Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Thromb Haemost ; 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39214313

RESUMEN

BACKGROUND: Patients with primary immune thrombocytopenia (ITP) have an increased risk of thrombosis, which may be due to altered fibrinolysis. OBJECTIVES: To elucidate the clinical impact of delayed fibrinolysis in ITP patients. METHODS: A turbidimetric clot formation and lysis assay and a fluorometric plasmin generation (PG) assay were performed, and levels of plasminogen activator inhibitor-1 (PAI-1), tissue plasminogen activator (tPA), tPA-PAI-1 complexes, α2-antiplasmin, thrombin activatable fibrinolysis inhibitor, and D-dimer were assessed in 86 adult primary ITP patients and 78 healthy controls (HCs). RESULTS: ITP patients showed significantly delayed clot formation, increased clot density, and prolonged clot lysis time (CLT) compared with HCs, with a median (IQR) CLT of 28.0 (13.7-34.7) minutes in patients and 17.3 (12.0-28.0) minutes in HCs, while in the PG assay, only the lag time was prolonged. In ITP patients compared with controls, PAI-1 was higher (1.2 [0.8-2.6] vs 1.1 [0.6-2.1] U/mL) and tPA antigen and activity were lower (tPA antigen: 2.6 [1.1-4.4] vs 3.7 [3.2-4.7] ng/mL; tPA activity ≤ 0 U/mL: 26% vs 7%). TPA-PAI-1 complex levels were positively associated with CLT in multiple linear regression analysis (ß = 0.241; P = .019), whereas PG parameters were not associated with CLT. Six patients who developed thrombosis during follow-up had higher levels of tPA-PAI-1 complexes. CONCLUSION: Prolonged CLT and delayed onset of PG may indicate a hypofibrinolytic tendency in ITP patients, as also indicated by high PAI-1 and low tPA levels. No association was found between fibrinolytic potential and the bleeding phenotype, whereas higher tPA-PAI-1 complex levels were associated with prolonged CLT and increased in patients with future thrombosis.

2.
Laryngoscope Investig Otolaryngol ; 8(3): 712-719, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37342118

RESUMEN

Objective: To evaluate the concept and efficacy of an adjustable implant (Prototype SH30: porcine implant and APrevent® VOIS: human concept) for treatment of unilateral vocal fold paralysis (UVFP) via in vivo mini-pig studies, human computed tomographic (CT) and magnetic resonance (MR) image analysis, ex-vivo aerodynamic and acoustic analysis. Methods: Feasibility testing and prototype implantation were performed using in-vivo UVFP porcine model (n = 8), followed by a dimensional finding study using CT and MR scans of larynges (n = 75) for modification of the implant prototypes. Acoustic and aerodynamic measurements were recorded on excised canine (n = 7) larynges with simulated UVFP before and after medialization with VOIS-Implant. Results: The prototype showed in the in-vivo UVFP porcine model an improved glottic closure from grade 6 incomplete closure to complete closure (n = 5), to grade 2 incomplete closure (n = 2) and grade 3 incomplete closure (n = 1). On human CT/MR scans the identification of the correct size was successful in 97.3% using the thyroid cartilage alar "distance S" as the only parameter, which is an important step towards procedure standardization and implant design. Results were confirmed with implantation in human laryngeal cadavers (n = 44). Measurements of the acoustic and aerodynamic effects after implantation showed a significant decreased phonation threshold pressure (p = .0187), phonation threshold flow (p = .0001) and phonation threshold power (p = .0046) on excised canine larynges with simulated UVFP. Percent jitter and percent shimmer decreased (p = .2976; p = .1771) but not significant. Conclusions: Based on the preclinical results four sizes, differing in medial length, implant width and expansion direction of silicone cushions, seem to be enough to satisfy laryngeal size variations. This concept is significantly effective in medializing UVFP and improving the aerodynamic and acoustic qualities of phonation as reported in a preliminary clinical outcome study with long-term implantation. Level of Evidence: N/A.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA