Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Orthopedics ; 44(2): 111-116, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33416895

RESUMEN

Osteoarthritis of the hip and knee is known to affect sexual activity. For patients with osteoarthritis, pain during sexual activity can lead to decreased quality of life and other associated health issues. The authors designed a prospective study to evaluate the effect of total hip arthroplasty and total knee arthroplasty on the psychosocial and physical aspects of sexuality pre- and postoperatively. Between April 2009 and December 2011, patients received questionnaires in the mail preoperatively. They were asked to return the preoperative questionnaire before surgery and the postoperative questionnaire 6 months after surgery. Data were analyzed to evaluate the psychosocial and physical aspects of sexuality and participants' subjective assessment of their appearance. Preoperatively, 91% and 67% of patients reported psychosocial and physical issues, respectively. After the arthroplasty procedure, 84% (P<.001) and 47% (P<.001) of patients reported improvement psychosocially and physically, respectively. Of the patients, 16% reported that arthroplasty adversely affected sexual function, with their predominant fear being joint damage (63%). A greater number of women and patients undergoing hip procedures reported improvement in sexual activity after surgery compared with men (P=.02) and patients undergoing knee procedures (P=.002). Both hip and knee osteoarthritis and arthroplasty had a significant effect on overall sexual function-psychosocially, physically, and in terms of patients' assessment of their external appearance-with higher rates of improvement seen after hip arthroplasty. Because of the effect of osteoarthritis and arthroplasty on sexual function, this topic should be addressed both pre- and postoperatively. [Orthopedics. 2021;44(2):111-116.].


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Cadera/cirugía , Osteoartritis de la Rodilla/cirugía , Recuperación de la Función , Conducta Sexual/fisiología , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/fisiopatología , Osteoartritis de la Rodilla/fisiopatología , Periodo Posoperatorio , Estudios Prospectivos , Calidad de Vida , Encuestas y Cuestionarios
2.
J Arthroplasty ; 34(7S): S292-S296, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31010773

RESUMEN

BACKGROUND: Nonmodular and modular femoral stems have been associated with complications after revision total hip arthroplasty (rTHA). As such, the ideal femoral component for rTHA remains undecided. This study aims to report outcomes of titanium, tapered-fluted, modular and nonmodular femoral components in rTHA. METHODS: From January 1, 2013 to September 30, 2017, all rTHAs using modular or nonmodular femoral stems were identified. Demographic data including age, gender, and American Society of Anesthesiologists scores were collected. Surgical details including operative time and implant cost were also collected. Clinical outcomes including length of stay, dislocation, infection, fracture, reoperation, and re-revision were collected. Statistical analysis was performed using chi-square test and Student's t-test for all categorical and continuous variables, respectively. RESULTS: One hundred forty-six rTHA cases (103 modular and 43 nonmodular) were identified with an average follow-up of 29 months (range 3-59 months). Nonmodular stems had a significantly lower cost when compared to modular implants (modular stems 120.8% higher cost; P < .001). The surgical time of nonmodular components was significantly greater (193 minutes vs 163 minutes; P = .029). There were no differences observed in any other surgical details or clinical outcomes assessed, including length of stay (P = .323), rate of re-revision of the femoral implant (P = .389), rate of re-operation (P = .383), and postop complications (P = .241), including infection (P = .095), dislocation (P = .778), and fracture (P = .959). CONCLUSIONS: Nonmodular components provide encouraging clinical results with significantly lower costs compared to modular implants in rTHA. The use of titanium, tapered-fluted, nonmodular components may offer a more cost-effective approach to rTHA compared to their modular counterparts.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Prótesis de Cadera/estadística & datos numéricos , Complicaciones Posoperatorias/epidemiología , Diseño de Prótesis/estadística & datos numéricos , Anciano , Distribución de Chi-Cuadrado , Femenino , Fémur/cirugía , Fracturas Óseas/epidemiología , Fracturas Óseas/etiología , Prótesis de Cadera/efectos adversos , Humanos , Luxaciones Articulares , Masculino , Persona de Mediana Edad , Ciudad de Nueva York/epidemiología , Tempo Operativo , Complicaciones Posoperatorias/etiología , Diseño de Prótesis/efectos adversos , Reoperación/estadística & datos numéricos , Estudios Retrospectivos , Titanio
3.
J Clin Orthop Trauma ; 9(1): 29-33, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29628680

RESUMEN

INTRODUCTION: The rotating hinge prosthesis was originally used and designed as a primary total knee arthroplasty implant, but was hampered due to poor outcomes and catastrophic failures. Newer rotating hinge implants can be utilized in complex revision total knee arthroplasties when appropriately indicated, but their outcome data is very difficult to interpret due to the strict and varied indications for use and subsequently small number of procedures performed. The goal of this review is to evaluate the current evidence on large cohort, rotating hinge knee prostheses used in the revision setting, in order to provide a clearer understanding of the indications, outcomes and complications. METHODS: The PubMed database was utilized to search the available literature regarding "hinged knee," or "rotating hinge" devices. Exclusion criteria included papers focusing on primary arthroplasty, revision for oncologic issues, one-stage revision for infection or studies with less than fifty cases. RESULTS: Review of 115 abstracts after initial search, led to ten studies in the literature that met our inclusion and exclusion criteria. The data shows that rotating hinge knee implants have good survivorship ranging from 51% to 92.5% at 10 years post-operatively. Complication rates range from 9.2% to 63% with infection and aseptic loosening as the most common complications. CONCLUSION: Rotating hinge knee prostheses are most commonly indicated for infection, aseptic loosening, instability and bone loss in the literature. They have good outcome scores and survivorship, but continue to have high complication and revision rates. The implant is a good option when utilized appropriately for patients that are not candidates for less constrained devices.

5.
Knee Surg Sports Traumatol Arthrosc ; 24(10): 3194-3199, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25552405

RESUMEN

PURPOSE: The use of unlinked constrained condylar components (CCK) has been extended to primary total knee arthroplasty (TKA); however, there is limited literature on its outcomes. The purpose of this retrospective cohort study was to assess clinical outcomes of one particular design of primary, non-stemmed, unlinked constrained TKA and to compare them with a control group of PS-TKA utilizing the same implant design. METHODS: The clinical and radiographic outcomes of 486-cemented, non-stemmed, primary TKA's performed by two surgeons at one institution using similar surgical algorithm, technique and prosthetic design were retrospectively reviewed. Primary TKA components were used in all knees; the only difference between groups was the type of polyethylene inserts used (CCK vs PS). Pre-operative deformity, knee society scores (KSS), range-of-motion (ROM), radiographic data and revision rates were compared. RESULTS: Both groups had comparable demographics, pre-operative coronal plane alignment, ROM and KSS. At a mean follow-up of 3.5 years, no difference was found in ROM, KSS, radiographic outcomes and revision rates. CONCLUSIONS: Cemented, primary, non-stemmed CCK-TKA offered comparable clinico-radiographic results to PS-TKA at short-term follow-up. Use of a semi-constrained insert without additional stems did not predispose to failure due to aseptic loosening with this implant design. Moreover, the rate of revision due to instability was lowered. LEVEL OF EVIDENCE: Retrospective cohort study, Level III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla/efectos adversos , Diseño de Prótesis , Falla de Prótesis , Anciano , Cementos para Huesos , Estudios de Casos y Controles , Femenino , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Reoperación , Estudios Retrospectivos
6.
Orthop Clin North Am ; 46(3): 343-50, ix, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26043048

RESUMEN

Patient-specific instrumentation (PSI) in total knee arthroplasty (TKA) has been introduced to obtain consistent alignment, prevent instrumentation of the medullary canal and improve operating room efficiency. This article compares simultaneous bilateral TKA performed with and without the use of PSI in terms of surgical time; blood loss and transfusion requirements; length-of-stay, early thromboembolic events and complication rates. There was a trend to reduced total blood loss (as measured by drop in hemoglobin values) and lower transfusion rate after surgery. Further research in the form of high quality randomized trials and cost-benefit analyses may help in further consolidation of these findings.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Pérdida de Sangre Quirúrgica/prevención & control , Transfusión Sanguínea/métodos , Osteoartritis de la Rodilla/cirugía , Modelación Específica para el Paciente , Anciano , Artroplastia de Reemplazo de Rodilla/efectos adversos , Pérdida de Sangre Quirúrgica/fisiopatología , Estudios de Cohortes , Diseño Asistido por Computadora , Femenino , Estudios de Seguimiento , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/rehabilitación , Cuidados Posoperatorios , Falla de Prótesis , Radiografía , Estudios Retrospectivos , Medición de Riesgo , Factores de Tiempo , Resultado del Tratamiento
9.
Orthopedics ; 37(9): e768-74, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25350618

RESUMEN

Flexion instability in posterior-stabilized total knee arthroplasty is a relatively uncommon but distinct problem that is often underdiagnosed and may require surgical management. This retrospective study evaluated the authors' management strategy and assessed the results of revision surgery. The authors identified 19 knees that underwent revision for isolated flexion instability after primary posterior-stabilized total knee arthroplasty. All patients had typical symptoms and signs of flexion instability, which include diffuse pain, especially when negotiating stairs, a sense of instability without giving way, recurrent joint effusions, and diffuse periarticular tenderness. Knee Society scores were used to assess pain and function. Complete revision was performed in 11 knees, femoral revision with a thicker insert was performed in 1 knee, and isolated tibial polyethylene insert exchange was performed in 7 knees. Postoperatively, all patients reported improvement in instability symptoms and signs associated with improvement in mean Knee Society scores. Revision surgery with careful gap balancing is successful in the management of isolated flexion instability in posterior-stabilized total knee arthroplasty. Isolated tibial polyethylene insert exchange may have a role in selected patients where component malalignment and malrotation is ruled out and a thicker and/or semiconstrained insert can be used, while limiting the resultant flexion contracture to less than 5°.


Asunto(s)
Artritis/cirugía , Artroplastia de Reemplazo de Rodilla/efectos adversos , Inestabilidad de la Articulación/cirugía , Articulación de la Rodilla/cirugía , Anciano , Femenino , Humanos , Inestabilidad de la Articulación/etiología , Masculino , Persona de Mediana Edad , Rango del Movimiento Articular , Reoperación , Estudios Retrospectivos
10.
Clin Orthop Relat Res ; 472(6): 1877-85, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24549773

RESUMEN

BACKGROUND: The direct anterior approach for THA offers some advantages, but is associated with a significant learning curve. Some of the technical difficulties can be addressed by the use of intraoperative fluoroscopy which may improve the accuracy of acetabular component placement. QUESTIONS/PURPOSES: The purposes of this study were to determine if (1) there is decreased variability of acetabular cup inclination and anteversion with the direct anterior approach using fluoroscopic guidance as compared with the posterior approach THA without radiographic guidance; (2) if there is a learning curve associated with achieving accuracy with the direct anterior approach THA. We also wanted (3) to assess the frequency of complications including dislocation with the anterior approach, which initially had a learning curve, and the posterior approach. METHODS: This retrospective, comparative study of 825 THAs (372 posterior THAs without fluoroscopic guidance and 453 direct anterior THAs, performed by one surgeon, focused on a radiographic analysis to determine cup inclination and anteversion on standardized pelvic radiographs using specialized software. The first 100 direct anterior THAs performed while transitioning from the posterior approach to the direct anterior approach were included in the learning curve group. During this learning curve period, the direct anterior approach was used for all patients except those with conversion of previously fixed intertrochanteric or femoral neck fractures to THAs, gluteus medius tears, and obese patients with an immobile abdominal pannus (100 of 127 THAs). Variability of the acetabular component was compared among the posterior group, learning curve group, and direct anterior group. RESULTS: Variances for cup inclination and anteversion were significantly lower in the direct anterior group (19 and 16 respectively, p < 0.01) as compared with the posterior group (50 and 79 respectively).Target inclination and anteversion were achieved better in the direct anterior group (98% and 97% respectively) as compared with the posterior group (86% and 77% respectively) (p < 0.01, OR for inclination = 9.1, 95% CI, 3.5 to 23.4; OR for anteversion = 8, 95% CI, 4 to 16). In the learning curve group, target anteversion achieved (91% of cases) was marginally lower than that of the direct anterior group (p = 0.03; OR = 2.9, 95% CI, 1.1 to 7.3) and target inclination (95%) was similar (p = 0.13). There was one posterior dislocation in the posterior group, two anterior dislocations in the learning curve group, and none in the direct anterior group. CONCLUSIONS: Use of fluoroscopy with the patient in the supine position during direct anterior THA enables intraoperative assessment of cup orientation resulting in decreased variability of acetabular cup anteversion. However, there is a learning curve associated with achieving this accuracy. We could not discern whether this difference was the result of the approach or the use of fluoroscopy in the direct anterior group. LEVEL OF EVIDENCE: Level III, therapeutic study. See the Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/métodos , Articulación de la Cadera/cirugía , Radiografía Intervencional/métodos , Acetábulo/diagnóstico por imagen , Acetábulo/fisiopatología , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/instrumentación , Distribución de Chi-Cuadrado , Competencia Clínica , Femenino , Fluoroscopía , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/fisiopatología , Prótesis de Cadera , Humanos , Curva de Aprendizaje , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Posicionamiento del Paciente , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/prevención & control , Diseño de Prótesis , Falla de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Posición Supina , Factores de Tiempo , Resultado del Tratamiento
12.
J Arthroplasty ; 29(6): 1261-4, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24405621

RESUMEN

We compared gait parameters prior to, at 6 months and 1 year following total hip arthroplasty (THA) performed via direct anterior approach (DAA) and posterior approach (PA) by a single surgeon in 22 patients. A gait analysis system involving reflective markers, infrared cameras and a multicomponent force plate was utilized. Postoperatively, the study cohort demonstrated improvement in flexion/extension range of motion (ROM) (P = 0.001), peak flexion (P = 0.005) and extension (P = 0.002) moments with no differences between groups. Internal/external ROM improved significantly in the DAA group (P = 0.04) with no change in the PA group. THA performed via DAA and PA offers similar improvement in gait parameters with the exception of internal/external ROM which might be related to the release and repair of external rotators during PA THA.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Marcha , Osteoartritis de la Cadera/fisiopatología , Osteoartritis de la Cadera/cirugía , Anciano , Fenómenos Biomecánicos , Femenino , Articulación de la Cadera/fisiopatología , Articulación de la Cadera/cirugía , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Rango del Movimiento Articular , Recuperación de la Función
13.
Clin Orthop Relat Res ; 472(2): 455-63, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23963704

RESUMEN

BACKGROUND: Newer surgical approaches to THA, such as the direct anterior approach, may influence a patient's time to recovery, but it is important to make sure that these approaches do not compromise reconstructive safety or accuracy. QUESTIONS/PURPOSES: We compared the direct anterior approach and conventional posterior approach in terms of (1) recovery of hip function after primary THA, (2) general health outcomes, (3) operative time and surgical complications, and (4) accuracy of component placement. METHODS: In this prospective, comparative, nonrandomized study of 120 patients (60 direct anterior THA, 60 posterior THAs), we assessed functional recovery using the VAS pain score, timed up and go (TUG) test, motor component of the Functional Independence Measure™ (M-FIM™), UCLA activity score, Harris hip score, and patient-maintained subjective milestone diary and general health outcome using SF-12 scores. Operative time, complications, and component placement were also compared. RESULTS: Functional recovery was faster in patients with the direct anterior approach on the basis of TUG and M-FIM™ up to 2 weeks; no differences were found in terms of the other metrics we used, and no differences were observed between groups beyond 6 weeks. General health outcomes, operative time, and complications were similar between groups. No clinically important differences were observed in terms of implant alignment. CONCLUSIONS: We observed very modest functional advantages early in recovery after direct anterior THA compared to posterior-approach THA. Randomized trials are needed to validate these findings, and these findings may not generalize well to lower-volume practice settings or to surgeons earlier in the learning curve of direct anterior THA.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Articulación de la Cadera/cirugía , Actividades Cotidianas , Anciano , Análisis de Varianza , Artroplastia de Reemplazo de Cadera/efectos adversos , Fenómenos Biomecánicos , Distribución de Chi-Cuadrado , Evaluación de la Discapacidad , Femenino , Articulación de la Cadera/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/fisiopatología , Estudios Prospectivos , Recuperación de la Función , Factores de Riesgo , Encuestas y Cuestionarios , Factores de Tiempo , Resultado del Tratamiento
15.
Indian J Orthop ; 44(3): 300-7, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20697484

RESUMEN

BACKGROUND: Limb length discrepancy and its effects on patient function have been discussed in depth in the literature with respect to hip arthroplasty but there are few studies that have examined the effect on function of limb length discrepency following total knee arthroplasty (TKA). The aim of this study was to determine whether limb length discrepancy after TKA in patients with bilateral osteoarthritis of knee with varus deformity affects functional outcome. MATERIALS AND METHODS: Fifty-four patients with bilateral osteoarthritis of knee with varus deformity, who were operated for total knee arthroplasty from 1996 to 2008, were reviewed retrospectively. The patients were divided into two groups. Thirty patients (mean age 64 years) were operated for unilateral TKA and thirty patients (mean age 65.8 years) were operated for bilateral total knee arthroplasty. Six patients underwent staged surgery and were included in both groups as the time interval between the two surgeries was more than the minimum 6-month follow-up period specified for inclusion in the study. The limb length discrepancy was measured and statistically correlated with the functional component of the Knee Society Score. RESULT: In the unilateral group (n=30), the mean limb length discrepancy was 1.53 cm (range: 0-3 cm) and the mean functional score was 73 (range: 45-100). In the bilateral group (n=30), the mean limb length discrepancy was 0.5 cm (range: 0-2 cm) and the mean functional score was 80.67 (range: 0-100). A statistically significant negative correlation was found between limb length discrepancy and functional score in the unilateral group (Spearman correlation coefficient, r =-0.52, P=0.006), while no statistically significant correlation was found in the bilateral group (Spearman correlation coefficient, r = -0.141, P=0.458). CONCLUSION: Limb length discrepancy affects functional outcome after total knee arthroplasty, especially so in patients of bilateral osteoarthritis with varus deformity undergoing surgery of only one knee.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...