Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Family Med Prim Care ; 13(8): 3225-3230, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39228559

RESUMEN

Introduction: Because of wide heterogeneity in the epidemiology of heart failure among different populations, it is imperative to establish population-specific databases. Aims and Objectives: To describe the clinical profile, treatment patterns, and outcomes of heart failure patients admitted to our tertiary care hospital. Material and Methods: The study was a prospective observational study conducted over two years at our tertiary care hospital. It included patients admitted with acute and acute-on-chronic heart failure. Results: We recruited 264 patients. Mean age of the study population was 57.8 ± 15.14 years. Males were 157 (59.5%). Dilated cardiomyopathy was the most common cause followed by ischemic heart disease. Most common risk factors were hypertension, tobacco use, anemia, and diabetes. Heart failure with reduced ejection fraction was present in 154 (62%) patients. Acute de novo heart failure was present in 91 (34.5%) patients. The most common precipitant for heart failure exacerbation was infection, followed by ischemic causes and non-adherence to drugs. The mean duration of hospital stay was 7.5 ± 3.1 days. The in-hospital mortality was 8.7%, and cumulative six-month and one-year mortality was 23% and 28%, respectively. In multivariate analysis, renal failure, readmission, and not being on guideline-directed medical treatment were significant predictors of mortality. Conclusion: Our patients were younger, predominantly males, with dilated and ischemic cardiomyopathy as commonest etiology. Hypertension and tobacco smoking were most common risk factors, with infections as most common precipitants. Only one-third of patients were on guideline-directed medical therapy. The one-year mortality was 28% and was higher in those without guideline-directed medical therapy.

2.
Cureus ; 16(4): e58820, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38784341

RESUMEN

INTRODUCTION: The challenges posed by high altitude are particularly significant in terms of cardiovascular health. There are currently no data available on acute coronary syndrome (ACS) among Amarnath pilgrims. The objective of this study was to investigate the clinical and angiographic profiles of ACS among Amarnath pilgrims, focusing on demographic characteristics, risk factors, types of ACS, clinical presentation, angiographic findings, and in-hospital outcomes. By examining these aspects, we aimed to provide insights into the unique challenges faced by pilgrims during their spiritual journey and to identify potential strategies for improving the prevention and management of ACS in this population.  Methods: This was a hospital-based, prospective, observational study that included patients who had participated in the pilgrimage and presented with ACS between 2022 and 2023.  Results: Sixty patients were recruited for the study, with a mean age of 51.19 ± 11.17 years. Of these, 43 (71.7%) were male. Risk factors identified in the study included hypertension in 35 (58.3%), smoking in 23 (38.3%), diabetes mellitus in 18 (30%), and dyslipidemia in 25 (41.6%) patients. ST-elevation myocardial infarction (STEMI) was present in 46 (76.66%) patients, Anterior wall myocardial infarction (AWMI) occurred in 29 (48.3%), inferior wall myocardial infarction (IWMI) in 15 (25%), and high lateral wall myocardial infarction (HLWMI) in two (3.3%) patients. Of the 60 patients, 19 (31.6%) were in Killip class I, 16 (26.6%) were in class II, and 25 (41.6%) were in classes III or IV. The average time from the onset of symptoms to hospitalization was 7.6 ± 3.1 hours, significantly higher in those with Killip class III or IV (9.3 ± 3.6 vs. 5.4 ± 2.7 hours, p = 0.01). There were nine (15%) in-hospital deaths, and in the multivariate analysis, advanced Killip class (p = 0.04) and delays in hospitalization of more than six hours (p = 0.03) were found to be significant predictors of mortality. CONCLUSION: In conclusion, 40% of patients presented in the advanced Killip class, and 15% experienced in-hospital mortality. The average time from the onset of symptoms to hospitalization was significantly higher for those categorized in the advanced Killip classes. Our study highlights a significant association between advanced Killip class, delay in hospitalization, and in-hospital mortality among Amarnath pilgrims with ACS, underscoring the importance of timely intervention. It is recommended that appropriate measures be taken to improve patient outcomes in these cases.

3.
Egypt Heart J ; 76(1): 45, 2024 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-38607496

RESUMEN

BACKGROUND: Left ventricular ejection fraction falls when the myocardium has already lost a significant portion of its functional capacity. There are conflicting data on whether diastolic dysfunction precedes systolic dysfunction after cardiotoxic chemotherapy. We aimed to study systolic and diastolic dysfunction after cardiotoxic chemotherapy and whether diastolic dysfunction can predict subsequent risk of systolic dysfunction. It was an observational prospective cohort study, and patients receiving cardiotoxic chemotherapy were included. Baseline, demographic, and clinical details were recorded. Echocardiographic measurements of left ventricular systolic function, global longitudinal strain, and diastolic function were noted at baseline, three months, and 6 months. RESULTS: We included eighty patients. The mean age of the patients was 54.92 ± 7.6 years, predominantly females (80%). The mean left ventricular ejection fraction fell from 64.92 ± 1.96 to 60.97 ± 4.94 at 6 months. Low ejection fraction was seen in 8 (10%) patients at 6 months. The mean global longitudinal strain (GLS) at baseline was - 18.81 ± 0.797 and fell to - 17.65 ± 2.057 at 6 months, with 12 (15%) patients having low GLS (< - 18). Grade 1 diastolic dysfunction was seen in 22 (27.5%) patients, and grade 2 diastolic dysfunction was seen in 3 (3.8%) patients at 6 months. There was a significant decrease in E/A ratio (inflow early diastolic velocity/Inflow late diastolic velocity), mitral tissue Doppler velocity, and an increase in isovolumic relaxation time, mitral valve deceleration time, and E/e' (inflow early diastolic velocity/tissue Doppler mitral annular velocity), at three months and 6 months. Ejection fraction at 6 months was significantly and negatively correlated with diastolic dysfunction at three months (r = - 0.595, p = 0.02). CONCLUSIONS: Cardiotoxic chemotherapy is associated with early diastolic dysfunction. Early diastolic dysfunction predicts subsequent left ventricular systolic dysfunction.

4.
Indian Heart J ; 76(2): 101-107, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38408612

RESUMEN

INTRODUCTION: Identifying an Infarct-related artery (IRA)in Non-STEMI is sometimes tricky. Besides, myocardial infarction with non-obstructive coronary arteries (MINOCA) mimickers are often labeled as myocardial infarction. Late Gadolinium enhancement (LGE) on cardiac MRI can help in identifying IRA besides MINOCA mimickers. AIMS: To study the role of LGE on cardiac MRI(CMR) in NSTEMI. MATERIAL METHODS: It was a prospective observational, double-blinded study. 70 NSTEMI patients were prospectively enrolled over two years. CMR was done before coronary angiography (CAG) during the index hospitalization. Matching was done between IRA selected by CAG and IRA as determined by LGE on MRI. RESULTS: Mean age was 58 ± 15 years. CAG could not identify IRA in 38.6% (n = 27) patients. In this patient group, LGE-CMR identified IRA in 48.1% (n = 13) & a new non-CAD diagnosis was identified in 18.5% (n = 5) patients. IRA was identified in 61.4% (n = 43) by CAG & in this patient group, LGE-CMR identified a different IRA in 6.9% (n = 3) patients. LGE-CMR also identified a new non-CAD diagnosis in 11.6% (n = 5) of patients from this group. Overall, LGE-CMR led to a new IRA diagnosis in 23% (n = 16) patients & a diagnosis of non-ischemic pathogenesis in 14% (n = 10) patients. Non-Ischemic diagnosis on CMR included stress cardiomyopathy in 3, myocarditis in 6, and infiltrative disorder in 1 patient. CONCLUSION: CMR leads to new IRA diagnoses or non-ischemic pathogenesis in one-third of the cohort.


Asunto(s)
Angiografía Coronaria , Vasos Coronarios , Imagen por Resonancia Cinemagnética , Infarto del Miocardio sin Elevación del ST , Humanos , Masculino , Femenino , Persona de Mediana Edad , Estudios Prospectivos , Imagen por Resonancia Cinemagnética/métodos , Método Doble Ciego , Infarto del Miocardio sin Elevación del ST/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Medios de Contraste , Diagnóstico Diferencial , Electrocardiografía , Estudios de Seguimiento , Reproducibilidad de los Resultados
5.
J Saudi Heart Assoc ; 35(4): 301-310, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38116403

