Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 137
Filtrar
1.
J Phys Chem A ; 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38770785

RESUMEN

Aerosols transform between physical phases, as they respond to variations in environmental conditions. There are many industries that depend on these dynamic processes of crystallization and dissolution. Here, a single particle technique (an electrodynamic balance) is used to explore the crystallization and dissolution dynamics of a model system, sodium chloride. The physical and environmental factors that influence the dynamics of crystal formation from a saline droplet (whose initial radius is ∼25 µm) and the kinetics of water adsorption onto dried particles are examined. The drying relative humidity (RH) is shown to impact the physical properties of the dried particle. When a saline droplet is injected into an airflow at an RH close to the efflorescence RH (ERH, 45%), an individual single crystal forms. By contrast, when a compositionally equivalent saline droplet is injected into dry air (RH ∼ 0%), a salt crystal made of multiple crystalline particles is formed. Subsequent to crystallization, the crystal shape, morphology, and surface area were all found to affect the dissolution dynamics of the dried particle. Additionally, we report that the difference between the deliquesce RH and environmental RH significantly impacts the dissolution time scale.

2.
Nat Commun ; 15(1): 3487, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38664424

RESUMEN

An improved understanding of the underlying physicochemical properties of respiratory aerosol that influence viral infectivity may open new avenues to mitigate the transmission of respiratory diseases such as COVID-19. Previous studies have shown that an increase in the pH of respiratory aerosols following generation due to changes in the gas-particle partitioning of pH buffering bicarbonate ions and carbon dioxide is a significant factor in reducing SARS-CoV-2 infectivity. We show here that a significant increase in SARS-CoV-2 aerostability results from a moderate increase in the atmospheric carbon dioxide concentration (e.g. 800 ppm), an effect that is more marked than that observed for changes in relative humidity. We model the likelihood of COVID-19 transmission on the ambient concentration of CO2, concluding that even this moderate increase in CO2 concentration results in a significant increase in overall risk. These observations confirm the critical importance of ventilation and maintaining low CO2 concentrations in indoor environments for mitigating disease transmission. Moreover, the correlation of increased CO2 concentration with viral aerostability need to be better understood when considering the consequences of increases in ambient CO2 levels in our atmosphere.


Asunto(s)
COVID-19 , Dióxido de Carbono , SARS-CoV-2 , Dióxido de Carbono/metabolismo , Dióxido de Carbono/análisis , COVID-19/transmisión , COVID-19/virología , Humanos , Concentración de Iones de Hidrógeno , Aerosoles , Humedad , Ventilación , Aerosoles y Gotitas Respiratorias/metabolismo , Aerosoles y Gotitas Respiratorias/virología , Atmósfera/química
3.
Microbiology (Reading) ; 170(1)2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38180461

RESUMEN

Group A streptococcus (GAS) infections result in more than 500 000 deaths annually. Despite mounting evidence for airborne transmission of GAS, little is known about its stability in aerosol. Measurements of GAS airborne stability were carried out using the Controlled Electrodynamic Levitation and Extraction of Bioaerosols onto a Substrate (CELEBS) instrument. CELEBS measurements with two different isolates of GAS suggest that it is aerostable, with approximately 70 % of bacteria remaining viable after 20 min of levitation at 50 % relative humidity (RH), with lower survival as RH was reduced. GAS airborne viability loss was driven primarily by desiccation and efflorescence (i.e. salt crystallization), with high pH also potentially playing a role, given reduced survival in bicarbonate containing droplet compositions. At low enough RH for efflorescence to occur, a greater proportion of organic components in the droplet appeared to protect the bacteria from efflorescence. These first insights into the aerosol stability of GAS indicate that airborne transmission of these respiratory tract bacteria may occur, and that both the composition of the droplet containing the bacteria, and the RH of the air affect the duration of bacterial survival in this environment. Future studies will explore a broader range of droplet and air compositions and include a larger selection of GAS strains.


Asunto(s)
Cloruro de Sodio , Streptococcus pyogenes , Aerosoles
4.
Langmuir ; 40(1): 734-743, 2024 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-38128476

RESUMEN

A deeper understanding of the key processes that determine the particle morphologies generated during aerosol droplet drying is highly desirable for spray-drying of powdered pharmaceuticals and foods, predicting the properties of atmospheric particles, and monitoring disease transmission. Particle morphologies are affected by the drying kinetics of the evaporating droplets, which are in turn influenced by the composition of the initial droplet as well as the drying conditions. Herein, we use polymerization-induced self-assembly (PISA) to prepare three types of sterically stabilized diblock copolymer nanoparticles comprising the same steric stabilizer block and differing core blocks with z-average diameters ranging from 32 to 238 nm. These well-defined nanoparticles enable a systematic investigation of the effect of the nanoparticle size and composition on the drying kinetics of aqueous aerosol droplets (20-28 µm radius) and the final morphology of the resulting microparticles. A comparative kinetics electrodynamic balance was used to obtain evaporation profiles for 10 examples of nanoparticles at a relative humidity (RH) of 0, 45, or 65%. Nanoparticles comprising the same core block with mean diameters of 32, 79, and 214 nm were used to produce microparticles, which were dried under different RH conditions in a falling droplet column. Scanning electron microscopy was used to examine how the drying kinetics influenced the final microparticle morphology. For dilute droplets, the chemical composition of the nanoparticles had no effect on the evaporation rate. However, employing smaller nanoparticles led to the formation of dried microparticles with a greater degree of buckling.

5.
Bone Joint Res ; 12(10): 636-643, 2023 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-37813391

RESUMEN

Aims: Orthopaedic surgery uses many varied instruments with high-speed, high-impact, thermal energy and sometimes heavy instruments, all of which potentially result in aerosolization of contaminated blood, tissue, and bone, raising concerns for clinicians' health. This study quantifies the aerosol exposure by measuring the number and size distribution of the particles reaching the lead surgeon during key orthopaedic operations. Methods: The aerosol yield from 17 orthopaedic open surgeries (on the knee, hip, and shoulder) was recorded at the position of the lead surgeon using an Aerodynamic Particle Sizer (APS; 0.5 to 20 µm diameter particles) sampling at 1 s time resolution. Through timestamping, detected aerosol was attributed to specific procedures. Results: Diathermy (electrocautery) and oscillating bone saw use had a high aerosol yield (> 100 particles detected per s) consistent with high exposure to aerosol in the respirable range (< 5 µm) for the lead surgeon. Pulsed lavage, reaming, osteotome use, and jig application/removal were medium aerosol yield (10 to 100 particles s-1). However, pulsed lavage aerosol was largely attributed to the saline jet, osteotome use was always brief, and jig application/removal had a large variability in the associated aerosol yield. Suctioning (with/without saline irrigation) had a low aerosol yield (< 10 particles s-1). Most surprisingly, other high-speed procedures, such as drilling and screwing, had low aerosol yields. Conclusion: This work suggests that additional precautions should be recommended for diathermy and bone sawing, such as enhanced personal protective equipment or the use of suction devices to reduce exposure.

6.
J R Soc Interface ; 20(203): 20230062, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37340783

RESUMEN

The mechanistic factors hypothesized to be key drivers for the loss of infectivity of viruses in the aerosol phase often remain speculative. Using a next-generation bioaerosol technology, we report measurements of the aero-stability of several SARS-CoV-2 variants of concern in aerosol droplets of well-defined size and composition at high (90%) and low (40%) relative humidity (RH) upwards of 40 min. When compared with the ancestral virus, the infectivity of the Delta variant displayed different decay profiles. At low RH, a loss of viral infectivity of approximately 55% was observed over the initial 5 s for both variants. Regardless of RH and variant, greater than 95% of the viral infectivity was lost after 40 min of being aerosolized. Aero-stability of the variants correlate with their sensitivities to alkaline pH. Removal of all acidic vapours dramatically increased the rate of infectivity decay, with 90% loss after 2 min, while the addition of nitric acid vapour improved aero-stability. Similar aero-stability in droplets of artificial saliva and growth medium was observed. A model to predict loss of viral infectivity is proposed: at high RH, the high pH of exhaled aerosol drives viral infectivity loss; at low RH, high salt content limits the loss of viral infectivity.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/epidemiología , Aerosoles y Gotitas Respiratorias
7.
J Voice ; 2023 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-37248120

RESUMEN

INTRODUCTION: Phonation and speech are known sources of respirable aerosol in humans. Voice assessment and treatment manipulate all the subsystems of voice production, and previous work (Saccente-Kennedy et al., 2022) has demonstrated such activities can generate >10 times more aerosol than conversational speech and 30 times more aerosol than breathing. Aspects of voice therapy may therefore be considered aerosol generating procedures and pose a greater risk of potential airborne pathogen (eg, SARS-CoV-2) transmission than typical speech. Effective mitigation measures may be required to ensure safe service delivery for therapist and patient. OBJECTIVE: To assess the effectiveness of mitigation measures in reducing detectable respirable aerosol produced by voice assessment/therapy. METHODS: We recruited 15 healthy participants (8 cis-males, 7 cis-females), 9 of whom were voice-specialist speech-language pathologists. Optical Particle Sizers (OPS) (Model 3330, TSI) were used to measure the number concentration of respirable aerosol particles (0.3 µm-10 µm) generated during a selection of voice assessment/therapy tasks, both with and without mitigation measures in place. Measurements were performed in a laminar flow operating theatre, with near-zero background aerosol concentration, allowing us to quantify the number concentration of respiratory aerosol particles produced. Mitigation measures included the wearing of Type IIR fluid resistant surgical masks, wrapping the same masks around the end of straws, and the use of heat and moisture exchange microbiological filters (HMEFs) for a water resistance therapy (WRT) task. RESULTS: All unmitigated therapy tasks produced more aerosol than unmasked breathing or speaking. Mitigation strategies reduced detectable aerosol from all tasks to a level significantly below, or no different to, that of unmasked breathing. Pooled filtration efficiencies determined that Type IIR surgical masks reduced detectable aerosol by 90%. Surgical masks wrapped around straws reduced detectable aerosol by 96%. HMEF filters were 100% effective in mitigating the aerosol from WRT, the exercise that generated more aerosol than any other task in the unmitigated condition. CONCLUSIONS: Voice therapy and assessment causes the release of significant quantities of respirable aerosol. However, simple mitigation strategies can reduce emitted aerosol concentrations to levels comparable to unmasked breathing.

8.
J Phys Chem B ; 127(15): 3416-3430, 2023 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-37026896

RESUMEN

A refined numerical model for the evaporation and transport of droplets of binary solutions is introduced. Benchmarking is performed against other models found in the literature and experimental measurements of both electrodynamically trapped and freefalling droplets. The model presented represents the microphysical behavior of solutions droplets in the continuum and transition regimes, accounting for the unique hygroscopic behavior of different solutions, including the Fuchs-Sutugin and Cunningham slip correction factors, and accounting for the Kelvin effect. Simulations of pure water evaporation are experimentally validated for temperatures between 290 K and 298 K and between relative humidity values of approximately 0% and 85%. Measurements and simulations of the spatial trajectories and evaporative behavior of aqueous sodium chloride droplets are compared for relative humidity values between 0 and 40%. Simulations are shown to represent experimental data within experimental uncertainty in initial conditions. Calculations of a time-dependent Péclet number, including the temperature dependence of solute diffusion, are related to morphologies of sodium chloride particles dried at different rates. For sodium chloride solutions, dried particles are composed of collections of reproducibly shaped crystals, with higher evaporation rates resulting in higher numbers of crystals, which are smaller.

9.
Microbiol Spectr ; : e0334722, 2023 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-36912675

RESUMEN

While the airborne decay of bacterial viability has been observed for decades, an understanding of the mechanisms driving the decay has remained elusive. The airborne transport of bacteria is often a key step in their life cycle and as such, characterizing the mechanisms driving the airborne decay of bacteria is an essential step toward a more complete understanding of microbial ecology. Using the Controlled Electrodynamic Levitation and Extraction of Bioaerosols onto a Substrate (CELEBS), it was possible to systematically evaluate the impact of different physicochemical and environmental parameters on the survival of Escherichia coli in airborne droplets of Luria Bertani broth. Rather than osmotic stress driving the viability loss, as was initially considered, oxidative stress was found to play a key role. As the droplets evaporate and equilibrate with the surrounding environment, the surface-to-volume ratio increases, which in turn increased the formation of reactive oxygen species in the droplet. These reactive oxygen species appear to play a key role in driving the airborne loss of viability of E. coli. IMPORTANCE The airborne transport of bacteria has a wide range of impacts, from disease transmission to cloud formation. By understanding the factors that influence the airborne stability of bacteria, we can better understand these processes. However, while we have known for several decades that airborne bacteria undergo a gradual loss of viability, we have not previously identified the mechanisms driving this process. In this work, we discovered that oxygen surrounding an airborne droplet facilitates the formation of reactive oxygen species within the droplet, which then gradually damage and kill bacteria within the droplet. This discovery indicates that adaptations to help bacteria deal with oxidative stress may also aid their airborne survival and be essential adaptations for bacterial airborne pathogens. Understanding the adaptations bacteria need to survive in airborne droplets could eventually lead to the development of novel antimicrobials designed to inhibit their airborne survival, helping to prevent the transmission of disease.

10.
Int J Pharm ; 634: 122676, 2023 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-36738807

RESUMEN

Given the environmental compulsion to reformulate pressurised metered dose inhalers (pMDI) using new propellants with lower global warming potential, this study investigated how non-volatile excipients can be used to engineer aerosol particle microphysics and drug release. The dynamics of change in particle size, wetting and physical state were measured for single particles (glycerol/ethanol/beclomethasone dipropionate; BDP) in the aerosol phase at different relative humidity (RH) using an electrodynamic balance. BDP dissolution rates were compared for aerosols from pMDI containing different ratios of BDP:glycerol or BDP:isopropyl myristate (IPM). In 45 % RH, ethanol loss was followed by evaporation of condensed water to generate spherical particles with solid inclusions or compact irregular-shaped solid particles, according to the presence or absence of glycerol. In RH > 95 %, condensed water did not evaporate and BDP formed solid inclusions in water/glycerol or water droplets. Varying the non-volatile component, 0-50 % w/w, in pMDI resulted in a concentration-dependent 4-8-fold reduction in BDP dissolution rate. These findings demonstrate that non-volatile excipients provide a means of engineering aerosol properties and, modifying the rate of drug release from aerosol medicines. We also demonstrated differences between particles formed in vitro in ambient humidity versus higher humidity, more like that encountered during oral inhalation.


Asunto(s)
Productos Biológicos , Glicerol , Excipientes , Aerosoles , Nebulizadores y Vaporizadores , Inhaladores de Dosis Medida , Beclometasona , Administración por Inhalación , Etanol , Agua , Propelentes de Aerosoles , Tamaño de la Partícula , Hidrocarburos Fluorados
11.
Viruses ; 14(9)2022 08 24.
Artículo en Inglés | MEDLINE | ID: mdl-36146663

RESUMEN

Respiratory pathogens can be spread though the transmission of aerosolised expiratory secretions in the form of droplets or particulates. Understanding the fundamental aerosol parameters that govern how such pathogens survive whilst airborne is essential to understanding and developing methods of restricting their dissemination. Pathogen viability measurements made using Controlled Electrodynamic Levitation and Extraction of Bioaerosol onto Substrate (CELEBS) in tandem with a comparative kinetics electrodynamic balance (CKEDB) measurements allow for a direct comparison between viral viability and evaporation kinetics of the aerosol with a time resolution of seconds. Here, we report the airborne survival of mouse hepatitis virus (MHV) and determine a comparable loss of infectivity in the aerosol phase to our previous observations of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Through the addition of clinically relevant concentrations of mucin to the bioaerosol, there is a transient mitigation of the loss of viral infectivity at 40% RH. Increased concentrations of mucin promoted heterogenous phase change during aerosol evaporation, characterised as the formation of inclusions within the host droplet. This research demonstrates the role of mucus in the aerosol phase and its influence on short-term airborne viral stability.


Asunto(s)
COVID-19 , SARS-CoV-2 , Animales , Ratones , Viabilidad Microbiana , Mucinas , Aerosoles y Gotitas Respiratorias
12.
Phys Chem Chem Phys ; 24(35): 21242-21249, 2022 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-36040384

RESUMEN

The dynamics of binary collisions of equi-diameter picolitre droplets with identical viscosities, varying impact speeds and impact angles have been investigated experimentally and compared to collision outcome prediction models. Collisions between pairs of pure water droplets with a viscosity of 0.89 mPa s and pairs of aqueous-sucrose (40% w/w) droplets with a viscosity of 5.17 mPa s were examined. The colliding droplets were ∼38 µm in diameter, which is around ten times smaller than those previously investigated when examining the effect of viscosity on the outcome of binary droplet collisions. Varying the impact speed and angle resulted in different collision outcomes, including coalescence, reflexive separation and stretching separation. The collision outcomes were plotted on two viscosity dependent regime maps. The regime boundaries are generally in agreement with earlier literature for both high and low viscosity cases. The agreement between experiment and theory, for both fluids, gives more confidence in the models tested here to predict collision outcomes for droplets of this size and these viscosities.


Asunto(s)
Agua , Viscosidad
14.
J Voice ; 2022 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-36031505

RESUMEN

INTRODUCTION: Voice assessment and treatment involve the manipulation of all the subsystems of voice production, and may lead to production of respirable aerosol particles that pose a greater risk of potential viral transmission via inhalation of respirable pathogens (eg, SARS-CoV-2) than quiet breathing or conversational speech. OBJECTIVE: To characterise the production of respirable aerosol particles during a selection of voice assessment therapy tasks. METHODS: We recruited 23 healthy adult participants (12 males, 11 females), 11 of whom were speech-language pathologists specialising in voice disorders. We used an aerodynamic and an optical particle sizer to measure the number concentration and particle size distributions of respirable aerosols generated during a variety of voice assessment and therapy tasks. The measurements were carried out in a laminar flow operating theatre, with a near-zero background aerosol concentration, allowing us to quantify the number concentration and size distributions of respirable aerosol particles produced from assessment/therapy tasks studied. RESULTS: Aerosol number concentrations generated while performing assessment/therapy tasks were log-normally distributed among individuals with no significant differences between professionals (speech-language pathologists) and non-professionals or between males and females. Activities produced up to 32 times the aerosol number concentration of breathing and 24 times that of speech at 70-80 dBA. In terms of aerosol mass, activities produced up to 163 times the mass concentration of breathing and up to 36 times the mass concentration of speech. Voicing was a significant factor in aerosol production; aerosol number/mass concentrations generated during the voiced activities were 1.1-5 times higher than their unvoiced counterpart activities. Additionally, voiced activities produced bigger respirable aerosol particles than their unvoiced variants except the trills. Humming generated higher aerosol concentrations than sustained /a/, fricatives, speaking (70-80 dBA), and breathing. Oscillatory semi-occluded vocal tract exercises (SOVTEs) generated higher aerosol number/mass concentrations than the activities without oscillation. Water resistance therapy (WRT) generated the most aerosol of all activities, ∼10 times higher than speaking at 70-80 dBA and >30 times higher than breathing. CONCLUSIONS: All activities generated more aerosol than breathing, although a sizeable minority were no different to speaking. Larger number concentrations and larger particle sizes appear to be generated by activities with higher suspected airflows, with the greatest involving intraoral pressure oscillation and/or an oscillating oral articulation (WRT or trilling).

15.
Proc Natl Acad Sci U S A ; 119(27): e2200109119, 2022 07 05.
Artículo en Inglés | MEDLINE | ID: mdl-35763573

RESUMEN

Understanding the factors that influence the airborne survival of viruses such as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in aerosols is important for identifying routes of transmission and the value of various mitigation strategies for preventing transmission. We present measurements of the stability of SARS-CoV-2 in aerosol droplets (∼5 to 10 µm equilibrated radius) over timescales spanning 5 s to 20 min using an instrument to probe survival in a small population of droplets (typically 5 to 10) containing ∼1 virus/droplet. Measurements of airborne infectivity change are coupled with a detailed physicochemical analysis of the airborne droplets containing the virus. A decrease in infectivity to ∼10% of the starting value was observable for SARS-CoV-2 over 20 min, with a large proportion of the loss occurring within the first 5 min after aerosolization. The initial rate of infectivity loss was found to correlate with physical transformation of the equilibrating droplet; salts within the droplets crystallize at relative humidities (RHs) below 50%, leading to a near-instant loss of infectivity in 50 to 60% of the virus. However, at 90% RH, the droplet remains homogenous and aqueous, and the viral stability is sustained for the first 2 min, beyond which it decays to only 10% remaining infectious after 10 min. The loss of infectivity at high RH is consistent with an elevation in the pH of the droplets, caused by volatilization of CO2 from bicarbonate buffer within the droplet. Four different variants of SARS-CoV-2 were compared and found to have a similar degree of airborne stability at both high and low RH.


Asunto(s)
Partículas y Gotitas de Aerosol , COVID-19 , SARS-CoV-2 , Partículas y Gotitas de Aerosol/química , Partículas y Gotitas de Aerosol/aislamiento & purificación , COVID-19/transmisión , Humanos , Humedad , Concentración de Iones de Hidrógeno , SARS-CoV-2/aislamiento & purificación , SARS-CoV-2/patogenicidad
16.
Commun Med (Lond) ; 2: 44, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35603287

RESUMEN

Background: The coronavirus disease-19 (COVID-19) pandemic led to the prohibition of group-based exercise and the cancellation of sporting events. Evaluation of respiratory aerosol emissions is necessary to quantify exercise-related transmission risk and inform mitigation strategies. Methods: Aerosol mass emission rates are calculated from concurrent aerosol and ventilation data, enabling absolute comparison. An aerodynamic particle sizer (0.54-20 µm diameter) samples exhalate from within a cardiopulmonary exercise testing mask, at rest, while speaking and during cycle ergometer-based exercise. Exercise challenge testing is performed to replicate typical gym-based exercise and very vigorous exercise, as determined by a preceding maximally exhaustive exercise test. Results: We present data from 25 healthy participants (13 males, 12 females; 36.4 years). The size of aerosol particles generated at rest and during exercise is similar (unimodal ~0.57-0.71 µm), whereas vocalization also generated aerosol particles of larger size (i.e. was bimodal ~0.69 and ~1.74 µm). The aerosol mass emission rate during speaking (0.092 ng s-1; minute ventilation (VE) 15.1 L min-1) and vigorous exercise (0.207 ng s-1, p = 0.726; VE 62.6 L min-1) is similar, but lower than during very vigorous exercise (0.682 ng s-1, p < 0.001; VE 113.6 L min-1). Conclusions: Vocalisation drives greater aerosol mass emission rates, compared to breathing at rest. Aerosol mass emission rates in exercise rise with intensity. Aerosol mass emission rates during vigorous exercise are no different from speaking at a conversational level. Mitigation strategies for airborne pathogens for non-exercise-based social interactions incorporating vocalisation, may be suitable for the majority of exercise settings. However, the use of facemasks when exercising may be less effective, given the smaller size of particles produced.

17.
PLoS One ; 17(3): e0265076, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35271682

RESUMEN

Aerosol generating procedures (AGPs) are defined as any procedure releasing airborne particles <5 µm in size from the respiratory tract. There remains uncertainty about which dental procedures constitute AGPs. We quantified the aerosol number concentration generated during a range of periodontal, oral surgery and orthodontic procedures using an aerodynamic particle sizer, which measures aerosol number concentrations and size distribution across the 0.5-20 µm diameter size range. Measurements were conducted in an environment with a sufficiently low background to detect a patient's cough, enabling confident identification of aerosol. Phantom head control experiments for each procedure were performed under the same conditions as a comparison. Where aerosol was detected during a patient procedure, we assessed whether the size distribution could be explained by the non-salivary contaminated instrument source in the respective phantom head control procedure using a two-sided unpaired t-test (comparing the mode widths (log(σ)) and peak positions (DP,C)). The aerosol size distribution provided a robust fingerprint of aerosol emission from a source. 41 patients underwent fifteen different dental procedures. For nine procedures, no aerosol was detected above background. Where aerosol was detected, the percentage of procedure time that aerosol was observed above background ranged from 12.7% for ultrasonic scaling, to 42.9% for 3-in-1 air + water syringe. For ultrasonic scaling, 3-in-1 syringe use and surgical drilling, the aerosol size distribution matched the non-salivary contaminated instrument source, with no unexplained aerosol. High and slow speed drilling produced aerosol from patient procedures with different size distributions to those measured from the phantom head controls (mode widths log(σ)) and peaks (DP,C, p< 0.002) and, therefore, may pose a greater risk of salivary contamination. This study provides evidence for sources of aerosol generation during common dental procedures, enabling more informed evaluation of risk and appropriate mitigation strategies.


Asunto(s)
Tos , Odontología , Aerosoles , Humanos , Tamaño de la Partícula
18.
Interface Focus ; 12(2): 20210078, 2022 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-35261733

RESUMEN

Aerosol particles of respirable size are exhaled when individuals breathe, speak and sing and can transmit respiratory pathogens between infected and susceptible individuals. The COVID-19 pandemic has brought into focus the need to improve the quantification of the particle number and mass exhalation rates as one route to provide estimates of viral shedding and the potential risk of transmission of viruses. Most previous studies have reported the number and mass concentrations of aerosol particles in an exhaled plume. We provide a robust assessment of the absolute particle number and mass exhalation rates from measurements of minute ventilation using a non-invasive Vyntus Hans Rudolf mask kit with straps housing a rotating vane spirometer along with measurements of the exhaled particle number concentrations and size distributions. Specifically, we report comparisons of the number and mass exhalation rates for children (12-14 years old) and adults (19-72 years old) when breathing, speaking and singing, which indicate that child and adult cohorts generate similar amounts of aerosol when performing the same activity. Mass exhalation rates are typically 0.002-0.02 ng s-1 from breathing, 0.07-0.2 ng s-1 from speaking (at 70-80 dBA) and 0.1-0.7 ng s-1 from singing (at 70-80 dBA). The aerosol exhalation rate increases with increasing sound volume for both children and adults when both speaking and singing.

19.
Thorax ; 77(3): 292-294, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34728573

RESUMEN

Pulmonary function tests are fundamental to the diagnosis and monitoring of respiratory diseases. There is uncertainty around whether potentially infectious aerosols are produced during testing and there are limited data on mitigation strategies to reduce risk to staff. Healthy volunteers and patients with lung disease underwent standardised spirometry, peak flow and FENO assessments. Aerosol number concentration was sampled using an aerodynamic particle sizer and an optical particle sizer. Measured aerosol concentrations were compared with breathing, speaking and voluntary coughing. Mitigation strategies included a standard viral filter and a full-face mask normally used for exercise testing (to mitigate induced coughing). 147 measures were collected from 33 healthy volunteers and 10 patients with lung disease. The aerosol number concentration was highest in coughs (1.45-1.61 particles/cm3), followed by unfiltered peak flow (0.37-0.76 particles/cm3). Addition of a viral filter to peak flow reduced aerosol emission by a factor of 10 without affecting the results. On average, coughs produced 22 times more aerosols than standard spirometry (with filter) in patients and 56 times more aerosols in healthy volunteers. FENO measurement produced negligible aerosols. Cardiopulmonary exercise test (CPET) masks reduced aerosol emission when breathing, speaking and coughing significantly. Lung function testing produces less aerosols than voluntary coughing. CPET masks may be used to reduce aerosol emission from induced coughing. Standard viral filters are sufficiently effective to allow guidelines to remove lung function testing from the list of aerosol-generating procedures.


Asunto(s)
Pulmón , Máscaras , Aerosoles , Voluntarios Sanos , Humanos , Tamaño de la Partícula , Pruebas de Función Respiratoria
20.
Thorax ; 77(3): 276-282, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34737195

RESUMEN

INTRODUCTION: continuous positive airway pressure (CPAP) and high-flow nasal oxygen (HFNO) provide enhanced oxygen delivery and respiratory support for patients with severe COVID-19. CPAP and HFNO are currently designated as aerosol-generating procedures despite limited high-quality experimental data. We aimed to characterise aerosol emission from HFNO and CPAP and compare with breathing, speaking and coughing. MATERIALS AND METHODS: Healthy volunteers were recruited to breathe, speak and cough in ultra-clean, laminar flow theatres followed by using CPAP and HFNO. Aerosol emission was measured using two discrete methodologies, simultaneously. Hospitalised patients with COVID-19 had cough recorded using the same methodology on the infectious diseases ward. RESULTS: In healthy volunteers (n=25 subjects; 531 measures), CPAP (with exhalation port filter) produced less aerosol than breathing, speaking and coughing (even with large >50 L/min face mask leaks). Coughing was associated with the highest aerosol emissions of any recorded activity. HFNO was associated with aerosol emission, however, this was from the machine. Generated particles were small (<1 µm), passing from the machine through the patient and to the detector without coalescence with respiratory aerosol, thereby unlikely to carry viral particles. More aerosol was generated in cough from patients with COVID-19 (n=8) than volunteers. CONCLUSIONS: In healthy volunteers, standard non-humidified CPAP is associated with less aerosol emission than breathing, speaking or coughing. Aerosol emission from the respiratory tract does not appear to be increased by HFNO. Although direct comparisons are complex, cough appears to be the main aerosol-generating risk out of all measured activities.


Asunto(s)
COVID-19 , Aerosoles , Humanos , Oxígeno , Sistema Respiratorio , SARS-CoV-2
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...