Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Virchows Arch ; 484(1): 147-150, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36856760

RESUMEN

In general, endometrioid-defining features such as squamoid morular metaplasia are not thought to be associated with mesonephric adenocarcinoma (MA) and mesonephric-like adenocarcinoma (MLA). Here, we report a case of FGFR2-mutated ovarian MLA with squamoid morular metaplasia accompanied by aberrant nuclear and cytoplasmic ß-catenin expression and CTNNB1 mutation. Histologically, the tumor showed classical MLA histology, including well-formed glands with intraluminal eosinophilic secretions and cells with papillary thyroid carcinoma-like nuclei. Squamoid morular metaplasia was intimately associated with the tumor. Glandular epithelial elements, including those immediately associated with the squamoid morules, were negative for ER, but positive for both GATA3 and PAX8; aberrant ß-catenin expression was limited to the squamoid morules. This case illustrates the ability of mesonephric neoplasia to exhibit histological features previously thought to be restricted to an endometrioid phenotype.


Asunto(s)
Adenocarcinoma , Ovario , Femenino , Humanos , Ovario/patología , beta Catenina/genética , beta Catenina/metabolismo , Adenocarcinoma/patología , Metaplasia , Mutación , Receptor Tipo 2 de Factor de Crecimiento de Fibroblastos/genética , Receptor Tipo 2 de Factor de Crecimiento de Fibroblastos/metabolismo
2.
Access Microbiol ; 5(9)2023.
Artículo en Inglés | MEDLINE | ID: mdl-37841090

RESUMEN

A patient suffered a non-fatal wet drowning in a freshwater lake and developed bacteraemia several days later. Blood culture grew a Gram-negative rod that could not be identified by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). 16S ribosomal RNA sequencing of the isolate identified the microbe as Hydrogenophaga laconesensis - an environmental microbe commonly found in freshwater. The recovery of multiple pathogenic micro-organisms (although not H. laconesensis ) from culture of respiratory specimens prompted the initiation of antibiotic therapy with cefepime and, later, vancomycin. The patient's clinical course gradually improved over the course of 2 weeks and she was ultimately discharged home with minimal sequelae. To our knowledge, this is the first evidence of human infection with bacteria in the genus Hydrogenophaga . Hydrogenophaga may be considered in cases of freshwater near-drowning, and MALDI-TOF MS databases should be updated to include H. laconesensis .

3.
Cancer Cytopathol ; 131(3): 171-178, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36287090

RESUMEN

BACKGROUND: Fine-needle aspiration is used as a diagnostic tool in head and neck oropharyngeal squamous cell carcinoma and its metastases. Prognosis and treatment rely on the presence or absence of the human papilloma virus. The purpose of this study was to validate the performance of the Aptima HPV assay using Hema-Diff stained fine-needle aspiration smears in the diagnosis of human papilloma virus-related oropharyngeal squamous cell carcinoma using a simplified method to obtain tumor cells for testing. METHODS: Patients with a diagnosis of squamous cell carcinoma and positive p16 immunohistochemical staining were identified. Aptima Specimen Transport Media was used to remove tumor cells from the Hema-Diff stained slides using a moistened swab. The selected cells were tested for high risk-human papilloma virus using the Aptima HPV assay and Aptima HPV 16 18/45 genotype assay. The results were compared with the p16 immunohistochemical staining of the related cell block and surgical specimens. RESULTS: Twenty-one of the 21 (100%) p16-positive cases were found to be positive for high risk-human papilloma virus, whereas 20 of 21 (95%) negative cases were found to be negative for high risk-human papilloma virus using the Aptima HPV assay. CONCLUSION: The Aptima HPV assay can be used to detect high-risk human papilloma virus in Hema-Diff stained fine-needle aspiration smears of oropharyngeal squamous cell carcinoma with a sensitivity of 100% and a specificity of 95%. This provides a valuable alternative to p16 immunohistochemical staining of cell block sections that often lack appropriate numbers of tumor cells.


Asunto(s)
Carcinoma de Células Escamosas , Neoplasias de Cabeza y Cuello , Infecciones por Papillomavirus , Humanos , Carcinoma de Células Escamosas de Cabeza y Cuello , Biopsia con Aguja Fina/métodos , Carcinoma de Células Escamosas/patología , Virus del Papiloma Humano , Papillomaviridae/genética , Inhibidor p16 de la Quinasa Dependiente de Ciclina , Biomarcadores de Tumor/análisis
4.
WMJ ; 122(5): 432-433, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38180940

Asunto(s)
COVID-19 , Humanos , Pandemias
5.
Front Microbiol ; 13: 970233, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36386626

RESUMEN

Point-of-care tests are highly valuable in providing fast results for medical decisions for greater flexibility in patient care. Many diagnostic tests, such as ELISAs, that are commonly used within clinical laboratory settings require trained technicians, laborious workflows, and complex instrumentation hindering their translation into point-of-care applications. Herein, we demonstrate the use of a homogeneous, bioluminescent-based, split reporter platform that enables a simple, sensitive, and rapid method for analyte detection in clinical samples. We developed this point-of-care application using an optimized ternary, split-NanoLuc luciferase reporter system that consists of two small reporter peptides added as appendages to analyte-specific affinity reagents. A bright, stable bioluminescent signal is generated as the affinity reagents bind to the analyte, allowing for proximity-induced complementation between the two reporter peptides and the polypeptide protein, in addition to the furimazine substrate. Through lyophilization of the stabilized reporter system with the formulated substrate, we demonstrate a shelf-stable, all-in-one, add-and-read analyte-detection system for use in complex sample matrices at the point-of-care. We highlight the modularity of this platform using two distinct SARS-CoV-2 model systems: SARS-CoV-2 N-antigen detection for active infections and anti-SARS-CoV-2 antibodies for immunity status detection using chemically conjugated or genetically fused affinity reagents, respectively. This technology provides a simple and standardized method to develop rapid, robust, and sensitive analyte-detection assays with flexible assay formatting making this an ideal platform for research, clinical laboratory, as well as point-of-care applications utilizing a simple handheld luminometer.

6.
Nat Commun ; 13(1): 4717, 2022 08 11.
Artículo en Inglés | MEDLINE | ID: mdl-35953484

RESUMEN

Two years after the emergence of SARS-CoV-2, there is still a need for better ways to assess the risk of transmission in congregate spaces. We deployed active air samplers to monitor the presence of SARS-CoV-2 in real-world settings across communities in the Upper Midwestern states of Wisconsin and Minnesota. Over 29 weeks, we collected 527 air samples from 15 congregate settings. We detected 106 samples that were positive for SARS-CoV-2 viral RNA, demonstrating that SARS-CoV-2 can be detected in continuous air samples collected from a variety of real-world settings. We expanded the utility of air surveillance to test for 40 other respiratory pathogens. Surveillance data revealed differences in timing and location of SARS-CoV-2 and influenza A virus detection. In addition, we obtained SARS-CoV-2 genome sequences from air samples to identify variant lineages. Collectively, this shows air sampling is a scalable, high throughput surveillance tool that could be used in conjunction with other methods for detecting respiratory pathogens in congregate settings.


Asunto(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , COVID-19/epidemiología , Humanos , Minnesota/epidemiología , ARN Viral/genética , SARS-CoV-2/genética , Wisconsin/epidemiología
7.
Sci Transl Med ; 14(657): eabm4908, 2022 08 10.
Artículo en Inglés | MEDLINE | ID: mdl-35579540

RESUMEN

The SARS-CoV-2 B.1.621 (Mu) variant emerged in January 2021 and was categorized as a variant of interest by the World Health Organization in August 2021. This designation prompted us to study the sensitivity of this variant to antibody neutralization. In a live virus neutralization assay with serum samples from individuals vaccinated with the Pfizer/BioNTech or Moderna mRNA vaccines, we measured neutralization antibody titers against B.1.621, an early isolate (spike 614D), and a variant of concern (B.1.351, Beta variant). We observed reduced neutralizing antibody titers against the B.1.621 variant (3.4- to 7-fold reduction, depending on the serum sample and time after the second vaccination) compared to the early isolate and a similar reduction when compared to B.1.351. Likewise, convalescent serum from hamsters previously infected with an early isolate neutralized B.1.621 to a lower degree. Despite this antibody titer reduction, hamsters could not be efficiently rechallenged with the B.1.621 variant, suggesting that the immune response to the first infection is adequate to provide protection against a subsequent infection with the B.1.621 variant.


Asunto(s)
COVID-19 , Proteínas del Envoltorio Viral , Anticuerpos Neutralizantes , Anticuerpos Antivirales , COVID-19/terapia , Humanos , Inmunización Pasiva , Glicoproteínas de Membrana/genética , Pruebas de Neutralización , SARS-CoV-2 , Glicoproteína de la Espiga del Coronavirus/genética , Vacunación , Proteínas del Envoltorio Viral/genética , Sueroterapia para COVID-19
8.
medRxiv ; 2022 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-35378751

RESUMEN

Two years after the emergence of SARS-CoV-2, there is still a need for better ways to assess the risk of transmission in congregate spaces. We deployed active air samplers to monitor the presence of SARS-CoV-2 in real-world settings across communities in the Upper Midwestern states of Wisconsin and Minnesota. Over 29 weeks, we collected 527 air samples from 15 congregate settings and detected 106 SARS-CoV-2 positive samples, demonstrating SARS-CoV-2 can be detected in air collected from daily and weekly sampling intervals. We expanded the utility of air surveillance to test for 40 other respiratory pathogens. Surveillance data revealed differences in timing and location of SARS-CoV-2 and influenza A virus detection in the community. In addition, we obtained SARS-CoV-2 genome sequences from air samples to identify variant lineages. Collectively, this shows air surveillance is a scalable, cost-effective, and high throughput alternative to individual testing for detecting respiratory pathogens in congregate settings.

9.
Cell Rep ; 38(7): 110394, 2022 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-35139368

RESUMEN

The emergence of the SARS-CoV-2 Delta variant (B.1.617.2) raises concerns about potential reduced sensitivity of the virus to antibody neutralization and subsequent vaccine breakthrough infections. Here, we use a live virus neutralization assay with sera from Pfizer- and Moderna-vaccinated individuals to examine neutralizing antibody titers against SARS-CoV-2 and observe a 3.9- and 2.7-fold reduction, respectively, in neutralizing antibody titers against the Delta variant compared with an early isolate bearing only a D614G substitution in its spike protein. We observe similar reduced sensitivity with sera from hamsters that were previously infected with an early isolate of SARS-CoV-2. Despite this reduction in neutralizing antibody titers against the Delta variant, hamsters previously infected (up to 15 months earlier) with an early isolate are protected from infection with the Delta variant, suggesting that the immune response to the first infection is sufficient to provide protection against subsequent infection with the Delta variant.


Asunto(s)
Inmunidad Adaptativa , COVID-19/inmunología , SARS-CoV-2/inmunología , Animales , Anticuerpos Neutralizantes/inmunología , Anticuerpos Antivirales/inmunología , COVID-19/transmisión , COVID-19/virología , Vacunas contra la COVID-19/inmunología , Cricetinae , Modelos Animales de Enfermedad , Humanos , Reinfección/inmunología , Reinfección/transmisión , Reinfección/virología , SARS-CoV-2/genética , Carga Viral
10.
Int J Gynecol Pathol ; 41(4): 378-388, 2022 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-34380970

RESUMEN

The ability to distinguish endometrial serous carcinoma (SC) from high-grade endometrioid adenocarcinoma is of great importance given their differences in prognosis and management. In practice, this distinction typically relies upon the use of a focused immunohistochemical panel including p53, p16, and mismatch repair proteins. The expression of p16 is characteristically strong and diffuse in SCs, and weak and/or patchy in many high-grade endometrioid adenocarcinomas. Here, we report a subset of SCs that are entirely negative for p16 immunostaining, a pattern we refer to as "p16 null." This pattern was identified in 2 of 63 cases of SC diagnosed at our institution-1 with histologically classic features and 1 with ambiguous high-grade histologic features. These tumors otherwise showed a SC signature by immunohistochemical and demonstrated an SC pattern of genetic mutations. No mutation in the gene for p16, cyclin-dependent kinase inhibitor 2A (CDKN2A), was identified in either case. However, molecular correlates for the absent p16 expression were present, including homozygous deletion of CDKN2A in one case and hemizygous deletion of CDKN2A with promotor hypermethylation of the remaining allele in the other case. To our knowledge, this constitutes the first report conclusively demonstrating the existence of a small subset of SCs that are completely negative by p16 immunohistochemistry, and the molecular lesions responsible for this pattern. In the context of an otherwise clinically and histologically classic example of SC, we endorse this "null" p16 staining pattern as an alternative aberrant staining pattern that should not deter one from committing to this diagnosis.


Asunto(s)
Carcinoma Endometrioide , Cistadenocarcinoma Seroso , Neoplasias Endometriales , Biomarcadores de Tumor/genética , Biomarcadores de Tumor/metabolismo , Carcinoma Endometrioide/diagnóstico , Carcinoma Endometrioide/genética , Carcinoma Endometrioide/metabolismo , Inhibidor p16 de la Quinasa Dependiente de Ciclina/metabolismo , Cistadenocarcinoma Seroso/genética , Neoplasias Endometriales/diagnóstico , Neoplasias Endometriales/genética , Neoplasias Endometriales/metabolismo , Femenino , Homocigoto , Humanos , Eliminación de Secuencia , Coloración y Etiquetado
11.
J Infect Dis ; 225(2): 282-286, 2022 01 18.
Artículo en Inglés | MEDLINE | ID: mdl-34875072

RESUMEN

In hamsters, SARS-CoV-2 infection at the same time as or before H3N2 influenza virus infection resulted in significantly reduced influenza virus titers in the lungs and nasal turbinates. This interference may be correlated with SARS-CoV-2-induced expression of MX1.


Asunto(s)
COVID-19 , Subtipo H3N2 del Virus de la Influenza A , Proteínas de Resistencia a Mixovirus/metabolismo , SARS-CoV-2 , Replicación Viral , Animales , Coinfección , Cricetinae , Humanos , Mesocricetus
12.
mBio ; 12(6): e0297521, 2021 12 21.
Artículo en Inglés | MEDLINE | ID: mdl-34781736

RESUMEN

Several severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants have arisen that exhibit increased viral transmissibility and partial evasion of immunity induced by natural infection and vaccination. To address the specific antibody targets that were affected by recent viral variants, we generated 43 monoclonal antibodies (mAbs) from 10 convalescent donors that bound three distinct domains of the SARS-CoV-2 spike. Viral variants harboring mutations at K417, E484, and N501 could escape most of the highly potent antibodies against the receptor binding domain (RBD). Despite this, we identified 12 neutralizing mAbs against three distinct regions of the spike protein that neutralize SARS-CoV-2 and variants of concern (VOCs), including B.1.1.7 (alpha), P.1 (gamma), and B.1.617.2 (delta). Notably, antibodies targeting distinct epitopes could neutralize discrete variants, suggesting that different variants may have evolved to disrupt the binding of particular neutralizing antibody classes. These results underscore that humans exposed to the first pandemic wave of prototype SARS-CoV-2 possess neutralizing antibodies against current variants and that it is critical to induce antibodies targeting multiple distinct epitopes of the spike that can neutralize emerging variants of concern. IMPORTANCE We describe the binding and neutralization properties of a new set of human monoclonal antibodies derived from memory B cells of 10 coronavirus disease 2019 (COVID-19) convalescent donors in the first pandemic wave of prototype SARS-CoV-2. There were 12 antibodies targeting distinct epitopes on spike, including two sites on the RBD and one on the N-terminal domain (NTD), that displayed cross-neutralization of VOCs, for which distinct antibody targets could neutralize discrete variants. This work underlines that natural infection by SARS-CoV-2 induces effective cross-neutralization against only some VOCs and supports the need for COVID-19 vaccination for robust induction of neutralizing antibodies targeting multiple epitopes of the spike protein to combat the current SARS-CoV-2 VOCs and any others that might emerge in the future.


Asunto(s)
Anticuerpos Antivirales/sangre , Anticuerpos ampliamente neutralizantes/sangre , COVID-19/inmunología , SARS-CoV-2/inmunología , Glicoproteína de la Espiga del Coronavirus/inmunología , Adulto , Anticuerpos Monoclonales/inmunología , Anticuerpos Antivirales/inmunología , Anticuerpos ampliamente neutralizantes/inmunología , Convalecencia , Epítopos/inmunología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pruebas de Neutralización , Pandemias , Plasma/inmunología , Unión Proteica , SARS-CoV-2/genética , Glicoproteína de la Espiga del Coronavirus/genética
13.
PLoS Pathog ; 17(8): e1009849, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34424945

RESUMEN

The emergence of divergent SARS-CoV-2 lineages has raised concern that novel variants eliciting immune escape or the ability to displace circulating lineages could emerge within individual hosts. Though growing evidence suggests that novel variants arise during prolonged infections, most infections are acute. Understanding how efficiently variants emerge and transmit among acutely-infected hosts is therefore critical for predicting the pace of long-term SARS-CoV-2 evolution. To characterize how within-host diversity is generated and propagated, we combine extensive laboratory and bioinformatic controls with metrics of within- and between-host diversity to 133 SARS-CoV-2 genomes from acutely-infected individuals. We find that within-host diversity is low and transmission bottlenecks are narrow, with very few viruses founding most infections. Within-host variants are rarely transmitted, even among individuals within the same household, and are rarely detected along phylogenetically linked infections in the broader community. These findings suggest that most variation generated within-host is lost during transmission.


Asunto(s)
COVID-19/virología , Variación Genética , SARS-CoV-2/genética , Enfermedad Aguda , COVID-19/transmisión , Evolución Molecular , Genoma Viral , Humanos , Filogenia , SARS-CoV-2/patogenicidad , Factores de Tiempo
14.
Nat Commun ; 12(1): 4317, 2021 07 14.
Artículo en Inglés | MEDLINE | ID: mdl-34262053

RESUMEN

The COVID-19 pandemic exposed difficulties in scaling current quantitative PCR (qPCR)-based diagnostic methodologies for large-scale infectious disease testing. Bottlenecks include lengthy multi-step processes for nucleic acid extraction followed by qPCR readouts, which require costly instrumentation and infrastructure, as well as reagent and plastic consumable shortages stemming from supply chain constraints. Here we report an Oil Immersed Lossless Total Analysis System (OIL-TAS), which integrates RNA extraction and detection onto a single device that is simple, rapid, cost effective, and requires minimal supplies and infrastructure to perform. We validated the performance of OIL-TAS using contrived SARS-CoV-2 viral particle samples and clinical nasopharyngeal swab samples. OIL-TAS showed a 93% positive predictive agreement (n = 57) and 100% negative predictive agreement (n = 10) with clinical SARS-CoV-2 qPCR assays in testing clinical samples, highlighting its potential to be a faster, cheaper, and easier-to-deploy alternative for infectious disease testing.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , SARS-CoV-2/aislamiento & purificación , Prueba de Ácido Nucleico para COVID-19/economía , Prueba de Ácido Nucleico para COVID-19/instrumentación , Diseño de Equipo , Humanos , Técnicas de Diagnóstico Molecular , Nasofaringe/virología , Técnicas de Amplificación de Ácido Nucleico , ARN Viral/genética , ARN Viral/aislamiento & purificación , Reproducibilidad de los Resultados , SARS-CoV-2/genética , Sensibilidad y Especificidad , Factores de Tiempo , Virión/genética , Virión/aislamiento & purificación
15.
Res Sq ; 2021 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-34312615

RESUMEN

Several severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants have arisen that exhibit increased viral transmissibility and partial evasion of immunity induced by natural infection and vaccination. To address the specific antibody targets that were affected by recent viral variants, we generated 43 monoclonal antibodies (mAbs) from 10 convalescent donors that bound three distinct domains of the SARS-CoV-2 spike. Viral variants harboring mutations at K417, E484 and N501 could escape most of the highly potent antibodies against the receptor binding domain (RBD). Despite this, we identified 12 neutralizing mAbs against three distinct regions of the spike protein that neutralize SARS-CoV-2 and the variants of concern, including B.1.1.7 (alpha), P.1 (gamma) and B.1.617.2 (delta). Notably, antibodies targeting distinct epitopes could neutralize discrete variants, suggesting different variants may have evolved to disrupt the binding of particular neutralizing antibody classes. These results underscore that humans exposed to wildtype (WT) SARS-CoV-2 do possess neutralizing antibodies against current variants and that it is critical to induce antibodies targeting multiple distinct epitopes of the spike that can neutralize emerging variants of concern.

16.
Clin Infect Dis ; 73(6): e1329-e1336, 2021 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-33857303

RESUMEN

BACKGROUND: Healthcare personnel (HCP) are at increased risk of infection with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). We posit that current infection control guidelines generally protect HCP from SARS-CoV-2 infection in a healthcare setting. METHODS: In this retrospective case series, we used viral genomics to investigate the likely source of SARS-CoV-2 infection in HCP at a major academic medical institution in the Upper Midwest of the United States between 25 March and 27 December 2020. We obtained limited epidemiological data through informal interviews and review of the electronic health record and combined this information with healthcare-associated viral sequences and viral sequences collected in the broader community to infer the most likely source of infection in HCP. RESULTS: We investigated SARS-CoV-2 infection clusters involving 95 HCP and 137 possible patient contact sequences. The majority of HCP infections could not be linked to a patient or coworker (55 of 95 [57.9%]) and were genetically similar to viruses circulating concurrently in the community. We found that 10.5% of HCP infections (10 of 95) could be traced to a coworker. Strikingly, only 4.2% (4 of 95) could be traced to a patient source. CONCLUSIONS: Infections among HCP add further strain to the healthcare system and put patients, HCP, and communities at risk. We found no evidence for healthcare-associated transmission in the majority of HCP infections evaluated. Although we cannot rule out the possibility of cryptic healthcare-associated transmission, it appears that HCP most commonly become infected with SARS-CoV-2 via community exposure. This emphasizes the ongoing importance of mask wearing, physical distancing, robust testing programs, and rapid distribution of vaccines.


Asunto(s)
COVID-19 , SARS-CoV-2 , Atención a la Salud , Personal de Salud , Humanos , Estudios Retrospectivos , Estados Unidos/epidemiología
17.
medRxiv ; 2021 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-33655260

RESUMEN

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) control in the United States remains hampered, in part, by testing limitations. We evaluated a simple, outdoor, mobile, colorimetric reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay workflow where self-collected saliva is tested for SARS-CoV-2 RNA. From July 16 to November 19, 2020, 4,704 surveillance samples were collected from volunteers and tested for SARS-CoV-2 at 5 sites. A total of 21 samples tested positive for SARS-CoV-2 by RT-LAMP; 12 were confirmed positive by subsequent quantitative reverse-transcription polymerase chain reaction (qRT-PCR) testing, while 8 were negative for SARS-CoV-2 RNA, and 1 could not be confirmed because the donor did not consent to further molecular testing. We estimated the RT-LAMP assay's false-negative rate from July 16 to September 17, 2020 by pooling residual heat-inactivated saliva that was unambiguously negative by RT-LAMP into groups of 6 or less and testing for SARS-CoV-2 RNA by qRT-PCR. We observed a 98.8% concordance between the RT-LAMP and qRT-PCR assays, with only 5 of 421 RT-LAMP negative pools (2,493 samples) testing positive in the more sensitive qRT-PCR assay. Overall, we demonstrate a rapid testing method that can be implemented outside the traditional laboratory setting by individuals with basic molecular biology skills and can effectively identify asymptomatic individuals who would not typically meet the criteria for symptom-based testing modalities.

18.
J Biomol Tech ; 32(3): 137-147, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-35035293

RESUMEN

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) control in the United States remains hampered, in part, by testing limitations. We evaluated a simple, outdoor, mobile, colorimetric reverse-transcription loop-mediated isothermal amplification (RT-LAMP) assay workflow where self-collected saliva is tested for SARS-CoV-2 RNA. From July 16, 2020, to November 19, 2020, surveillance samples (n = 4704) were collected from volunteers and tested for SARS-CoV-2 at 5 sites. Twenty-one samples tested positive for SARS-CoV-2 by RT-LAMP; 12 were confirmed positive by subsequent quantitative reverse-transcription polymerase chain reaction (qRT-PCR) testing, whereas 8 tested negative for SARS-CoV-2 RNA, and 1 could not be confirmed because the donor did not consent to further molecular testing. We estimated the false-negative rate of the RT-LAMP assay only from July 16, 2020, to September 17, 2020 by pooling residual heat-inactivated saliva that was unambiguously negative by RT-LAMP into groups of 6 or fewer and testing for SARS-CoV-2 RNA by qRT-PCR. We observed a 98.8% concordance between the RT-LAMP and qRT-PCR assays, with only 5 of 421 RT-LAMP-negative pools (2493 total samples) testing positive in the more-sensitive qRT-PCR assay. Overall, we demonstrate a rapid testing method that can be implemented outside the traditional laboratory setting by individuals with basic molecular biology skills and that can effectively identify asymptomatic individuals who would not typically meet the criteria for symptom-based testing modalities.


Asunto(s)
COVID-19 , SARS-CoV-2 , Prueba de COVID-19 , Humanos , Técnicas de Diagnóstico Molecular , Técnicas de Amplificación de Ácido Nucleico , ARN Viral/genética , Sensibilidad y Especificidad
19.
J Med Virol ; 93(7): 4438-4445, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33350484

RESUMEN

The hologic panther fusion (PF) platform provides fully automated CE marked diagnostics for respiratory viruses, including the recently discovered severe acute respiratory syndrome-coronavirus 2 (SARS-CoV-2) by a transcription mediated amplification (TMA) assay, but not for the endemic human coronaviruses (hCoV). Therefore, a laboratory developed test (LDT) comprising a multiplexed reverse transcription polymerase chain reaction (RT-PCR) protocol that detects and differentiates the four hCoV NL63, 229E, HKU1, and OC43 was adapted on the PF. The novel CE marked Aptima SARS-CoV-2 TMA and the LDT for hCoV were validated with 321 diagnostic specimens from the upper and lower respiratory tract in comparison to two SARS-CoV-2 RT-PCRs (PF E-gene RT-PCR and genesig RT-PCR, 157 specimens) or the R-GENE hCoV/hParaFlu RT-PCR (164 specimens), respectively. For the endemic hCoV, results were 96.3% concordant with two specimens discordantly positive in the PF and four specimens discordantly positive in the R-GENE assay. All discordantly positive samples had Ct values between 33 and 39. The PF hCoV LDT identified 23 hCoV positive specimens as NL63, 15 as 229E, 15 as HKU1, and 25 as OC43. The Aptima SARS-CoV-2 TMA gave 99.4% concordant results compared to the consensus results with a single specimen discordantly positive. Moreover, 36 samples from proficiency testing panels were detected and typed correctly by both novel methods. In conclusion, the SARS-CoV-2 TMA and the LDT for hCoV enhanced the diagnostic spectrum of the PF for all coronaviruses circulating globally for a multitude of diagnostic materials from the upper and lower respiratory tract.


Asunto(s)
Alphacoronavirus/genética , COVID-19/diagnóstico , Coronavirus Humano 229E/genética , Coronavirus Humano NL63/genética , Coronavirus Humano OC43/genética , SARS-CoV-2/genética , Humanos , Técnicas de Amplificación de Ácido Nucleico/métodos , Sistema Respiratorio/virología , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos
20.
PLoS One ; 15(12): e0244882, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33382861

RESUMEN

SARS-CoV-2 testing is crucial to controlling the spread of this virus, yet shortages of nucleic acid extraction supplies and other key reagents have hindered the response to COVID-19 in the US. Several groups have described loop-mediated isothermal amplification (LAMP) assays for SARS-CoV-2, including testing directly from nasopharyngeal swabs and eliminating the need for reagents in short supply. Frequent surveillance of individuals attending work or school is currently unavailable to most people but will likely be necessary to reduce the ~50% of transmission that occurs when individuals are nonsymptomatic. Here we describe a fluorescence-based RT-LAMP test using direct nasopharyngeal swab samples and show consistent detection in clinically confirmed primary samples with a limit of detection (LOD) of ~625 copies/µl, approximately 100-fold lower sensitivity than qRT-PCR. While less sensitive than extraction-based molecular methods, RT-LAMP without RNA extraction is fast and inexpensive. Here we also demonstrate that adding a lysis buffer directly into the RT-LAMP reaction improves the sensitivity of some samples by approximately 10-fold. Furthermore, purified RNA in this assay achieves a similar LOD to qRT-PCR. These results indicate that high-throughput RT-LAMP testing could augment qRT-PCR in SARS-CoV-2 surveillance programs, especially while the availability of qRT-PCR testing and RNA extraction reagents is constrained.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19 , COVID-19 , Técnicas de Diagnóstico Molecular , Técnicas de Amplificación de Ácido Nucleico , ARN Viral/genética , SARS-CoV-2/genética , COVID-19/diagnóstico , COVID-19/genética , Cartilla de ADN/química , Cartilla de ADN/genética , Humanos , Límite de Detección , Nasofaringe/virología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...