Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
JACC Heart Fail ; 12(3): 508-520, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38099890

RESUMEN

BACKGROUND: Individuals with acute decompensated heart failure (ADHF) have a varying response to diuretic therapy. Strategies for the early identification of low diuretic efficiency to inform decongestion therapies are lacking. OBJECTIVES: The authors sought to develop and externally validate a machine learning-based phenomapping approach and integer-based diuresis score to identify patients with low diuretic efficiency. METHODS: Participants with ADHF from ROSE-AHF, CARRESS-HF, and ATHENA-HF were pooled in the derivation cohort (n = 794). Multivariable finite-mixture model-based phenomapping was performed to identify phenogroups based on diuretic efficiency (urine output over the first 72 hours per total intravenous furosemide equivalent loop diuretic dose). Phenogroups were externally validated in other pooled ADHF trials (DOSE/ESCAPE). An integer-based diuresis score (BAN-ADHF score: blood urea nitrogen, creatinine, natriuretic peptide levels, atrial fibrillation, diastolic blood pressure, hypertension and home diuretic, and heart failure hospitalization) was developed and validated based on predictors of the diuretic efficiency phenogroups to estimate the probability of low diuretic efficiency using the pooled ADHF trials described earlier. The associations of the BAN-ADHF score with markers and symptoms of congestion, length of stay, in-hospital mortality, and global well-being were assessed using adjusted regression models. RESULTS: Clustering identified 3 phenogroups based on diuretic efficiency: phenogroup 1 (n = 370; 47%) had lower diuretic efficiency (median: 13.1 mL/mg; Q1-Q3: 7.7-19.4 mL/mg) than phenogroups 2 (n = 290; 37%) and 3 (n = 134; 17%) (median: 17.8 mL/mg; Q1-Q3: 10.8-26.1 mL/mg and median: 35.3 mL/mg; Q1-Q3: 17.5-49.0 mL/mg, respectively) (P < 0.001). The median urine output difference in response to 80 mg intravenous twice-daily furosemide between the lowest and highest diuretic efficiency group (phenogroup 1 vs 3) was 3,520 mL/d. The BAN-ADHF score demonstrated good model performance for predicting the lowest diuretic efficiency phenogroup membership (C-index: 0.92 in DOSE/ESCAPE validation cohort) that was superior to measures of kidney function (creatinine or blood urea nitrogen), natriuretic peptide levels, or home diuretic dose (DeLong P < 0.001 for all). Net urine output in response to 80 mg intravenous twice-daily furosemide among patients with a low vs high (5 vs 20) BAN-ADHF score was 2,650 vs 660 mL per 24 hours, respectively. Participants with higher BAN-ADHF scores had significantly lower global well-being, higher natriuretic peptide levels on discharge, a longer in-hospital stay, and a higher risk of in-hospital mortality in both derivation and validation cohorts. CONCLUSIONS: The authors developed and validated a phenomapping strategy and diuresis score for individuals with ADHF and differential response to diuretic therapy, which was associated with length of stay and mortality.


Asunto(s)
Diuréticos , Insuficiencia Cardíaca , Humanos , Diuréticos/uso terapéutico , Furosemida/uso terapéutico , Creatinina , Péptidos Natriuréticos , Enfermedad Aguda
3.
JACC Heart Fail ; 11(12): 1692-1704, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37831046

RESUMEN

BACKGROUND: Left ventricular assist devices (LVADs) are underused among women with advanced heart failure, but reasons remain unclear. Outcomes in women compared with men with contemporary fully magnetically levitated LVADs remain uncertain. OBJECTIVES: The authors examined differences in characteristics, 2-year outcomes, and risk for key adverse events among women and men. METHODS: In 2,200 HeartMate3 (HM3) (Abbott Cardiovascular) LVAD recipients in the MOMENTUM 3 study (Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy with HeartMate 3), survival free of disabling stroke or reoperation to replace or remove a malfunctioning pump at 2 years was analyzed between women and men. Other outcomes included overall 2-year survival, adverse events, and functional measures. RESULTS: Women comprised 20.4% (n = 448 of 2,200) of the study population and were younger, with nonischemic cardiomyopathy, and more often were Black persons compared with men. The primary endpoint (women 79.4% vs men 75.5% (adjusted [a]HR: 0.96 [95% CI: 0.75-1.24]; P = 0.66) or survival at 2 years (women 82.4% vs men 80.2%; aHR: 1.06 [95% CI: 0.81-1.40]; P = 0.66) was no different. Women had an increased rate of stroke (adjusted incidence rate ratio [aIRR]: 1.52 [95% CI: 1.09-2.11]; P = 0.012), major bleeding (aIRR: 1.28 [95% CI: 1.15-1.42]; P < 0.0001) and infection (aIRR 1.14 [95% CI: 1.03-1.55]; P = 0.01), but these differences were not seen among older (>65 years) patients. Both groups had similar gains in 6-minute walk distance and quality-of-life measurements. CONCLUSIONS: There were no differences in the primary composite endpoint or overall survival in women compared with men at 2 years of support. Reasons underlying increase in hemocompatibility-related events and infection-related morbidity in younger women deserves further study. (MOMENTUM 3 IDE [HM3], NCT02224755; MOMENTUM 3 Continued Access Protocol [MOMENTUM 3 CAP], NCT02892955).


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Accidente Cerebrovascular , Masculino , Humanos , Femenino , Corazón Auxiliar/efectos adversos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Reoperación/efectos adversos , Resultado del Tratamiento
4.
Circ Heart Fail ; 14(10): e008360, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34525837

RESUMEN

BACKGROUND: Heart failure disproportionately affects Black patients. Whether differences among race influence outcomes in advanced heart failure with use of a fully magnetically levitated continuous-flow left ventricular assist device remains uncertain. METHODS: We included 515 IDE (Investigational Device Exemption) clinical trial patients and 500 Continued Access Protocol patients implanted with the HeartMate 3 left ventricular assist device in the MOMENTUM 3 study (Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3). Outcomes were compared between Black and White left ventricular assist device recipients for the primary end point of survival free of disabling stroke or reoperation to replace or remove a malfunctioning device at 2 years, overall survival, adverse events, 6-minute walk distance, and quality of life scores. RESULTS: Of 1015 HeartMate 3 patients, 675 were self-identified as White and 285 as Black individuals. The Black patient cohort was younger, more obese and with a history of hypertension, and more nonischemic cause of heart failure, relative to the White patient group. Black and White patients did not experience a difference in the primary end point (81.1% versus 77.9%; hazard ratio, 1.08 [95% CI, 0.76-1.54], P=0.6568). Black patients were at higher risk of adverse events (calculated as events per 100 patient-years), including bleeding (75.4 versus 63.5; P<0.0001), stroke (9.5 versus 7.2; P=0.0183), and hypertension (10.1 versus 3.2; P<0.0001). The 6-minute walk distance was not different at baseline and 6 months between the groups, however, the absolute change from baseline was greater for White patients (median: +183.0 [interquartile range, 42.0-335.3] versus +163.8 [interquartile range, 42.3-315.0] meters, P=0.01). The absolute quality of life measurement (EuroQoL group, 5-dimension, 5-level instrument visual analog scale) at baseline and 6 months was better in the Black patient group, but relative improvement from baseline to 6 months was greater in White patients (median: +20.0 [interquartile range, 5.0-40.0] versus +25.0 [interquartile range, 10.0-45.0]; P=0.0298). CONCLUSIONS: Although the survival free of disabling stroke or reoperation to replace/remove a malfunctioning device at 2 years with the HM 3 left ventricular assist device did not differ by race, Black HeartMate 3 patients experienced a higher morbidity burden and smaller gains in functional capacity and quality of life when compared with White patients. These findings require efforts designed to better understand and overcome these gaps through systematic identification and tackling of putative factors. Registration: URL: https://www.clinicaltrials.gov; Unique identifiers: NCT02224755 and NCT02892955.


Asunto(s)
Ensayos Clínicos como Asunto , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Accidente Cerebrovascular/etiología , Resultado del Tratamiento , Adulto , Insuficiencia Cardíaca/fisiopatología , Corazón Auxiliar/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Calidad de Vida , Reoperación/efectos adversos , Accidente Cerebrovascular/terapia
6.
J Cardiovasc Electrophysiol ; 32(2): 325-332, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33270311

RESUMEN

INTRODUCTION: Elevated left atrial pressure (LAP) during catheter ablation of atrial fibrillation (AF) is associated with an increased risk of AF recurrence, but it is unknown if this correlates with heart failure (HF). The objective of the study was to determine if elevated LAP after AF ablation correlates with HF events. METHODS: Prospective, single-center, cohort study measuring LAP and right atrial pressure (RAP) during AF ablation in 100 patients. The primary endpoint was clinical HF within 30 days of ablation. The secondary outcome was AF-free HF. RESULTS: One hundred patients (63% male, mean age 64.5) were enrolled and 20% had clinical HF within 30 days. Bivariate correlates included mitral valve (MV) disease, persistent AF, class III antiarrhythmics, LAP, and recurrent AF. Multivariate analysis revealed class III antiarrhythmics were protective (odds ratio [OR]: 0.24 [0.1-0.5], p = .04), while MV disease (OR: 8.7 [3.3-23], p = .03) and loop diuretics (OR: 4.8 [2.6-9.1], p = .01) were hazardous. AF-free HF occurred in 9% of patients and correlated with higher LAP and RAP, and chronic kidney disease. CONCLUSION: Patients with HF after AF ablation had higher LAP. MV disease, diuretic use, and class III antiarrhythmics also correlated to HF. These present opportunities to target future interventions to reduce a common complication of AF ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Insuficiencia Cardíaca , Hipertensión , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Estudios de Cohortes , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Recurrencia , Resultado del Tratamiento
7.
JACC Clin Electrophysiol ; 7(4): 494-501, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33358671

RESUMEN

OBJECTIVES: The objective of this study was to describe the risk of cardiac implantable electronic devices (CIEDs) complications in patients with left ventricular assist devices (LVADs). BACKGROUND: Patients with LVADs are predisposed to ventricular arrhythmias and frequently have CIEDs before receiving their LVAD. However, the role of CIED procedures such as generator changes (GC) are unclear in this population, given the potential complications of bleeding and infection. METHODS: This was a retrospective, multicenter study from January 1, 2012, to September 30, 2018. All patients with LVADs were screened and those who had a CIED GC, implantation, or revision were included in the study and followed until December 31, 2018. RESULTS: A total of 179 patients across 6 centers had a CIED procedure after LVAD implantation. The mean age was 59.5 ± 13.4, with the cohort comprising mostly men (78%), destination LVAD therapy (53.8%), and GC (66%). The 30-day primary composite endpoint of hematoma or device infection occurred in 34 (19%) patients. The secondary endpoints of rehospitalization within 30 days and appropriate device therapy during follow-up occurred in 40 (22%) and 42 (24%) patients respectively. Of the 126 patients without previous device therapy, 14.3% received appropriate therapy during follow-up. CONCLUSIONS: In this large, multicenter cohort, we report the incidence of complications for CIED procedures in the LVAD population; specifically, LVAD patients are at increased risk of pocket hematomas, without downstream risk of infection, and do experience a high rate of appropriate device therapies.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Electrónica , Insuficiencia Cardíaca/epidemiología , Corazón Auxiliar/efectos adversos , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
8.
J Cardiothorac Surg ; 15(1): 329, 2020 Nov 14.
Artículo en Inglés | MEDLINE | ID: mdl-33189134

RESUMEN

BACKGROUND: Left ventricular assist devices (LVAD) have been increasingly used in the treatment of end-stage heart failure. While warfarin has been uniformly recommended in the long-term as anticoagulation strategy, no clear recommendation exists for the post-operative period. We sought to evaluate the feasibility of enoxaparin in the immediate and early postoperative period after LVAD implantation. METHODS: This is a two-center, retrospective analysis of 250 consecutive patients undergoing LVAD implantation between January 2017 and December 2018. Patients were bridged postoperatively to therapeutic INR by either receiving unfractionated heparin (UFH) or low molecular weight heparin (LMWH). Patients were followed while inpatient and for 3 months after LVAD implantation. The efficacy outcome was occurrence of first and subsequent cerebrovascular accident while safety outcome was the occurrence of bleeding events. Length of stay (LOS) was also assessed. RESULTS: Two hundred fifty and 246 patients were analyzed for index admission and 3-month follow up respectively. No statistically significant differences were found between the two groups in CVA (OR = 0.67; CI = 0.07-6.39, P = 0.73) or bleeding events (OR = 0.91; CI = 0.27-3.04, P = 0.88) during index admission. Similarly, there were no differences at 3 months in either CVAs or bleeding events (OR = 0.85; 0.31-2.34; p = 0.76). No fatal events occurred during the study follow-up period. Median LOS was significantly lower (4 days; p = 0.03) in the LMWH group. CONCLUSIONS: LMWH in the immediate and early postoperative period after LVAD implantation appears to be a concurrently safe and efficacious option allowing earlier postoperative discharge and avoidance of recurrent hospitalizations due to sub-therapeutic INR.


Asunto(s)
Anticoagulantes/uso terapéutico , Enoxaparina/uso terapéutico , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Heparina de Bajo-Peso-Molecular/uso terapéutico , Heparina/uso terapéutico , Anticoagulantes/administración & dosificación , Esquema de Medicación , Enoxaparina/administración & dosificación , Femenino , Heparina/administración & dosificación , Heparina de Bajo-Peso-Molecular/administración & dosificación , Humanos , Indiana , Relación Normalizada Internacional , Kansas , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Estudios Retrospectivos
9.
Heart Fail Rev ; 25(6): 1089-1097, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-33025415

RESUMEN

In this document, we outline the challenges faced by patients and clinicians in heart failure, specifically centered around the needed coordination of care among the various subspecialties within cardiovascular medicine. We call for a more organized and collaborative effort among clinicians in primary care, general cardiology, electrophysiology, interventional cardiology, cardiothoracic surgery, cardiac imaging, and heart failure-all caring for mutual patients. Care is contextualized within the framework of two phases: a cardiomyopathy phase and an advanced heart failure phase, each of which lends to different considerations in therapy. Ultimately multidisciplinary coordinated care within cardiovascular medicine may lead to greater patient and clinician satisfaction as well as improved outcomes, but this remains to be investigated.


Asunto(s)
Técnicas de Imagen Cardíaca , Cardiología/métodos , Manejo de la Enfermedad , Insuficiencia Cardíaca/diagnóstico , Atención Primaria de Salud/métodos , Insuficiencia Cardíaca/terapia , Humanos
10.
JACC Case Rep ; 2(9): 1365-1367, 2020 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-32835281

RESUMEN

Shared decision making with patients in advanced heart failure is critical when making decisions on therapies such as left ventricular assist device implantation and cardiac transplantation. We describe a case wherein the risks of coronavirus disease-2019 affected the decision of a patient regarding proceeding with cardiac transplantation. (Level of Difficulty: Beginner.).

12.
JAMA Cardiol ; 5(4): 411-419, 2020 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-31939996

RESUMEN

Importance: Left ventricular assist devices (LVADs) are well established in the treatment of advanced heart failure, but it is unclear whether outcomes are different based on the intended goal of therapy in patients who are eligible vs ineligible for heart transplant. Objective: To determine whether clinical outcomes in the Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 (MOMENTUM 3) trial differed by preoperative categories of bridge to transplant (BTT) or bridge to transplant candidacy (BTC) vs destination therapy (DT). Design, Setting, and Participants: This study was a prespecified secondary analysis of the MOMENTUM 3 trial, a multicenter randomized clinical trial comparing the magnetically levitated centrifugal-flow HeartMate 3 (HM3) LVAD to the axial-flow HeartMate II (HMII) pump. It was conducted in 69 centers with expertise in managing patients with advanced heart failure in the United States. Patients with advanced heart failure were randomized to an LVAD, irrespective of the intended goal of therapy (BTT/BTC or DT). Main Outcomes and Measures: The primary end point was survival free of disabling stroke or reoperation to remove or replace a malfunctioning device at 2 years. Secondary end points included adverse events, functional status, and quality of life. Results: Of the 1020 patients with implants (515 with HM3 devices [50.5%] and 505 with HMII devices [49.5%]), 396 (38.8%) were in the BTT/BTC group (mean [SD] age, 55 [12] years; 310 men [78.3%]) and 624 (61.2%) in the DT group (mean [SD] age, 63 [12] years; 513 men [82.2%]). Of the patients initially deemed as transplant ineligible, 84 of 624 patients (13.5%) underwent heart transplant within 2 years of LVAD implant. In the primary end point analysis, HM3 use was superior to HMII use in patients in the BTT/BTC group (76.8% vs 67.3% for survival free of disabling stroke and reoperation; hazard ratio, 0.62 [95% CI, 0.40-0.94]; log-rank P = .02) and patients in the DT group (73.2% vs 58.7%; hazard ratio, 0.61 [95% CI, 0.46-0.81]; log-rank P < .001). For patients in both BTT/BTC and DT groups, there were not significantly different reductions in rates of pump thrombosis, stroke, and gastrointestinal bleeding with HM3 use relative to HMII use. Improvements in quality of life and functional capacity for either pump were not significantly different regardless of preimplant strategy. Conclusions and Relevance: In this trial, the superior treatment effect of HM3 over HMII was similar for patients in the BTT/BTC or DT groups. It is possible that use of arbitrary categorizations based on current or future transplant eligibility should be clinically abandoned in favor of a single preimplant strategy: to extend the survival and improve the quality of life of patients with medically refractory heart failure. Trial Registration: ClinicalTrials.gov identifier: NCT02224755.


Asunto(s)
Insuficiencia Cardíaca/cirugía , Trasplante de Corazón , Corazón Auxiliar , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Falla de Equipo , Femenino , Insuficiencia Cardíaca/mortalidad , Corazón Auxiliar/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Planificación de Atención al Paciente , Calidad de Vida , Reoperación/estadística & datos numéricos , Análisis de Supervivencia , Resultado del Tratamiento , Adulto Joven
13.
ASAIO J ; 65(5): e50-e51, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30507845

RESUMEN

The Dor procedure was historically used to restore the geometry of the heart in a patient with a left ventricular (LV) aneurysm via reduction and reshaping of the LV with an aneurysmectomy. Unfortunately, morbidity and mortality remain high with this procedure, with many patients little to no recovery of their ejection fraction while developing severe diastolic failure, often requiring further support; however, the natural history of these patients remains largely unknown. Heart transplant has long been considered the most durable of treatment for patients with end-stage heart failure (HF), but because of the scarcity of donor hearts, the implantation of left ventricular assist devices (LVAD) for mechanical circulatory support has also proven to be an essential tool in the treatment of the advanced heart failure patient. While various techniques for LVAD implantation have been well outlined, there is very limited literature on placement of a VAD in patients with a history of LV aneurysmectomy or Dor procedures, particularly with regard to the challenging aspects of apical cannulation in those with prior apical ventriculotomy and patch placement. In this series, we describe three patients with a history of LV aneurysmectomy procedures who underwent Heartware ventricular assist device (HVAD) implantations for end-stage HF.


Asunto(s)
Procedimientos Quirúrgicos Cardiovasculares , Aneurisma Cardíaco/cirugía , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Anciano , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
14.
J Cardiovasc Electrophysiol ; 29(3): 477-481, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29364552

RESUMEN

A 25-year-old man with severe nonischemic dilated cardiomyopathy underwent subcutaneous implantable cardioverter defibrillator (S-ICD) implant and subsequently underwent HeartWare ventricular assist device (HVAD) placement. Postoperative interrogation revealed both primary and secondary S-ICD vectors inappropriately regarded sinus rhythm as "noise," and the alternate vector significantly undersensed sinus rhythm. The S-ICD was reinterrogated using high-resolution capture to visually confirm EMI with a dominant frequency in both the primary and secondary vectors of 46.67 Hz that fell within the S-ICD operational range of 9-60 Hz. The 46.67 Hz frequency correlated with the HVAD operational speed of 2,800 RPM. The HVAD pump speed was increased from 2,800 to 3,000 RPM, resulting in a dominant frequency of 50 Hz. The notch filter is nonprogrammable in S-ICDs. However, the built-in filter is 50 Hz for countries in European time zones as opposed to 60 Hz in US time zones due to differences in the anticipated noise from electrical sources within each continent. Thus, the S-ICD time zone was reprogrammed from EST to GMT, which reduced the notch filter from 60  to 50 Hz, resulting in S-ICD successfully eliminating EMI when the patient was in a supine position. The EMI interference was still intermittently present in the upright patient position. This case demonstrates the utility of high-resolution electrogram capture to identify the source and frequency of EMI in S-ICD and offers a potential avenue to troubleshoot dominant frequency oversensing by changing the device time zone.


Asunto(s)
Cardiomiopatía Dilatada/terapia , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Campos Electromagnéticos , Corazón Auxiliar , Falla de Prótesis , Disfunción Ventricular Izquierda/terapia , Función Ventricular Izquierda , Adulto , Cardiomiopatía Dilatada/diagnóstico , Cardiomiopatía Dilatada/fisiopatología , Técnicas Electrofisiológicas Cardíacas , Humanos , Masculino , Posicionamiento del Paciente/métodos , Diseño de Prótesis , Posición Supina , Resultado del Tratamiento , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/fisiopatología
15.
ASAIO J ; 64(2): 280-281, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-28692527

RESUMEN

Right heart failure is a potentially devastating complication of mechanical circulatory support, occurring at a rate of 0.49 events per 100 patient-months. Pulmonary vasodilators such as phosphodiesterase-5 inhibitors (PDE5i) have been frequently used to unload the right ventricle in left ventricular assist device (LVAD) patients, but there is scant evidence to support this practice., The purpose of this analysis is to provide additional data regarding the safety and efficacy of the PDE5i sildenafil in a real world population of patients supported with LVADs at Washington University in St. Louis. Sildenafil use was not associated with differences in gastrointestinal (GI) bleeding, stroke, mortality, heart failure (HF) admission, or orthotopic heart transplantation (OHT).


Asunto(s)
Insuficiencia Cardíaca/tratamiento farmacológico , Insuficiencia Cardíaca/etiología , Corazón Auxiliar/efectos adversos , Citrato de Sildenafil/uso terapéutico , Vasodilatadores/uso terapéutico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
16.
ASAIO J ; 64(6): 721-726, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29117042

RESUMEN

Highly specialized left ventricular assist device care is not readily available in many areas, potentially limiting access to therapy. This retrospective analysis examines the relationship of outcomes by patient distance from implanting left ventricular assist device center within the Mechanical Circulatory Support Research Network. Zip codes were used to calculate patient distance, with the primary outcome of interest being 3-year survival by distance from the surgical center. Secondary outcomes included 90-day survival and incident event rates for the following: gastrointestinal bleeding, infection, cerebral event, and pump thrombosis. Across the four centers, there were 1184 patients supported for a median of 486 days. Overall survival was 91 ± 0.8% at 90 days and 61 ± 1.9% at 3 years, with worse 3-year survival in those living >90 vs. ≤90 miles from the ventricular assist device implant center (55 ± 3.0% vs. 64 ± 2.5, p = 0.019). Patients living >90 miles from an implant center were older, more likely to be implanted for destination therapy support, had a prior sternotomy, and had worse renal function than those living closer (p <0.05 for all). After adjusting for these factors, albumin and center of implant, the hazard ratio did not reach statistical significance (hazard ratio = 1.2; p = 0.14). Except for gastrointestinal bleeding, the event rates for the secondary outcomes were higher for those living closer to the implanting center. Protocols should be designed for more frequent follow-up and increased shared care opportunities to ensure optimal outcomes are achieved in distant patients.


Asunto(s)
Accesibilidad a los Servicios de Salud , Corazón Auxiliar , Resultado del Tratamiento , Anciano , Femenino , Insuficiencia Cardíaca/terapia , Corazón Auxiliar/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/mortalidad , Modelos de Riesgos Proporcionales , Estudios Retrospectivos
17.
ASAIO J ; 64(6): 748-753, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29210772

RESUMEN

The aims of this analysis were to characterize the burden and timing of bleeding events in females versus males on left ventricular assist device (LVAD) support. A single-center retrospective review of 375 patients receiving continuous-flow LVADs was performed. Bleeding events included gastrointestinal, naso-oropharyngeal, gynecologic (GYN), intracranial hemorrhage (ICH), and mediastinal bleeding. Cox hazard ratios (HRs) [95% CI] and incident event rates for females versus males were calculated. Eighty-four females (22%) and 291 males (78%) received an LVAD. There were 189 patients with 406 bleeding events over a median 399 days of support. Two-year freedom from bleeding was 33 ± 6.2% in females and 46 ± 3.7% in males (p = 0.027). Correlates of bleeding included female sex (adjusted HR = 1.6 [1.1-2.2]) and older age (adjusted HR = 1.2 [1.1-1.3] per 10 years). There was no sex-associated difference in 30 day mediastinal bleeding (males 12%; females 16% at 30 days; overall p = 0.35), but incident event rates for overall bleeding and naso-oropharyngeal bleeding were higher in females (p < 0.05) and trends were noted in ICH (eppy: 0.06 male vs. 0.10 female, p = 0.14). Eight females (10%) experienced 12 GYN bleeding events; five required surgical intervention. In summary, females had a 60% higher hazard of bleeding than males with significant morbidity encountered from mucosa (including vaginal) bleeding. Future large device studies should be inclusive of sex-specific outcomes.


Asunto(s)
Corazón Auxiliar/efectos adversos , Hemorragia Posoperatoria/epidemiología , Hemorragia Posoperatoria/etiología , Adulto , Anciano , Femenino , Insuficiencia Cardíaca/cirugía , Humanos , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Factores Sexuales
18.
ASAIO J ; 64(4): 570-572, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29095736

RESUMEN

Recently, a percutaneous right ventricular assist device (RVAD) called the TandemLife Protek Duo (TPD; TandemLife, Pittsburgh, PA) has been introduced. The Protek Duo (TPD) is a temporary RVAD placed via the right internal jugular vein, capable of providing up to 4.5 L of flow. We report a two-center experience using the TPD in 17 patients with right ventricular (RV) failure, 12 of whom were post-left ventricular assist device (LVAD) implantation.


Asunto(s)
Corazón Auxiliar , Disfunción Ventricular Derecha/cirugía , Femenino , Insuficiencia Cardíaca/cirugía , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
20.
J Thorac Dis ; 7(12): 2080-7, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26793327

RESUMEN

Mechanical circulatory support (MCS) and left ventricular assist device (LVAD) implantation is becoming increasingly utilized in the advanced heart failure (HF) population. Until further developments are made in this continually evolving field, the need for appropriate patient selection is fueled by our knowledge that the less sick do better. Due to the evolution of MCS technology, and the importance of patient selection to outcomes, risk scores and classification schemes have been developed to provide a structure for medical decision making. As clinical experience grows, technology improves, and further favorable clinical characteristics are identified, it is incumbent upon the HF community to continually hone these instruments. The magnitude of such tools cannot be understated when it comes to aiding in the informed consent and shared-decision making process for patients, families, and the healthcare team. Many risk models that have attempted to address which groups of patients will be successful focus on short term mortality and not long term survival or quality of life. The benefits and pitfalls of these models and their potential implications for patient selection and MCS therapy will be reviewed here.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...