Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Vet Res Commun ; 47(4): 2137-2144, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37452229

RESUMEN

Genetics, the uterine environment, maternal behavior, and rearing conditions can all influence animal behavioral phenotypes. Some studies on cloned pigs have found no differences between the behavioral patterns of cloned and non-cloned animals. Other studies conducted on dogs have reported similarities in the behavior of cloned subjects. This study evaluated the performance of 12 cloned minipigs from three different clone populations (A, B, C) in a detour test around symmetric and asymmetric barriers. We measured the detour time and patterns, in order to investigate the pigs' cognitive abilities.The detour time and the detour entry/exit pattern were recorded. All the animals tended to keep a fixed entry/exit pattern instead of modifying it to accommodate changes in the working set. Significant differences in detour time were found among the populations, with animals belonging to population B being faster than the others, and also within each population.Our study is one of the few to assess the cognitive abilities of cloned minipigs. The results indicate that even animals belonging to the same cloned population may develop different cognitive, hence behavioral characteristics. Whether cloning can be utilized to obtain similar behavioral phenotypes therefore remains a matter of debate.


Asunto(s)
Porcinos Enanos , Humanos , Femenino , Animales , Porcinos , Perros
3.
Pacing Clin Electrophysiol ; 33(7): 795-803, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20132499

RESUMEN

BACKGROUND: Invasively measured left ventricular (LV) dP/dt is the accepted standard for measuring acute and chronic directional changes in LV contractility. Recently, we developed a noninvasive force sensor based on an accelerometer positioned on the chest, which measures the vibrations generated by isovolumic myocardial contraction. The aim of this paper was to compare noninvasive (accelerometer) versus invasive (LV dP/dt) indices of myocardial contractility in a chronic minipig model of pacing-induced heart failure (HF). Comparative assessment was performed both at rest and following dobutamine infusion. METHODS: In adult male minipigs (n = 6), LV contractility was simultaneously assessed both invasively (LV dP/dt, Millar catheter) and noninvasively (accelerometer) at rest and following dobutamine (up to 7.5 mcg/kg/min), both before and after development of HF by pacing the LV at 180 beats/min for 3 weeks. RESULTS: Invasive and noninvasive assessments were obtained in 24 conditions (12 at rest and 12 after dobutamine infusion). Sensor-based cardiac force changes were significantly related to positive peak LV dP/dt(max) changes following dobutamine infusion both in normal (r = 0.88, P < 0.001) and failing heart (r = 0.89, P < 0.001). The force-frequency relation showed a tight correlation between invasive and noninvasive assessment (r = 0.68, P = 0.02). CONCLUSIONS: The force-frequency relation can be assessed noninvasively by a transthoracic sensor based on an accelerometer. The method can efficiently detect the development of resting dysfunction and the contractile reserve at different HF steps, with potential for wearable HF monitoring.


Asunto(s)
Aceleración , Insuficiencia Cardíaca/fisiopatología , Pruebas de Función Cardíaca/instrumentación , Contracción Miocárdica , Transductores , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/fisiopatología , Animales , Diseño de Equipo , Análisis de Falla de Equipo , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/diagnóstico , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Porcinos , Porcinos Enanos , Disfunción Ventricular Izquierda/complicaciones , Vibración
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA