1.
Pediatr Qual Saf ; 6(3): e409, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34046538

RESUMEN

The National Emergency Airway Registry for Children (NEAR4KIDS) Airway Safety Quality Improvement (QI) Bundle is a QI tool to improve the safety of tracheal intubations. The ability to achieve targeted compliance with bundle adherence is a challenge for centers due to competing QI initiatives, lack of interdisciplinary involvement, and time barriers. We applied translational simulations to identify safety and performance gaps contributing to poor compliance and remediate barriers by delivering simulation-based interventions. METHODS: This was a single-center retrospective review following translational simulations to improve compliance with the NEAR4KIDS bundle . The simulation was implemented between March 2018 and December 2018. Bundle adherence was assessed 12 months before simulation and 9 months following simulation. Primary outcomes were compliance with the bundle and utilization of apneic oxygenation. The secondary outcome was the occurrence of adverse tracheal intubation-associated events. RESULTS: Preintervention bundle compliance was 66%, and the application of apneic oxygenation was 27.9%. Following the simulation intervention, bundle compliance increased to 93.7% (P < 0.001) and adherence to apneic oxygenation increased to 77.9% (P < 0.001). There was no difference in the occurrence of tracheal intubation-associated events. CONCLUSIONS: Translational simulation was a safety tool that improved NEAR4KIDS bundle compliance and elucidated factors contributing to successful implementation. Through simulation, we optimized bundle customization through process improvement, fostered a culture of safety, and effectively engaged multidisciplinary teams in this quality initiative to improve adherence to best practices surrounding tracheal intubations.

2.
Crit Care Med ; 49(2): 250-260, 2021 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-33177363

RESUMEN

OBJECTIVES: To evaluate the effect of a tracheal intubation safety bundle on adverse tracheal intubation-associated events across 15 PICUs. DESIGN: Multicenter time-series study. SETTING: PICUs in the United States. PATIENTS: All patients received tracheal intubations in ICUs. INTERVENTIONS: We implemented a tracheal intubation safety bundle as a quality-improvement intervention that includes: 1) quarterly site benchmark performance report and 2) airway safety checklists (preprocedure risk factor, approach, and role planning, preprocedure bedside "time-out," and immediate postprocedure debriefing). We define each quality-improvement phase as baseline (-24 to -12 mo before checklist implementation), benchmark performance reporting only (-12 to 0 mo before checklist implementation), implementation (checklist implementation start to time achieving > 80% bundle adherence), early bundle adherence (0-12 mo), and sustained (late) bundle adherence (12-24 mo). Bundle adherence was defined a priori as greater than 80% of checklist use for tracheal intubations for 3 consecutive months. MEASUREMENTS AND MAIN RESULTS: The primary outcome was the adverse tracheal intubation-associated event, and secondary outcomes included severe tracheal intubation-associated events, multiple tracheal intubation attempts, and hypoxemia less than 80%.From January 2013 to December 2015, out of 19 participating PICUs, 15 ICUs (79%) achieved bundle adherence. Among the 15 ICUs, the adverse tracheal intubation-associated event rates were baseline phase: 217/1,241 (17.5%), benchmark reporting only phase: 257/1,750 (14.7%), early 0-12 month complete bundle compliance phase: 247/1,591 (15.5%), and late 12-24 month complete bundle compliance phase: 137/1,002 (13.7%). After adjusting for patient characteristics and clustering by site, the adverse tracheal intubation-associated event rate significantly decreased compared with baseline: benchmark: odds ratio, 0.83 (0.72-0.97; p = 0.016); early bundle: odds ratio, 0.80 (0.63-1.02; p = 0.074); and late bundle odds ratio, 0.63 (0.47-0.83; p = 0.001). CONCLUSIONS: Effective implementation of a quality-improvement bundle was associated with a decrease in the adverse tracheal intubation-associated event that was sustained for 24 months.


Asunto(s)
Unidades de Cuidado Intensivo Pediátrico/organización & administración , Intubación Intratraqueal/métodos , Mejoramiento de la Calidad/organización & administración , Respiración Artificial/estadística & datos numéricos , Adolescente , Niño , Preescolar , Enfermedad Crítica , Bases de Datos Factuales , Servicio de Urgencia en Hospital/organización & administración , Femenino , Humanos , Masculino , Evaluación de Resultado en la Atención de Salud , Sistema de Registros
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...