Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
J Card Surg ; 37(9): 2581-2585, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35726656

RESUMEN

BACKGROUND AND AIM OF THE STUDY: Periareolar minithoracotomy represents an interesting option in minimally invasive cardiac surgery and it is our preferred approach for women. Our aim is to assess the results in female patients, in terms of nipple postoperative pain, local sensitivity, and eventual alterations in mammography after surgery. METHODS: Fifty-seven female patients underwent periareolar incision, as minithoracotomy approach, from December 2018 to December 2021. Their mean age was 56 ± 12 years, their body mass index was 22.5 ± 4.8; their surgery was elective in 93%, with mean Euroscore II about 2 ± 1.3. RESULTS: Of 57 patients, 87.7% (50 patients) underwent mitral valve repair, whose six with associated procedures; 8.8% (five patients) underwent mitral valve replacement whose two with tricuspid annuloplasty associated and 3.5% (two patients) had isolated tricuspid surgery. The cardiopulmonary bypass and aortic cross-clamp time were 123.2 ± 30.2 and 101.3 ± min respectively. There were no conversions to either full sternotomy or larger thoracotomy approach. There were no in-hospital and follow-up deaths. No strokes or wound infections were observed. Mean follow-up was 16± 9 months. Within the investigated follow-up, 100% of the patients were satisfied with the esthetic result, no remarkable postoperative pain was reported, two patients had slight hyposensitivity in the nipple area. About 50% IThad mammography as prevention screening after surgery and no abnormalities were found. CONCLUSIONS: Periareolar minithoracotomy is a feasible surgical option in female patients, with excellent healing and cosmetic results and preserving the tissues of the mammary gland.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Adulto , Anciano , Procedimientos Quirúrgicos Cardíacos/métodos , Femenino , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Dolor Postoperatorio , Estudios Retrospectivos , Toracotomía/métodos , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía
2.
Interact Cardiovasc Thorac Surg ; 33(4): 637-639, 2021 10 04.
Artículo en Inglés | MEDLINE | ID: mdl-33912969

RESUMEN

The present case highlights the crucial role of hybrid setting for diagnosis and treatment of refractory coronary spasms.


Asunto(s)
Vasoespasmo Coronario , Angiografía Coronaria , Vasoespasmo Coronario/diagnóstico por imagen , Vasoespasmo Coronario/terapia , Humanos , Espasmo
3.
Rev. bras. cir. cardiovasc ; 36(1): 125-129, Jan.-Feb. 2021. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1155789

RESUMEN

Abstract Although aortic valve replacement remains the gold standard treatment for aortic valve diseases like stenosis (AS) or insufficiency, new surgical methods have been developed with a focus in the reconstruction of the aortic valve rather than replacing it. The Ozaki procedure involves a tailored replacement of each individual valvular leaflet with glutaraldehyde-treated autologous pericardium and aims to reproduce the normal anatomy of the aortic valve. Cases of patients with unicuspid aortic valve treated with the Ozaki procedure are uncommon in the litrature and become even more rare when it comes to concomitant diseases like AS and ascending aorta aneurysm. We present the case of a 21-year-old, fit and asymptomatic male, with unicuspid aortic valve with severe stenosis and ascending aorta dilatation, surgically treated with tricuspidization of the aortic valve with glutaraldehyde-treated autologous pericardium and replacement of the ascending aorta with a straight synthetic graft. Postoperative studies showed a fully functional, neo-tailored tricuspid aortic valve with trivial regurgitation. The patient had an uncomplicated recovery, stayed in the intensive care unit for 2 days and was discharged on the 7th postoperative day.


Asunto(s)
Humanos , Masculino , Adulto , Adulto Joven , Aneurisma de la Aorta/cirugía , Aneurisma de la Aorta/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas , Aorta , Válvula Aórtica/cirugía
4.
J Card Surg ; 36(3): 872-878, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33442932

RESUMEN

AIMS: Transaortic (TAo) and transapical (TA) implantation can be used in transcatheter aortic valve implantation (TAVI) when the transfemoral (TF) approach is precluded. We compare the safety and efficacy of these alternative techniques. METHODS: From October 2007 to February 2016, TAo and TA patients' data were collected. Propensity score inverse probability of treatment weight (IPTW) method was employed to minimize the impact of no-randomization bias. RESULTS: From our single-center non-TF-TAVI registry, 282 patients were included: 235 (83.3%) underwent TAo and 47 (16.7%) TA. Differences in baseline characteristics were statistically significant in age, sex, risk profile according to logistic-EuroSCORE, and previous cardiac surgery. No difference in hospital morbidity and mortality, but lower stroke-rate in TAo (1.27% vs. 8.5% p < .01) was observed. This was confirmed at logistic regression after IPTW adjustment (odds ratio [OR]: 0.16, 95% CI 0.03-0.71, p = .01), together with reduced risk of the paravalvular leak (PVL) (OR: 0.14, 95% confidence interval [CI]: 0.02-0.81, p = .02). Kaplan-Meier estimates did not demonstrate differences in long-term mortality among access routes (logrank test p = .13). At the IPTW-Cox regression model, long-term mortality was related to New York Heart Association III-IV (hazard ratio [HR]: 2.92, 95% CI: 1.15-7.40, p = .026), chronic renal failure (HR: 3.25; 95% CI: 1.02-10.32 p = .046), previous transient ischemic attack/stroke (HR: 2.29, 95% CI: 1.25-4.20 p = .007). Sapien-3 device resulted to be a protective factor, reducing long-term mortality (HR: 0.18, 95% CI 0.04- 0.90 p = .03). CONCLUSIONS: TAo is safe and feasible in case of contraindication to femoral approach demonstrating comparable midterm outcomes to TA, thus representing a central access alternative, to increase the overall safety of high-risk TAVI procedures.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Cateterismo Cardíaco , Humanos , New York , Puntaje de Propensión , Factores de Riesgo , Resultado del Tratamiento
5.
J Card Surg ; 36(3): 1120-1122, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33428264

RESUMEN

In the last decades, the overlapping areas of intervention between cardiac surgeons and interventional cardiologists are rocketing, especially in the field of treatment of heart valve disease. But, while for the aortic valve the competition, even for nonhigh risk patients, has become tightened, in the context of mitral regurgitation, the surgery seems to not have competitors. In fact looking the results of studies published so far, a question arises: Is surgery the fair competitor for the Mitraclip? The meta-analysis by Abdul Khader et al. summarized few evidences present in this field, only 11 observational studies and 1 randomized trial, providing an awesome response: "NO." Is therefore not a case if recently two trials, MITRA-FR and COAPT, chose to use as competitor for MitraClip, more rightly, medical therapy instead of surgery. In conclusions, in case of mitral regurgitation (MR), surgery is still largely the gold standard treatment and so MitraClip cannot be mention at all as competitor of surgery. It can be the right choice of case of primary MR where patients showed high risk for surgery. In case of secondary MR, especially with large and poor left ventricle we should wait for a clear answer on its role, yet.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Ventrículos Cardíacos , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento
6.
Braz J Cardiovasc Surg ; 36(1): 125-129, 2021 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-33355794

RESUMEN

Although aortic valve replacement remains the gold standard treatment for aortic valve diseases like stenosis (AS) or insufficiency, new surgical methods have been developed with a focus in the reconstruction of the aortic valve rather than replacing it. The Ozaki procedure involves a tailored replacement of each individual valvular leaflet with glutaraldehyde-treated autologous pericardium and aims to reproduce the normal anatomy of the aortic valve. Cases of patients with unicuspid aortic valve treated with the Ozaki procedure are uncommon in the litrature and become even more rare when it comes to concomitant diseases like AS and ascending aorta aneurysm. We present the case of a 21-year-old, fit and asymptomatic male, with unicuspid aortic valve with severe stenosis and ascending aorta dilatation, surgically treated with tricuspidization of the aortic valve with glutaraldehyde-treated autologous pericardium and replacement of the ascending aorta with a straight synthetic graft. Postoperative studies showed a fully functional, neo-tailored tricuspid aortic valve with trivial regurgitation. The patient had an uncomplicated recovery, stayed in the intensive care unit for 2 days and was discharged on the 7th postoperative day.


Asunto(s)
Aneurisma de la Aorta , Enfermedades de las Válvulas Cardíacas , Adulto , Aorta , Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta/cirugía , Válvula Aórtica/cirugía , Humanos , Masculino , Adulto Joven
8.
J Card Surg ; 36(1): 349-352, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33124057

RESUMEN

BACKGROUND: Single-inflow coronary bypass through left internal thoracic artery and Y graft is effective in myocardial revascularization, but left sublavian diseases may affect its safety. AIM OF THE STUDY: To assess that, in presence of a composite Y graft, issues involving the origin of the left internal thoracic artery are relatively easy to manage, even in reoperations. METHODS: A critical stenosis of the subclavian artery involving the origin of a bilateral internal thoracic artery Y graft was bypassed using a free radial artery graft. RESULTS: Bypass was performed between the left thoracic artery and the ascending aorta, off-pump and with excellent results. CONCLUSIONS: In consideration of the excellent long term results of total arterial revascularization, radial artery is a feasible graft option, even in case of a composite Y graft in place.


Asunto(s)
Arterias Mamarias , Angiografía Coronaria , Puente de Arteria Coronaria , Humanos , Revascularización Miocárdica , Arteria Radial , Resultado del Tratamiento
9.
Ann Thorac Surg ; 106(6): 1782-1788, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30179623

RESUMEN

BACKGROUND: This study compared perioperative results and mortality rates of different approaches to perform aortic valve replacement (AVR), describing predictors favoring one approach over the others. METHODS: All patients who underwent AVR were enrolled. The choice of the approach was left to surgeon's preference. Data were retrospectively collected, and the major baseline characteristics (including age, sex, body mass index, creatinine clearance, preoperative condition, cardiovascular risk factors, functional status, and left ventricular ejection fraction, etc.) and intraoperative variables were recorded. To adjust for differences in baseline characteristics between the study groups, a propensity score matching was performed. Linear and logistic regression analyses were performed. RESULTS: Partial upper hemisternotomy was performed in 820 patients (43%), right anterior minithoracotomy in 488 (26%), and median sternotomy in 599 (31%). After propensity score matching, three groups of 377 patients were obtained. Cardiopulmonary bypass and cross-clamp times were shorter in the right anterior minithoracotomy group than in the median sternotomy and partial upper hemisternotomy groups (p < 0.001). No significant differences in in-hospital mortality were observed (p = 0.9). Renal failure (odds ratio, 5.4; 95% confidence interval, 2.3 to 11.4; p < 0.0001), extracardiac arteriopathy (odds ratio, 2.9; 95% confidence interval, 1.1 to 6.7; p = 0.017), and left ventricular ejection fraction (odds ratio, 0.96; 95% confidence interval, 0.93 to 0.99; p = 0.009) emerged as independent predictors of in-hospital mortality. CONCLUSIONS: Minimal-access isolated aortic valve surgery is a reproducible, safe, and effective procedure with similar outcomes and operating times compared with conventional sternotomy.


Asunto(s)
Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Esternotomía/métodos , Toracotomía/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Complicaciones Posoperatorias/mortalidad , Puntaje de Propensión , Estudios Retrospectivos
10.
G Ital Cardiol (Rome) ; 18(10): 734-737, 2017 Oct.
Artículo en Italiano | MEDLINE | ID: mdl-29105688

RESUMEN

Transcatheter valve-in-valve treatment of degenerated supra-annular stentless bioprostheses may be challenging and associated with a high risk of coronary occlusion. Preprocedural imaging evaluation is a key step to assess feasibility and to minimize or prevent coronary occlusion. We report the case of a degenerated Freedom Solo valve, treated with a balloon-expandable valve and a previously deflated stent positioned at the level of both coronary ostia. The procedure was successful but stent inflation at the right coronary ostium was required due to slow flow that occurred after valve implantation.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Anciano , Oclusión Coronaria/prevención & control , Femenino , Humanos , Complicaciones Posoperatorias/prevención & control , Diseño de Prótesis , Falla de Prótesis , Factores de Riesgo
11.
Eur J Cardiothorac Surg ; 52(5): 874-880, 2017 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-28977359

RESUMEN

OBJECTIVES: The most commonly used accesses for transcatheter aortic valve implantation (TAVI) are the transfemoral (TF-TAVI) and the transapical (TA-TAVI) ones. There are concerns about TA-TAVI use in patients with reduced left ventricular ejection fraction (LVEF). The aim of this retrospective multicentre study was to compare the outcomes of TA-TAVI and TF-TAVI in patients with poor LVEF. METHODS: Patients with LVEF ≤35% were included in the analysis. Data were obtained from the Italian Transcatheter Balloon-Expandable Registry (ITER), which enrolled patients undergoing TAVI with the Sapien bioprosthesis in 33 national centres. Patients were divided into 2 groups according to the access: TA or TF. A multivariable logistic regression analysis was performed in order to evaluate whether the type of approach (TA and TF) has an impact on outcomes. RESULTS: Between 2007 and 2012, 1882 patients were enrolled in the Registry. LVEF ≤35% was found in 208 (11.1%) patients. TA-TAVI and TF-TAVI were performed in 69 (33.2%) and 139 (66.8%) patients, respectively. Overall 30-day mortality was 11.6% and 7.9% in TA and TF patients, respectively (P = 0.45). Overall Kaplan-Meier survival was significantly higher in the TF-TAVI group (log rank: P = 0.003). Age [odds ratio (OR) 1.066, P = 0.016], creatinine (OR: 2.301, P < 0.001), preoperative permanent pacemaker (OR: 4.662, P = 0.035) and TA approach (OR: 2.577, P = 0.006) were identified as independent predictors of overall mortality at follow-up. However, the TA approach resulted an independent variable of mortality only 3 years after TAVI. CONCLUSIONS: TAVI yields good results in patients with depressed LVEF. Age, preoperative creatinine and preoperative pacemaker are independently associated with mortality. The TA access is associated with mortality only after 3 years of follow-up, thus probably reflecting a worse general clinical status of these patients.


Asunto(s)
Válvula Aórtica/cirugía , Volumen Sistólico/fisiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/estadística & datos numéricos , Disfunción Ventricular Izquierda/fisiopatología , Ecocardiografía , Humanos , Italia/epidemiología , Estimación de Kaplan-Meier , Sistema de Registros , Estudios Retrospectivos
12.
Eur J Cardiothorac Surg ; 45(2): 384-5, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23868952

RESUMEN

Endovascular aortic replacement (EVAR) techniques have become the first choice option for many aortic diseases in patients in whom standard open surgery was contraindicated or with high surgical risk. A secondary open surgical treatment, following a primary EVAR procedure, could, however, be challenging depending on the type, the extension and the position of primary endoprosthesis. Here, we describe an original and easy technique capable of simplifying a secondary aortic arch replacement following EVAR treatment of the descending thoracic aorta. The basic concept of such techniques is similar to that of the conventional 'elephant trunk' technique and is based on an inverted straight tube graft inserted into the endoprosthesis and anastomized using a multi-layer double suture with external strip felt of Dacron.


Asunto(s)
Aorta Torácica/cirugía , Implantación de Prótesis Vascular/métodos , Prótesis Vascular , Humanos , Reoperación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...