The reference tag enables modeling of noise artifacts yielding significant improvement in detection accuracy. The noise is modeled using autoregressive moving average (ARMA) processes and filtered using state-augmented Kalman filters. The filtered measurements are passed through multiple classification algorithms (naive Bayes, logistic regression, decision trees) and a new similarity classifier that generates binary decisions based on current measurements and past decisions. RESULTS: Our findings demonstrate that state-augmented Kalman filters for noise modeling improves classification accuracy drastically by over 7.7% over the standard filter performance. Furthermore, the fusion framework used to combine local classifier decisions was able to predict the presence or absence of respiratory activity with over 86% accuracy. CONCLUSION: The work presented here strongly indicates the usefulness of processing passive RFID tag measurements for remote respiration activity monitoring. The proposed fusion framework is a robust and versatile scheme that once deployed can achieve high detection accuracy with minimal human intervention. SIGNIFICANCE: The proposed system can be useful in remote noninvasive breathing state monitoring and sleep apnea detection.


Asunto(s)
Aprendizaje Automático , Monitoreo Fisiológico/métodos , Frecuencia Respiratoria/fisiología , Procesamiento de Señales Asistido por Computador , Dispositivos Electrónicos Vestibles , Algoritmos , Humanos , Lactante , Monitoreo Fisiológico/instrumentación , Dispositivo de Identificación por Radiofrecuencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...