Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Heart Surg Forum ; 19(4): E208-15, 2016 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-27585205

RESUMEN

Biomodeling the human anatomy in exact structure and size is an exciting field of medical science. Utilizing medical data from various medical imaging topography, the data of an anatomical structure can be extracted and converted into a three-dimensional virtual biomodel; thereafter a physical biomodel can be generated utilizing rapid prototyping machines. Here, we have reviewed the utilization of this technology and have provided some guidelines to develop biomodels of cardiac structures. Cardiac biomodels provide insights for cardiothoracic surgeons, cardiologists, and patients alike. Additionally, the technology may have future usability for tissue engineering, robotic surgery, or routine hospital usage as a diagnostic and therapeutic tool for cardiovascular diseases (CVD). Given the broad areas of application of cardiac biomodels, attention should be given to further research and development of their potential.


Asunto(s)
Cardiología/métodos , Simulación por Computador , Corazón/anatomía & histología , Imagenología Tridimensional/métodos , Modelos Biológicos , Tomografía Computarizada por Rayos X , Humanos
2.
J Neurol Surg A Cent Eur Neurosurg ; 75(1): 12-5, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23315670

RESUMEN

INTRODUCTION: Navigation in neurosurgery has expanded rapidly; however, suitable models to train end users to use the myriad software and hardware that come with these systems are lacking. Utilizing three-dimensional (3D) industrial rapid prototyping processes, we have been able to create models using actual computed tomography (CT) data from patients with pathology and use these models to simulate a variety of commonly performed neurosurgical procedures with navigation systems. AIM: To assess the possibility of utilizing models created from CT scan dataset obtained from patients with cranial pathology to simulate common neurosurgical procedures using navigation systems. METHODOLOGY: Three patients with pathology were selected (hydrocephalus, right frontal cortical lesion, and midline clival meningioma). CT scan data following an image-guidance surgery protocol in DIACOM format and a Rapid Prototyping Machine were taken to create the necessary printed model with the corresponding pathology embedded. The ability in registration, planning, and navigation of two navigation systems using a variety of software and hardware provided by these platforms was assessed. RESULTS: We were able to register all models accurately using both navigation systems and perform the necessary simulations as planned. CONCLUSION: Models with pathology utilizing 3D rapid prototyping techniques accurately reflect data of actual patients and can be used in the simulation of neurosurgical operations using navigation systems.


Asunto(s)
Encéfalo/cirugía , Modelos Anatómicos , Neuronavegación/métodos , Cráneo/cirugía , Cirugía Asistida por Computador/métodos , Encéfalo/diagnóstico por imagen , Humanos , Radiografía , Cráneo/diagnóstico por imagen
3.
Int J Med Sci ; 10(6): 719-29, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23630436

RESUMEN

Despite the importance of DENV as a human pathogen, there is no specific treatment or protective vaccine. Successful entry into the host cells is necessary for establishing the infection. Recently, the virus entry step has become an attractive therapeutic strategy because it represents a barrier to suppress the onset of the infection. Four putative antiviral peptides were designed to target domain III of DENV-2 E protein using BioMoDroid algorithm. Two peptides showed significant inhibition of DENV when simultaneously incubated as shown by plaque formation assay, RT-qPCR, and Western blot analysis. Both DET4 and DET2 showed significant inhibition of virus entry (84.6% and 40.6% respectively) using micromolar concentrations. Furthermore, the TEM images showed that the inhibitory peptides caused structural abnormalities and alteration of the arrangement of the viral E protein, which interferes with virus binding and entry. Inhibition of DENV entry during the initial stages of infection can potentially reduce the viremia in infected humans resulting in prevention of the progression of dengue fever to the severe life-threatening infection, reduce the infected vector numbers, and thus break the transmission cycle. Moreover these peptides though designed against the conserved region in DENV-2 would have the potential to be active against all the serotypes of dengue and might be considered as Hits to begin designing and developing of more potent analogous peptides that could constitute as promising therapeutic agents for attenuating dengue infection.


Asunto(s)
Antivirales/administración & dosificación , Virus del Dengue/efectos de los fármacos , Dengue/genética , Péptidos/administración & dosificación , Antivirales/síntesis química , Dengue/tratamiento farmacológico , Dengue/virología , Virus del Dengue/patogenicidad , Humanos , Péptidos/síntesis química , Péptidos/genética , Proteínas del Envoltorio Viral/síntesis química , Proteínas del Envoltorio Viral/genética , Internalización del Virus/efectos de los fármacos
4.
Am J Rhinol Allergy ; 26(5): e132-6, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23168144

RESUMEN

BACKGROUND: Surgical navigation systems have been used increasingly in guiding complex ear, nose, and throat surgery. Although these are helpful, they are only beneficial intraoperatively; thus, the novice surgeon will not have the preoperative training or exposure that can be vital in complex procedures. In addition, there is a lack of reliable models to give surgeons hands-on training in performing such procedures. METHODS: A technique using an industrial rapid prototyping process by three-dimensional (3D) printing was developed, from which accurate spatial models of the nasal cavity, paranasal sinuses (sphenoid sinus in particular), and intrasellar/pituitary pathology were produced, according to the parameters of an individual patient. Image-guided surgical (IGS) techniques on two different platforms were used during endoscopic transsphenoidal surgery to test and validate the anatomical accuracy of the sinus models by comparing the models with radiological images of the patient on IGS. RESULTS: It was possible to register, validate, and navigate accurately on these models using commonly available navigation stations, matching accurately the anatomy of the model to the IGS images. CONCLUSION: These 3D models can be reliably used for teaching/training and preoperative planning purposes.


Asunto(s)
Modelos Anatómicos , Cavidad Nasal/anatomía & histología , Cavidad Nasal/cirugía , Procedimientos Quírurgicos Nasales , Hueso Esfenoides/anatomía & histología , Hueso Esfenoides/cirugía , Endoscopía , Estudios de Factibilidad , Humanos , Imagenología Tridimensional , Cavidad Nasal/diagnóstico por imagen , Senos Paranasales/anatomía & histología , Senos Paranasales/diagnóstico por imagen , Senos Paranasales/cirugía , Hipófisis/anatomía & histología , Hipófisis/diagnóstico por imagen , Hipófisis/cirugía , Medicina de Precisión , Cirugía Asistida por Computador , Tomografía Computarizada por Rayos X
5.
J Clin Neurosci ; 19(4): 574-7, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22305869

RESUMEN

In neurosurgery and ear, nose and throat surgery the application of computerised navigation systems for guiding operations has been expanding rapidly. However, suitable models to train surgeons in using navigation systems are not yet available. We have developed a technique using an industrial, rapid prototyping process from which accurate spatial models of the cranium, its contents and pathology can be reproduced for teaching. We were able to register, validate and navigate using these models with common available navigation systems such as the Medtronic StealthStation S7®.


Asunto(s)
Modelos Anatómicos , Neuronavegación/educación , Cráneo/anatomía & histología , Cráneo/cirugía , Humanos
6.
Am J Rhinol Allergy ; 26(5): 132-136, 2012 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-29025465

RESUMEN

BACKGROUND: Surgical navigation systems have been used increasingly in guiding complex ear, nose, and throat surgery. Although these are helpful, they are only beneficial intraoperatively; thus, the novice surgeon will not have the preoperative training or exposure that can be vital in complex procedures. In addition, there is a lack of reliable models to give surgeons hands-on training in performing such procedures. METHODS: A technique using an industrial rapid prototyping process by three-dimensional (3D) printing was developed, from which accurate spatial models of the nasal cavity, paranasal sinuses (sphenoid sinus in particular), and intrasellar/pituitary pathology were produced, according to the parameters of an individual patient. Image-guided surgical (IGS) techniques on two different platforms were used during endoscopic transsphenoidal surgery to test and validate the anatomical accuracy of the sinus models by comparing the models with radiological images of the patient on IGS. RESULTS: It was possible to register, validate, and navigate accurately on these models using commonly available navigation stations, matching accurately the anatomy of the model to the IGS images. CONCLUSION: These 3D models can be reliably used for teaching/training and preoperative planning purposes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA