1.
Magn Reson Med ; 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38725136

RESUMEN

PURPOSE: To investigate the effect of particle size on liver R 2 * $$ {\mathrm{R}}_2^{\ast } $$ by Monte Carlo simulation and phantom studies at both 1.5 T and 3.0 T. METHODS: Two kinds of particles (i.e., iron sphere and fat droplet) with varying sizes were considered separately in simulation and phantom studies. MRI signals were synthesized and analyzed for predicting R 2 * $$ {\mathrm{R}}_2^{\ast } $$ , based on simulations by incorporating virtual liver model, particle distribution, magnetic field generation, and proton movement into phase accrual. In the phantom study, iron-water and fat-water phantoms were constructed, and each phantom contained 15 separate vials with combinations of five particle concentrations and three particle sizes. R 2 * $$ {\mathrm{R}}_2^{\ast } $$ measurements in the phantom were made at both 1.5 T and 3.0 T. Finally, differences in R 2 * $$ {\mathrm{R}}_2^{\ast } $$ predictions or measurements were evaluated across varying particle sizes. RESULTS: In the simulation study, strong linear and positively correlated relationships were observed between R 2 * $$ {\mathrm{R}}_2^{\ast } $$ predictions and particle concentrations across varying particle sizes and magnetic field strengths ( r ≥ 0.988 $$ r\ge 0.988 $$ ). The relationships were affected by iron sphere size ( p < 0.001 $$ p<0.001 $$ ), where smaller iron sphere size yielded higher predicted R 2 * $$ {\mathrm{R}}_2^{\ast } $$ , whereas fat droplet size had no effect on R 2 * $$ {\mathrm{R}}_2^{\ast } $$ predictions ( p ≥ 0.617 $$ p\ge 0.617 $$ ) for constant total fat concentration. Similarly, the phantom study showed that R 2 * $$ {\mathrm{R}}_2^{\ast } $$ measurements were relatively sensitive to iron sphere size ( p ≤ 0.004 $$ p\le 0.004 $$ ) unlike fat droplet size ( p ≥ 0.223 $$ p\ge 0.223 $$ ). CONCLUSION: Liver R 2 * $$ {\mathrm{R}}_2^{\ast } $$ is affected by iron sphere size, but is relatively unaffected by fat droplet size. These findings may lead to an improved understanding of the underlying mechanisms of R 2 * $$ {\mathrm{R}}_2^{\ast } $$ relaxometry in vivo, and enable improved quantitative MRI phantom design.

2.
J Magn Reson Imaging ; 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38662618

RESUMEN

BACKGROUND: Recent multicenter, multivendor MRI-based R2* vs. liver iron concentration (LIC) calibrations (i.e., MCMV calibrations) may facilitate broad clinical dissemination of R2*-based LIC quantification. However, these calibrations are based on a centralized offline R2* reconstruction, and their applicability with vendor-provided R2* maps is unclear. PURPOSE: To determine R2* ranges of agreement between the centralized and three MRI vendors' R2* reconstructions. STUDY TYPE: Prospective. SUBJECTS: Two hundred and seven subjects (mean age 37.6 ± 19.6 years; 117 male) with known or suspected iron overload from four academic medical centers. FIELD STRENGTH/SEQUENCE: Standardized multiecho spoiled gradient echo sequence at 1.5 T and 3.0 T for R2* mapping and a multiple spin-echo sequence at 1.5 T for LIC quantification. MRI vendors: GE Healthcare, Philips Healthcare, and Siemens Healthineers. ASSESSMENT: R2* maps were generated using both the centralized and vendor reconstructions, and ranges of agreement were determined. R2*-LIC linear calibrations were determined for each site, field strength, and reconstruction and compared with the MCMV calibrations. STATISTICAL TESTS: Bland-Altman analysis to determine ranges of agreement. Linear regression, analysis of covariance F tests, and Tukey's multiple comparison testing to assess reproducibility of calibrations across sites and vendors. A P value <0.05 was considered significant. RESULTS: The upper limits of R2* ranges of agreement were approximately 500, 375, and 330 s-1 for GE, Philips, and Siemens reconstructions, respectively, at 1.5 T and approximately 700 and 800 s-1 for GE and Philips, respectively, at 3.0 T. Within the R2* ranges of agreement, vendor R2*-LIC calibrations demonstrated high reproducibility (no significant differences between slopes or intercepts; P ≥ 0.06) and agreed with the MCMV calibrations (overlapping 95% confidence intervals). DATA CONCLUSION: Based on the determined upper limits, R2* measurements obtained from vendor-provided R2* maps may be reliably and practically used to quantify LIC less than approximately 8-13 mg/g using the MCMV calibrations and similar acquisition parameters as this study. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 3.

4.
Magn Reson Med ; 91(5): 2172-2187, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38174431

RESUMEN

PURPOSE: The objective was to develop a fully automated algorithm that generates confidence maps to identify regions valid for analysis of quantitative proton density fat fraction (PDFF) and R 2 * $$ {R}_2^{\ast } $$ maps of the liver, generated with chemical shift-encoded MRI (CSE-MRI). Confidence maps are urgently needed for automated quality assurance, particularly with the emergence of automated segmentation and analysis algorithms. METHODS: Confidence maps for both PDFF and R 2 * $$ {R}_2^{\ast } $$ maps are generated based on goodness of fit, measured by normalized RMS error between measured complex signals and the CSE-MRI signal model. Based on Cramér-Rao lower bound and Monte-Carlo simulations, normalized RMS error threshold criteria were developed to identify unreliable regions in quantitative maps. Simulation, phantom, and in vivo clinical studies were included. To analyze the clinical data, a board-certified radiologist delineated regions of interest (ROIs) in each of the nine liver segments for PDFF and R 2 * $$ {R}_2^{\ast } $$ analysis in consecutive clinical CSE-MRI data sets. The percent area of ROIs in areas deemed unreliable by confidence maps was calculated to assess the impact of confidence maps on real-world clinical PDFF and R 2 * $$ {R}_2^{\ast } $$ measurements. RESULTS: Simulations and phantom studies demonstrated that the proposed algorithm successfully excluded regions with unreliable PDFF and R 2 * $$ {R}_2^{\ast } $$ measurements. ROI analysis by the radiologist revealed that 2.6% and 15% of the ROIs were placed in unreliable areas of PDFF and R 2 * $$ {R}_2^{\ast } $$ maps, as identified by confidence maps. CONCLUSION: A proposed confidence map algorithm that identifies reliable areas of PDFF and R 2 * $$ {R}_2^{\ast } $$ measurements from CSE-MRI acquisitions was successfully developed. It demonstrated technical and clinical feasibility.


Asunto(s)
Hígado , Protones , Reproducibilidad de los Resultados , Hígado/diagnóstico por imagen , Fantasmas de Imagen , Imagen por Resonancia Magnética
5.
J Comput Assist Tomogr ; 48(1): 12-18, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37551163

RESUMEN

PURPOSE: The aim of this study was to formally investigate the apparent variation in lesion size of hepatic metastatic lesions from colorectal cancer on hepatobiliary phase (HBP) and dual contrast images of magnetic resonance imaging performed with both hepatobiliary and extracellular contrast agents. METHODS: Patients with known colorectal carcinoma who had undergone dual contrast liver magnetic resonance imaging were identified in our institutional database. Metastatic lesions were measured semiautomatically on both HBP and dual contrast images with a custom software tool that automatically identifies the lesion edge and thereby the lesion diameter. Lesion measurements from both sets of images were compared with a Student t test and Bland-Altman analysis. Lesions were also measured on both HBP and dual contrast images by 2 fellowship-trained abdominal radiologists. Measurements from the software and radiologists were compared with a Student t test and Bland-Altman analysis; interreader agreement was evaluated with the intraclass correlation coefficient. RESULTS: A total of 70 liver lesions in 39 patients was identified. Software-based measurements were significantly larger on HBP than dual contrast images ( P < 0.001), with a mean lesion size of 10.9 ± 4.2 mm for HBP and 10.5 ± 4.2 mm for dual contrast measurements. Radiologist-based measurements showed a similar trend, with HBP measurements being significantly larger than dual contrast measurements ( P < 0.001). Bland-Altman analysis indicated a mean bias ± 2 SD of +0.4 ± 1.6 mm for software-based measurements and +0.9 ± 2.9 mm and +0.7 ± 2.1 mm for readers 1 and 2, respectively. The intraclass correlation coefficient for interreader agreement was 0.9. CONCLUSIONS: Both software-based and radiologist-based measurements of colorectal cancer liver metastases are significantly larger on HBP than dual contrast images. Based on these findings, we recommend that longitudinal assessment be performed consistently on either HBP or dual contrast phases to avoid introduction of avoidable variability.


Asunto(s)
Neoplasias Colorrectales , Neoplasias Hepáticas , Humanos , Medios de Contraste , Sensibilidad y Especificidad , Estudios Retrospectivos , Hígado/diagnóstico por imagen , Hígado/patología , Neoplasias Hepáticas/patología , Imagen por Resonancia Magnética/métodos , Neoplasias Colorrectales/diagnóstico por imagen , Neoplasias Colorrectales/patología , Gadolinio DTPA
6.
AJR Am J Roentgenol ; 2023 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-37850581

RESUMEN

Since its introduction 35 years ago, gadolinium-enhanced MRI has fundamentally changed medical practice. While extraordinarily safe, gadolinium-based contrast agents (GBCAs) may have side effects. Four distinct safety considerations include: acute allergic-like reactions, nephrogenic systemic fibrosis (NSF), gadolinium deposition, and symptoms associated with gadolinium exposure. Acute reactions after GBCA administration are uncommon-far less than with iodinated contrast agents-and, while rare, serious reactions can occur. NSF is a rare, but serious, scleroderma-like condition occurring in patients with kidney failure after exposure to American College of Radiology (ACR) Group 1 GBCAs. Group 2 and 3 GBCAs are considered lower risk, and, through their use, NSF has largely been eliminated. Unrelated to NSF, retention of trace amounts of gadolinium in the brain and other organs has been recognized for over a decade. Deposition occurs with all agents, although linear agents appear to deposit more than macrocyclic agents. Importantly, to date, no data demonstrate any adverse biologic or clinical effects from gadolinium deposition, even with normal kidney function. This article summarizes the latest safety evidence of commercially available GBCAs with a focus on new agents, discusses updates to the ACR NSF GBCA safety classification, and describes approaches for strengthening the evidence needed for regulatory decisions.

9.
AJR Am J Roentgenol ; 221(6): 736-746, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37341181

RESUMEN

BACKGROUND. Closure of a GE Healthcare facility in Shanghai, China, in 2022 disrupted the iodinated contrast media supply. Technologic advances have addressed limitations associated with the use of pulmonary MRA for diagnosis of pulmonary embolism (PE). OBJECTIVE. The purpose of this study was to describe a single institution's experience in the use of pulmonary MRA as an alternative to CTA for the diagnosis of PE in the general population during the iodinated contrast media shortage in 2022. METHODS. This retrospective single-center study included all CTA and MRA examinations performed to exclude PE from April 1 through July 31 (18 weekly periods) in 2019 (before the COVID-19 pandemic and contrast media shortage), 2021 (during the pandemic but before the shortage), and 2022 (during both the pandemic and the shortage). From early May through mid-July of 2022, MRA served as the preferred test for PE diagnosis, to preserve iodinated contrast media. CTA and MRA reports were reviewed. The total savings in iodinated contrast media volume resulting from preferred use of MRA was estimated. RESULTS. The study included 4491 examinations of 4006 patients (mean age, 57 ± 18 [SD] years; 1715 men, 2291 women): 1245 examinations (1111 CTA, 134 MRA) in 2019, 1547 examinations (1403 CTA, 144 MRA) in 2021, and 1699 examinations (1282 CTA, 417 MRA) in 2022. In 2022, the number of MRA examinations was four (nine when normalized to a 7-day period) in week 1, and this number increased to a maximum of 63 in week 10 and then decreased to 10 in week 18. During weeks 8-11, more MRA examinations (range, 45-63 examinations) than CTA examinations (range, 27-46 examinations) were performed. In 2022, seven patients with negative MRA underwent subsequent CTA within 2 weeks; CTA was negative in all cases. In 2022, 13.9% of CTA examinations (vs 10.3% of MRA examinations) were reported as having limited image quality. The estimated 4-month savings resulting from preferred use of MRA in 2022, under the assumption of uniform simple linear growth in CTA utilization annually and a CTA dose of 1 mL/kg, was 27 L of iohexol (350 mg I/mL). CONCLUSION. Preferred use of pulmonary MRA for PE diagnosis in the general population helped to conserve iodinated contrast media during the 2022 shortage. CLINICAL IMPACT. This single-center experience shows pulmonary MRA to be a practical substitute for pulmonary CTA in emergency settings.


Asunto(s)
Medios de Contraste , Embolia Pulmonar , Masculino , Humanos , Femenino , Adulto , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Pandemias , Angiografía por Resonancia Magnética/métodos , China , Embolia Pulmonar/diagnóstico por imagen
10.
Radiographics ; 43(6): e220181, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37227944

RESUMEN

Quantitative imaging biomarkers of liver disease measured by using MRI and US are emerging as important clinical tools in the management of patients with chronic liver disease (CLD). Because of their high accuracy and noninvasive nature, in many cases, these techniques have replaced liver biopsy for the diagnosis, quantitative staging, and treatment monitoring of patients with CLD. The most commonly evaluated imaging biomarkers are surrogates for liver fibrosis, fat, and iron. MR elastography is now routinely performed to evaluate for liver fibrosis and typically combined with MRI-based liver fat and iron quantification to exclude or grade hepatic steatosis and iron overload, respectively. US elastography is also widely performed to evaluate for liver fibrosis and has the advantage of lower equipment cost and greater availability compared with those of MRI. Emerging US fat quantification methods can be performed along with US elastography. The author group, consisting of members of the Society of Abdominal Radiology (SAR) Liver Fibrosis Disease-Focused Panel (DFP), the SAR Hepatic Iron Overload DFP, and the European Society of Radiology, review the basics of liver fibrosis, fat, and iron quantification with MRI and liver fibrosis and fat quantification with US. The authors cover technical requirements, typical case display, quality control and proper measurement technique and case interpretation guidelines, pitfalls, and confounding factors. The authors aim to provide a practical guide for radiologists interpreting these examinations. © RSNA, 2023 See the invited commentary by Ronot in this issue. Quiz questions for this article are available in the supplemental material.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Sobrecarga de Hierro , Hepatopatías , Humanos , Hierro , Cirrosis Hepática/diagnóstico por imagen , Cirrosis Hepática/patología , Hígado/diagnóstico por imagen , Hígado/patología , Imagen por Resonancia Magnética/métodos , Hepatopatías/patología , Sobrecarga de Hierro/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/métodos , Radiólogos , Biomarcadores
12.
Magn Reson Med ; 90(2): 444-457, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37036023

RESUMEN

PURPOSE: This study addresses the challenges in obtaining abdominal 4D flow MRI of obese patients. We aimed to evaluate spectral saturation and inner volume excitation as methods to mitigating artifacts originating from adipose signals, with the goal of enhancing image quality and improving quantification. METHODS: Radial 4D flow MRI acquisitions with fat mitigation (inner volume excitation [IVE] and intermittent fat saturation [FS]) were compared to a standard slab selective excitation (SSE) in a test-retest study of 15 obese participants. IVE selectively excited a cylindrical region of interest, avoiding contamination from peripheral adipose tissue, while FS globally suppressed fat based on spectral selection. Acquisitions were evaluated qualitatively based on expert ratings and quantitatively based on conservation of mass, test-retest repeatability, and a divergence free quality metric. Errors were evaluated statistically using the absolute and relative errors, regression, and Bland-Altman analysis. RESULTS: IVE demonstrated superior performance quantitatively in the conservation of mass analysis in the portal vein, with higher correlation and lower bias in regression analysis. IVE also produced flow fields with the lowest divergence error and was rated best in overall image quality, delineating small vessels, and producing the least streaking artifacts. Evaluation results did not differ significantly between FS and SSE. Test-retest reproducibility was similarly high for all sequences, with data suggesting biological variations dominate the technical variability. CONCLUSION: IVE improved hemodynamic assessment of radial 4D flow MRI in the abdomen of obese participants while FS did not lead to significant improvements in image quality or flow metrics.


Asunto(s)
Imagenología Tridimensional , Imagen por Resonancia Magnética , Humanos , Reproducibilidad de los Resultados , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Tejido Adiposo/diagnóstico por imagen , Obesidad/diagnóstico por imagen
13.
Abdom Radiol (NY) ; 48(6): 2049-2059, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37016247

RESUMEN

PURPOSE: The purpose of this work was to establish normal reference values for 4D flow MRI-derived flow, velocity, and vessel diameters, and to define characteristic flow patterns in the portal venous system of healthy adult subjects. METHODS: For this retrospective study, we screened all available 4D flow MRI exams of the upper abdomen in healthy adults acquired at our institution between 2012 and 2022 at either 1.5 T or 3.0 T MRI after ≥ 5 h fasting. Flow, velocity, and effective diameter were quantified in the 8 planes in the portal venous system (splenic vein, superior mesenteric vein, main, right, and left portal veins). Vessel delineation was manually adjusted over time. Reference ranges for were defined as the mean ± 2 standard deviations. Three readers noted helical and vortical flow on time-resolved pathline visualizations. Conservation of mass flow analysis was performed for quality assurance. RESULTS: We included 44 healthy subjects (26 female, 18-74 years) in the analysis. We report reference values for mean and peak flow, mean velocity, and vessel diameter in the healthy portal vein using 4D flow MRI. Normal flow patterns in the portal vein included faint helical (66%) or linear flow (34%). Conservation of mass analysis demonstrated a relative error of 1.1 ± 4.6% standard deviation (SD) at the splenomesenteric confluence and - 1.4 ± 4.1% SD at the portal bifurcation. CONCLUSION: We have reported normal hemodynamic values that are necessary baseline data for emerging clinical applications of 4D flow MRI in the portal venous system. Results are consistent with previously published values from smaller cohorts.


Asunto(s)
Abdomen , Imagen por Resonancia Magnética , Adulto , Humanos , Femenino , Valores de Referencia , Estudios Retrospectivos , Velocidad del Flujo Sanguíneo , Imagen por Resonancia Magnética/métodos , Vena Porta/diagnóstico por imagen , Imagenología Tridimensional/métodos
14.
Comput Methods Programs Biomed ; 233: 107494, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36965302

RESUMEN

BACKGROUND AND OBJECTIVE: To model hepatic steatosis in adult humans with non-alcoholic fatty liver disease based on stereology and spatial distribution of fat droplets from liver biopsy specimens. METHODS: Histological analysis was performed on 30 adult human liver biopsy specimens with varying degrees of steatosis. Morphological features of fat droplets were characterized by gamma distribution function (GDF) in both two-dimensional (2D) and three-dimensional (3D) spaces from three aspects: 1) size distribution indicating non-uniformity of fat droplets in radius; 2) nearest neighbor distance distribution indicating heterogeneous accumulation (i.e., clustering) of fat droplets; 3) regional anisotropy indicating inter-regional variability in fat fraction (FF). To generalize the morphological description of hepatic steatosis to different FFs, correlation analysis was performed among the estimated GDF parameters and FFs for all specimens. Finally, Monte Carlo modeling of hepatic steatosis was developed to simulate fat droplet distribution in tissue. RESULTS: Morphological features, including size and nearest neighbor distance in 2D and 3D spaces as well as regional anisotropy, statistically captured the distribution of fat droplets by the GDF fit (R2 > 0.54). The estimated GDF parameters (i.e., scale and shape parameters) and FFs were well correlated, with R2 > 0.55. In addition, simulated 3D liver morphological models demonstrated similar sections to real histological samples both visually and quantitatively. CONCLUSIONS: The morphology of hepatic steatosis is well characterized by stereology and spatial distribution of fat droplets. Simulated models demonstrate similar appearances to real histological samples. Furthermore, the model may help understand MRI signal behavior in the presence of liver steatosis.


Asunto(s)
Hígado , Enfermedad del Hígado Graso no Alcohólico , Adulto , Humanos , Hígado/diagnóstico por imagen , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Enfermedad del Hígado Graso no Alcohólico/patología , Imagen por Resonancia Magnética/métodos , Método de Montecarlo , Índice de Severidad de la Enfermedad
15.
Magn Reson Med ; 90(2): 385-399, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36929781

RESUMEN

PURPOSE: To improve repeatability and reproducibility across acquisition parameters and reduce bias in quantitative susceptibility mapping (QSM) of the liver, through development of an optimized regularized reconstruction algorithm for abdominal QSM. METHODS: An optimized approach to estimation of magnetic susceptibility distribution is formulated as a constrained reconstruction problem that incorporates estimates of the input data reliability and anatomical priors available from chemical shift-encoded imaging. The proposed data-adaptive method was evaluated with respect to bias, repeatability, and reproducibility in a patient population with a wide range of liver iron concentration (LIC). The proposed method was compared to the previously proposed and validated approach in liver QSM for two multi-echo spoiled gradient-recalled echo protocols with different acquisition parameters at 3T. Linear regression was used for evaluation of QSM methods against a reference FDA-approved R 2 $$ {R}_2 $$ -based LIC measure and R 2 ∗ $$ {R}_2^{\ast } $$ measurements; repeatability/reproducibility were assessed by Bland-Altman analysis. RESULTS: The data-adaptive method produced susceptibility maps with higher subjective quality due to reduced shading artifacts. For both acquisition protocols, higher linear correlation with both R 2 $$ {R}_2 $$ - and R 2 ∗ $$ {R}_2^{\ast } $$ -based measurements were observed for the data-adaptive method ( r 2 = 0 . 74 / 0 . 69 $$ {r}^2=0.74/0.69 $$ for R 2 $$ {R}_2 $$ , 0 . 97 / 0 . 95 $$ 0.97/0.95 $$ for R 2 ∗ $$ {R}_2^{\ast } $$ ) than the standard method ( r 2 = 0 . 60 / 0 . 66 $$ {r}^2=0.60/0.66 $$ and 0 . 79 / 0 . 88 $$ 0.79/0.88 $$ ). For both protocols, the data-adaptive method enabled better test-retest repeatability (repeatability coefficients 0.19/0.30 ppm for the data-adaptive method, 0.38/0.47 ppm for the standard method) and reproducibility across protocols (reproducibility coefficient 0.28 vs. 0.53ppm) than the standard method. CONCLUSIONS: The proposed data-adaptive QSM algorithm may enable quantification of LIC with improved repeatability/reproducibility across different acquisition parameters as 3T.


Asunto(s)
Hierro , Imagen por Resonancia Magnética , Humanos , Reproducibilidad de los Resultados , Hierro/análisis , Imagen por Resonancia Magnética/métodos , Hígado/diagnóstico por imagen , Hígado/química , Abdomen , Encéfalo/diagnóstico por imagen , Mapeo Encefálico
16.
J Cardiovasc Magn Reson ; 25(1): 9, 2023 02 13.
Artículo en Inglés | MEDLINE | ID: mdl-36775827

RESUMEN

BACKGROUND: Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) is feasible for portal blood flow evaluation after placement of transjugular intrahepatic portosystemic shunts (TIPS) in patients with liver cirrhosis. However, clinical acceptance of 4D flow CMR in TIPS patients is limited due to the lack of validation studies. The purpose of this study was to validate 4D flow CMR-derived measurements in TIPS stent grafts using a three-dimensional (3D)-printed flow phantom. METHODS: A translucent flow phantom of the portal vasculature was 3D-printed. The phantom consisted of the superior mesenteric vein and the splenic vein draining into the portal vein, the TIPS-tract, and the hepatic vein. A TIPS stent graft (Gore® Viatorr®) was positioned within the TIPS-tract. Superior mesenteric vein and splenic vein served as inlets for blood-mimicking fluid. 4D flow CMR acquisitions were performed at 3T at preset flow rates of 0.8 to 2.8 l/min using velocity encoding of both 1.0 and 2.0 m/s. Flow rates and velocities were measured at predefined levels in the portal vasculature and within the stent graft. Accuracy of 4D flow CMR was assessed through linear regression with reference measurements obtained by flow sensors and two-dimensional (2D) phase contrast (PC) CMR. Intra- and interobserver agreement were assessed through Bland-Altman analyses. RESULTS: At a velocity encoding of 2.0 m/s, 4D flow CMR-derived flow rates and velocities showed an excellent correlation with preset flow rates and 2D PC CMR-derived flow velocities at all vascular levels and within the stent graft (all r ≥ 0.958, p ≤ 0.003). At a velocity encoding of 1.0 m/s, aliasing artifacts were present within the stent graft at flow rates ≥ 2.0 l/min. 4D flow CMR-derived measurements revealed high intra- and interobserver agreement. CONCLUSIONS: The in vitro accuracy and precision of 4D flow CMR is unaffected by the presence of TIPS stent grafts, suggesting that 4D flow CMR may be used to monitor TIPS patency in patients with liver cirrhosis.


Asunto(s)
Cirrosis Hepática , Stents , Humanos , Valor Predictivo de las Pruebas , Espectroscopía de Resonancia Magnética , Impresión Tridimensional
17.
Radiology ; 307(1): e221856, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36809220

RESUMEN

Accumulation of excess iron in the body, or systemic iron overload, results from a variety of causes. The concentration of iron in the liver is linearly related to the total body iron stores and, for this reason, quantification of liver iron concentration (LIC) is widely regarded as the best surrogate to assess total body iron. Historically assessed using biopsy, there is a clear need for noninvasive quantitative imaging biomarkers of LIC. MRI is highly sensitive to the presence of tissue iron and has been increasingly adopted as a noninvasive alternative to biopsy for detection, severity grading, and treatment monitoring in patients with known or suspected iron overload. Multiple MRI strategies have been developed in the past 2 decades, based on both gradient-echo and spin-echo imaging, including signal intensity ratio and relaxometry strategies. However, there is a general lack of consensus regarding the appropriate use of these methods. The overall goal of this article is to summarize the current state of the art in the clinical use of MRI to quantify liver iron content and to assess the overall level of evidence of these various methods. Based on this summary, expert consensus panel recommendations on best practices for MRI-based quantification of liver iron are provided.


Asunto(s)
Sobrecarga de Hierro , Hígado , Humanos , Hígado/diagnóstico por imagen , Hígado/patología , Sobrecarga de Hierro/diagnóstico por imagen , Sobrecarga de Hierro/patología , Imagen por Resonancia Magnética/métodos , Hierro , Biopsia
18.
Placenta ; 134: 1-8, 2023 03 24.
Artículo en Inglés | MEDLINE | ID: mdl-36807998

RESUMEN

INTRODUCTION: The goal of this pilot study is to determine if ferumoxytol-enhanced MR might provide a new approach to the diagnosis of placenta accreta spectrum (PAS), and if so, to identify signs of PAS. METHODS: Ten pregnant women were referred for MRI evaluation for PAS. MR studies consisted of pre-contrast SSFSE, SSFP, DWI, and ferumoxytol-enhanced sequences. Post-contrast images were rendered as MIP and MinIP images to separately display the maternal and fetal circulations respectively. Two readers examined the images for architectural changes to placentone (fetal cotyledon) that might distinguish PAS cases from normal. Attention was given to the size and morphology of the placentone, villous tree, and vascularity. In addition, the images were examined for evidence of fibrin/fibrinoid, intervillous thrombus, basal and chorionic plate bulges. Interobserver agreement was characterized with kappa coefficients and levels of confidence for feature identification was recorded on a 10-point scale. RESULTS: At delivery, there were five normal placentas and five with PAS (one accreta, two increta, two percreta). The ten changes of placental architecture in PAS included: focal/regional expansion of placentone(s); lateral displacement and compression of the villous tree; disruption of a regular pattern of normal placentones; bulging of the basal plate; bulging of the chorionic plate; transplacental stem villi; linear/nodular bands at basal plate; non-tapering villous branches; intervillous hemorrhage; and dilated subplacental vessels. All these changes were more common in PAS; the first five achieved statistical significance in this small sample. The interobserver agreement and confidence for the identification of these features was good to excellent except for dilated subplacental vessels. DISCUSSION: Ferumoxytol-enhanced MR imaging appears to depict derangements of the internal architecture of placentas with PAS, thereby suggesting a promising new strategy to diagnose PAS.


Asunto(s)
Placenta Accreta , Placenta Previa , Embarazo , Femenino , Humanos , Placenta Accreta/diagnóstico , Placenta , Óxido Ferrosoférrico , Proyectos Piloto , Placenta Previa/diagnóstico , Imagen por Resonancia Magnética/métodos , Estudios Retrospectivos
19.
Magn Reson Med ; 89(6): 2186-2203, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36656152

RESUMEN

PURPOSE: Quantitative volumetric T1 mapping in the liver has the potential to aid in the detection, diagnosis, and quantification of liver fibrosis, inflammation, and spatially resolved liver function. However, accurate measurement of hepatic T1 is confounded by the presence of fat and inhomogeneous B 1 + $$ {B}_1^{+} $$ excitation. Furthermore, scan time constraints related to respiratory motion require tradeoffs of reduced volumetric coverage and/or increased acquisition time. This work presents a novel 3D acquisition and estimation method for confounder-corrected T1 measurement over the entire liver within a single breath-hold through simultaneous estimation of T1 , fat and B 1 + $$ {B}_1^{+} $$ . THEORY AND METHODS: The proposed method combines chemical shift encoded MRI and variable flip angle MRI with a B 1 + $$ {B}_1^{+} $$ mapping technique to enable confounder-corrected T1 mapping. The method was evaluated theoretically and demonstrated in both phantom and in vivo acquisitions at 1.5 and 3.0T. At 1.5T, the method was evaluated both pre- and post- contrast enhancement in healthy volunteers. RESULTS: The proposed method demonstrated excellent linear agreement with reference inversion-recovery spin-echo based T1 in phantom acquisitions at both 1.5 and 3.0T, with minimal bias (5.2 and 45 ms, respectively) over T1 ranging from 200-1200 ms. In vivo results were in general agreement with reference saturation-recovery based 2D T1 maps (SMART1 Map, GE Healthcare). CONCLUSION: The proposed 3D T1 mapping method accounts for fat and B 1 + $$ {B}_1^{+} $$ confounders through simultaneous estimation of T1 , B 1 + $$ {B}_1^{+} $$ , PDFF and R 2 * $$ {R}_2^{\ast } $$ . It demonstrates strong linear agreement with reference T1 measurements, with low bias and high precision, and can achieve full liver coverage in a single breath-hold.


Asunto(s)
Hígado , Enfermedad del Hígado Graso no Alcohólico , Humanos , Hígado/diagnóstico por imagen , Hígado/patología , Contencion de la Respiración , Imagen por Resonancia Magnética/métodos , Enfermedad del Hígado Graso no Alcohólico/patología , Cirrosis Hepática , Reproducibilidad de los Resultados , Fantasmas de Imagen