1.
Dtsch Med Wochenschr ; 130(12): 717-20, 2005 Mar 24.
Artículo en Alemán | MEDLINE | ID: mdl-15776357

RESUMEN

Age-related physiologic changes, a higher prevalence of chronic illness, and concomitant (often multiple) medication account for a higher susceptibility of elderly patients to syncope. Although elderly patients are the largest group with syncope, the causes frequently remain unclear. Multifactorial causes, lack of witnesses, overlap with falls, and additional cognitive impairment often confound the assessment of syncope in the elderly. Thus, strategic investigation is often needed to establish the diagnosis and to unmask the cause. In addition to a comprehensive medical history (by both patient and witnesses), a thorough physical examination including supine and standing blood pressure measurements and a standard 12 lead ECG remain the mainstay of diagnosis. The decision whether additional tests are needed depends on indications whether organic heart disease is present or not. Without evidence of structural heart disease, tilt table testing and studies of autonomic function are the next steps. In contrast, additional cardiac investigation (including invasive studies) is needed in patients with suspected or documented cardiac disease. External or implantable loop recorders represent a significant improvement in the diagnosis of rare episodes of (brady- or tachy)-arrhythmias. Prognosis is determined by the underlying (heart) disease.


Asunto(s)
Cardiopatías/complicaciones , Síncope/etiología , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/complicaciones , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Causas de Muerte , Muerte Súbita Cardíaca/prevención & control , Electrocardiografía Ambulatoria/instrumentación , Electrodos Implantados , Cardiopatías/diagnóstico , Cardiopatías/mortalidad , Humanos , Factores de Riesgo , Síncope/mortalidad
2.
Z Kardiol ; 93(4): 278-86, 2004 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-15085372

RESUMEN

The study describes the electrophysiological effects of transvenous cardiac nerve stimulation in an animal model of myocardial infarction. In ten sheep with recent myocardial infarction, transvenous stimulation of parasympathetic cardiac nerves was achieved from a catheter in the right pulmonary artery. The effects of transvenous cardiac nerve stimulation on sinus rhythm cycle length, ventricular refractory periods and inducibility of monomorphic ventricular tachycardia were evaluated. Sinus rhythm cycle length increased from 620 +/- 24 ms to 723 +/- 30 ms during nerve stimulation with 20 Hz and to 779 +/- 28 ms during stimulation with 40 Hz (p < 0.05). Effective ventricular refractory periods from stimulation sites in non-infarcted right and left ventricular myocardium showed a tendency towards prolongation during cardiac nerve stimulation with shortening after cessation of stimulation. These differences, however, were not significant. In contrast, refractory periods from stimulation sites within the infarcted area remained unchanged during cardiac nerve stimulation. The inducibility of monomorphic ventricular tachycardia by programmed electrical stimulation was reduced during transvenous cardiac nerve stimulation. Pathological examination showed cholinergic nerves in close proximity to the tip of the stimulation catheter in the right pulmonary artery. Transvenous cardiac nerve stimulation in sheep with remote myocardial infarction exhibits electrophysiological effects on the ventricles. Although a parasympathetic effect on the ventricles could not be proven, the observed effects may result from direct stimulation of efferent parasympathetic nerves.


Asunto(s)
Nodo Atrioventricular/fisiopatología , Estimulación Cardíaca Artificial/métodos , Cateterismo Venoso Central/métodos , Infarto del Miocardio/fisiopatología , Infarto del Miocardio/terapia , Sistema Nervioso Parasimpático/fisiopatología , Taquicardia Ventricular/fisiopatología , Animales , Estimulación Cardíaca Artificial/efectos adversos , Modelos Animales de Enfermedad , Terapia por Estimulación Eléctrica , Infarto del Miocardio/patología , Ovinos , Taquicardia Ventricular/etiología , Taquicardia Ventricular/patología , Resultado del Tratamiento
3.
Z Kardiol ; 91(12): 1044-52, 2002 Dec.
Artículo en Alemán | MEDLINE | ID: mdl-12490994

RESUMEN

The Wearable Cardioverter Defibrillator (WCD) is an external defibrillator that automatically detects and treats ventricular tachyarrhythmias without the need for assistance from a bystander while at the same time allowing the patient to ambulate freely. The main components of the system are the defibrillator unit and a chest belt with electrodes for arrhythmia detection and therapy delivery. Between December 1998 and October 2001, 84 patients used the device at our institution. The majority of patients had a history of acute myocardial infarction or coronary artery bypass surgery with an increased risk for sudden cardiac death or were awaiting heart transplantation. During a mean follow-up of 116+/-90 days, 7 episodes of ventricular tachyarrhythmias were detected and terminated successfully by the WCD in 5 patients. In 9720 days, there was one inappropriate shock due to oversensing of electrical noise. Four patients died during follow-up; none of them had a cardiac arrest while wearing the device. Five patients were excluded because of irregularities in device use. An ICD was implanted in 24 patients at the end of the follow-up period. The WCD is effective in detecting and treating ventricular tachyarrhythmias in patients with an intermittently increased risk for sudden cardiac death. Further use of the system in larger patient populations is needed to confirm its safety and cost effectiveness.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica , Anciano , Puente de Arteria Coronaria , Cardioversión Eléctrica/instrumentación , Femenino , Estudios de Seguimiento , Trasplante de Corazón , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio , Factores de Riesgo , Taquicardia Ventricular/terapia , Factores de Tiempo , Fibrilación Ventricular/terapia
7.
Artículo en Alemán | MEDLINE | ID: mdl-24584428

RESUMEN

The limited efficacy of and side effects associated with antiarrhythmic drug therapy have led to renewed interest in non-pharmacologic treatment options for paroxysmal atrial fibrillation. In addition to catheter ablation of the initiating ectopic atrial beats, electrical stimulation of the atrium is a new and promising method to reduce the frequency of arrhythmia recurrences. Recent studies have confirmed the importance of both the initiating triggers and the electrophysiologic substrate for the recurrence and perpetuation, respectively, of atrial fibrillation. Bradycardia and pauses, atrial premature beats, and early recurrence of atrial fibrillation all seem to play an important role for (re-)initiation of an episode. Results from single-site atrial pacing in the high right atrium have shown a reduction of atrial fibrillation episodes and progression into chronic atrial fibrillation in selected groups of patients (brady-tachycardia syndrome and vagally induced atrial fibrillation). Therefore, specific preventive pacing algorithms (atrial overdrive pacing, rate smoothing or rate acceleration after detection of atrial premature beats and termination of a mode-switch) and new pacing sites have recently been investigated in order to address all of these initiation mechanisms and to increase the efficacy of pacing. In studies published so far, the specific pacing algorithms seem to add benefit compared to atrial-based demand (AAI or DDD) pacing alone. Finally, attempts are being made to terminate recurrences of atrial tachycardia or atrial flutter with antitachycardia pacing algorithms in order to avoid progression into atrial fibrillation. Based on experimental and clinical evidence, the initial phase of the majority of atrial tachyarrhythmia recurrences is not 'leading circle reentry'. Most episodes start relatively regular and seem to have an excitable gap, allowing capture and pace termination.

9.
J Interv Card Electrophysiol ; 5(3): 337-40, 2001 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-11500589

RESUMEN

Although radiofrequency (RF) catheter ablation has been shown to be an effective treatment strategy in patients with supraventricular tachycardia, RF ablation may lead to potentially serious complications. We describe a case of a 65-year old man who was transferred for catheter ablation of typical atrial flutter. 21 RF applications (mean energy: 81+/-9 watts) were applied in the temperature-controlled mode (70 degrees C) between a 8-mm tip electrode and an indifferent electrode using a high-power RF generator (100 watts) until bi-directional atrial isthmus block was achieved. After the procedure, a third-degree skin burn (10x2 cm) was observed at the lateral edge of the adhesive indifferent electrode whereas the medial edge of the electrode was not fully attached to the skin surface. This case is one out of 1128 ablation procedures (0.09 %) at our institution using a high-power RF generator. The present study demonstrates a severe skin burn induced by mal-attachment of an indifferent electrode during RF ablation. Long RF energy application times, high-power settings, and heavy sedation may have contributed to the observed severity of skin damage.


Asunto(s)
Aleteo Atrial/cirugía , Quemaduras por Electricidad/etiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Anciano , Aleteo Atrial/diagnóstico , Quemaduras por Electricidad/diagnóstico , Quemaduras por Electricidad/cirugía , Electrodos/efectos adversos , Estudios de Seguimiento , Humanos , Puntaje de Gravedad del Traumatismo , Masculino , Medición de Riesgo , Trasplante de Piel/métodos , Resultado del Tratamiento
11.
Pacing Clin Electrophysiol ; 23(11 Pt 2): 1872-5, 2000 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-11139946

RESUMEN

Previous studies have shown that platelets are activated during atrial fibrillation (AF). However, prophylactic therapy with aspirin is not associated with a reduction of thromboembolic complications in patients with AF. Stimulation of platelet thrombin and ADP receptors causes a release of P-selectin, which is not affected by aspirin. The purpose of this study was to assess the influence of AF on platelet P-selectin expression. Blood samples from 30 patients were studied ex vivo. Nineteen patients had chronic AF (> 3 months), 11 patients were in sinus rhythm (SR). P-selectin expression was determined by flow cytometry (antibody binding capacity [BC]) at baseline and after platelet stimulation with adenosine diphosphate (ADP) and thrombin receptor activating peptide (TRAP). To determine the effect of heart rate and atrial pressure (RAP), measurements were repeated after 10 minutes of ventricular pacing (120 beats/min) in patients with SR. P-selectin expression was increased in patients with AF at baseline (AF: 1329 +/- 81 BC vs SR: 968 +/- 108 BC; P < 0.05) and after stimulation with ADP (AF: 1445 +/- 101 BC vs SR: 1061 +/- 109 BC; P < 0.05) and TRAP (AF: 13,783 +/- 2442 BC vs SR: 5977 +/- 800 BC; P < 0.05). RAP (2.0 +/- 0.5 vs 6.0 +/- 0.8 mmHg; P < 0.01) and atrial rate (75 +/- 5 vs 114 +/- 5 beats/min; P < 0.001) increased during ventricular pacing. However, P-selectin levels remained stable. AF was accompanied by increased P-selectin expression. In contrast, increased ventricular rate and elevated atrial pressure alone had no effect on platelet activity. Further studies are needed to determine if platelet ADP receptor inhibitors offer a therapeutic benefit in patients with AF.


Asunto(s)
Fibrilación Atrial/sangre , Selectina-P/sangre , Adenosina Difosfato/farmacología , Fibrilación Atrial/terapia , Plaquetas/efectos de los fármacos , Plaquetas/metabolismo , Presión Sanguínea , Estimulación Cardíaca Artificial , Enfermedad Crónica , Femenino , Citometría de Flujo , Atrios Cardíacos/fisiopatología , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Proteínas/farmacología , Receptores de Trombina
12.
Pacing Clin Electrophysiol ; 23(11 Pt 1): 1651-60, 2000 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-11138303

RESUMEN

Dual AV node physiology often persists after successful slow pathway (SP) ablation, and the mechanism of tachycardia elimination is unresolved. Therefore, AV node conduction curves were analyzed following successful ablation (4 +/- 1 energy applications) in 85 consecutive patients (58 women, age 50 +/- 2 years) with typical AVNRT. Twenty-seven patients (32%) had complete elimination (group 1) whereas 58 (68%) patients had persistence (group 2) of dual AV node physiology. A significant increase in the AV node Wenckebach cycle length (WB-CL) was observed in both groups (310 +/- 9 to 351 +/- 15 ms in group 1, and 325 +/- 8 to 369 +/- 9 ms in group 2, P < 0.05). A decrease in the fast pathway (FP) ERP (339 +/- 15 to 279 +/- 12 ms) and an increase in the maximum FP AH interval (141 +/- 5 to 171 +/- 7) were observed only in group 1 (P < 0.05). In group 2, no change in the SP ERP (267 +/- 7 to 280 +/- 10 ms) was observed, and the change in the maximum SP-AH following ablation showed a significant inverse relation to the maximum SP-AH at baseline in group 2. In conclusion, (1) an increase in the WB-CL is observed independent of the persistence or elimination of dual physiology after successful ablation; (2) when dual physiology is eliminated, significant changes in the FP ERP and the maximum FP-AH occur; (3) when dual physiology persists, FP physiology and the SP ERP remain unchanged, and a significant inverse relation between the change in the maximum SP-AH following ablation and the maximum baseline SP-AH is observed.


Asunto(s)
Nodo Atrioventricular/fisiopatología , Ablación por Catéter , Sistema de Conducción Cardíaco/fisiopatología , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Nodo Atrioventricular/cirugía , Electrocardiografía , Potenciales Evocados , Femenino , Humanos , Masculino , Persona de Mediana Edad , Taquicardia por Reentrada en el Nodo Atrioventricular/terapia , Resultado del Tratamiento
16.
Am Heart J ; 138(5 Pt 1): 987-93, 1999 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-10539834

RESUMEN

BACKGROUND: The purpose of this study was to determine the incidence and origin of T-wave changes after ablation of an accessory atrioventricular connection (AC), which could either be a sign of damage to the coronary circulation or a result of persistent abnormal repolarization secondary to previously abnormal ventricular activation ("cardiac memory"). METHODS AND RESULTS: Ninety of 107 consecutive patients (33 women and 57 men, mean age 36 +/- 5 years) undergoing successful catheter ablation of an AC were studied. Patients with bundle branch block or more than 1 AC were excluded. Sixty-four patients had manifest preexcitation (group 1) and 26 had a concealed AC (group 2). Immediately after loss of preexcitation, 38 (59%) patients with a manifest AC showed T-wave abnormalities. In contrast, none of the patients with a concealed AC had T-wave abnormalities after ablation (P <.05). The T-wave changes (1) did not correlate with the number or duration of energy applications or with markers of tissue injury; (2) correlated with the location of the AC and the degree of preexcitation, respectively; and (3) completely resolved over a period of weeks to months. None of the patients had recurrence of preexcitation or tachycardia during a mean follow-up of 16 +/- 7 months. CONCLUSIONS: T-wave changes after ablation are most likely caused by "cardiac memory" and are not a sign of myocardial or coronary injury.


Asunto(s)
Nodo Atrioventricular/cirugía , Ablación por Catéter/efectos adversos , Vasos Coronarios/inervación , Electrocardiografía , Isquemia Miocárdica/etiología , Síndrome de Wolff-Parkinson-White/cirugía , Adulto , Circulación Coronaria , Vasos Coronarios/lesiones , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/fisiopatología , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Resultado del Tratamiento
17.
Pacing Clin Electrophysiol ; 22(4 Pt 1): 605-14, 1999 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-10234714

RESUMEN

The two goals of this study were (1) to develop a closed-chest animal model of monomorphic ventricular tachycardia; and (2) to investigate the effect of dual site pacing on inducibility of ventricular tachycardia. In the first part of the study, 10 of 14 sheep underwent successful induction of myocardial infarction by temporary balloon occlusion of the left anterior descending coronary artery. After a follow-up period of 21-43 days, sustained monomorphic ventricular tachycardia could be induced during programmed electrical stimulation using a "clinical" stimulation protocol in 8 of the 10 sheep. The number of ventricular tachycardia episodes per animal varied between 5 and 70. Ventricular fibrillation was never induced during programmed electrical stimulation. Ventricular tachycardia episodes lasted from 30 seconds up to 15 minutes and were terminated by antitachycardia pacing or DC cardioversion. In the second part of the study, the effect of dual site stimulation on ventricular tachycardia inducibility was investigated. High current stimuli from an area within the infarcted zone were given with the S1 programmed stimulation protocol. This dual site stimulation showed no effect on ventricular tachycardia induction during programmed electrical stimulation. This animal model shows a high induction rate of sustained monomorphic ventricular tachycardia in the chronic phase of myocardial infarction. The high incidence of ventricular tachycardia inducibility provides a reliable tool to study new techniques for the prevention of ventricular tachyarrhythmias.


Asunto(s)
Infarto del Miocardio/complicaciones , Taquicardia Ventricular/etiología , Animales , Estimulación Cardíaca Artificial , Cateterismo , Distribución de Chi-Cuadrado , Vasos Coronarios/patología , Modelos Animales de Enfermedad , Cardioversión Eléctrica , Estimulación Eléctrica , Electrocardiografía , Estudios de Seguimiento , Ventrículos Cardíacos , Infarto del Miocardio/patología , Infarto del Miocardio/fisiopatología , Miocardio/patología , Arteria Pulmonar , Reproducibilidad de los Resultados , Ovinos , Taquicardia Ventricular/prevención & control , Taquicardia Ventricular/terapia , Factores de Tiempo
18.
Am J Cardiol ; 83(5B): 91D-97D, 1999 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-10089848

RESUMEN

Primary prevention of sudden arrhythmic death in patients with organic heart disease with poor left ventricular function and/or heart failure is currently a major challenge in cardiology. Amiodarone (with or without beta blockers) and the implantable cardioverter defibrillator (ICD) are considered the 2 major therapeutic tools to prevent sudden arrhythmic death in these patients. Two large trials have been launched to define the prophylactic benefit of the ICD or amiodarone on total mortality in patients that receive optimal heart failure and anti-ischemic treatment but remain at high risk of dying suddenly. The Sudden Cardiac Death in Heart Failure Trial (SCD-Heft) is designed to determine whether amiodarone or the ICD will decrease overall mortality in patients with coronary artery disease or nonischemic cardiomyopathy who are in heart failure New York Heart Association (NYHA) class II or III and have a left ventricular ejection fraction < 35%. The primary endpoint is total mortality; secondary objectives are comparison of arrhythmic and nonarrhythmic mortality and morbidity in the 3 arms as well as quality of life, cost-effectiveness, and incidence of episodes of ventricular tachyarrhythmias. The Multicenter Automatic Defibrillator Implantation Trial (MADIT) II is a follow-up study to the MADIT trial. It examines the prophylactic benefit in coronary artery disease patients with a left ventricular ejection fraction of < 30%, who have had at least 1 myocardial infarction but require no further risk stratification. MADIT II is a sequential design trial that compares ICD versus no ICD therapy. Programmed electrical stimulation to test inducibility of ventricular tachycardia is performed during ICD implantation, and various noninvasive risk markers are tested after randomization. Primary endpoint is total mortality, and secondary objectives are quality-of-life issues as well as cost-effectiveness ratio.


Asunto(s)
Amiodarona/uso terapéutico , Antiarrítmicos/uso terapéutico , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Taquicardia Ventricular/terapia , Disfunción Ventricular Izquierda/terapia , Fibrilación Ventricular/terapia , Adulto , Anciano , Amiodarona/efectos adversos , Antiarrítmicos/efectos adversos , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Multicéntricos como Asunto , Ensayos Clínicos Controlados Aleatorios como Asunto , Tasa de Supervivencia , Taquicardia Ventricular/etiología , Taquicardia Ventricular/mortalidad , Resultado del Tratamiento , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/mortalidad , Fibrilación Ventricular/etiología , Fibrilación Ventricular/mortalidad
19.
Am J Cardiol ; 81(10): 1253-6, 1998 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-9604964

RESUMEN

The findings of our initial study demonstrate for the first time the ability to terminate induced VT/VF reliably (100% of all episodes) by a single, monophasic 230-J shock delivered by the Wearable Cardioverter-Defibrillator (WCD). Although limited by sample size, our data suggest the WCD could be used as a feasible bridge to definitive implantation of an implantable cardioverter-defibrillator in patients in whom risk stratification for sudden death is not completed.


Asunto(s)
Cardioversión Eléctrica , Paro Cardíaco/etiología , Paro Cardíaco/prevención & control , Fibrilación Ventricular/terapia , Anciano , Cardioversión Eléctrica/instrumentación , Electrocardiografía Ambulatoria , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Riesgo