1.
Sci Adv ; 9(41): eadh8263, 2023 10 13.
Artículo en Inglés | MEDLINE | ID: mdl-37831770

RESUMEN

Wildfires are increasing in frequency, raising concerns that smoke can permeate indoor environments and expose people to chemical air contaminants. To study smoke transformations in indoor environments and evaluate mitigation strategies, we added smoke to a test house. Many volatile organic compounds (VOCs) persisted days following the smoke injection, providing a longer-term exposure pathway for humans. Two time scales control smoke VOC partitioning: a faster one (1.0 to 5.2 hours) that describes the time to reach equilibrium between adsorption and desorption processes and a slower one (4.8 to 21.2 hours) that describes the time for indoor ventilation to overtake adsorption-desorption equilibria in controlling the air concentration. These rates imply that vapor pressure controls partitioning behavior and that house ventilation plays a minor role in removing smoke VOCs. However, surface cleaning activities (vacuuming, mopping, and dusting) physically removed surface reservoirs and thus reduced indoor smoke VOC concentrations more effectively than portable air cleaners and more persistently than window opening.


Asunto(s)
Contaminación del Aire Interior , Compuestos Orgánicos Volátiles , Humanos , Compuestos Orgánicos Volátiles/análisis , Humo , Monitoreo del Ambiente
2.
Environ Sci Technol ; 57(43): 16446-16455, 2023 10 31.
Artículo en Inglés | MEDLINE | ID: mdl-37856830

RESUMEN

Energy-efficient residential building standards require the use of mechanical ventilation systems that replace indoor air with outdoor air. Transient outdoor pollution events can be transported indoors via the mechanical ventilation system and other outdoor air entry pathways and impact indoor air chemistry. In the spring of 2022, we observed elevated levels of NOx (NO + NO2) that originated outdoors, entering the National Institute of Standards and Technology (NIST) Net-Zero Energy Residential Test Facility through the mechanical ventilation system. Using measurements of NOx, ozone (O3), and volatile organic compounds (VOCs), we modeled the effect of the outdoor-to-indoor ventilation of NOx pollution on the production of nitrate radical (NO3), a potentially important indoor oxidant. We evaluated how VOC oxidation chemistry was affected by NO3 during NOx pollution events compared to background conditions. We found that nitric oxide (NO) pollution introduced indoors titrated O3 and inhibited the modeled production of NO3. NO ventilated indoors also likely ceased most gas-phase VOC oxidation chemistry during plume events. Only through the artificial introduction of O3 to the ventilation duct during a NOx pollution event (i.e., when O3 and NO2 concentrations were high relative to typical conditions) were we able to measure NO3-initiated VOC oxidation products, indicating that NO3 was impacting VOC oxidation chemistry.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Ozono , Compuestos Orgánicos Volátiles , Óxido Nítrico , Compuestos Orgánicos Volátiles/análisis , Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Dióxido de Nitrógeno/análisis , Ozono/análisis , Monitoreo del Ambiente