Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Phys Rev Lett ; 129(19): 193604, 2022 Nov 04.
Artículo en Inglés | MEDLINE | ID: mdl-36399754

RESUMEN

Entangled photon pairs are key to many novel applications in quantum technologies. Semiconductor quantum dots can be used as sources of on-demand, highly entangled photons. The fidelity to a fixed maximally entangled state is limited by the excitonic fine-structure splitting. This work demonstrates that, even if this splitting is absent, the degree of entanglement cannot reach unity when the excitation pulse in a two-photon resonance scheme has a finite duration. The degradation of the entanglement has its origin in a dynamically induced splitting of the exciton states caused by the laser pulse itself. Hence, in the setting explored here, the excitation process limits the achievable concurrence for entangled photons generated in an optically excited four-level quantum emitter.

2.
Rev Sci Instrum ; 93(6): 063504, 2022 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-35778003

RESUMEN

The role of turbulence in setting boundary plasma conditions is presently a key uncertainty in projecting to fusion energy reactors. To robustly diagnose edge turbulence, we develop and demonstrate a technique to translate brightness measurements of HeI line radiation into local plasma fluctuations via a novel integrated deep learning framework that combines neutral transport physics and collisional radiative theory for the 33D - 23P transition in atomic helium with unbounded correlation constraints between the electron density and temperature. The tenets for experimental validity are reviewed, illustrating that this turbulence analysis for ionized gases is transferable to both magnetized and unmagnetized environments with arbitrary geometries. Based on fast camera data on the Alcator C-Mod tokamak, we present the first two-dimensional time-dependent experimental measurements of the turbulent electron density, electron temperature, and neutral density, revealing shadowing effects in a fusion plasma using a single spectral line.

3.
Phys Rev Lett ; 128(7): 079901, 2022 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-35244451

RESUMEN

This corrects the article DOI: 10.1103/PhysRevLett.127.100402.

4.
Phys Rev Lett ; 127(10): 100402, 2021 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-34533331

RESUMEN

The quantum regression theorem (QRT) is the most widely used tool for calculating multitime correlation functions for the assessment of quantum emitters. It is an approximate method based on a Markov assumption for environmental coupling. In this Letter we quantify properties of photons emitted from a single quantum dot coupled to phonons. For the single-photon purity and the indistinguishability, we compare numerically exact path-integral results with those obtained from the QRT. It is demonstrated that the QRT systematically overestimates the influence of the environment for typical quantum dots used in quantum information technology.

5.
Phys Rev Lett ; 126(6): 067402, 2021 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-33635695

RESUMEN

Ultrafast transmission changes around the fundamental trion resonance are studied after exciting a p-shell exciton in a negatively charged II-VI quantum dot. The biexcitonic induced absorption reveals quantum beats between hot-trion states at 133 GHz. While interband dephasing is dominated by relaxation of the P-shell hole within 390 fs, trionic coherence remains stored in the spin system for 85 ps due to Pauli blocking of the triplet electron. The complex spectrotemporal evolution of transmission is explained analytically by solving the Maxwell-Liouville equations. Pump and probe polarizations provide full control over amplitude and phase of the quantum beats.

6.
Phys Rev Lett ; 125(15): 155001, 2020 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-33095602

RESUMEN

Power exhaust from the bulk plasma is significantly altered by symmetry breaking magnetic perturbation fields, because these create direct connections (perturbed field lines) from the confined high temperature plasma to solid surfaces. The same amount of power is distributed among those new exhaust channels as for a symmetric magnetic configuration, which reduces the local upstream heat flux flowing down the perturbed field lines, thereby making access to detachment easier (i.e., at lower upstream density) for the divertor plasma near the location corresponding to the symmetric magnetic separatrix. However, the divertor plasma regions with connection to the bulk plasma are extended nonaxisymmetrically further outside, where significant heat loads occur, unlike in the symmetric configuration. The temperature remains high at those locations, which reduces the divertor plasma dissipation capacity, making the mitigation of heat loads more difficult to achieve.

