Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
JMIR Serious Games ; 9(1): e17017, 2021 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-33538698

RESUMEN

BACKGROUND: Brain plasticity is an important factor in prosthesis usage. This plasticity helps with brain adaptation to learn new movement and coordination patterns needed to control a prosthetic hand. It can be achieved through repetitive muscle training that is usually very exhausting and often results in considerable reduction in patient motivation. Previous studies have shown that a playful concept in rehabilitation can increase patient engagement and perseverance. OBJECTIVE: This study investigated whether the inclusion of video games in the upper limb amputee rehabilitation protocol could have a beneficial impact for muscle preparation, coordination, and patient motivation among individuals who have undergone transradial upper limb amputation. METHODS: Ten participants, including five amputee participants and five able-bodied participants, were enrolled in 10 1-hour sessions within a 4-week rehabilitation program. In order to investigate the effects of the rehabilitation protocol used in this study, virtual reality box and block tests and electromyography (EMG) assessments were performed. Maximum voluntary contraction was measured before, immediately after, and 2 days after interacting with four different EMG-controlled video games. Participant motivation was assessed with the Intrinsic Motivation Inventory (IMI) questionnaire and user evaluation survey. RESULTS: Survey analysis showed that muscle strength and coordination increased at the end of training for all the participants. The results of Pearson correlation analysis indicated that there was a significant positive association between the training period and the box and block test score (r8=0.95, P<.001). The maximum voluntary contraction increment was high before training (6.8%) and in the follow-up session (7.1%), but was very small (2.1%) shortly after the training was conducted. The IMI assessment showed high scores for the subscales of interest, perceived competence, choice, and usefulness, but low scores for pressure and tension. CONCLUSIONS: This study demonstrated that video games enhance motivation and adherence in an upper limb amputee rehabilitation program. The use of video games could be seen as a complementary approach for physical training in upper limb amputee rehabilitation.

2.
Proc Inst Mech Eng H ; 233(2): 181-192, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30518308

RESUMEN

Transtibial prosthetic sockets can be fabricated either by the conventional way, which involve using plaster of Paris bandages for casting. This will include modifications through hand, scanning and digital imaging of software. The aim of this study is to determine the circumferential profiles and conduct a volumetric analysis of a conventional socket that has fabrication using biosculptor technology. In doing this, a male transtibial amputee, age 28 years old with stable health condition was studied, where circumferential measurements were taken at intervals of 1 cm from the distal end of the residual limb to the medial tibial plateau level. Furthermore, the interior volume of both sockets and residuum were determined directly using water displacement method. A comparative value for the calculation of volume was also carried out using engineering mathematical equations. From these measurements, a total surface bearing transtibial sockets was fabricated to compare the changes of circumferential values of both sockets. The finding shows a percentage of the difference between the volume of the residual limb and conventional sockets to be 6.09%, whereas the biosculptor fabrication socket was 7.84% using the water displacement method. A comparison of circumferential profiles and volumetric analysis findings on the contrary showed that socket fabricated using the biosculptor technology is interchangeable with the conventional socket with more advantages, where biosculptor technology produces cheaper sockets and faster process with digital function in the procedure, unlike the conventional manual technique.


Asunto(s)
Diseño de Prótesis/métodos , Tibia , Humanos
3.
J Theor Biol ; 433: 73-84, 2017 11 21.
Artículo en Inglés | MEDLINE | ID: mdl-28844907

RESUMEN

Proper design of stent for application at specific aneurysm effect arteries could help to reduce the issues with thrombosis and aneurysm. In this paper, four types of stent configuration namely half-Y (6 mm), half-Y (4 mm), cross-bar, and full-Y configuration will implanted on real 3D artery bifurcation aneurysm effected arteries. Comparisons were then conducted based on the flow patterns after stent placement using both LBM-based solver and PIV experimental findings. According to the data obtained from all 4 stent designs, the flow profiles and the computed velocity from both methods were in agreement with each other. Both methods found that half-Y (6 mm) stent configuration is by far the best configuration in reducing the blood velocity at the vicinity of the aneurysm sac. The analysis also show that the half-Y (6 mm) stent configuration recorded the highest percentage of velocity reduction and managed to substantially reduce the pressure at the bifurcation region. This high flow velocity reduction through the use of half-Y stent could consequently promote the formation of thrombus thereby reducing the risk of rupture in the aneurysm sac.


Asunto(s)
Aneurisma/terapia , Diseño de Equipo/métodos , Stents/normas , Velocidad del Flujo Sanguíneo , Prótesis Vascular , Simulación por Computador , Humanos , Modelos Cardiovasculares , Reología
4.
Biomed Tech (Berl) ; 62(1): 49-55, 2017 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-27166714

RESUMEN

While considering the importance of the interface between amputees and prosthesis sockets, we study an anthropomorphic prosthesis socket whose size can be dynamically changed according to the requirements of the residual limb. First, we introduce the structure and function of the anthropomorphic prosthesis socket. Second, we study the dynamic model of the prosthesis system and analyze the dynamic characteristics of the prosthesis socket system, the inputs of an oscillometric pump, and the control mechanism of force-sensitive resistor (FSR) pressure signals. Experiments on 10 healthy subjects using the designed system yield an average detection result between 102 and 112 kPa for the FSR pressure sensor and 39 and 41 kPa for the oscillometric pump. Results show the function of the FSR pressure signal in maintaining the contact pressure between the sockets and the residual limb. The potential development of an auto-adjusted socket that uses an oscillometric pump system will provide prosthetic sockets with controllable contact pressure at the residual limb. Moreover, this development is an attractive research area for researchers involved in rehabilitation engineering, prosthetics, and orthotics.


Asunto(s)
Muñones de Amputación/fisiopatología , Oscilometría/métodos , Diseño de Prótesis , Implantación de Prótesis , Humanos , Oscilometría/normas , Presión , Soporte de Peso/fisiología
5.
PLoS One ; 11(4): e0153755, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27104354

RESUMEN

One of the major flow phenomena associated with low Reynolds number flow is the formation of separation bubbles on an airfoil's surface. NACA4415 airfoil is commonly used in wind turbines and UAV applications. The stall characteristics are gradual compared to thin airfoils. The primary criterion set for this work is the capture of laminar separation bubble. Flow is simulated for a Reynolds number of 120,000. The numerical analysis carried out shows the advantages and disadvantages of a few turbulence models. The turbulence models tested were: one equation Spallart Allmars (S-A), two equation SST K-ω, three equation Intermittency (γ) SST, k-kl-ω and finally, the four equation transition γ-Reθ SST. However, the variation in flow physics differs between these turbulence models. Procedure to establish the accuracy of the simulation, in accord with previous experimental results, has been discussed in detail.


Asunto(s)
Modelos Teóricos , Viscosidad
6.
Luminescence ; 31(3): 754-9, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26333749

RESUMEN

UNLABELLED: Influence of Nd(3+) concentration on the optical and thermoluminescence (TL) properties of melt-annealed synthesized 10 Na2O: 20 Li2O: (70-x) B2O3 : xNd2O3, where 0.1≤ x ≤0.7 (LNB) glasses are determined. The absence of sharp peaks in X-ray diffraction patterns confirms the amorphous nature of the prepared glasses. The photoluminescence spectra under 800 nm laser excitations at room temperature exhibit three prominent peaks centred at 538, 603 and 675 nm corresponding to the transitions of (4)G(7/2) → (4)I(9/2), [(4)G(7/2) → (4)I(11/2), (4)G(5/2) → (4)I(9/2)] and [(4)G(7/2) → (4)I(13/2), (4)G(5/2) → (4)I(11/2)], respectively. The TL glow curve exhibits a prominent peak (T(m)) at 180°C. The best performance of the prepared glass was found at 0.5 mol% of Nd2O3. We achieved a good linearity of TL response against dose between 0.5 to 4.0 Gy. The calculated value of the effective atomic number, Z(eff), is 7.55 which is nearly tissue equivalent (Z(eff) = 7.42). These promising features demonstrate the capability of the aforementioned glass to be used as a radiation dosimeter. HIGHLIGHTS: The thermoluminescence and optical properties of new compositions of lithium sodium borate glasses doped with Nd(3+) ions were reported. Attractive features were obtained from the TL, PL and UV-Vis light analysis. Three upconversion luminescences permitting green, orange and red emissions were observed.


Asunto(s)
Boro/química , Vidrio/química , Litio/química , Luminiscencia , Oxígeno/química , Procesos Fotoquímicos , Sodio/química , Temperatura
7.
Luminescence ; 30(8): 1330-5, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25828828

RESUMEN

We report the impact of dysprosium (Dy(3+)) dopant and magnesium oxide (MgO) modifier on the thermoluminescent properties of lithium borate (LB) glass via two procedures. The thermoluminescence (TL) glow curves reveal a single prominent peak at 190 °C for 0.5 mol% of Dy(3+). An increase in MgO contents by 10 mol% enhances the TL intensity by a factor of 1.5 times without causing any shift in the maximum temperature. This enhancement is attributed to the occurrence of extra electron traps created via magnesium and the energy transfer to trivalent Dy(3+) ions. Good linearity in the range of 0.01-4 Gy with a linear correlation coefficient of 0.998, fading as low as 21% over a period of 3 months, excellent reproducibility without oven annealing and tissue equivalent effective atomic numbers ~8.71 are achieved. The trap parameters, including geometric factor (µg), activation energy (E) and frequency factor (s) associated with LMB:Dy are also determined. These favorable TL characteristics of prepared glasses may contribute towards the development of Li2O-MgO-B2O3 radiation dosimeters.


Asunto(s)
Boratos/química , Disprosio/química , Vidrio/química , Litio/química , Compuestos de Magnesio/química
8.
Am J Phys Med Rehabil ; 93(5): 437-44, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24429510

RESUMEN

This report compares wrist supination and pronation and flexion and extension movements with the common body-powered prosthesis and a new biomechatronics prosthesis with regard to patient satisfaction and problems experienced with the prosthesis. Fifteen subjects with traumatic transradial amputation who used both prosthetic systems participated in this study. Each subject completed two questionnaires to evaluate their satisfaction and problems experienced with the two prosthetic systems. Satisfaction and problems with the prosthetic's wrist movements were analyzed in terms of the following: supination and pronation; flexion and extension; appearance; sweating; wounds; pain; irritation; pistoning; smell; sound; durability; and the abilities to open a door, hold a cup, and pick up or place objects. This study revealed that the respondents were more satisfied with the biomechatronics wrist prosthesis with regard to supination and pronation, flexion and extension, pain, and the ability to open a door. However, satisfaction with the prosthesis showed no significant differences in terms of sweating, wounds, irritation, pistoning, smell, sound, and durability. The abilities to hold a cup and pick up or place an object were significantly better with the body-powered prosthesis. The results of the survey suggest that satisfaction and problems with wrist movements in persons with transradial amputation can be improved with a biomechatronics wrist prosthesis compared with the common body-powered prosthesis.


Asunto(s)
Amputación Traumática/rehabilitación , Miembros Artificiales , Diseño de Prótesis , Rango del Movimiento Articular/fisiología , Adulto , Amputados/rehabilitación , Fenómenos Biomecánicos , Estudios de Cohortes , Femenino , Mano , Humanos , Irán , Masculino , Persona de Mediana Edad , Satisfacción del Paciente/estadística & datos numéricos , Ajuste de Prótesis/métodos , Resultado del Tratamiento , Articulación de la Muñeca
9.
Clin Biomech (Bristol, Avon) ; 29(1): 87-97, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24315710

RESUMEN

BACKGROUND: Today a number of prosthetic suspension systems are available for transtibial amputees. Consideration of an appropriate suspension system can ensure that amputee's functional needs are satisfied. The higher the insight to suspension systems, the easier would be the selection for prosthetists. This review attempted to find scientific evidence pertaining to various transtibial suspension systems to provide selection criteria for clinicians. METHODS: Databases of PubMed, Web of Science, and ScienceDirect were explored to find related articles. Search terms were as follows: "Transtibial prosthesis (32), prosthetic suspension (48), lower limb prosthesis (54), below-knee prosthesis (58), prosthetic liner (20), transtibial (193), and prosthetic socket (111)". Two reviewers separately examined the papers. Study design (case series of five or more subjects, retrospective or prospective), research instrument, sampling method, outcome measures and protocols were reviewed. FINDINGS: Based on the selection criteria, 22 articles (15 prospective studies, and 7 surveys) remained. Sweat control was found to be a major concern with the available suspension liners. Donning and doffing procedures for soft liners are also problematic for some users, particularly those with upper limb weakness. Moreover, the total surface bearing (TSB) socket with pin/lock system is favored by the majority of amputees. INTERPRETATION: In summary, no clinical evidence is available to suggest what kind of suspension system could have an influential effect as a "standard" system for all transtibial amputees. However, among various suspension systems for transtibial amputees, the Iceross system was favored by the majority of users in terms of function and comfort.


Asunto(s)
Amputados/rehabilitación , Miembros Artificiales , Pierna , Diseño de Prótesis , Humanos , Masculino , Estudios Prospectivos , Implantación de Prótesis/instrumentación , Estudios Retrospectivos
10.
Disabil Rehabil Assist Technol ; 8(3): 255-60, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-22830946

RESUMEN

PURPOSE: This study examined the kinematic differences between a body-powered prosthesis and a biomechatronics prosthesis as a transradial amputee performed activities that involve flexion/extension and supination/pronation of the wrist. METHOD: The subject's wrist movements were calculated and compared as he completed a wrist range of motion test involving simulated flexion/extension and supination/pronation. RESULTS: The results revealed that, under the test conditions, the body-powered prosthesis limits an individual's ability to complete four different tasks of wrist movement especially when it comes to complete the supination/pronation movement. Conversely, while using biomechatronics wrist prosthesis, the user was able to compensate for limited wrist motion through an ability to achieve a greater range of wrist movement. CONCLUSIONS: The biomechatronics wrist prosthesis provides a greater degree of freedom of wrist flexion/extension and supination/pronation movements.


Asunto(s)
Miembros Artificiales , Diseño de Prótesis , Rango del Movimiento Articular/fisiología , Deformidades Congénitas de las Extremidades Superiores/rehabilitación , Articulación de la Muñeca/fisiopatología , Brazo , Humanos , Masculino , Persona de Mediana Edad
11.
World J Microbiol Biotechnol ; 10(3): 260-3, 1994 May.
Artículo en Inglés | MEDLINE | ID: mdl-24421006

RESUMEN

A strain of protease-producing Bacillus stearothermophilus has been isolated. Glycerol was the best carbon source for production whereas yeast extract was the best nitrogen source. The bacterium could grow up to 70°C but optimum protease production was at 60°C. Best initial pH for protease production was 5. Alkaline pH inhibited production. The enzyme was stable at 60°C for 18 h and was inhibited by EDTA, PMSF and HgCl2.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA