Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Radiat Res ; 62(3): 540-548, 2021 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-33839761

RESUMEN

The purpose of this study was to compare hybrid intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (Hybrid IMRT/VMAT), with non-coplanar (nc) IMRT and nc-VMAT treatment plans for unresectable olfactory neuroblastoma (ONB). Hybrid IMRT/VMAT, nc-IMRT and nc-VMAT plans were optimized for 12 patients with modified Kadish C stage ONB. Dose prescription was 65 Gy in 26 fractions. Dose-volume histogram parameters, conformation number (CN), homogeneity index (HI), integral dose and monitor units (MUs) delivered per fraction were assessed. Equivalent uniform dose (EUD) and normal tissue complication probability (NTCP) based on the EUD model (NTCPLogit) and the Lyman-Kutcher-Burman model (NTCPLKB) were also evaluated. We found that the Hybrid IMRT/VMAT plan significantly improved the CN for clinical target volume (CTV) and planning treatment volume (PTV) compared with the nc-VMAT plan. In general, sparing of organs at risk (OARs) is similar with the three techniques, although the Hybrid IMRT/VMAT plan resulted in a significantly reduced Dmax to contralateral (C/L) optic nerve compared with the nc-IMRT plan. The Hybrid IMRT/VMAT plan significantly reduce EUD to the ipsilateral (I/L) and C/L optic nerve in comparison with the nc-IMRT plan and nc-VMAT plan, but the difference in NTCP between the three technique was <1%. We concluded that the Hybrid IMRT/VMAT technique can offer improvement in terms of target conformity and EUD for optic nerves, while achieving equal or better OAR sparing compared with nc-IMRT and nc-VMAT, and can be a viable radiation technique for treating unresectable ONB. However, the clinical benefit of these small differences in dosimetric data, EUD and NTCP of optic nerves may be minimal.


Asunto(s)
Estesioneuroblastoma Olfatorio/radioterapia , Cavidad Nasal/patología , Cavidad Nasal/efectos de la radiación , Neoplasias Nasales/radioterapia , Probabilidad , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Adulto , Anciano , Anciano de 80 o más Años , Relación Dosis-Respuesta en la Radiación , Estesioneuroblastoma Olfatorio/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Cavidad Nasal/diagnóstico por imagen , Neoplasias Nasales/diagnóstico por imagen , Órganos en Riesgo/efectos de la radiación , Factores de Tiempo , Adulto Joven
2.
Front Oncol ; 10: 517061, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33194580

RESUMEN

Background: Radiobiological model-based studies of photon-modulated radiotherapy for pancreatic cancer have reported reduced gastrointestinal (GI) toxicity, although the risk is still high. The purpose of this study was to investigate the potential of 3D-passive scattering proton beam therapy (3D-PSPBT) in limiting GI organ at risk (OAR) toxicity in localized pancreatic cancer based on dosimetric data and the normal tissue complication probability (NTCP) model. Methods: The data of 24 pancreatic cancer patients were retrospectively analyzed, and these patients were planned with intensity-modulated radiotherapy (IMRT), volume-modulated arc therapy (VMAT), and 3D-PSPBT. The tumor was targeted without elective nodal coverage. All generated plans consisted of a 50.4-GyE (Gray equivalent) dose in 28 fractions with equivalent OAR constraints, and they were normalized to cover 50% of the planning treatment volume (PTV) with 100% of the prescription dose. Physical dose distributions were evaluated. GI-OAR toxicity risk for different endpoints was estimated by using published NTCP Lyman-Kutcher-Burman (LKB) models. Analysis of variance (ANOVA) was performed to compare the dosimetric data, and ΔNTCPIMRT-PSPBT and ΔNTCPVMAT-PSPBT were also computed. Results: Similar homogeneity and conformity for the clinical target volume (CTV) and PTV were exhibited by all three planning techniques (P > 0.05). 3D-PSPBT resulted in a significant dose reduction for GI-OARs in both the low-intermediate dose range (below 30 GyE) and the highest dose region (D max and V 50 GyE) in comparison with IMRT and VMAT (P < 0.05). Based on the NTCP evaluation, the NTCP reduction for GI-OARs by 3D-PSPBT was minimal in comparison with IMRT and VMAT. Conclusion: 3D-PSPBT results in minimal NTCP reduction and has less potential to substantially reduce the toxicity risk of upper GI bleeding, ulceration, obstruction, and perforation endpoints compared to IMRT and VMAT. 3D-PSPBT may have the potential to reduce acute dose-limiting toxicity in the form of nausea, vomiting, and diarrhea by reducing the GI-OAR treated volume in the low-to-intermediate dose range. However, this result needs to be further evaluated in future clinical studies.

3.
Radiat Oncol ; 15(1): 157, 2020 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-32571379

RESUMEN

BACKGROUND: The purpose of this study was to determine the potential of escalated dose radiation (EDR) robust intensity-modulated proton radiotherapy (ro-IMPT) in reducing GI toxicity risk in locally advanced unresectable pancreatic cancer (LAUPC) of the head in term of normal tissue complication probability (NTCP) predictive model. METHODS: For 9 patients, intensity-modulated radiotherapy (IMRT) was compared with ro-IMPT. For all plans, the prescription dose was 59.4GyE (Gray equivalent) in 33 fractions with an equivalent organ at risk (OAR) constraints. Physical dose distribution was evaluated. GI toxicity risk for different endpoints was estimated using published NTCP Lyman Kutcher Burman (LKB) models for stomach, duodenum, small bowel, and combine stomach and duodenum (Stoduo). A Wilcoxon signed-rank test was used for dosimetry parameters and NTCP values comparison. RESULT: The dosimetric results have shown that, with similar target coverage, ro-IMPT achieves a significant dose-volume reduction in the stomach, small bowel, and stoduo in low to high dose range in comparison to IMRT. NTCP evaluation for the endpoint gastric bleeding of stomach (10.55% vs. 13.97%, P = 0.007), duodenum (1.87% vs. 5.02%, P = 0.004), and stoduo (5.67% vs. 7.81%, P = 0.008) suggest reduced toxicity by ro-IMPT compared to IMRT. ∆NTCP IMRT - ro-IMPT (using parameter from Pan et al. for gastric bleed) of ≥5 to < 10% was seen in 3 patients (33%) for stomach and 2 patients (22%) for stoduo. An overall GI toxicity relative risk (NTCPro-IMPT/NTCPIMRT) reduction was noted (0.16-0.81) for all GI-OARs except for duodenum (> 1) with endpoint grade ≥ 3 GI toxicity (using parameters from Holyoake et al.). CONCLUSION: With similar target coverage and better conformity, ro-IMPT has the potential to substantially reduce the risk of GI toxicity compared to IMRT in EDR of LAUPC of the head. This result needs to be further evaluated in future clinical studies.


Asunto(s)
Tracto Gastrointestinal/efectos de la radiación , Neoplasias Pancreáticas/radioterapia , Terapia de Protones/métodos , Traumatismos por Radiación/etiología , Radioterapia de Intensidad Modulada/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Órganos en Riesgo , Terapia de Protones/efectos adversos , Radiobiología , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...