7.
J Phys Condens Matter ; 31(28): 28LT01, 2019 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-30965286

RESUMEN

The spatio-temporal dynamics of electrons moving in a 2D plane is challenging to detect when the required resolution shrinks simultaneously to nanometer length and subpicosecond time scale. We propose a detection scheme relying on phonon-induced carrier capture from 2D unbound states into the bound states of an embedded quantum dot. This capture process happens locally and here we explore if this locality is sufficient to use the carrier capture process as detection of the ultrafast diffraction of electrons from an obstacle in the 2D plane. As an example we consider an electronic wave packet traveling in a semiconducting monolayer of the transition metal dichalcogenide MoSe2, and we study the scattering-induced dynamics using a single particle Lindblad approach. Our results offer a new way to high resolution detection of the spatio-temporal carrier dynamics.

8.
Phys Rev Lett ; 118(13): 133901, 2017 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-28409974

RESUMEN

A picosecond acoustic pulse can be used to control the lasing emission from semiconductor nanostructures by shifting their electronic transitions. When the active medium, here an ensemble of (In,Ga)As quantum dots, is shifted into or out of resonance with the cavity mode, a large enhancement or suppression of the lasing emission can dynamically be achieved. Most interesting, even in the case when gain medium and cavity mode are in resonance, we observe an enhancement of the lasing due to shaking by coherent phonons. In order to understand the interactions of the nonlinearly coupled photon-exciton-phonon subsystems, we develop a semiclassical model and find an excellent agreement between theory and experiment.

9.
Osteoarthritis Cartilage ; 23(10): 1704-12, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26067517

RESUMEN

OBJECTIVE: The purpose of this study is to evaluate the ability of machine learning to discriminate between magnetic resonance images (MRI) of normal and pathological human articular cartilage obtained under standard clinical conditions. METHOD: An approach to MRI classification of cartilage degradation is proposed using pattern recognition and multivariable regression in which image features from MRIs of histologically scored human articular cartilage plugs were computed using weighted neighbor distance using compound hierarchy of algorithms representing morphology (WND-CHRM). The WND-CHRM method was first applied to several clinically available MRI scan types to perform binary classification of normal and osteoarthritic osteochondral plugs based on the Osteoarthritis Research Society International (OARSI) histological system. In addition, the image features computed from WND-CHRM were used to develop a multiple linear least-squares regression model for classification and prediction of an OARSI score for each cartilage plug. RESULTS: The binary classification of normal and osteoarthritic plugs yielded results of limited quality with accuracies between 36% and 70%. However, multiple linear least-squares regression successfully predicted OARSI scores and classified plugs with accuracies as high as 86%. The present results improve upon the previously-reported accuracy of classification using average MRI signal intensities and parameter values. CONCLUSION: MRI features detected by WND-CHRM reflect cartilage degradation status as assessed by OARSI histologic grading. WND-CHRM is therefore of potential use in the clinical detection and grading of osteoarthritis.


Asunto(s)
Algoritmos , Cartílago Articular/patología , Procesamiento de Imagen Asistido por Computador/métodos , Aprendizaje Automático , Osteoartritis de la Rodilla/patología , Reconocimiento de Normas Patrones Automatizadas/métodos , Imagen de Difusión por Resonancia Magnética , Humanos , Análisis de los Mínimos Cuadrados , Modelos Lineales , Imagen por Resonancia Magnética , Análisis Multivariante , Osteoartritis de la Rodilla/diagnóstico
10.
J Phys Condens Matter ; 26(42): 423203, 2014 Oct 22.
Artículo en Inglés | MEDLINE | ID: mdl-25273644

RESUMEN

For many applications of semiconductor quantum dots in quantum technology, well-controlled state preparation of the quantum dot states is mandatory. Since quantum dots are embedded in the semiconductor matrix, their interaction with phonons often plays a major role in the preparation process. In this review, we discuss the influence of phonons on three basically different optical excitation schemes that can be used for the preparation of exciton, biexciton and superposition states: a resonant excitation leading to Rabi rotations in the excitonic system, an excitation with chirped pulses exploiting the effect of adiabatic rapid passage and an off-resonant excitation giving rise to a phonon-assisted state preparation. We give an overview of experimental and theoretical results, showing the role of phonons and compare the performance of the schemes for state preparation.

11.
J Phys Condens Matter ; 26(35): 355802, 2014 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-25115958

RESUMEN

The energy transport of acoustic phonons generated by the optical excitation of a quantum dot as well as the coherence properties of these phonons are studied theoretically both for the case of a pulsed excitation and for a continuous wave (CW) excitation switched on instantaneously. For a pulsed excitation, depending on pulse area and pulse duration, a finite number of phonon wave packets is emitted, while for the case of a CW excitation a sequence of wave packets with decreasing amplitude is generated after the excitation has been switched on. We show that the energy flow associated with the generated phonons is partly related to coherent phonon oscillations and partly to incoherent phonon emission. The efficiency of the energy transfer to the phonons and the details of the energy flow depend strongly and in a non-monotonic way on the Rabi frequency exhibiting a resonance behavior. However, in the case of CW excitation it turns out that the total energy transferred to the phonons is directly linked in a monotonic way to the Rabi frequency.

12.
Phys Rev Lett ; 105(15): 157401, 2010 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-21230936

RESUMEN

Time-dependent lattice fluctuations of an optically excited strongly confined quantum dot are investigated with the aim to analyze the characteristics commonly used for identifying the presence of squeezed phonon states. It is demonstrated that the appearance of fluctuations oscillating with twice the phonon frequency, commonly regarded as a clear indication of squeezed states, cannot be considered as such. The source of the discrepancy with earlier investigations is discussed. Conditions for generating a squeezed state by using a two-pulse excitation are analyzed.

13.
Phys Rev Lett ; 103(16): 165005, 2009 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-19905705

RESUMEN

Good alignment of the magnetic field line pitch angle with the mode structure of an external resonant magnetic perturbation (RMP) field is shown to induce modulation of the pedestal electron pressure p(e) in high confinement high rotation plasmas at the DIII-D tokamak with a shape similar to ITER, the next step tokamak experiment. This is caused by an edge safety factor q95 resonant enhancement of the thermal transport, while in contrast, the RMP induced particle pump out does not show a significant resonance. The measured p(e) reduction correlates to an increase in the modeled stochastic layer width during pitch angle variations matching results from resistive low rotation plasmas at the TEXTOR tokamak. These findings suggest a field line pitch angle resonant formation of a stochastic magnetic edge layer as an explanation for the q95 resonant character of type-I edge localized mode suppression by RMPs.

14.
Phys Rev Lett ; 102(17): 177403, 2009 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-19518830

RESUMEN

For a CdTe quantum dot doped with a single Mn atom we analyze the dynamics of the Mn spin when the dot is excited by ultrashort laser pulses. Because of the exchange interaction with the Mn atom, electron and hole spins can flip and induce a change of the Mn spin. Including both heavy and light-hole excitons and using suitable pulse sequences, angular momentum can be transferred from the light to the Mn system while the exciton system returns to its ground state. We show that by a series of ultrashort laser pulses the Mn spin can be selectively driven into each of its six possible orientations on a picosecond timescale. By applying a magnetic field the total switching time and the required number of pulses can be strongly reduced.

15.
Rev Sci Instrum ; 79(10): 10F532, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19044674

RESUMEN

The quantitative exploitation of active beam spectra is largely based on an advanced atomic modeling. Under the ITER operating conditions the penetration depth of a diagnostic beam into the plasma core crucially affects the intensities of spectral lines and hence the uncertainties of derived plasma parameters. A critical review of atomic data and an assessment of its error margins are, therefore, urgently needed. The aim of the present work is to verify the existing beam-stopping and beam-emission data for hydrogen beam in fusion plasmas. The agreement between the ADAS database and the present calculations is found to be within 5% for the beam-stopping data in a H-plasma. The calculation of beam attenuation in the presence of He-ash (4%) and Be ions (2%) demonstrates the agreement between the present data and the ADAS database within 10%. Finally, the maximum deviation of 15% is found only for beam-emission data at the electron density of 1x10(12)-2x10(12) cm(-3), which is significantly below the ITER density of 10(14) cm(-3).

16.
Surg Endosc ; 17(3): 452-6, 2003 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-12399845

RESUMEN

BACKGROUND: Enteral nutrition should be restored immediately after trauma, acute lesion, or surgical intervention. Nutrition through nasogastric tubes is often not feasible in patients in the posttraumatic state in medical intensive care units because of recurrent episodes of gastroesophageal reflux and subsequent aspiration due to gastric paresis. Placement of nasojejunal tubes with available techniques is unreliable. METHODS: We developed a new combined catheter system for jejunal delivery and simultaneous drainage of gastric juice (Cath-in-Cath, PreOx-RS, Germany). CONCLUSION: In this article, this new tube system is presented. The safety and excellent efficacy of the novel system for enteral nutrition therapy are reported in the first series of patients worldwide.


Asunto(s)
Nutrición Enteral/métodos , Intubación Gastrointestinal/métodos , Yeyuno , Nutrición Enteral/instrumentación , Diseño de Equipo , Gastroscopios , Alemania , Humanos , Intubación Gastrointestinal/instrumentación , Apoyo Nutricional , Estudios Prospectivos
17.
Arch Facial Plast Surg ; 3(4): 264-6, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11710862

RESUMEN

OBJECTIVE: To evaluate the effect of acute postoperative alcohol withdrawal on survival of vascularized fibular grafts for mandibular reconstruction. DESIGN: Retrospective case series of 17 consecutive patients. MAIN OUTCOMES MEASURE: Relation between flap survival and alcohol withdrawal. RESULTS: Flap survival rate was 25% for patients who experienced delirium tremens and 85% in the other patients. Had all flaps in patients with postoperative alcohol withdrawal survived, the success rate would have been 89%. Flap loss was related to acute alcohol withdrawal (P =.02, chi2 analysis). The relationship between complication rate and alcohol withdrawal was also significant, using the Fisher exact test. CONCLUSIONS: Fibular free flap reconstruction of the mandible is clearly cost-effective when it facilitates return to social function and productivity. In our experience, acute alcohol withdrawal in the first 72 hours after surgery is associated with a high incidence of flap loss. Therefore, we believe that patients at significant risk for alcohol withdrawal should undergo detoxification preoperatively. Society's economic return for investing in free flap reconstruction comes from minimizing convalescence and maximizing postoperative patient productivity. This return will not be realized for poorly selected patients. We are looking further into the effects of alcoholism on flap survival rates.


Asunto(s)
Etanol/efectos adversos , Supervivencia de Injerto , Mandíbula/cirugía , Complicaciones Posoperatorias , Síndrome de Abstinencia a Sustancias/complicaciones , Colgajos Quirúrgicos , Enfermedad Aguda , Adulto , Anciano , Delirio por Abstinencia Alcohólica/complicaciones , Femenino , Humanos , Tiempo de Internación , Masculino , Neoplasias Mandibulares/cirugía , Persona de Mediana Edad , Colgajos Quirúrgicos/irrigación sanguínea
18.
Otolaryngol Head Neck Surg ; 125(1): 93-5, 2001 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-11458221

RESUMEN

OBJECTIVE: To describe and evaluate an ear piercing and earring retention method for individuals with metal hypersensitivity. SETTING: Private facial plastic surgery practice associated with a tertiary care medical center. METHODS: Thirty-one patients with a history of hypersensitivity to metallic jewelry (62 ears) underwent earlobe piercing with an intravenous catheter. RESULTS: None of the patients experienced an infection or hypersensitivity reaction. All patients were able to wear nickel-free earrings for short periods without using the shortened catheter. CONCLUSION: Using the distal shaft of an intravenous catheter as an earring post sheath is a safe and effective technique that allows hypersensitive individuals to wear earrings in pierced ears on a limited basis.


Asunto(s)
Cateterismo/instrumentación , Dermatitis Alérgica por Contacto/etiología , Oído Externo/cirugía , Metales/efectos adversos , Procedimientos de Cirugía Plástica , Punciones/métodos , Femenino , Humanos , Masculino , Resultado del Tratamiento
19.
J Voice ; 15(2): 295-304, 2001 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-11411484

RESUMEN

Vocal fold scar disrupts the mucosal wave and interferes with glottic closure. Treatment involves a multidisciplinary approach that includes voice therapy, medical management, and sometimes surgery. We reviewed the records of the first eight patients who underwent autologous fat implantation for vocal fold scar. Information on the etiology of scar, physical findings, and prior interventions were collected. Videotapes of videostroboscopic findings and perceptual voice ratings [Grade, Roughness, Breathiness, Asthenia, Strain (GRBAS)] were randomized and analyzed independently by four blinded observers. Etiology of scar included mass excision (7), vocal fold stripping (3), congenital sulcus (2), and hemorrhage (1). Prior surgical procedures performed included thyroplasty (1), autologous fat injection (9), excision of scar (2), and lysis of adhesions (2). Strobovideolaryngoscopy: Statistically significant improvement was found in glottic closure, mucosal wave, and stiffness (P = 0.05). Perceptual ratings (GRBAS): Statistically significant improvement was found in all five parameters, including overall Grade, Roughness, Breathiness, Asthenia, and Strain (P = 0.05). Patients appear to have improved vocal fold function and quality of voice after autologous fat implantation in the vocal fold. Autologous fat implantation is an important adjunctive procedure in the management of vocal fold scar, and a useful addition to the armamentarium of the experienced phonomicrosurgeon.


Asunto(s)
Tejido Adiposo/trasplante , Cicatriz/complicaciones , Cicatriz/fisiopatología , Pliegues Vocales/fisiopatología , Trastornos de la Voz , Adulto , Femenino , Estudios de Seguimiento , Humanos , Inyecciones Intramusculares , Masculino , Estudios Retrospectivos , Trasplante Autólogo , Trastornos de la Voz/etiología , Trastornos de la Voz/fisiopatología , Trastornos de la Voz/terapia
20.
Arch Otolaryngol Head Neck Surg ; 127(4): 418-21, 2001 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-11296051

RESUMEN

OBJECTIVE: To determine whether prior silicone injection increases the risks associated with carbon dioxide laser resurfacing. DESIGN: Laboratory determination of the effect of laser energy on liquid silicone; histologic evaluation of silicone-injected skin after lasing; and histologic demonstration of silicone deposits in all layers of dermis years after injection of silicone as filler fluid. SETTING: Tertiary care medical center. PATIENT-RELATED DATA: Histologic examination of freshly excised skin injected with microdroplets of liquid silicone and subjected to application of carbon dioxide laser energy; histologic examination of skin excised years after silicone injection. INTERVENTIONS: High-speed clinical photographic imaging of the effect of laser energy on silicone fluid; histologic examination of hematoxylin-eosin-stained sections of skin injected with liquid silicone and subsequently lased. MAIN OUTCOME MEASURES: Response of liquid silicone to application of laser energy; effect of this response on surrounding normal skin. RESULTS: Exposure of microdroplets of liquid silicone to carbon dioxide laser energy produced flaring with frank flame. Flaring of dermal silicone caused collateral skin damage. CONCLUSIONS: Prior injection with liquid silicone is a relative contraindication to cutaneous resurfacing with the carbon dioxide laser. Surgical excision of silicone-injected skin may be preferable for many patients. A strenuous needs assessment should be done, alternatives for skin rejuvenation considered, and comprehensive informed consent obtained from the patient before embarking on laser resurfacing of silicone-injected skin.


Asunto(s)
Terapia por Láser , Procedimientos de Cirugía Plástica , Elastómeros de Silicona , Dióxido de Carbono , Contraindicaciones , Humanos , Piel/patología , Piel/efectos de la radiación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA