Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
MAGMA ; 36(3): 395-408, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37208554

RESUMEN

OBJECTIVE: Low-cost low-field point-of-care MRI systems are used in many different applications. System design has correspondingly different requirements in terms of imaging field-of-view, spatial resolution and magnetic field strength. In this work an iterative framework has been created to design a cylindrical Halbach-based magnet along with integrated gradient and RF coils that most efficiently fulfil a set of user-specified imaging requirements. METHODS: For efficient integration, target field methods are used for each of the main hardware components. These have not been used previously in magnet design, and a new mathematical model was derived accordingly. These methods result in a framework which can design an entire low-field MRI system within minutes using standard computing hardware. RESULTS: Two distinct point-of-care systems are designed using the described framework, one for neuroimaging and the other for extremity imaging. Input parameters are taken from literature and the resulting systems are discussed in detail. DISCUSSION: The framework allows the designer to optimize the different hardware components with respect to the desired imaging parameters taking into account the interdependencies between these components and thus give insight into the influence of the design choices.


Asunto(s)
Imagen por Resonancia Magnética , Sistemas de Atención de Punto , Diseño de Equipo , Imagen por Resonancia Magnética/métodos , Neuroimagen , Imanes , Fantasmas de Imagen
2.
Magn Reson Med ; 89(5): 2109-2116, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36708148

RESUMEN

PURPOSE: High permittivity dielectric pads are known to be effective for tailoring the RF field and improving image quality in high field MRI. Despite a number of studies reporting benign specific absorption rate (SAR) effects, their "universal" safety remains an open concern. In this work, we evaluate the impact of the insulation material in between the pad and the body, using both RF simulations as well as phantom experiments. METHODS: A 3T configuration with high permittivity material was simulated and characterized experimentally in terms of B1 + fields and RF power absorption, both with and without electrical insulation in between the high permittivity material and the sample. Different insulation conditions were compared, and electromagnetic analyses on the induced current density were performed to elucidate the effect. RESULTS: Increases in RF heating of up to 49% were observed experimentally in a tissue-mimicking phantom after removing the material insulation. The B1 + magnitude and RF transceive phase were not affected. Simulations indicated that an insulation thickness of 0.5-2 mm should be accounted for in numerical models in order to ensure reliable results. CONCLUSION: A reliable RF safety assessment of high permittivity dielectric pads requires accounting for the insulating properties of the plastic encasing. Ignoring the electrical insulation can lead to erroneous results with substantial increases in local SAR at the interface. Conversely, the material insulation does not need to be modeled to predict the B1 + effects during the design of the pad geometry.


Asunto(s)
Electricidad , Imagen por Resonancia Magnética , Diseño de Equipo , Imagen por Resonancia Magnética/efectos adversos , Imagen por Resonancia Magnética/métodos , Ondas de Radio , Fantasmas de Imagen
3.
Magn Reson Med ; 88(1): 464-475, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35344602

RESUMEN

PURPOSE: Parallel RF transmission (PTx) is one of the key technologies enabling high quality imaging at ultra-high fields (≥7T). Compliance with regulatory limits on the local specific absorption rate (SAR) typically involves over-conservative safety margins to account for intersubject variability, which negatively affect the utilization of ultra-high field MR. In this work, we present a method to generate a subject-specific body model from a single T1-weighted dataset for personalized local SAR prediction in PTx neuroimaging at 7T. METHODS: Multi-contrast data were acquired at 7T (N = 10) to establish ground truth segmentations in eight tissue types. A 2.5D convolutional neural network was trained using the T1-weighted data as input in a leave-one-out cross-validation study. The segmentation accuracy was evaluated through local SAR simulations in a quadrature birdcage as well as a PTx coil model. RESULTS: The network-generated segmentations reached Dice coefficients of 86.7% ± 6.7% (mean ± SD) and showed to successfully address the severe intensity bias and contrast variations typical to 7T. Errors in peak local SAR obtained were below 3.0% in the quadrature birdcage. Results obtained in the PTx configuration indicated that a safety margin of 6.3% ensures conservative local SAR estimates in 95% of the random RF shims, compared to an average overestimation of 34% in the generic "one-size-fits-all" approach. CONCLUSION: A subject-specific body model can be automatically generated from a single T1-weighted dataset by means of deep learning, providing the necessary inputs for accurate and personalized local SAR predictions in PTx neuroimaging at 7T.


Asunto(s)
Imagen por Resonancia Magnética , Neuroimagen , Imagen por Resonancia Magnética/métodos , Redes Neurales de la Computación , Fantasmas de Imagen
4.
Magn Reson Med ; 85(5): 2856-2868, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33280166

RESUMEN

PURPOSE: To remove the necessity of the tranceive phase assumption for CSI-EPT and show electrical properties maps reconstructed from measured data obtained using a standard 3T birdcage body coil setup. METHODS: The existing CSI-EPT algorithm is reformulated to use the transceive phase rather than relying on the transceive phase assumption. Furthermore, the radio frequency (RF)-shield is numerically implemented to accurately model the RF fields inside the MRI scanner. We verify that the reformulated two-dimensional (2D) CSI-EPT algorithm can reconstruct electrical properties maps given 2D electromagnetic simulations. Afterward, the algorithm is tested with three-dimensional (3D) FDTD simulations to investigate if the 2D CSI-EPT can retrieve the electrical properties for 3D RF fields. Finally, an MR experiment at 3T with a phantom is performed. RESULTS: From the results of the 2D simulations, it is seen that CSI-EPT can reconstruct the electrical properties using MRI accessible quantities. For 3D simulations, it is observed that the electrical properties are underestimated, nonetheless, CSI-EPT has a lower standard deviation than the standard Helmholtz based methods. Finally, the first CSI-EPT reconstructions based on measured data are presented showing comparable accuracy and precision to reconstructions based on simulated data, and demonstrating the feasibility of CSI-EPT. CONCLUSIONS: The CSI-EPT algorithm was rewritten to use MRI accessible quantities. This allows for CSI-EPT to fully exploit the benefits of the higher static magnetic field strengths with a standard quadrature birdcage coil setup.


Asunto(s)
Imagen por Resonancia Magnética , Tomografía , Algoritmos , Procesamiento de Imagen Asistido por Computador , Fantasmas de Imagen , Tomografía Computarizada por Rayos X
5.
Magn Reson Med ; 83(5): 1796-1809, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-31566265

RESUMEN

PURPOSE: Patients who have medical metallic implants, e.g. orthopaedic implants and pacemakers, often cannot undergo an MRI exam. One of the largest risks is tissue heating due to the radio frequency (RF) fields. The RF safety assessment of implants is computationally demanding. This is due to the large dimensions of the transmit coil compared to the very detailed geometry of an implant. METHODS: In this work, we explore a faster computational method for the RF safety assessment of implants that exploits the small geometry. The method requires the RF field without an implant as a basis and calculates the perturbation that the implant induces. The inputs for this method are the incident fields and a library matrix that contains the RF field response of every edge an implant can occupy. Through a low-rank inverse update, using the Sherman-Woodbury-Morrison matrix identity, the EM response of arbitrary implants can be computed within seconds. We compare the solution from full-wave simulations with the results from the presented method, for two implant geometries. RESULTS: From the comparison, we found that the resulting electric and magnetic fields are numerically equivalent (maximum error of 1.35%). However, the computation was between 171 to 2478 times faster than the corresponding GPU accelerated full-wave simulation. CONCLUSIONS: The presented method enables for rapid and efficient evaluation of the RF fields near implants and might enable situation-specific scanning conditions.


Asunto(s)
Campos Electromagnéticos , Ondas de Radio , Simulación por Computador , Humanos , Imagen por Resonancia Magnética , Fantasmas de Imagen , Prótesis e Implantes
6.
IEEE Trans Med Imaging ; 37(9): 2080-2089, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29994520

RESUMEN

Contrast source inversion-electrical properties tomography (CSI-EPT) is an iterative reconstruction method to retrieve the electrical properties (EPs) of tissues from magnetic resonance data. The method is based on integral representations of the electromagnetic field and has been shown to allow EP reconstructions of small structures as well as tissue boundaries with compelling accuracy. However, to date, the CSI-EPT has been implemented for 2-D configurations only, which limits its applicability. In this paper, a full 3-D extension of the CSI-EPT method is presented, to enable CSI-EPT to be applied to realistic 3-D scenarios. Here, we demonstrate a proof-of-principle of 3-D CSI-EPT and present the reconstructions of a 3-D abdominal body section and a 3-D head model using different settings of the transmit coil. Numerical results show that the full 3-D approach yields accurate reconstructions of the EPs, even at tissue boundaries and is most accurate in regions where the absolute value of the electric field is highest.


Asunto(s)
Imagenología Tridimensional/métodos , Tomografía/métodos , Abdomen/diagnóstico por imagen , Algoritmos , Campos Electromagnéticos , Femenino , Cabeza/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Modelos Anatómicos
7.
Med Biol Eng Comput ; 55(2): 225-233, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27108291

RESUMEN

Specific absorption rate (SAR) assessment is essential for safety purposes during MR acquisition. Online SAR assessment is not trivial and requires, in addition, knowledge of the electric tissue properties and the electric fields in the human anatomy. In this study, the potential of the recently developed CSI-EPT method to reconstruct SAR distributions is investigated. This method is based on integral representations for the electromagnetic field and attempts to reconstruct the tissue parameters and the electric field strength based on [Formula: see text] field data only. Full three-dimensional FDTD simulations using a female pelvis model are used to validate two-dimensional CSI reconstruction results in the central transverse plane of a 3T body coil. Numerical experiments demonstrate that the reconstructed SAR distributions are in good agreement with the SAR distributions as determined via 3D FDTD simulations and show that these distributions can be computed very efficiently in the central transverse plane of a body coil with the two-dimensional approach of CSI-EPT.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Tomografía/métodos , Simulación por Computador , Campos Electromagnéticos , Femenino , Humanos , Pelvis/diagnóstico por imagen , Reproducibilidad de los Resultados
8.
Int J Hyperthermia ; 32(5): 558-68, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-26982889

RESUMEN

Introduction The reliability of hyperthermia treatment planning (HTP) is strongly dependent on the accuracy of the electric properties of each tissue. The values currently used are mostly based on ex vivo measurements. In this study, in vivo conductivity of human muscle, bladder content and cervical tumours, acquired with magnetic resonance-based electric properties tomography (MR-EPT), are exploited to investigate the effect on HTP for cervical cancer patients. Methods Temperature-based optimisation of five different patients was performed using literature-based conductivity values yielding certain antenna settings, which are then used to compute the temperature distribution of the patient models with EPT-based conductivity values. Furthermore, the effects of altered bladder and muscle conductivity were studied separately. Finally, the temperature-based optimisation was performed with patient models based on EPT conductivity values. Results The tumour temperatures for all EPT-based dielectric patient models were lower compared to the optimal tumour temperatures based on literature values. The largest deviation was observed for patient 1 with ΔT90 = -1.37 °C. A negative impact was also observed when the treatment was optimised based on the EPT values. For four patients ΔT90 was less than 0.6 °C; for one patient it was 1.5 °C. Conclusions Electric conductivity values acquired by EPT are higher than commonly used from literature. This difference has a substantial impact on cervical tumour temperatures achieved during hyperthermia. A higher conductivity in the bladder and in the muscle tissue surrounding the tumour leads to higher power dissipation in the bladder and muscle, and therefore to lower tumour temperatures.


Asunto(s)
Conductividad Eléctrica , Hipertermia Inducida , Neoplasias del Cuello Uterino/terapia , Femenino , Humanos , Músculos/diagnóstico por imagen , Temperatura , Tomografía/métodos , Vejiga Urinaria/diagnóstico por imagen , Neoplasias del Cuello Uterino/diagnóstico por imagen
9.
Magn Reson Med ; 75(5): 2185-94, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26125996

RESUMEN

PURPOSE: In this study, we analyzed dielectric shimming by formulating it as an electromagnetic scattering problem using integral equations. METHODS: Three-dimensional simulations of the radiofrequency field in two configurations using different materials were analyzed in terms of induced currents and secondary fields. A two-dimensional integral equation method with different backgrounds was used to identify the underlying physical mechanisms. This framework was then used to develop an inversion method for the design of dielectric pads. RESULTS: The effects of a dielectric pad can be attributed to the interference of a secondary field that is produced by the currents induced in the dielectric pad, radiating in an inhomogeneous background. The integral equation method with inhomogeneous background reduces the complexity of the forward and inverse problem significantly and can be used to optimize the permittivity distribution for a desired B1+ field. Agreement with experimental B1+ maps was obtained in a cylindrical phantom, demonstrating the validity of the method. CONCLUSIONS: The integral equation method with inhomogeneous background yields an efficient numerical framework for the analysis and inverse design of dielectric shimming materials.


Asunto(s)
Imagen por Resonancia Magnética , Neuroimagen/métodos , Algoritmos , Compuestos de Bario/química , Encéfalo/diagnóstico por imagen , Calcio/química , Simulación por Computador , Conductividad Eléctrica , Campos Electromagnéticos , Radiación Electromagnética , Diseño de Equipo , Cabeza/diagnóstico por imagen , Humanos , Imagenología Tridimensional , Masculino , Modelos Estadísticos , Ondas de Radio , Reproducibilidad de los Resultados , Dispersión de Radiación , Titanio/química
10.
IEEE Trans Med Imaging ; 34(9): 1788-96, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25706578

RESUMEN

Electric properties tomography (EPT) is an imaging modality to reconstruct the electric conductivity and permittivity inside the human body based on B1(+) maps acquired by a magnetic resonance imaging (MRI) system. Current implementations of EPT are based on the local Maxwell equations and assume piecewise constant media. The accuracy of the reconstructed maps may therefore be sensitive to noise and reconstruction errors occur near tissue boundaries. In this paper, we introduce a multiplicative regularized CSI-EPT method (contrast source inversion-electric properties tomography) where the electric tissue properties are retrieved in an iterative fashion based on a contrast source inversion approach. The method takes the integral representations for the electromagnetic field as a starting point and the tissue parameters are obtained by iteratively minimizing an objective function which measures the discrepancy between measured and modeled data and the discrepancy in satisfying a consistency equation known as the object equation. Furthermore, the objective function consists of a multiplicative Total Variation factor for noise suppression during the reconstruction process. Finally, the presented implementation is able to simultaneously include more than one B1(+) data set acquired by complementary RF excitation settings. We have performed in vivo simulations using a female pelvis model to compute the B1(+) fields. Three different RF excitation settings were used to acquire complementary B1(+) fields for an improved overall reconstruction. Numerical results illustrate the improved reconstruction near tissue boundaries and the ability of CSI-EPT to reconstruct small tissue structures.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Tomografía/métodos , Algoritmos , Femenino , Humanos , Modelos Biológicos , Pelvis/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...