RESUMEN

Objectives: Very few studies have been done on Venous stenosis following the first transvenous cardiac device implantation. We aimed to assess the prevalence and predictors of Venous stenosis/Occlusion following the first transvenous cardiac device implantation with venous angiography at one year of follow-up. Methods: This study was a single-center prospective, observational study. Demographic, clinical, procedural, and device data was collected. All patients underwent a preimplant contrast and repeated venography at twelve months to look for upper limb venous anatomy, obstruction, or collaterals. Results: A total of 146 patients were included in the final analysis. 60 (41 %) patients developed some degree of venous stenosis. Most patients had mild to moderate stenosis, and almost all were asymptomatic. Among patient-related factors increasing age (64.66 ± 10.07 vs 60.91 ± 11.94 years p = 0.04), presence of hypertension (50.5 % vs 19.6 % p = 0.0004), diabetes (73 % vs 29.6 % p = 0.000) and dyslipidemia (66.7 % vs 36.3 p = 0.009) were significantly associated with Venous stenosis/occlusion. Among procedure-related factors, larger total lead diameter (3.88 ± 1.09 vs. 3.50 ± 1.03 mm p = 0.03) and implantation of biventricular devices (p = 0.0037) seem to be significantly associated with venous obstruction. In logistic regression analysis, hypertension (p = 0.018), total lead diameter (p = 0.024), and use of CRT-P/CRTD/ICD (p = 0.03) remained significant predictors of severe venous stenosis. Conclusions: Our study demonstrates venous obstruction in 40 % of cardiac implantable electronic device patients at one-year follow-up. Most patients have mild to moderate stenosis, and almost all are asymptomatic. Increasing age, hypertension, diabetes, dyslipidemia, larger total lead diameter, and implantation of biventricular devices are significantly associated with venous obstruction.

6.
Cureus ; 15(10): e47449, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38022041

RESUMEN

BACKGROUND AND AIM:  Interpretation of imaging modalities depends on robust normal reference limits. Ethnicity is an essential determinant of cardiac chamber sizes. Though few studies from India have focused on this research, it has yet to include the Kashmiri population. We aimed to study normal echocardiographic values of healthy Kashmiri adults and compare them with Western and Indian studies. METHODS:  It was a prospective observational study on healthy adults of Kashmir Valley. A comprehensive echocardiographic analysis following standardized protocols was performed. RESULTS:  A total of 2245 study participants were analyzed. The mean age was 32.52±11.55 years. There were 1100 (49%) males. Males had higher absolute left ventricular volumes and mass, left atrial volumes, right ventricular diameter, and aortic size, while females had higher absolute left ventricular ejection fraction and early and late diastolic mitral inflow velocities. Males had higher indexed left ventricular end-systolic volume, while females had higher indexed left ventricular end diastole diameter, aorta diameter, right ventricle, and left and right atrial sizes. Left ventricular mass and diastolic parameters were significantly associated with age. Compared with the American Society of Echocardiography/European Association of Cardiovascular Imaging, absolute values of left ventricle size, volumes, mass, right ventricle size, aortic size, and left and right atrial size were higher than those in our study. Our study population had a higher left ventricle ejection fraction. Among indexed parameters, left ventricle volumes, left ventricle systolic diameter, aortic annulus, and left and right atrial volumes were still significantly higher in Western data. While comparing with Indian data, we noted significant regional differences. CONCLUSION:  We provide normal reference values for our local population. We noted significant differences with Western as well as other Indian populations. Our study highlights the need for developing ethnic-specific reference values of various echocardiographic measurements.

8.
Egypt Heart J ; 75(1): 17, 2023 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-36897475

RESUMEN

BACKGROUND: Hemolysis after Patent ductus arteriosus (PDA) device closure is rare. Although in most cases, hemolysis settles on its own; however, in some cases it may not settle spontaneously and may require additional procedures like putting additional coils, gel foam or thrombin instillation, balloon occlusion, or removing it surgically. We report a case of adult PDA device closure who persisted with hemolysis and was managed by transcatheter retrieval. CASE PRESENTATION: A 52-year-old gentleman presented to us with a diagnosis of large PDA with operable hemodynamics. Descending thoracic aortic Angio showed a large 11 mm PDA. Transcatheter device closure was done in the same sitting with a 16 × 14 Amplatzer Ductal Occluder I(ADO) device,;however, after device release, the aortic end of the device was not fully formed and there was residual flow. The next morning patient started with gross hematuria with persistent residual flow. We tried to manage with conservative means including hydration, and blood transfusion; however, residual flow persisted for 10 days and his hemoglobin dropped from 13 gm/dl preprocedural to 7 gm/dl, creatinine increased from 0.5 mg/dl to 1.9 mg/dl, bilirubin increased to 3.5 mg/dl & urine showed hemoglobinuria. As the patient continued to deteriorate it was planned to retrieve the device by transcatheter approach. 10 French amplatzer sheath was parked in the pulmonary artery near the ductus. We tried with a combination of multiple catheters and Gooseneck snare (10 mm) and finally, we successfully retrieved with a combination of Multipurpose (MP) catheter and 10 mm Gooseneck snare. After that, we closed the defect successfully with a double disk device (muscular Ventricular septal defect 14 mm Amplatzer). The patient's hematuria settled and was discharged after 2 days with normal hemoglobin and creatinine. CONCLUSIONS: Patent ductus arteriosus ADO 1 device should not be released if the aortic end of the disk is not fully formed Patient should be carefully monitored for hemolysis if evidence of residual shunt and given supportive treatment. If conservative treatment fails, residual flow needs to be eliminated. Transcatheter retrieval although technically challenging is a feasible treatment. A muscular VSD device is a good alternative to the usual PDA device to close PDA, especially in adults.

9.
PLoS One ; 18(1): e0280469, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36662794

RESUMEN

In this article, a single-layer metasurface based reflector design is proposed for linear-to-linear cross-polarization conversion in microwave frequency range. The unit-cell of the proposed design consists of triple-arrow resonant design printed on a grounded FR4 substrate. Excellent cross-conversion is achieved over a broad frequency range (8.0-18.50 GHz) with polarization conversion efficiency higher than 90%. The proposed design has a large fractional bandwidth (FBW) of 80% due to three resonances occurring in the band. The polarization response is angularly stable with respect to oblique incidences with incidence angles up to 45°. The proposed design has been fabricated and experimentally validated. The measurement results are in good agreement with the simulation results.


Asunto(s)
Microondas , Refracción Ocular , Simulación por Computador , Vibración
10.
Sci Rep ; 12(1): 20073, 2022 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-36418481

RESUMEN

An impedance matched metasurface can efficiently channel the electromagnetic fields for maximum power transfer. The thin film based impedance matching techniques often utilize highly dissipative materials and destructive interference of reflection components from multiple subwavelength layers. Here, we propose a novel method to achieve anti reflection characteristics through destructive interference of antiparallel electromagnetic scattering emerging from chiral metasurface. The supercell structure of metasurface consists of four adjacent multi split-rings on FR-4 substrate. The split-rings are arranged to induce anti-parallel surface currents leading to destructive interference for scattered fields. The antireflection characteristics results in near perfect broadband absorption at dual frequency bands. A broadband absorption of 983 MHz is achieved between 12.687 and 13.669 GHz. Similarly, a narrow band absorption of 108 MHz is achieved in frequency range of 15.307-15.415 GHz. The impedance matched with unique symmetric design of supercell results in identical absorption for both x- and y-polarized incident fields. The numerical and experimental results verify broadband absorption characteristics at Ku band frequencies. The proposed metasurface absorber can be used for microwave energy harvesting applications.

11.
PLoS One ; 16(3): e0249269, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33780484

RESUMEN

Area efficient and high speed forward error correcting codes decoder are the demand of many high speed next generation communication standards. This paper explores a low complexity decoding algorithm of low density parity check codes, called the min-sum iterative construction a posteriori probability (MS-IC-APP), for this purpose. We performed the error performance analysis of MS-IC-APP for a (648,1296) regular QC-LDPC code and proposed an area and throughput optimized hardware implementation of MS-IC-APP. We proposed to use the layered scheduling of MS-IC-APP and performed other optimizations at architecture level to reduce the area and to increase the throughput of the decoder. Synthesis results show 6.95 times less area and 4 times high throughput as compared to the standard min-sum decoder. The area and throughput are also comparable to the improved variants of hard-decision bit-flipping (BF) decoders, whereas, the simulation results show a coding gain of 2.5 over the best implementation of BF decoder in terms of error performance.


Asunto(s)
Redes de Comunicación de Computadores , Procesamiento de Señales Asistido por Computador , Algoritmos
12.
PLoS One ; 16(1): e0245943, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33503067

RESUMEN

Stochastic computing has recently gained attention due to its low hardware complexity and better fault tolerance against soft errors. However, stochastic computing based circuits suffer from different errors which affect the output accuracy of these circuits. In this paper, an accurate and area-efficient stochastic computing based digital finite impulse response filter is designed. In the proposed work, constant uniform patterns are used as stochastic numbers for the select lines of different MUXes in the filter and the error performance of filter is analysed. Based on the error performance, the combinations of these patterns are proposed for reducing the output error of stochastic computing based filters. The architectures for generating these uniform patterns are also proposed. Results show that the proposed design methodology has better error performance and comparable hardware complexity as compared to the state-of-the-art implementations.


Asunto(s)
Metodologías Computacionales , Procesos Estocásticos , Algoritmos , Computadores , Diseño de Equipo
13.
Egypt Heart J ; 72(1): 48, 2020 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-32757079

RESUMEN

BACKGROUND: Although rare, the possibility of encountering an anomalous coronary artery is a reality. The outcome of such a procedure is greatly influenced by the awareness of the operator about the anatomical variations and the technique required. CASE PRESENTATION: A 50-year-old female patient presented with chest pain. On evaluation, she was found to have an inferior wall myocardial infarction. Left coronary angiography showed non-obstructive disease in the left anterior descending (LAD) and left circumflex artery (LCX). The right coronary artery could not be hooked despite multiple attempts and catheter changes. A non-specific aortic angiogram revealed anomalous origin of the right coronary artery (RCA) above the sinotubular junction on the left side. RCA was hooked with the AL-2 diagnostic catheter, and the percutaneous coronary intervention (PCI) procedure was completed via the same diagnostic catheter. CONCLUSION: In a life-threatening difficult situation like acute coronary syndrome with anomalous origin of coronary arteries, PCI can be done using a diagnostic catheter.

14.
Indian Heart J ; 72(4): 278-282, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32861383

RESUMEN

OBJECTIVE: Stenting of coarctation of aorta with covered or uncovered stents is the accepted modality of treatment in older children and adults. The indications which mandate the use of covered stents are still unclear. We attempted to study the early and late outcomes after stenting of native and recurrent coarctation of aorta with uncovered and covered stents. METHOD: This is a retrospective study of patients who underwent stenting for coarctation of aorta with covered or non-covered stents at our institute. Early and late outcome for both the groups were studied. RESULTS: Twenty patients underwent implantation of covered stent and twenty five patients had uncovered stent implantation. Patients in the covered stent group were older and had greater basal pressure gradient. More patients in the covered stent group had residual gradient >10 mm Hg after the procedure. There was no mortality or aortic wall injury in either group. Four patients in the covered stent group underwent planned re-intervention and two had unplanned re-intervention. None of the patients in the uncovered stent group had re-intervention. Higher incidence of late lumen loss was noted in the covered stent group. CONCLUSION: Uncovered stents can be safely implanted with minimal risk of aortic wall injury in patients with low risk anatomic features. Covered stent implantation is associated with higher incidence of planned and unplanned re-intervention.


Asunto(s)
Coartación Aórtica/cirugía , Materiales Biocompatibles Revestidos , Stents , Adolescente , Adulto , Coartación Aórtica/diagnóstico , Aortografía/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Diseño de Prótesis , Recurrencia , Estudios Retrospectivos , Factores de Tiempo , Adulto Joven
15.
Cardiol Young ; 27(3): 573-574, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27938458

RESUMEN

A newborn with tricuspid atresia and pulmonary atresia underwent ductal stenting. The aortic end of the ductus was not completely covered and was wide open; the baby was discharged on dual antiplatelets. The baby presented after a month with desaturation, and an angiogram showed extensive thrombus in the stent and the right pulmonary artery. The angle formed by the stent with the uncovered aortic end is likely to have precipitated the thrombus.


Asunto(s)
Anomalías Múltiples , Conducto Arterioso Permeable/cirugía , Oclusión de Injerto Vascular/etiología , Atresia Pulmonar/cirugía , Stents/efectos adversos , Trombosis/etiología , Angiografía , Oclusión de Injerto Vascular/diagnóstico , Humanos , Recién Nacido , Masculino , Atresia Pulmonar/diagnóstico , Trombosis/diagnóstico
16.
Indian Pacing Electrophysiol J ; 16(2): 53-58, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27676161

RESUMEN

BACKGROUND: Many subjects in community have non-type 1 Brugada pattern ECG with atypical symptoms, relevance of which is not clear. Provocative tests to unmask type 1 Brugada pattern in these patients would help in diagnosing Brugada Syndrome. However sensitivity and specificity of provocating drugs are variable. METHODS: We studied 29 patients referred to our institute with clinical presentation suggestive but not diagnostic of Brugada or with non-Type 1 Brugada pattern ECG. Flecainide Challenge Test (FCT) was done in these patients (IV Flecainide test in 4 patients and Oral Flecainide in 25 patients). Resting 12-lead ECG with standard precordial leads and ECG with precordial leads placed 1 Intercostal space above were performed after flecainide administration every 5 min for first 30 min and every 30 min thereafter until ECG became normal or upto 6 h. The positivity was defined as inducible Type 1 Brugada pattern in atleast 2 right sided leads. RESULT: Median age was 35(range = 5-65) years. In 16 (55%) patients the Type 1 Brugada pattern was unmasked. There were no episodes of major AV block, atrial or ventricular tachyarrhythmia. Three groups were considered for analysis: Group 1(n = 9) - FCT Positive among patients with non-type 1 Brugada ECG pattern, Group 2(n = 4) - FCT Negative among the patients with non-type 1 Brugada ECG pattern, and Group 3(n = 7) - FCT Positive among patients with no spontaneous Brugada ECG pattern. Binary logistic regression analysis found that family h/o SCD was predictive of FCT positivity in Group 1 (Odd's ratio 21, 95% Confidence interval 1.04 to 698.83, p = 0.004). CONCLUSION: Oral flecainide is useful and safe for unmasking of Type I Brugada pattern. In our study, among the many variables studied, family history of sudden cardiac death was the only predictor of flecainide test positivity among those with non-Type 1 Brugada pattern.

17.
J Clin Diagn Res ; 10(12): NC13-NC16, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28208900

RESUMEN

INTRODUCTION: Fuchs Heterochromic Iridocylitis (FHI) is a rare form of uveitis which is frequently complicated by cataract and glaucoma, but it does not show typical features of uveitis like pain, redness and posterior synechia. AIM: To study the clinical characteristics and outcome of cataract extraction with Intra Ocular Lens (IOL) implantation in patients with FHI. MATERIALS AND METHODS: The present prospective study was carried out in the Postgraduate Department of Ophthalmology, Sher-i-Kashmir Institute of Medical Sciences (SKIMS), Bemina from March 2012 to January 2015. The study included 33 eyes of 32 patients of FHI who underwent thorough clinical examination and cataract surgery with IOL implantation and were evaluated based on their visual outcome and intra and post-operative complications. Post-operative follow-up was done on 1st day, one week, one month, two month, six month and at twelve months. RESULTS: Mean age of our study group was 33.9 years (Range 18 to 65 years). No male or female preponderance was seen. There was bilateral involvement of eyes in only one case. Cataract and stellate keratic precipitates were present in all cases whereas, heterochromia was present in only six eyes (18.75%). Best Corrected Visual Acuity (BCVA) showed a significant improvement following cataract surgery (p<0.001). Post-operatively, 26 eyes (78.78%) showed an improvement of four lines or more (BCVA of > 6/12). Most common causes of decreased vision post-operatively were vitreous opacities in nine eyes (27.27%) followed by glaucoma in eight eyes (24.24%) and posterior capsular opacification in six eyes (18.18%). CONCLUSION: Cataract extraction with IOL lens implantation in FHI is a safe procedure associated with good visual prognosis and few complications. However, glaucoma is one of the main concerns and should be closely monitored both pre and post-operatively.

18.
J Conserv Dent ; 14(2): 196-8, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21814366

RESUMEN

The use of spiral computed tomography serves as a boon in endodontic diagnosis of complex anatomic variations. The present case demonstrates the spiral tomographic evaluation and endodontic management of a mandibular first molar with 5 canals (2 mesial and 3 distal canals), which is a very rare anatomic variant. Such anatomic variations should be taken into account in day to day endodontic practice to ensure a high degree of clinical success.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA