Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
6.
Obes Surg ; 29(6): 1709-1713, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30712169

RESUMEN

BACKGROUND: Minimally invasive surgery may introduce new ergonomic challenges for surgeons. Increased patient body mass index (BMI) may further add to this ergonomic stress. OBJECTIVES: The objective of this study was to quantify the ergonomic impact of patient BMI on surgeons during laparoscopic surgery. SETTING: University Hospital, USA. METHODS: This prospective cohort study analyzed five minimally invasive surgeons during 24 laparoscopic procedures. Each subject's muscle stress was assessed by recording surface electromyography (EMG) data from eight upper body muscle groups during laparoscopic procedures. EMG data was normalized against the maximal voluntary contraction (MVC) of each muscle measured before the start of surgery to create a percentage of the MVC value (%MVC). Subject workload was assessed through the NASA Task Load Index (NTLX). Statistical analysis was used to determine significance between surgeons operating on patients with or without obesity for %MVC and NTLX scores. RESULTS: There was no significant difference (p > 0.05) in both the average muscle activation of all eight muscle groups and NTLX scores during laparoscopic surgery in surgeons operating on patients with BMI > = 30 compared with patients with a BMI < 30. CONCLUSIONS: We detected no differences in ergonomic stress or workload for surgeons operating on patients with or without obesity. For surgeons, the laparoscopic approach may offer an additional advantage over open surgery in patients with obesity. This advantage may be due to an "equalizing effect" of laparoscopy-that surgical ergonomics are less affected by the BMI of the patient when using laparoscopic tools.


Asunto(s)
Índice de Masa Corporal , Ergonomía , Laparoscopía , Músculo Esquelético/fisiopatología , Electromiografía , Humanos , Obesidad , Obesidad Mórbida/cirugía , Estudios Prospectivos , Cirujanos , Carga de Trabajo
7.
Surg Endosc ; 33(6): 1938-1943, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30350099

RESUMEN

INTRODUCTION: Traditional laparoscopic surgery (TLS) has increasingly been associated with physical muscle strain for the operating surgeon. Robot-assisted laparoscopic surgery (RALS) may offer improved ergonomics. Ergonomics for the surgeon on these two platforms can be compared using surface electromyography (sEMG) to measure muscle activation, and the National Aeronautics and Space Administration Task Load Index (NTLX) survey to assess workload subjectively. METHODS: Subjects were recruited and divided into groups according to level of expertise in traditional laparoscopic (TLS) and robot-assisted laparoscopic surgery (RALS): novice, traditional laparoscopic surgeons (TL surgeons), robot-assisted laparoscopic surgeons (RAL surgeons). Each subject performed three fundamentals of laparoscopic surgery (FLS) tasks in randomized order while sEMG data were obtained from bilateral biceps, triceps, deltoid, and trapezius muscles. After completing all tasks, subjects completed the NTLX survey. sEMG data normalized to the maximum voluntary contraction of each muscle (MVC%), and NTLX data were compared with unpaired t tests and considered significant with a p ≤ 0.05. RESULTS: Muscle activation was higher during TLS compared to RALS in most muscle groups for novices except for the trapezius muscles. Muscle activation scores were also higher for TLS among the groups with more experience, but the differences were less significant. NTLX scores were higher for the TLS platform compared to the RALS platform for novices. DISCUSSION: TLS is associated with higher muscle activation in all muscle groups except for trapezius muscles, suggesting greater strain on the surgeon. Increased trapezius muscle activation on RALS has previously been documented and is likely due to the position of the eye piece. The differences seen in muscle activation diminish with increasing levels of expertise. Experience likely mitigates the ergonomic disadvantage of TLS. NTLX survey data suggest there are subjective benefits to RALS, namely in the perception of temporal demand. Further research to correlate NTLX data and sEMG measurements, and to investigate whether these metrics affect patient outcomes is warranted.


Asunto(s)
Competencia Clínica , Ergonomía , Laparoscopía , Contracción Muscular/fisiología , Procedimientos Quirúrgicos Robotizados , Electromiografía , Humanos , Músculo Esquelético/fisiología , Estrés Fisiológico/fisiología , Cirujanos
8.
Surgery ; 165(5): 860-867, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30224084

RESUMEN

The use of Eduard Pernkopf's anatomic atlas presents ethical challenges for modern surgery concerning the use of data resulting from abusive scientific work. In the 1980s and 1990s, historic investigations revealed that Pernkopf was an active National Socialist (Nazi) functionary at the University of Vienna and that among the bodies depicted in the atlas were those of Nazi victims. Since then, discussions persist concerning the ethicality of the continued use of the atlas, because some surgeons still rely on information from this anatomic resource for procedural planning. The ethical implications relevant to the use of this atlas in the care of surgical patients have not been discussed in detail. Based on a recapitulation of the main arguments from the historic controversy surrounding the use of Pernkopf's atlas, this study presents an actual patient case to illustrate some of the ethical considerations relevant to the decision of whether to use the atlas in surgery. This investigation aims to provide a historic and ethical framework for questions concerning the use of the Pernkopf atlas in the management of anatomically complex and difficult surgical cases, with special attention to implications for medical ethics drawn from Jewish law.


Asunto(s)
Anatomía Transversal/ética , Cirugía General/ética , Ilustración Médica/historia , Síndromes de Compresión Nerviosa/cirugía , Neuralgia/cirugía , Adulto , Anatomía Transversal/historia , Disección/ética , Disección/historia , Femenino , Cirugía General/métodos , Historia del Siglo XX , Holocausto , Humanos , Nacionalsocialismo , Síndromes de Compresión Nerviosa/complicaciones , Neuralgia/etiología , Nervios Periféricos/anatomía & histología , Nervios Periféricos/cirugía , Segunda Guerra Mundial
9.
J Surg Res ; 223: 29-33, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29433882

RESUMEN

BACKGROUND: Robotic platforms have the potential advantage of providing additional dexterity and precision to surgeons while performing complex laparoscopic tasks, especially for those in training. Few quantitative evaluations of surgical task performance comparing laparoscopic and robotic platforms among surgeons of varying experience levels have been done. We compared measures of quality and efficiency of Fundamentals of Laparoscopic Surgery task performance on these platforms in novices and experienced laparoscopic and robotic surgeons. METHODS: Fourteen novices, 12 expert laparoscopic surgeons (>100 laparoscopic procedures performed, no robotics experience), and five expert robotic surgeons (>25 robotic procedures performed) performed three Fundamentals of Laparoscopic Surgery tasks on both laparoscopic and robotic platforms: peg transfer (PT), pattern cutting (PC), and intracorporeal suturing. All tasks were repeated three times by each subject on each platform in a randomized order. Mean completion times and mean errors per trial (EPT) were calculated for each task on both platforms. Results were compared using Student's t-test (P < 0.05 considered statistically significant). RESULTS: Among novices, greater errors were noted during laparoscopic PC (Lap 2.21 versus Robot 0.88 EPT, P < 0.001). Among expert laparoscopists, greater errors were noted during laparoscopic PT compared with robotic (PT: Lap 0.14 versus Robot 0.00 EPT, P = 0.04). Among expert robotic surgeons, greater errors were noted during laparoscopic PC compared with robotic (Lap 0.80 versus Robot 0.13 EPT, P = 0.02). Among expert laparoscopists, task performance was slower on the robotic platform compared with laparoscopy. In comparisons of expert laparoscopists performing tasks on the laparoscopic platform and expert robotic surgeons performing tasks on the robotic platform, expert robotic surgeons demonstrated fewer errors during the PC task (P = 0.009). CONCLUSIONS: Robotic assistance provided a reduction in errors at all experience levels for some laparoscopic tasks, but no benefit in the speed of task performance. Robotic assistance may provide some benefit in precision of surgical task performance.


Asunto(s)
Laparoscopía/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Análisis y Desempeño de Tareas , Humanos
10.
Surg Endosc ; 31(8): 3286-3290, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-27924389

RESUMEN

BACKGROUND: There is increasing awareness of potential ergonomic challenges experienced by the laparoscopic surgeon. The purpose of this study is to quantify and compare the ergonomic stress experienced by a surgeon while performing open versus laparoscopic portions of a procedure. We hypothesize that a surgeon will experience greater ergonomic stress when performing laparoscopic surgery. METHODS: We designed a study to measure upper-body muscle activation during the laparoscopic and open portions of sigmoid colectomies in a single surgeon. A sample of five cases was recorded over a two-month time span. Each case contained significant portions of laparoscopic and open surgery. We obtained whole-case electromyography (EMG) tracings from bilateral biceps, triceps, deltoid, and trapezius muscles. After normalization to a maximum voltage of contraction (%MVC), these EMG tracings were used to calculate average muscle activation during the open and laparoscopic segments of each procedure. Paired Student's t test was used to compare the average muscle activation between the two groups (*p < 0.05 considered statistically significant). RESULTS: Significant reductions in mean muscle activation in laparoscopic compared to open procedures were noted for the left triceps (4.07 ± 0.44% open vs. 2.65 ± 0.54% lap, 35% reduction), left deltoid (2.43 ± 0.45% open vs. 1.32 ± 0.16% lap, 46% reduction), left trapezius (9.93 ± 0.1.95% open vs. 4.61 ± 0.67% lap, 54% reduction), right triceps (2.94 ± 0.62% open vs. 1.85 ± 0.28% lap, 37% reduction), and right trapezius (10.20 ± 2.12% open vs. 4.69 ± 1.18% lap, 54% reduction). CONCLUSIONS: Contrary to our hypothesis, the laparoscopic approach provided ergonomic benefit in several upper-body muscle groups compared to the open approach. This may be due to the greater reach of laparoscopic instruments and camera in the lower abdomen/pelvis. Patient body habitus may also have less of an effect in the laparoscopic compared to open approach. Future studies with multiple subjects and different types of procedures are planned to further investigate these findings.


Asunto(s)
Colectomía/métodos , Ergonomía , Laparoscopía , Músculo Esquelético/fisiología , Estrés Fisiológico/fisiología , Adulto , Electromiografía , Femenino , Humanos , Laparoscopía/métodos , Masculino , Enfermedades del Sigmoide/cirugía
11.
J Surg Res ; 206(1): 48-52, 2016 11.
Artículo en Inglés | MEDLINE | ID: mdl-27916374

RESUMEN

BACKGROUND: Robot-assisted laparoscopic surgery (RALS) uses 3-dimensional visualization and wristed instruments that provide more degrees of freedom than rigid traditional laparoscopic (TLS) instrumentation. These features have been touted to improve accuracy and efficiency during surgical task performance. Little is known, however, about the transferability of skills between the two platforms or whether task performance on one platform primes surgeons for task performance on the other. METHODS: Twenty-six subjects naïve to RALS were recruited to perform three Fundamentals of Laparoscopic Surgery tasks on both TLS and RALS platforms: peg transfer, pattern cutting (PC), and intracorporeal suturing. All tasks were performed within Fundamentals of Laparoscopic Surgery testing parameters and repeated three times by each subject on each platform. Platform and task order were randomized. Errors in task performance were defined as drops in the peg transfer task, faults 5 mm or more from the defined pattern during PC, and faults greater than 1 mm in suture placement from the defined points in intracorporeal suturing. Mean completion times and mean errors per trial (EPT) were calculated for each task on both platforms. Results were compared between those who performed TLS first (LF) and those who performed RALS first (RF) using unpaired Student's t-test (P < 0.05 considered statistically significant). RESULTS: No statistically significant differences in task completion time were noted between the LF and RF groups. RF subjects had fewer errors during robotic PC than LF subjects (1.02 EPT versus 1.86 EPT, respectively; P = 0.02). No other differences in task quality were noted. CONCLUSIONS: In surgeon's naïve to RALS, there is no evidence that skills acquired on RALS or TLS platforms are transferable to the other platform or that performing tasks on one platform primes a subject for task performance on the other. Performing TLS PC may have had a negative impact on subsequent RALS PC performance. These findings suggest that distinct programs for skills acquisition are necessary for both the TLS and RALS platforms.


Asunto(s)
Competencia Clínica/estadística & datos numéricos , Laparoscopía/psicología , Curva de Aprendizaje , Procedimientos Quirúrgicos Robotizados/psicología , Humanos , Laparoscopía/instrumentación , Laparoscopía/métodos , Missouri , Proyectos Piloto , Procedimientos Quirúrgicos Robotizados/instrumentación , Procedimientos Quirúrgicos Robotizados/métodos , Análisis y Desempeño de Tareas
12.
J Surg Res ; 203(2): 301-5, 2016 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-27363636

RESUMEN

BACKGROUND: Laparoscopic surgery is associated with a high degree of ergonomic stress. However, the stress associated with surgical assisting is not known. In this study, we compare the ergonomic stress associated with primary and assistant surgical roles during laparoscopic surgery. We hypothesize that higher ergonomic stress will be detected in the primary operating surgeon when compared with the surgical assistant. METHODS: One right-hand dominant attending surgeon performed 698 min of laparoscopic surgery over 13 procedures (222 min primary and 476 min assisting), whereas electromyography data were collected from bilateral biceps, triceps, deltoids, and trapezius muscles. Data were analyzed in 1-min segments. Average muscle activation as quantified by maximal voluntary contraction (%MVC) was calculated for each muscle group during primary surgery and assisting. We compared mean %MVC values with unpaired t-tests. RESULTS: Activation of right (R) biceps and triceps muscle groups is significantly elevated while operating when compared with assisting (R biceps primary: 5.47 ± 0.21 %MVC, assistant: 3.93 ± 0.11, P < 0.001; R triceps primary: 6.53 ± 0.33 %MVC, assistant: 5.48 ± 0.18, P = 0.002). Mean activation of the left trapezius muscle group is elevated during assisting (primary: 4.33 ± 0.26 %MVC, assistant: 5.70 ± 0.40, P = 0.024). No significance difference was noted in the other muscle groups (R deltoid, R trapezius, left [L] biceps, L triceps, and L deltoid). CONCLUSIONS: We used surface electromyography to quantify ergonomic differences between operating and assisting. Surgical assisting was associated with similar and occasionally higher levels of muscle activation compared with primary operating. These findings suggest that surgical assistants face significant ergonomic stress, just as operating surgeons do. Steps must be taken to recognize and mitigate this stress in both operating surgeons and assistants.


Asunto(s)
Ergonomía , Laparoscopía , Contracción Muscular/fisiología , Músculo Esquelético/fisiología , Cirujanos , Electromiografía , Humanos
13.
Ann Thorac Surg ; 100(6): 2325-9, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26652523

RESUMEN

PURPOSE: Expanded polytetrafluoroethylene suture is commonly used for chordal replacement in mitral valve repair, but due to material characteristics, knots can unravel. Our aim was to determine the knot security, including how many throws are necessary to prevent knot failure, with Gore-Tex (W.L. Gore and Associates, Elkton, MD) and the newly available Chord-X (On-X Life Technologies Inc, Austin, TX). DESCRIPTION: Knots were evaluated for maximal load based on: number of throws (6, 8, 10, and 12), tension to secure each throw (10%, 50%, and 85%) and suture type (Gore-Tex CV-5 and Chord-X 3-0). A physiologic force of 2 N was used for comparison. EVALUATION: We evaluated 240 knots. For all knots, the mean load to failure was 11.1 ± 5.8 N. Failure occurred due to unraveling in 141 knots (59%) at 7.1 ± 4.1 N and to breaking in 99 (41%) at 16.7 ± 2.0 N (p < 0.01). Gore-Tex failed at higher loads (12.6 ± 6.0 N vs 9.5 ± 5.2 N, p < 0.01); however, an equivalent number, 6 Gore-Tex and 6 Chord-X, unraveled at 2 N, all with fewer than 10 throws. CONCLUSIONS: Expanded polytetrafluoroethylene has adequate strength to prevent breakage; however, a risk of knot unraveling at physiologic conditions exists when fewer than 10 throws are performed.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Mitral/cirugía , Modelos Biológicos , Politetrafluoroetileno , Complicaciones Posoperatorias/prevención & control , Técnicas de Sutura/instrumentación , Suturas/normas , Falla de Equipo , Humanos , Ensayo de Materiales , Resistencia a la Tracción
16.
Cardiovasc Ther ; 33(2): 50-5, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25759010

RESUMEN

INTRODUCTION: Secondary pulmonary hypertension (PH) and right ventricular dysfunction are common and associated with poor prognosis in HF patients with left ventricular assist devices (LVADs). The role of pulmonary vasodilator therapy for these patients is currently unclear. AIMS: We sought to evaluate the safety and clinical course of patients treated with bosentan, an endothelin receptor antagonist, after the implementation of a LVAD. RESULTS: Between 10/2008 and 5/2011, 50 consecutive patients with mean PAP >25 mmHg were treated with bosentan after LVAD implantation for a mean duration of 15.7 (±12.4) months. Ten patients discontinued the drug for possible side effects, including three for LFT abnormalities. Comparison of baseline to 6-month follow-up data revealed laboratory evidence for decongestion with a decrease in bilirubin (2.3-0.6, P < 0.0001) and an improvement in pulmonary hemodynamics with echocardiographically calculated mean PVR decreasing 1.4 woods units (3.93 ± 1.53 to 2.58 ± 1.05, P < 0.0001). CONCLUSION: In this single-centered retrospective case series, we provide evidence that the tolerability of bosentan in LVAD-supported patients with secondary PH is comparable to prior experience in patients with heart failure.


Asunto(s)
Antihipertensivos/uso terapéutico , Presión Arterial/efectos de los fármacos , Antagonistas de los Receptores de Endotelina/uso terapéutico , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Hipertensión Pulmonar/tratamiento farmacológico , Arteria Pulmonar/efectos de los fármacos , Sulfonamidas/uso terapéutico , Función Ventricular Izquierda , Antihipertensivos/efectos adversos , Bosentán , Antagonistas de los Receptores de Endotelina/efectos adversos , Femenino , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Hipertensión Pulmonar/diagnóstico , Hipertensión Pulmonar/etiología , Hipertensión Pulmonar/fisiopatología , Masculino , Persona de Mediana Edad , Missouri , Diseño de Prótesis , Arteria Pulmonar/fisiopatología , Estudios Retrospectivos , Sulfonamidas/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
18.
J Mech Behav Biomed Mater ; 42: 186-97, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25486631

RESUMEN

BACKGROUND: Over 100 types of soft tissue repair materials are commercially available for hernia repair applications. These materials vary in characteristics such as mesh density, pore size, and pore shape. It is difficult to determine the impact of a single variable of interest due to other compounding variables in a particular design. Thus, the current study utilized prototype meshes designed to evaluate each of these mesh parameters individually. METHODS: Five prototype meshes composed of planar, monofilament polyethylene terephthalate (PET) were evaluated in this study. The meshes were designed to focus on three key parameters, namely mesh density, pore size, and pore shape. The prototype meshes were implanted in the preperitoneal, retrorectus space in a porcine model of ventral incisional hernia repair, and tissue ingrowth characteristics were evaluated after 90 days. Mesh-tissue composite specimens were obtained from each repair site and evaluated via T-peel mechanical testing. Force-displacement data for each T-peel test were analyzed and five characteristics of tissue ingrowth reported: peak force (fp), critical force (fc), fracture energy (Γc), work (W), and work density (Wden). Hematoxylin and eosin (H&E) stained sections of explanted mesh-tissue composites were also assessed for characteristics of tissue response including cellular infiltration, cell types, inflammatory response, extracellular matrix deposition, neovascularization, and fibrosis, with a composite score assigned to represent overall tissue response. RESULTS: The medium-weight, very large pore, hexagonal (MWVLH) mesh performed significantly better than the light-weight, medium pore, diamond (LWMD) mesh for all parameters evaluated (fp, fc, Γc, W, Wden) and trended toward better results than the medium-weight, medium pore, diamond (MWMD) mesh for the majority of the parameters evaluated. When the data for the five meshes was grouped to evaluate mesh density, pore size, and pore shape, differences were more pronounced. No significant differences were observed with respect to mesh density, however significant improvement in mechanical strength of tissue ingrowth occurred as pore size increased from medium to very large. In addition, the hexagonal pores resulted in the strongest tissue ingrowth, followed by the square pores, and finally the diamond pores. Scores for several histological parameters were significantly different for these prototype meshes. For example, the MWVLH mesh showed significantly greater tissue ingrowth by neovascularization histological score than MWMD and MWVLS meshes (p<0.05) and significantly less fibrosis than LWMD and MWVLS meshes (p<0.05). CONCLUSION: Pore shape and pore size significantly altered the mechanical strength of tissue ingrowth and host-site integration in a porcine model of ventral hernia repair, while mesh density had no effect.


Asunto(s)
Hernia Ventral/patología , Hernia Ventral/cirugía , Herniorrafia/instrumentación , Fenómenos Mecánicos , Mallas Quirúrgicas , Porcinos , Animales , Materiales Biocompatibles/farmacología , Ensayo de Materiales , Porosidad , Cicatrización de Heridas/efectos de los fármacos
19.
Bull Am Coll Surg ; 99(11): 40-4, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25509229

RESUMEN

This article addresses a difficult ethical dilemma that transplant surgeons may potentially encounter: whether a patient with a psychiatric illness is a good candidate for a liver transplant. This case study illustrates the challenges involved when considering the ethical principles of patient self-determination, distributive justice of scarce medical resources, "social worth," and protection of vulnerable patient populations. Are patients with psychiatric illness able to provide consent for transplantation? Is it possible to avoid misallocating valuable donor organs and, at the same time, fairly allocate these resources? This article seeks to answer these questions and provide insight into this ethical dilemma.


Asunto(s)
Hepatopatías/complicaciones , Trasplante de Hígado/ética , Trastornos Mentales/complicaciones , Humanos , Hepatopatías/cirugía , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA